In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Series & parallel resistors
Resistors in series
Req = R1 + R2 + …
Resistors in parallel
1/Req = 1/R1 + 1/R2 + …
Two in parallel
Req = R1R2 / (R1 + R2)
Ohm's law
V = I·R
Power
P = V·I = I²R = V²/R
Method
Start at the end of the network furthest from the terminals.
Combine resistors in series by adding them, and resistors in parallel with 1/R = 1/R₁ + 1/R₂ + …
Redraw the circuit after each step.
Repeat until one resistor is left between the terminals.
Nodal analysis
Kirchhoff’s current law
ΣIin = ΣIout
Branch current
I = (Va − Vb)/R
Reference node
Vground = 0
Method
Choose a reference node (ground) and label the other node voltages.
Write Kirchhoff’s current law at every unknown node: currents leaving through each branch equal the currents entering.
Express every branch current as (Va − Vb)/R.
Solve the system of equations, then find any current you need.
Mesh analysis
Kirchhoff’s voltage law
ΣV = 0 around every loop
Shared resistor
current = I1 − I2
Current source in a mesh
fixes that mesh current
Method
Draw a clockwise current in every mesh (window) of the circuit.
Apply Kirchhoff’s voltage law around each mesh: the sum of voltage drops is zero.
In a resistor shared by two meshes the current is the difference of the two mesh currents.
Solve the equations; a negative result means the current flows the other way.
Superposition
Superposition
x = x1 + x2 + … (one source at a time)
Switched-off voltage source
short circuit (0 V)
Switched-off current source
open circuit (0 A)
Voltage divider
V2 = V·R2/(R1 + R2)
Current divider
I1 = I·R2/(R1 + R2)
Method
Count the independent sources. You will solve one simpler circuit per source.
Keep one source and switch off the others: a voltage source becomes a short circuit (a wire), a current source becomes an open circuit (a gap).
Solve the simpler circuit for the voltage or current you need, keeping track of its direction.
Repeat for every source, then add the contributions with their signs.
Thévenin & Norton
Thévenin voltage
Vth = Vopen circuit
Thévenin resistance
Rth: all sources off, seen from a–b
Norton current
IN = Vth/Rth
Load current
IL = Vth/(Rth + RL)
Maximum power transfer
RL = Rth, Pmax = Vth²/(4Rth)
Method
Remove the load and mark the two terminals a and b.
Find the open-circuit voltage between a and b: this is Vth.
Switch off all independent sources and find the resistance seen from a–b: this is Rth.
Put the load back on the equivalent circuit: Vth in series with Rth.
For the Norton equivalent, convert: IN = Vth/Rth, with RN = Rth in parallel.
RC & RL transients
Time constant
τ = RC | τ = L/R
Response
x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ
Capacitor at DC
open circuit; vC cannot jump
Inductor at DC
short circuit; iL cannot jump
Settled
t ≈ 5τ
Method
Find the initial value just after switching: a capacitor voltage and an inductor current cannot jump.
Find the final value long after switching: a capacitor acts as an open circuit, an inductor as a short circuit.
Find the time constant: τ = RC or τ = L/R, using the resistance seen by the capacitor or inductor.
Use x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ.
AC impedance & phasors
Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z
Method
Convert the frequency: ω = 2πf.
Find each reactance: XL = ωL and XC = 1/(ωC).
Add impedances like resistors, with Z = R + jX.
Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.
