Series & parallel resistors

Resistors in series
Req = R1 + R2 + …
Resistors in parallel
1/Req = 1/R1 + 1/R2 + …
Two in parallel
Req = R1R2 / (R1 + R2)
Ohm's law
V = I·R
Power
P = V·I = I²R = V²/R

Method

  1. Start at the end of the network furthest from the terminals.
  2. Combine resistors in series by adding them, and resistors in parallel with 1/R = 1/R₁ + 1/R₂ + …
  3. Redraw the circuit after each step.
  4. Repeat until one resistor is left between the terminals.

Nodal analysis

Kirchhoff’s current law
ΣIin = ΣIout
Branch current
I = (Va − Vb)/R
Reference node
Vground = 0

Method

  1. Choose a reference node (ground) and label the other node voltages.
  2. Write Kirchhoff’s current law at every unknown node: currents leaving through each branch equal the currents entering.
  3. Express every branch current as (Va − Vb)/R.
  4. Solve the system of equations, then find any current you need.

Mesh analysis

Kirchhoff’s voltage law
ΣV = 0 around every loop
Shared resistor
current = I1 − I2
Current source in a mesh
fixes that mesh current

Method

  1. Draw a clockwise current in every mesh (window) of the circuit.
  2. Apply Kirchhoff’s voltage law around each mesh: the sum of voltage drops is zero.
  3. In a resistor shared by two meshes the current is the difference of the two mesh currents.
  4. Solve the equations; a negative result means the current flows the other way.

Superposition

Superposition
x = x1 + x2 + … (one source at a time)
Switched-off voltage source
short circuit (0 V)
Switched-off current source
open circuit (0 A)
Voltage divider
V2 = V·R2/(R1 + R2)
Current divider
I1 = I·R2/(R1 + R2)

Method

  1. Count the independent sources. You will solve one simpler circuit per source.
  2. Keep one source and switch off the others: a voltage source becomes a short circuit (a wire), a current source becomes an open circuit (a gap).
  3. Solve the simpler circuit for the voltage or current you need, keeping track of its direction.
  4. Repeat for every source, then add the contributions with their signs.

Thévenin & Norton

Thévenin voltage
Vth = Vopen circuit
Thévenin resistance
Rth: all sources off, seen from a–b
Norton current
IN = Vth/Rth
Load current
IL = Vth/(Rth + RL)
Maximum power transfer
RL = Rth, Pmax = Vth²/(4Rth)

Method

  1. Remove the load and mark the two terminals a and b.
  2. Find the open-circuit voltage between a and b: this is Vth.
  3. Switch off all independent sources and find the resistance seen from a–b: this is Rth.
  4. Put the load back on the equivalent circuit: Vth in series with Rth.
  5. For the Norton equivalent, convert: IN = Vth/Rth, with RN = Rth in parallel.

RC & RL transients

Time constant
τ = RC | τ = L/R
Response
x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ
Capacitor at DC
open circuit; vC cannot jump
Inductor at DC
short circuit; iL cannot jump
Settled
t ≈ 5τ

Method

  1. Find the initial value just after switching: a capacitor voltage and an inductor current cannot jump.
  2. Find the final value long after switching: a capacitor acts as an open circuit, an inductor as a short circuit.
  3. Find the time constant: τ = RC or τ = L/R, using the resistance seen by the capacitor or inductor.
  4. Use x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ.

AC impedance & phasors

Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z

Method

  1. Convert the frequency: ω = 2πf.
  2. Find each reactance: XL = ωL and XC = 1/(ωC).
  3. Add impedances like resistors, with Z = R + jX.
  4. Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.

AC power & power factor

Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)

Three-phase power

Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η

Transformers

Turns ratio
a = N1/N2 = V1/V2
Current ratio
I1/I2 = N2/N1 = 1/a
Rated current
I = S/V
Referred impedance
Z1′ = a²·ZL
Copper loss at part load
Pcu = x²·Pcu,fl
Efficiency
η = x·S·pf/(x·S·pf + Pcore + x²·Pcu,fl)
Maximum efficiency
x = √(Pcore/Pcu,fl)

Op-amp circuits

Inverting amplifier
Vout = −(Rf/Rin)·Vin
Non-inverting amplifier
Vout = (1 + Rf/R1)·Vin
Summing amplifier
Vout = −Rf(V1/R1 + V2/R2)
Ideal op-amp
V+ = V−, Iin = 0

