Mass balance
- Steady state
- in = out
- Total balance
- ṁ1 + ṁ2 = ṁ3
- Component balance
- ṁ1x1 + ṁ2x2 = ṁ3x3
- Evaporator
- F·xF = P·xP, W = F − P
Formula sheets, the key method steps for every topic and 24 practice problems, with full solutions at the back.
How much of stream 2 must be added each hour to stream 1 so that the blended product contains 20% sugar? Find ṁ2.
An evaporator concentrates a salt solution by boiling off pure water. Find the water evaporated W in kg/h.
Hot ethanol cools water in a counter-flow heat exchanger with no heat loss. Find the water outlet temperature tout.
Hot glycol mix heats water in an exchanger that loses 15% of the heat released by the hot stream to the surroundings. Find the water flow rate ṁc needed.
What volume V does 330 g of CH₄ occupy at 550 kPa and 55 °C? Treat it as an ideal gas.
A fixed amount of He goes from 100 kPa, 2 L, 40 °C to 300 kPa and 180 °C. Find the new volume V2.
30 g of CH4 and 32 g of O2 react according to CH4 + 2O2 → CO2 + 2H2O. What mass m of CO2 can form?
In the reaction 2H2 + O2 → 2H2O, 10 g of H2 reacts completely (the other reactants are in excess) and 81.34 g of H2O is collected. Find the percent yield Y.
0.4 mol/L of H₂ and 0.4 mol/L of I₂ are put in a container and react: H₂ + I₂ ⇌ 2HI, with Kc = 9. Find the equilibrium concentration [HI].
PCl₅ decomposes: PCl₅ ⇌ PCl₃ + Cl₂, with Kc = 0.08 at the reaction temperature. A container starts with 0.2 mol/L of PCl₅ only. Find the equilibrium concentration [Cl2].
A 75 g block of copper (c = 0.385 J/(g·°C)) at 190 °C is dropped into 400 g of water (c = 4.18 J/(g·°C)) at 23 °C in an insulated cup. Find the final temperature Tf.
Use the standard enthalpies of formation to find the heat q released when 20 g of CH3OH (M = 32.04 g/mol) burns completely: 2CH3OH + 3O₂ → 2CO₂ + 4H₂O(l). Give q as a positive number.
A second-order reaction (−rA = k·CA²) in a batch reactor has k = 0.1 L/(mol·min) and starts at 2 mol/L. How long does it take to reach 75% conversion? Find t.
A reaction has an activation energy of 100 kJ/mol. At 30 °C it is too slow. To what temperature T2 (in °C) must it be heated to make it 5 times faster?
A first-order liquid-phase reaction A → B with k = 0.05 min⁻¹ is carried out in a plug-flow reactor (PFR) fed at 20 L/min. The density is constant and the reactor is at steady state. Find the reactor volume V in litres for 80% conversion of A.
A first-order liquid-phase reaction (k = 0.25 min⁻¹) runs in two equal CSTRs in series, each of 500 L. The feed rate is 20 L/min, the density is constant and the reactors are at steady state. Find the overall conversion X in percent.
A parallel-flow heat exchanger transfers 50 kW. The hot fluid cools from 155 to 115 °C and the cold fluid heats from 20 to 85 °C. The overall heat transfer coefficient is 200 W/(m²·K). Find the heat transfer area A needed.
In a counter-flow double-pipe heat exchanger, hot oil (0.8 kg/s, cp = 2.1 kJ/(kg·K)) flows in the inner tube and cools from 105 to 50 °C. Water (0.3 kg/s, cp = 4.18 kJ/(kg·K)) in the annulus enters at 20 °C. The inner tube has a diameter of 50 mm, and U = 250 W/(m²·K) is based on this diameter. Find the tube length L needed.
A wall is made of 150 mm of expanded polystyrene and 25 mm of wood, with an area of 12 m². The outer faces are at 21 °C and -8 °C. Find the temperature Ti at the interface between the two layers.