AC power & power factor
Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)
Three-phase power
Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η
Transformers
Turns ratio
a = N1/N2 = V1/V2
Current ratio
I1/I2 = N2/N1 = 1/a
Rated current
I = S/V
Referred impedance
Z1′ = a²·ZL
Copper loss at part load
Pcu = x²·Pcu,fl
Efficiency
η = x·S·pf/(x·S·pf + Pcore + x²·Pcu,fl)
Maximum efficiency
x = √(Pcore/Pcu,fl)
Op-amp circuits
Inverting amplifier
Vout = −(Rf/Rin)·Vin
Non-inverting amplifier
Vout = (1 + Rf/R1)·Vin
Summing amplifier
Vout = −Rf(V1/R1 + V2/R2)
Ideal op-amp
V+ = V−, Iin = 0
Diodes & transistors
Diode (constant drop)
VD = 0.7 V when conducting
Active region
VBE = 0.7 V, IC = β·IB, IE = (β + 1)·IB
Fixed bias
IB = (VCC − 0.7)/RB
Divider bias
IB = (VTH − 0.7)/(RTH + (β + 1)RE)
Thévenin of the divider
VTH = VCC·R2/(R1 + R2), RTH = R1∥R2
Collector loop
VCE = VCC − ICRC − IERE
Saturation
IC(sat) = (VCC − VCE(sat))/RC, IB ≥ IC(sat)/β
Number systems
Place values
binary 2k, octal 8k, hex 16k
To decimal
Σ dk·bk
From decimal
divide by the base, read the remainders bottom-up
Hex ↔ binary
one hex digit = 4 bits
Two’s complement
invert the bits and add 1
Digital logic: gates, K-maps & flip-flops
Basic gates
A·B, A + B, A′, (A·B)′, (A + B)′, A ⊕ B
Boolean rules
X + X′ = 1, X·X′ = 0, X + XY = X, XY + XY′ = X
De Morgan
(X·Y)′ = X′ + Y′, (X + Y)′ = X′·Y′
Karnaugh map order
00, 01, 11, 10 (Gray code)
Group of 2ᵏ cells
loses k variables
4-to-1 multiplexer
F = A′B′I0 + A′BI1 + AB′I2 + ABI3
Flip-flops
D: Q⁺ = D, T: Q⁺ = T ⊕ Q, JK: Q⁺ = JQ′ + K′Q
Counters
n-bit: 2ⁿ states; mod-N: smallest n with 2ⁿ ≥ N; fout = fclk/N
Ripple counter
fmax = 1/(n·tpd)
Ring and Johnson counters
n and 2n states
Method
For a circuit, work from the inputs to the output one gate at a time and write the value on every wire, or write its expression and fill in the truth table.
For simplification, put the 1s (and the don’t-cares as X) into a Karnaugh map with Gray-code rows and columns: 00, 01, 11, 10.
Cover the 1s with as few and as large groups of 1, 2, 4, 8 or 16 cells as possible, wrapping round the edges; each group is one product term made of the variables that stay constant. Group the 0s for the POS form.
For flip-flops and counters, read the inputs at each active clock edge, write the state after every edge, and remember that an n-bit counter wraps round after 2ⁿ states.
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Series & parallel resistorsMedium
Find the current IR1 delivered by the source, which flows through R1.
V1 = 18 VR1 = 12 ΩR2 = 20 ΩR3 = 8 ΩR4 = 10 Ω
IR1 = A
2.Series & parallel resistorsHard
Find the current IR1 delivered by the source, which flows through R1.
The voltage source Vₛ between A and B has its + terminal at B, so it makes VB − VA = Vₛ. Use nodal analysis with a supernode to find the current Ix through the voltage source, from A to B as shown by the arrow.
Is = 2 AVs = 4 VR1 = 15 ΩR2 = 4 Ω
Ix = A
4.Nodal analysisHard
The voltage source Vₛ between A and B has its + terminal at A, so it makes VA − VB = Vₛ. Use nodal analysis with a supernode to find the current Ix through the voltage source, from A to B as shown by the arrow.
V1 = 9 VIs = 6 AVs = 6 VR1 = 6 ΩR2 = 25 ΩR3 = 8 Ω
Ix = A
5.Mesh analysisMedium
Use mesh analysis to find the mesh current I1 (clockwise).
V1 = 24 VV2 = 15 VR1 = 8 ΩR2 = 20 ΩR3 = 6 Ω
I1 = A
6.Mesh analysisHard
Use mesh analysis to find the current IR2 through R2 in the direction of the arrow.
Find the Thévenin resistance Rth seen from terminals a–b.
V1 = 6 VR1 = 10 ΩR2 = 10 ΩR3 = 4 Ω
Rth = Ω
10.Thévenin & NortonHard
Find the Thévenin voltage Vth seen from terminals a–b.
V1 = 6 VIs = 0.5 AR1 = 5 ΩR2 = 3 ΩR3 = 4 Ω
Vth = V
11.RC & RL transientsMedium
The inductor carries no current before the switch closes at t = 0. Find the current i at t = 5 ms.
Vs = 6 VR = 47 ΩL = 150 mHt = 5 ms
i = A
12.RC & RL transientsHard
The switch across R2 has been open for a long time, so the inductor current is steady. At t = 0 the switch closes and shorts out R2. How long after t = 0 does the inductor current reach 0.386 A? Find t.
Vs = 9 VR1 = 15 ΩR2 = 22 ΩL = 33 mH
t = ms
13.AC impedance & phasorsMedium
A series RLC circuit is connected to a 50 V (rms), 500 Hz supply. Find the real power P taken from the supply.
V = 50 V (rms)f = 500 HzR = 25 ΩL = 100 mHC = 4.7 µF
P = W
14.AC impedance & phasorsHard
A series RLC circuit is connected to a 230 V (rms), 60 Hz supply. Find the rms voltage VC across the capacitor.