Diodes & transistors

Diode (constant drop)
VD = 0.7 V when conducting
Active region
VBE = 0.7 V, IC = β·IB, IE = (β + 1)·IB
Fixed bias
IB = (VCC − 0.7)/RB
Divider bias
IB = (VTH − 0.7)/(RTH + (β + 1)RE)
Thévenin of the divider
VTH = VCC·R2/(R1 + R2), RTH = R1∥R2
Collector loop
VCE = VCC − ICRC − IERE
Saturation
IC(sat) = (VCC − VCE(sat))/RC, IB ≥ IC(sat)/β

Number systems

Place values
binary 2k, octal 8k, hex 16k
To decimal
Σ dk·bk
From decimal
divide by the base, read the remainders bottom-up
Hex ↔ binary
one hex digit = 4 bits
Two’s complement
invert the bits and add 1

Digital logic: gates, K-maps & flip-flops

Basic gates
A·B, A + B, A′, (A·B)′, (A + B)′, A ⊕ B
Boolean rules
X + X′ = 1, X·X′ = 0, X + XY = X, XY + XY′ = X
De Morgan
(X·Y)′ = X′ + Y′, (X + Y)′ = X′·Y′
Karnaugh map order
00, 01, 11, 10 (Gray code)
Group of 2ᵏ cells
loses k variables
4-to-1 multiplexer
F = A′B′I0 + A′BI1 + AB′I2 + ABI3
Flip-flops
D: Q⁺ = D, T: Q⁺ = T ⊕ Q, JK: Q⁺ = JQ′ + K′Q
Counters
n-bit: 2ⁿ states; mod-N: smallest n with 2ⁿ ≥ N; fout = fclk/N
Ripple counter
fmax = 1/(n·tpd)
Ring and Johnson counters
n and 2n states

Method

  1. For a circuit, work from the inputs to the output one gate at a time and write the value on every wire, or write its expression and fill in the truth table.
  2. For simplification, put the 1s (and the don’t-cares as X) into a Karnaugh map with Gray-code rows and columns: 00, 01, 11, 10.
  3. Cover the 1s with as few and as large groups of 1, 2, 4, 8 or 16 cells as possible, wrapping round the edges; each group is one product term made of the variables that stay constant. Group the 0s for the POS form.
  4. For flip-flops and counters, read the inputs at each active clock edge, write the state after every edge, and remember that an n-bit counter wraps round after 2ⁿ states.

Stability: Routh–Hurwitz & root locus

Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)

Method

  1. Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
  2. Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
  3. Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
  4. For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.

Steady-state error & PID control

System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)

Method

  1. Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
  2. Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
  3. Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
  4. For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².

2Practice problems

1.Series & parallel resistorsMedium
R1​ = 8 ΩIR1​R3​ = 15 Ω+−V1​24 VR2​12 ΩAR4​6 ΩB

Find the current IR1 delivered by the source, which flows through R1.

V1 = 24 VR1 = 8 ΩR2 = 12 ΩR3 = 15 ΩR4 = 6 Ω
IR1 = A
2.Series & parallel resistorsHard
R1​ = 12 ΩR3​ = 8 ΩR5​ = 15 Ω+−V1​12 VR2​5 ΩAR4​4 ΩBR6​2 Ω

Find the equivalent resistance Req seen by the source V1.

V1 = 12 VR1 = 12 ΩR2 = 5 ΩR3 = 8 ΩR4 = 4 ΩR5 = 15 ΩR6 = 2 Ω
Req = Ω
3.Nodal analysisMedium
R1​ = 4 ΩIR1​R3​ = 5 Ω+−V1​10 VR2​5 ΩAR4​6 ΩBIs​4 A

Use nodal analysis to find the current IR1 through R1 in the direction of the arrow.

V1 = 10 VIs = 4 AR1 = 4 ΩR2 = 5 ΩR3 = 5 ΩR4 = 6 Ω
IR1 = A
4.Nodal analysisHard
R1​ = 15 ΩIR1​R2​ = 6 ΩR4​ = 30 Ω+−V1​36 VR3​15 ΩAR5​30 ΩBIs​6 A−+V2​18 V

Use nodal analysis to find the current IR1 through R1 in the direction of the arrow.

V1 = 36 VIs = 6 AV2 = 18 VR1 = 15 ΩR2 = 6 ΩR3 = 15 ΩR4 = 30 ΩR5 = 30 Ω
IR1 = A
5.Mesh analysisMedium
R1​ = 20 ΩR2​ = 20 Ω+−V1​18 VR3​4 ΩIR3​A+−V2​10 VI1​I2​

Use mesh analysis to find the current IR3 through R3 in the direction of the arrow.