A wall of 50 mm expanded polystyrene and 100 mm gypsum board separates a room at 20 °C from outside air at -9 °C. The convection coefficients are 8 W/(m²·K) inside and 25 W/(m²·K) outside, and the wall area is 10 m². Find the heat loss Q̇ through the wall.
Water flows at 8 L/s through a pipe 50 m long with an inside diameter of 100 mm. Use the Darcy friction factor f = 0.015 and g = 9.81 m/s². Find the friction head loss hf.
Two open reservoirs are joined by a pipe 150 m long with an inside diameter of 200 mm and a Darcy friction factor f = 0.02. The water surface of the upper reservoir is 6 m above that of the lower one. The minor losses are a square-edged entrance (K = 0.5), 2 bends (K = 0.3 each), a valve (K = 2) and the exit into the lower reservoir (K = 1.0). Use g = 9.81 m/s². Find the flow rate Q in L/s.
A pump with an efficiency of 80% delivers 60 L/s of water (ρ = 1000 kg/m³) against a head of 72 m. Use g = 9.81 m/s². Find the shaft power Pshaft needed, in kW.
A pump moves 100 L/s of water (ρ = 1000 kg/m³) from an open lower reservoir to an upper tank whose water surface is 10 m higher. The pipe is 100 m long with an inside diameter of 250 mm and a Darcy friction factor f = 0.02; the minor-loss coefficients add up to ΣK = 4 (entrance and exit included). Use g = 9.81 m/s². Find the head H the pump must add.
Answer: ṁ2 = 733.3 kg/h
Steady-state mass balance: in = out for the total and for each component. Blending problems combine both.
Answer: W = 1387 kg/h
Tie component: a component that passes through unchanged in one stream (here the solute) links the flows directly. Then the total balance gives the rest.
Answer: tout = 22.78 °C
Exchanger energy balance: with no losses, ṁhcp,h(Th,in − Th,out) = ṁccp,c(tout − tin).
Answer: ṁc = 6.149 kg/s
Energy balance with losses: heat released = heat absorbed + heat lost.
Answer: V = 102.1 L
Ideal gas law: PV = nRT, with n = m/M.
Answer: V2 = 0.9647 L
Combined gas law: for a fixed amount of ideal gas, P1V1/T1 = P2V2/T2.
Answer: m = 22 g
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: Y = 91 %
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: [HI] = 0.48 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: [Cl2] = 0.09266 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: Tf = 25.84 °C
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Answer: q = 453.4 kJ
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Answer: t = 15 min
Integrated rate laws: zero order: C = C₀ − kt (straight line, t½ = C₀/(2k)); first order: ln(C₀/C) = kt (t½ = ln 2/k); second order: 1/C − 1/C₀ = kt (t½ = 1/(kC₀)). Conversion X means C = C₀(1 − X).
Answer: T2 = 42.82 °C
Reaction rates: for a first-order reaction −dC/dt = kC, so C = C₀·e−kt and the half-life ln 2/k does not depend on concentration. For a second-order reaction 1/C = 1/C₀ + kt. The rate constant rises with temperature following Arrhenius: k = A·e−Ea/(RT).
Answer: V = 643.8 L
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
Answer: X = 98.1 %
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
Answer: A = 3.581 m²
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
In parallel flow both inlets are at the same end, and both outlets at the other.
Answer: L = 122.8 m
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.
Answer: Ti = −7.038 °C
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
The temperature drops across the first layer by Q̇·R₁.
Answer: Q̇ = 132.9 W
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: hf = 0.3966 m
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
Answer: Q = 77.99 L/s
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
Both surfaces are open to the air and practically at rest, so all of Δz is lost in the pipe.
Answer: Pshaft = 52.97 kW
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Answer: H = 12.54 m
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Both surfaces are open and practically at rest, so pressure and velocity terms drop out.
This is independent practice material. ExamProblems is not affiliated with or endorsed by the organisation that runs this exam, and the exam name is used only to describe the content. The FE exam is run by NCEES, which is not affiliated with ExamProblems and does not endorse it.
ExamProblems · examproblems.com/courses/fe-exam-chemical