V = 230 V (rms)f = 60 HzR = 100 ΩL = 200 mHC = 10 µF
VC = V
15.AC power & power factorMedium
Two loads are connected in parallel to a 230 V single-phase supply: a 13 kW load at a power factor of 0.85 lagging and a 4 kW load at a power factor of 0.9 lagging. Find the overall power factor cos φ seen by the supply.
A 200 kVA single-phase transformer supplies a load of 118 kW at a power factor of 0.75 lagging. How much extra real power ΔP can be added as a resistive (unity power factor) load before the transformer reaches its kVA rating?
Smax = 200 kVAP1 = 118 kWpf1 = 0.75
ΔP = kW
17.Three-phase powerMedium
A balanced three-phase load draws a line current of 80 A from a supply with a line-to-line voltage of 690 V. The power factor is 0.82 lagging. Find the total real power P drawn by the load in kW.
VL = 690 VIL = 80 Acos φ = 0.82
P = kW
18.Three-phase powerHard
A balanced three-phase load takes 300 kW at a power factor of 0.72 lagging from a 400 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.98 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.
P = 300 kWpf1 = 0.72pf2 = 0.98VL = 400 Vf = 50 Hz
Cph = µF
19.TransformersMedium
An amplifier with an output resistance of 640 Ω drives a 10 Ω loudspeaker through an ideal transformer. For maximum power transfer the loudspeaker must look like 640 Ω from the amplifier. Find the turns ratio a = N₁/N₂.
Rs = 640 ΩRL = 10 Ω
a =
20.TransformersHard
A single-phase 500 kVA transformer has a core loss of 2000 W and a copper loss of 6000 W at rated load. It supplies 50% of its rated kVA at a power factor of 0.95 lagging. Find the total losses Ploss in watts at this load.
Choose the feedback resistor Rf that gives this non-inverting amplifier a voltage gain of 15.
R1 = 4.7 kΩAv = 15
Rf = kΩ
22.Op-amp circuitsHard
Two ideal op-amp stages are connected in cascade: an inverting amplifier (R1, Rf1) followed by a non-inverting amplifier (R2 to ground, Rf2 in the feedback). Both run from ±15 V supplies. The input is Vin = 0.55 V. Find the output voltage Vout.
A 3.3 V Zener regulator is fed from 20 V through 270 Ω and supplies a 1500 Ω load. Find the Zener current IZ.
Vin = 20 VVZ = 3.3 VR = 270 ΩRL = 1500 Ω
IZ = mA
24.Diodes & transistorsHard
A 6.2 V Zener regulator has a 220 Ω series resistor. The input can rise to 18 V, and the load may be disconnected. Find the largest power PZ,max the Zener must dissipate.
Vin,max = 18 VVZ = 6.2 VR = 220 Ω
PZ,max = mW
25.Number systemsMedium
Set the bits so they store −67 in 8-bit two's complement. Read as an unsigned number, what is the pattern's value U?
N = −678 bit
U =
26.Number systemsHard
Set the bits to the 8-bit result of 1110 0011 >> 1. What is the result's value R in decimal?
A 4-to-1 multiplexer has its select inputs S₁ = A and S₀ = B, and its data inputs tied to I₀ = C, I₁ = 0, I₂ = C′, I₃ = 0. For how many of the 8 combinations of A, B and C is the output F = 1? Find N.
I₀ = CI₁ = 0I₂ = C′I₃ = 0
N =
28.Digital logic: gates, K-maps & flip-flopsHard
A positive-edge-triggered JK flip-flop starts with Q = 0 and receives the inputs shown. Click the first clock edge at which Q goes from 1 back to 0.
Q₀ = 0JK
1clock edge 1
2clock edge 2
3clock edge 3
4clock edge 4
5clock edge 5
6clock edge 6
7clock edge 7
8clock edge 8
29.Laplace transformsMedium
F(s) = (5s + 9)/(s² + 11s + 30). Its inverse transform has the form f(t) = A·e−5t + B·e−6t. Find the coefficient A by partial fractions.
F(s) = (5s + 9)/(s² + 11s + 30)
A =
30.Laplace transformsHard
Solve y″ + 5y′ + 4y = 0 with y(0) = 1 and y′(0) = 9 using the Laplace transform, and find y(0.25).
y″ + 5y′ + 4y = 0y(0) = 1y′(0) = 9t = 0.25 s
y(0.25) =
31.Block diagramsMedium
A plant G(s) = 5/(s + 9) is controlled in a negative feedback loop whose sensor has the gain H = 0.25. Find the time constant τ of the closed loop.