V1 = 18 VV2 = 10 VR1 = 20 ΩR2 = 20 ΩR3 = 4 Ω
IR3 = A
6.Mesh analysisHard
R1​ = 30 ΩR2​ = 25 ΩR3​ = 10 Ω+−VR3​+−V1​6 VR4​2 ΩAR5​25 ΩB+−V2​5 VI1​I2​I3​

Use mesh analysis to find the voltage VR3 across R3 with the polarity shown.

V1 = 6 VV2 = 5 VR1 = 30 ΩR2 = 25 ΩR3 = 10 ΩR4 = 2 ΩR5 = 25 Ω
VR3 = V
7.SuperpositionMedium
R1​ = 10 ΩR3​ = 10 ΩIR3​+−V1​15 VR2​20 ΩAR4​8 ΩBIs​?

Find the value of the current source Is (direction as shown) that makes the current IR3 through R3 equal to zero.

V1 = 15 VR1 = 10 ΩR2 = 20 ΩR3 = 10 ΩR4 = 8 Ω
Is = A
8.SuperpositionHard
R1​ = 8 ΩR2​ = 20 ΩR4​ = 25 Ω+−V1​10 VR3​25 Ω−+VR3​AIs​2.5 AB+−V2​9 V

Use superposition to find the voltage VR3 across R3 with the polarity shown.

V1 = 10 VIs = 2.5 AV2 = 9 VR1 = 8 ΩR2 = 20 ΩR3 = 25 ΩR4 = 25 Ω
VR3 = V
9.Thévenin & NortonMedium
R1​ = 3 ΩR3​ = 6 Ω+−V1​18 VR2​12 ΩARL​15 ΩIL​B

A load RL = 15 Ω is connected across a–b. Replace the rest of the circuit with its Thévenin equivalent and find the load current IL.

V1 = 18 VR1 = 3 ΩR2 = 12 ΩR3 = 6 ΩRL = 15 Ω
IL = A
10.Thévenin & NortonHard
R1​ = 15 ΩR3​ = 3 Ω+−V1​18 VR2​20 ΩAIs​2.5 ABRL​20 ΩIL​

A load RL = 20 Ω is connected across a–b. Use a Thévenin equivalent to find the power PL delivered to the load.

V1 = 18 VIs = 2.5 AR1 = 15 ΩR2 = 20 ΩR3 = 3 ΩRL = 20 Ω
PL = W
11.RC & RL transientsMedium
+−Vs​12 Vt = 0R1​ = 10 kΩR2​ = 6.8 kΩC68 µF+−vC​

The source Vₛ charges the capacitor through R₁, and R₂ is connected in parallel with C. The capacitor is uncharged when the switch closes at t = 0. Find the capacitor voltage vC at t = 250 ms.

Vs = 12 VR1 = 10 kΩR2 = 6.8 kΩC = 68 µFt = 250 ms
vC = V
12.RC & RL transientsHard
+−Vs​6 VR1​ = 22 ΩR2​ = 20 Ωcloses at t = 0L22 mHi(t)

The switch across R2 has been open for a long time, so the inductor current is steady. At t = 0 the switch closes and shorts out R2. Find the inductor current i at t = 1 ms.

Vs = 6 VR1 = 22 ΩR2 = 20 ΩL = 22 mHt = 1 ms
i = A
13.AC impedance & phasorsMedium
24 V500 HzR = 50 ΩL = 100 mHC = 4.7 µFI

A series RLC circuit is connected to a 24 V (rms), 500 Hz supply. Find the real power P taken from the supply.

V = 24 V (rms)f = 500 HzR = 50 ΩL = 100 mHC = 4.7 µF
P = W
14.AC impedance & phasorsHard
24 V200 HzR1​ = 15 ΩR2​ = 30 ΩC = 47 µF

A resistor R1 is connected in series with a parallel combination of R2 and a capacitor C, across a 24 V (rms), 200 Hz supply. Find the magnitude of the impedance |Z|.

V = 24 V (rms)f = 200 HzR1 = 15 ΩR2 = 30 ΩC = 47 µF
|Z| = Ω
15.AC power & power factorMedium
P = 7 kWQSφ

A single-phase motor takes 7 kW at a power factor of 0.65 lagging from a 240 V supply. Find the line current I.