G(s) = 5/(s + 9)H = 0.25
τ = s
32.Block diagramsHard
The plant G(s) = K/(s(s + 3)(s + 9)) is in a unity negative feedback loop. At the largest stable gain the loop oscillates. Find the frequency of oscillation ω in rad/s.
G(s) = K/(s(s + 3)(s + 9))unity negative feedback
ω = rad/s
33.Step responseMedium
A system has the transfer function G(s) = 87/(s² + 3s + 87) and receives a unit step input. Find the percent overshoot %OS of the step response.
G(s) = 87/(s² + 3s + 87)
%OS = %
34.Step responseHard
A second-order system without zeros must have a step response with 2 % overshoot. Find the damping ratio ζ.
%OS = 2 %
ζ =
35.Bode plots & marginsMedium
In the series RLC band-pass filter shown the output is taken across R = 100 Ω, with L = 50 mH and C = 0.22 µF. Find the quality factor Q.
R = 100 ΩL = 50 mHC = 0.22 µF
Q =
36.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 540/(s(s + 10)). Find the phase margin PM in degrees.
L(s) = 540/(s(s + 10))
PM = °
37.Stability: Routh–Hurwitz & root locusMedium
The plant G(s) = (s + 2)/((s − 2)(s + 2)) has an unstable pole at s = 2. A proportional gain K closes a unity-feedback loop around it. Find the smallest gain Kmin that makes the closed loop stable.
G(s) = (s + 2)/((s − 2)(s + 2))
Kmin =
38.Stability: Routh–Hurwitz & root locusHard
The root locus of L(s) = K/(s(s + 8)) is shown. Find the gain K for which the closed-loop poles have the damping ratio ζ = 0.707.
L(s) = K/(s(s + 8))ζ = 0.707
K =
39.Steady-state error & PID controlMedium
A ramp r(t) = 5t is applied to a unity-feedback loop with G(s) = 2/(s(s + 5)). Find the steady-state error ess.
G(s) = 2/(s(s + 5))r(t) = 5t
ess =
40.Steady-state error & PID controlHard
A proportional controller K = 16 drives the plant G(s) = 4/(s(s + 6)) in a unity-feedback loop. Find the 2 % settling time ts of the step response, using ts ≈ 4/(ζωₙ).
G(s) = 4/(s(s + 6))K = 16
ts = s
3Solutions
1.Series & parallel resistors
Answer: IR1 = 0.8382 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 8 + 10 = 18 Ω
R2 ∥ 18 = 20·18/(20+18) = 9.474 Ω
Req = R1 + 9.474 = 12 + 9.474 = 21.47 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 18/21.47 = 0.8382 A
Answer
IR1 = 0.8382 A
2.Series & parallel resistors
Answer: IR1 = 1.431 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 10 + 15 = 25 Ω
R4 ∥ 25 = 7.143 Ω
R3 + 7.143 = 9.143 Ω
R2 ∥ 9.143 = 4.776 Ω
Req = R1 + 4.776 = 12 + 4.776 = 16.78 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 24/16.78 = 1.431 A
Answer
IR1 = 1.431 A
3.Nodal analysis
Answer: Ix = 1.789 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Form a supernode
The voltage source between A and B carries an unknown current, so KCL cannot be written at A or B separately. Enclose A, B and the source in one supernode: the current entering it equals the current leaving it.
VB = VA + Vs = VA + 4
VA/R1 + VB/R2 = Is
Solve
VA/15 + (VA + 4)/4 = 2
VA = (2 − 4/4)/(1/15 + 1/4) = 3.158 V
VB = 3.158 + 4 = 7.158 V
Current through the voltage source
Everything that passes through the source from A to B leaves node B through R₂.
Ix = VB/R2 = 7.158/4 = 1.789 A
Answer
Ix = 1.789 A
A negative result means the real current flows against the arrow.
4.Nodal analysis
Answer: Ix = −3.641 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Form a supernode
The voltage source between A and B carries an unknown current, so KCL cannot be written at A or B separately. Enclose A, B and the source in one supernode: the current entering it equals the current leaving it.
VB = VA − 6
(VA − V1)/R1 + VA/R2 + VB/R3 = Is
Solve
(VA − 9)/6 + VA/25 + (VA − 6)/8 = 6
VA·(1/6 + 1/25 + 1/8) = 6 + 9/6 + 6/8 = 8.25
VA = 8.25/0.3317 = 24.87 V
VB = 18.87 V
Current through the voltage source
KCL at node A alone: the current arriving through R₁ leaves through R₂ and through the voltage source.
IR1 = (9 − 24.87)/6 = −2.646 A
Ix = IR1 − VA/R2 = −2.646 − 24.87/25 = −3.641 A
Answer
Ix = −3.641 A
A negative result means the real current flows against the arrow.
5.Mesh analysis
Answer: I1 = 1.628 A
Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.
Assign mesh currents
Draw a clockwise current in each window: I1, I2. A resistor shared by two meshes carries the difference of their currents.
KVL around mesh 1
Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).
R1·I1 + R3(I1 − I2) = V1
8·I1 + 6(I1 − I2) = 24
14·I1 − 6·I2 = 24
KVL around mesh 2
Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).
R2·I2 + R3(I2 − I1) = −V2
20·I2 + 6(I2 − I1) = (−15)
−6·I1 + 26·I2 = −15
Solve
Δ = (14)(26) − (−6)(−6) = 328
I1 = Δ1/Δ = 534/328 = 1.628 A
I2 = Δ2/Δ = −66/328 = −0.2012 A
Answer
I1 = 1.628 A
A negative mesh current flows anticlockwise.
6.Mesh analysis
Answer: IR2 = 0.05505 A
Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.
Assign mesh currents
Draw a clockwise current in each window: I1, I2, I3. A resistor shared by two meshes carries the difference of their currents.
KVL around mesh 1
Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).
R1·I1 + R4(I1 − I2) = V1
4·I1 + 8(I1 − I2) = 6
12·I1 − 8·I2 = 6
KVL around mesh 2
Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).
R2·I2 + R4(I2 − I1) + R5(I2 − I3) = 0
3·I2 + 8(I2 − I1) + 25(I2 − I3) = 0
−8·I1 + 36·I2 − 25·I3 = 0
KVL around mesh 3
Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).
R3·I3 + R5(I3 − I2) = −V2
25·I3 + 25(I3 − I2) = (−6)
−25·I2 + 50·I3 = −6
Solve
Δ = det of the coefficient matrix = 10900
I1 = Δ1/Δ = 5850/10900 = 0.5367 A
I2 = Δ2/Δ = 600/10900 = 0.05505 A
I3 = Δ3/Δ = −1008/10900 = −0.09248 A
Answer
IR2 = I2 = 0.05505 A
A negative mesh current flows anticlockwise.
7.Superposition
Answer: PR4 = 32 W
Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.
Case 1 · V1 acting alone
Iₛ becomes an open circuit, so R₃ and R₄ form one series branch from A to ground, in parallel with R₂.
R3+R4 = 4+2 = 6 Ω
R2 ∥ (R3+R4) = 20·6/(20+6) = 4.615 Ω
VA = 10·4.615/(5+4.615) = 4.8 V
VB = VA·R4/(R3+R4) = 4.8·2/6 = 1.6 V
IR4′ = (VB − 0)/R4 = (1.6 − 0)/2 = 0.8 A
Case 2 · Is acting alone
V₁ becomes a short, so R₁ is in parallel with R₂. Iₛ splits at B between R₄ and the path through R₃.
R1 ∥ R2 = 5·20/(5+20) = 4 Ω
Req = R4 ∥ (R3+R1∥R2) = 2 ∥ 8 = 1.6 Ω
VB = Is·Req = 4·1.6 = 6.4 V
VA = VB·(R1∥R2)/(R3+R1∥R2) = 6.4·4/8 = 3.2 V
IR4″ = (VB − 0)/R4 = (6.4 − 0)/2 = 3.2 A
Add the current contributions
IR4 = IR4′ + IR4″ = 0.8 + 3.2 = 4 A
Power in the resistor
Power depends on the square of the current, so it does not obey superposition: add the currents first, then square.
PR4 = IR4²·R4 = 4²·2 = 32 W
Answer
PR4 = 32 W
Adding the powers of the separate cases would give 21.76 W, which is wrong.
8.Superposition
Answer: V2 = 12 V
Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.
Case 1 · V1 acting alone
V₂ becomes a short and Iₛ an open circuit. Seen from A, R₃ is in parallel with the series pair R₂+R₄.
R3 ∥ (R2+R4) = 30 ∥ 20 = 12 Ω
VA = 9·12/(3+12) = 7.2 V
VB = VA·R4/(R2+R4) = 7.2·12/20 = 4.32 V
Case 2 · Is acting alone
Both voltage sources become shorts. Iₛ splits at B between R₄ (now to ground) and R₂ in series with R₁ ∥ R₃. The arrow of Iₛ points down, away from its node, so Iₛ draws current out of that node: its term enters with a minus sign.
R1 ∥ R3 = 2.727 Ω, so the left path is R2+2.727 = 10.73 Ω
Req = R4 ∥ 10.73 = 5.664 Ω
VB = −Is·Req = −6·5.664 = −33.98 V
VA = VB·2.727/10.73 = −8.64 V
Case 3 · V2 acting alone, per volt
V₁ becomes a short and Iₛ an open circuit. R₁ ∥ R₃ hangs from A, in series with R₂ back to B.