P = 7 kWpf = 0.65V = 240 V
I = A
16.AC power & power factorHard
230 V60 HzRs​ = 25 ΩXs​ = j10 ΩZL​ = ?

A 230 V (rms), 60 Hz source has an internal impedance Zs = 25 + j10 Ω. The load impedance ZL can be chosen freely. Find the maximum real power Pmax that can be delivered to the load.

Vs = 230 V (rms)f = 60 HzZs = 25 + j10 Ω
Pmax = W
17.Three-phase powerMedium
ABCVL​ = 208 VZ = 9 + j12 Ωper phase

A balanced Δ-connected load with an impedance of 9 + j12 Ω per phase is connected to a balanced three-phase supply with a line-to-line voltage of 208 V. Find the total real power P absorbed by the load in kW.

VL = 208 VZ = 9 + j12 Ω per phase
P = kW
18.Three-phase powerHard
P = 100 kWφ1​S1​Q2​QC​

A balanced three-phase load takes 100 kW at a power factor of 0.65 lagging from a 480 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.95 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.

P = 100 kWpf1 = 0.65pf2 = 0.95VL = 480 Vf = 60 Hz
Cph = µF
19.TransformersMedium
16 Ω81

A 16 Ω resistor is connected across the secondary winding of an ideal transformer with a turns ratio N₁:N₂ = 8:1. Find the resistance R1′ seen looking into the primary winding.

N1:N2 = 8:1RL = 16 Ω
R1′ = Ω
20.TransformersHard
250 kVA

A single-phase 250 kVA transformer has a core loss of 750 W and a copper loss of 1875 W at rated load. At what load Sη,max, in kVA, is its efficiency highest?

S = 250 kVAPcore = 750 WPcu,fl = 1875 W
Sη,max = kVA
21.Op-amp circuitsMedium
−+Vout​Rf​ = 47 kΩR1​ = 47 kΩVin​ = −1.4 V

The op-amp is ideal and runs from ±15 V supplies. Find the output voltage Vout.

Vin = −1.4 VR1 = 47 kΩRf = 47 kΩ
Vout = V
22.Op-amp circuitsHard
−+Vout​C = 0.22 µFVin​ = 1.2 VR = 47 kΩ

The integrator uses an ideal op-amp with ±15 V supplies; its output saturates at ±13 V. The capacitor is uncharged when a constant input Vin = 1.2 V is applied at t = 0. Find the output voltage Vout at t = 20 ms.

Vin = 1.2 VR = 47 kΩC = 0.22 µFVsat = ±13 Vt = 20 ms
Vout = V
23.Diodes & transistorsMedium
+−15 V330 Ω5.6 V470 ΩIZ​ = ?

A 5.6 V Zener regulator is fed from 15 V through 330 Ω and supplies a 470 Ω load. Find the Zener current IZ.

Vin = 15 VVZ = 5.6 VR = 330 ΩRL = 470 Ω
IZ = mA
24.Diodes & transistorsHard
RC​ = 680 Ωβ = 50IC​ = ?VCC​ = 12 V5 VRB​ = 1 kΩ

An NPN transistor with β = 50 switches a 680 Ω load resistor connected between VCC = 12 V and its collector. The emitter is grounded. The base is driven from a 5 V logic output through a base resistor RB = 1 kΩ. Take VBE = 0.7 V and VCE(sat) = 0.2 V. Find the collector current IC in mA when the input is high. Decide first whether the transistor is saturated.

VCC = 12 VRC = 680 Ωβ = 50Vin = 5 VVBE = 0.7 VVCE(sat) = 0.2 VRB = 1 kΩ
IC = mA
25.Number systemsMedium
place values in two's complement1−12806403201618040201

The 8-bit pattern 1000 1000 stores a signed integer in two's complement. What is its value N in decimal?

1000 10008 bit
N =
26.Number systemsHard
click the bits to set them012806403201608040201

Set the bits to the 8-bit result of 1100 1111 XOR 0111 1010. What is the result's value R in decimal?

1100 1111XOR0111 1010
R =
27.Digital logic: gates, K-maps & flip-flopsMedium
ABCD000111100001111000011302040517160120130151140809011110

Use the Karnaugh map to find the minimal sum-of-products (SOP) form of F(A, B, C, D) = Σm(3, 6, 7, 10, 14). How many product terms N does it have?