R1 ∥ R3 = 2.727 Ω
VA‴ = V2·2.727/(12 + 8 + 2.727) = 0.12·V2
Set VA to zero
With VA = 0 there is no voltage across R₃, so its current is zero.
VA′ + VA″ + VA‴ = 7.2 + (−8.64) + 0.12·V2 = 0
V2 = 1.44/0.12 = 12 V
Answer
V2 = 12 V
9.Thévenin & Norton
Answer: Rth = 9 Ω
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 10·10/(10+10) = 5 Ω
Rth = (R1 ∥ R2) + R3 = 5 + 4 = 9 Ω
10.Thévenin & Norton
Answer: Vth = −0.6875 V
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 5·3/(5+3) = 1.875 Ω
Rth = (R1 ∥ R2) + R3 = 1.875 + 4 = 5.875 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 2.25 + (−0.5)·1.875 = 1.313 V
Vth = VB = VA + Is·R3 = 1.313 + (−0.5)·4 = −0.6875 V
11.RC & RL transients
Answer: i = 0.101 A
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant and final current
Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
Before t = 0 both resistors are in the loop; afterwards the closed switch bypasses R₂.
i(0) = 9/(15 + 22) = 0.2432 A
i(∞) = 9/15 = 0.6 A
τ = L/R = 33/15 = 2.2 ms
i(t) = 0.6 + (0.2432 − 0.6)·e−t/τ
Solve for the time
e−t/τ = (0.386 − 0.6)/(0.2432 − 0.6) = 0.5998
t = 2.2·ln(1.667) = 1.124 ms
Answer
t = 1.124 ms
13.AC impedance & phasors
Answer: P = 1.019 W
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
XL = 314.2 Ω, XC = 67.73 Ω
Impedance
|Z| = √(25² + (246.4)²) = 247.7 Ω
Real power
Inductors and capacitors only store and return energy; the resistor absorbs all of the real power.
I = 50/247.7 = 0.2019 A
P = I²·R = 0.2019²·25 = 1.019 W
Answer
P = 1.019 W
14.AC impedance & phasors
Answer: VC = 284.3 V
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
ω = 2πf = 2π·60 = 377 rad/s
XL = ωL = 377·0.2 = 75.4 Ω
XC = 1/(ωC) = 1/(377·10·10⁻⁶) = 265.3 Ω
Impedance
In series the impedances add as complex numbers: Z = R + j(XL − XC).
The same current flows through every element of a series circuit.
I = V/|Z| = 230/214.6 = 1.072 A
Voltage across the capacitor
VC = I·XC = 1.072·265.3 = 284.3 V
Answer
VC = 284.3 V
15.AC power & power factor
Answer: cos φ = 0.8621
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power of each load
A lagging load takes reactive power (Q > 0); a leading load supplies it (Q < 0).
Q1 = 13·tan(arccos 0.85) = 8.057 kvar
Q2 = 4·tan(arccos 0.9) = 1.937 kvar
Totals
P = 13 + 4 = 17 kW
Q = 8.057 + 1.937 = 9.994 kvar
S = √(17² + 9.994²) = 19.72 kVA
Overall power factor
cos φ = P/S = 17/19.72 = 0.8621 lagging
Answer
cos φ = 0.8621
16.AC power & power factor
Answer: ΔP = 52.79 kW
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power of the existing load
Q1 = 118·tan(arccos 0.75) = 104.1 kvar
Largest total real power
At full rating S = Smax, and Q is unchanged by the resistive load.
P = √(Smax² − Q1²) = √(200² − 104.1²) = 170.8 kW
Extra real power
ΔP = 170.8 − 118 = 52.79 kW
Answer
ΔP = 52.79 kW
17.Three-phase power
Answer: P = 78.4 kW
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Apparent power
S = √3·VL·IL = √3·690·80 = 95.61 kVA
Real power
P = S·cos φ = 95.61·0.82 = 78.4 kW
Answer
P = 78.4 kW
18.Three-phase power
Answer: Cph = 1514 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 300·tan(acos 0.72) = 300·0.9639 = 289.2 kvar
Q2 = 300·tan(acos 0.98) = 300·0.2031 = 60.92 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 228.2 kvar
Capacitance per phase
In a Δ bank each capacitor is connected between two lines.
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Match the referred load
a²·10 = 640
a = √(640/10) = √64 = 8
Answer
a = 8
20.Transformers
Answer: Ploss = 3500 W
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.
Copper loss at this load
Pcu = x²·Pcu,fl = 0.25·6000 = 1500 W
Total losses
The core loss is the same at any load.
Ploss = 2000 + 1500 = 3500 W
Answer
Ploss = 3500 W
The efficiency at this load is η = 98.55%.
21.Op-amp circuits
Answer: Rf = 65.8 kΩ
Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.
Gain of a non-inverting amplifier
V₋ = V₊ = Vin, and the current through R₁ also flows through Rf, so Vout = Vin·(1 + Rf/R₁).
Av = 1 + Rf/R1
Rf = (15 − 1)·4.7 = 65.8 kΩ
Answer
Rf = 65.8 kΩ
22.Op-amp circuits
Answer: Vout = −1.65 V
Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.
Gain of each stage
A1 = −Rf1/R1 = −2/1 = −2
A2 = 1 + Rf2/R2 = 1 + 1/2 = 1.5
Stage by stage
V1 = −2·0.55 = −1.1 V
Vout = 1.5·(−1.1) = −1.65 V
Answer
Vout = −1.65 V
23.Diodes & transistors
Answer: IZ = 59.65 mA
Zener regulator: a reverse-biased Zener diode holds its voltage VZ while its current stays above a minimum IZ,min. The series resistor R takes the difference between input and output: IR = (Vin − VZ)/R. That current splits between the load, IL = VZ/RL, and the Zener: IZ = IR − IL. Design for the worst cases: the lowest input with the largest load must still leave IZ,min, and the highest input with no load gives the largest Zener power PZ = VZ·IZ.
Resistor current
IR = 16.7/270 = 61.85 mA
Load current
IL = 3.3/1500 = 2.2 mA
Zener current
IZ = 61.85 − 2.2 = 59.65 mA
Answer
IZ = 59.65 mA
24.Diodes & transistors
Answer: PZ,max = 332.5 mW
Zener regulator: a reverse-biased Zener diode holds its voltage VZ while its current stays above a minimum IZ,min. The series resistor R takes the difference between input and output: IR = (Vin − VZ)/R. That current splits between the load, IL = VZ/RL, and the Zener: IZ = IR − IL. Design for the worst cases: the lowest input with the largest load must still leave IZ,min, and the highest input with no load gives the largest Zener power PZ = VZ·IZ.
Worst-case Zener current
IZ = 11.8/220 = 53.64 mA
Zener power
PZ = 6.2·53.64 = 332.5 mW
Answer
PZ,max = 332.5 mW
25.Number systems
Answer: U = 189
Setting bits: each bit is worth a power of two (128, 64, …, 1). One hex digit is exactly four bits, and in 8-bit two's complement the leftmost bit is worth −128. Bitwise operations work on each bit position separately.
Invert and add one
67 = 0100 0011
inverted: 1011 1100
+1 → 1011 1101
Read it as unsigned
1011 1101₂ = 256 − 67 = 189
Answer
U = 189
26.Number systems
Answer: R = 113
Setting bits: each bit is worth a power of two (128, 64, …, 1). One hex digit is exactly four bits, and in 8-bit two's complement the leftmost bit is worth −128. Bitwise operations work on each bit position separately.
Bit by bit
Shifting right by 1 moves every bit 1 places to the right; bits that fall off the right end are lost and zeros come in on the left.
1110 0011 >> 1
= 0111 0001
Value of the result
0111 0001₂ = 113
Answer
R = 113
27.Digital logic: gates, K-maps & flip-flops
Answer: N = 2
Multiplexer: a 2ⁿ-to-1 multiplexer passes one of its data inputs to the output; the select lines, read as a binary number, pick which one. For a 4-to-1 MUX with selects S₁S₀ = AB, F = A′B′·I₀ + A′B·I₁ + AB′·I₂ + AB·I₃. Tying the data inputs to 0, 1, C or C′ makes the MUX produce any function of A, B and C, which is a common way to build logic with one chip.
Output expression
F = A′B′C + AB′C′
Rows with F = 1
ABC = 001, 100
N = 2
Answer
N = 2
28.Digital logic: gates, K-maps & flip-flops
Answer: clock edge 5
Flip-flops and counters: a flip-flop changes only at the active clock edge. D copies its input (Q⁺ = D); T toggles when T = 1; JK holds for 00, resets for 01, sets for 10 and toggles for 11. An n-bit binary counter has 2ⁿ states and counts modulo 2ⁿ; a mod-N counter goes 0, 1, …, N − 1 and back to 0, and needs the smallest n with 2ⁿ ≥ N flip-flops. Each stage of a ripple counter halves the frequency, so the last output of a mod-N counter runs at fclk/N. A Johnson counter of n flip-flops has 2n states, a ring counter n.
Q after every edge
A JK flip-flop: 00 holds, 01 resets (Q = 0), 10 sets (Q = 1), 11 toggles.
1: J = 0, K = 1 → Q = 0
2: J = 1, K = 1 → Q = 1
3: J = 1, K = 0 → Q = 1
4: J = 0, K = 0 → Q = 1
5: J = 0, K = 1 → Q = 0
6: J = 0, K = 0 → Q = 0
7: J = 0, K = 1 → Q = 0
8: J = 0, K = 0 → Q = 0
First change from 1 to 0
clock edge 5
Answer
clock edge 5
29.Laplace transforms
Answer: A = −16
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Factor the denominator
s² + 11s + 30 = (s + 5)(s + 6)
F(s) = A/(s + 5) + B/(s + 6)
Cover-up rule
Multiply by (s + 5) and set s = −5: the B-term vanishes.
A = (5s + 9)/(s + 6) |s = −5 = −16/1 = −16
Answer
A = −16
(B = 21, so f(t) = −16·e−5t + 21·e−6t)
30.Laplace transforms
Answer: y(0.25) = 2.149
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transform the equation
s²Y − 1s − 9 + 5(sY − 1) + 4Y = 0
Y(s) = (s + 14)/((s + 1)(s + 4))
Partial fractions
A = 13/3 = 4.333
B = 10/(−3) = −3.333
Result
y(t) = 4.333·e−t − 3.333·e−4t
y(0.25) = 2.149
Answer
y(0.25) = 2.149
Check: y(0) = A + B = 1.
31.Block diagrams
Answer: τ = 0.09756 s
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Characteristic equation
s³ + 12s² + 27s + K = 0
Routh array
s³ | 1 27
s² | 12 K
s¹ | (12·27 − K)/12
s⁰ | K
Stability limit
All entries of the first column must be positive.
Kmax = 12·27 = 324
Frequency of oscillation
12·(jω)² + 324 = 0 → ω² = 324/12 = 27
ω = 5.196 rad/s
Answer
ω = 5.196 rad/s
33.Step response
Answer: %OS = 59.94 %
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 87 → ωₙ = 9.327 rad/s
2ζωₙ = 3 → ζ = 3/(2·9.327) = 0.1608
Result
%OS = 100·e−ζπ/√(1−ζ²) = 100·e−0.5119 = 59.94 %
Answer
%OS = 59.94 %
34.Step response
Answer: ζ = 0.7797
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Resonant frequency
ω₀ = 1/√(LC) = 1/√(0.05·2.2 × 10⁻⁷) = 9535 rad/s
f₀ = ω₀/(2π) = 1517 Hz
Quality factor
BW = R/L = 100/0.05 = 2000 rad/s = 318.3 Hz
Q = ω₀/BW = 9535/2000 = 4.767
Answer
Q = 4.767
36.Bode plots & margins
Answer: PM = 24.26 °
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Gain crossover
ω⁴ + 100ω² − 291600 = 0
ω² = (−100 + √(10000 + 4·291600))/2 = 492.3
ωc = 22.19 rad/s
Phase margin
∠L(jωc) = −90° − atan(22.19/10) = −155.7°
PM = 180° + ∠L = 24.26°
Answer
PM = 24.26°
37.Stability: Routh–Hurwitz & root locus
Answer: Kmin = 2
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
For s² + c₁s + c₀ all roots lie in the left half-plane exactly when c₁ > 0 and c₀ > 0.
0 + K > 0 → K > 0
2K − 4 > 0 → K > 2
Kmin = 2
Answer
Kmin = 2
38.Stability: Routh–Hurwitz & root locus
Answer: K = 32.01
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Compare with the standard form
s² + 8s + K = s² + 2ζωₙs + ωₙ²
2·0.707·ωₙ = 8 → ωₙ = 5.658 rad/s
Gain
K = ωₙ² = 5.658² = 32.01
Answer
K = 32.01
The closed-loop poles sit where the ζ line crosses the vertical branch at s = −4.
39.Steady-state error & PID control
Answer: ess = 12.5
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Velocity constant
Kv = lim s·G(s) = 0.4
Ramp error
ess = 5/0.4 = 12.5
Answer
ess = 12.5
40.Steady-state error & PID control
Answer: ts = 1.333 s
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
s(s + 6) + 16·4 = s² + 6s + 64
ωₙ and ζ
ωₙ = √64 = 8 rad/s
ζ = 6/(2·8) = 0.375
Settling time
ζωₙ = 6/2 = 3
ts ≈ 4/3 = 1.333 s
Answer
ts = 1.333 s
The settling time does not depend on K here: raising K only makes the response oscillate faster.