F(A, B, C, D) = Σm(3, 6, 7, 10, 14)
N =
28.Digital logic: gates, K-maps & flip-flopsHard
ABCD00011110000111100011030204X507161121130150140819X11110

Find the minimal SOP form of F(A, B, C, D) = Σm(1, 6, 9, 10, 12, 13) + d(5, 11), where d marks the don't-care conditions. How many literals L does it contain?

F(A, B, C, D) = Σm(1, 6, 9, 10, 12, 13) + d(5, 11)
L =
29.Laplace transformsMedium
t (s)f(t)t = 0.5f(0.5) = ?

Find f(t) for F(s) = (4s + 4)/(s² + 4s + 4) and evaluate f(0.5).

F(s) = (4s + 4)/(s² + 4s + 4)t = 0.5 s
f(0.5) =
30.Laplace transformsHard
t (s)y(t)t = 1.2y(1.2) = ?

Solve y″ + 7y′ + 6y = 0 with y(0) = 10 and y′(0) = 15 using the Laplace transform, and find y(1.2).

y″ + 7y′ + 6y = 0y(0) = 10y′(0) = 15t = 1.2 s
y(1.2) =
31.Block diagramsMedium
R(s)+6K+4s + 6G(s)C(s)2H₁−−

The plant G(s) = 4/(s + 6) has an inner (minor) negative feedback loop with gain H₁ = 2. A controller gain K = 6 and an outer unity negative feedback loop close the system. Find the closed-loop DC gain T(0).

G(s) = 4/(s + 6)H₁ = 2K = 6
T(0) =
32.Block diagramsHard
R(s)+Ks(s + 5)(s + 8)G(s)C(s)−

The plant G(s) = K/(s(s + 5)(s + 8)) is in a unity negative feedback loop. Use the Routh–Hurwitz criterion to find the largest gain Kmax for which the closed loop is stable.

G(s) = K/(s(s + 5)(s + 8))unity negative feedback
Kmax =
33.Step responseMedium
t (s)y(t)3?

A system has the transfer function G(s) = 72/(s² + 2s + 24) and receives a unit step input. Find the percent overshoot %OS of the step response.

G(s) = 72/(s² + 2s + 24)
%OS = %
34.Step responseHard
+−10 VR = 52 ΩL = 20 mHC = 4.7 µFvC​

A series RLC circuit with R = 52 Ω, L = 20 mH and C = 4.7 µF is connected to a 10 V step at t = 0. The capacitor is uncharged and no current flows before the step. Find the percent overshoot %OS of the capacitor voltage.

R = 52 ΩL = 20 mHC = 4.7 µFV = 10 V
%OS = %
35.Bode plots & marginsMedium
|H| (dB)0.10.111101010010010001000−40−200204060ω (rad/s)φ (°)ω (rad/s)−135−90−450ω = 20

Find the phase ∠G(jω) of G(s) = 23(s + 16)/(s(s + 6)) at ω = 20 rad/s, in degrees.

G(s) = 23(s + 16)/(s(s + 6))ω = 20 rad/s
∠G(jω) = °
36.Bode plots & marginsHard
|H| (dB)0.10.1111010100100−80−60−40−2002040ω (rad/s)φ (°)ω (rad/s)−270−180−900ω180​

A unity-feedback loop has the open-loop transfer function L(s) = 60/(s(s + 3)(s + 5)). Find the gain margin GM in dB.

L(s) = 60/(s(s + 3)(s + 5))
GM = dB
37.Stability: Routh–Hurwitz & root locusMedium
R(s)+101s(s + 1)(s + 6)C(s)+

The loop in the diagram uses positive feedback, with L(s) = 10/(s(s + 1)(s + 6)). How many closed-loop poles N lie in the right half-plane?

L(s) = 10/(s(s + 1)(s + 6))
N =
38.Stability: Routh–Hurwitz & root locusHard
ReIm−0.5−1−1.5−2−2.5−3−3.5−40.5j0.5j1−1.5

For the loop L(s) = K/(s(s + 2)(s + 3)), find the gain K that puts a closed-loop pole at s = −1.5.

L(s) = K/(s(s + 2)(s + 3))s = −1.5
K =
39.Steady-state error & PID controlMedium
R(s)+K = 200.510s + 1C(s)−

A process G(s) = 0.5/(10s + 1) is controlled by a proportional gain K = 20 in a unity-feedback loop. Find the steady-state error ess for a step, as a percentage of the step size.

G(s) = 0.5/(10s + 1)K = 20
ess = %
40.Steady-state error & PID controlHard
r(t) = 1t+5 + 0.5/s10(s + 1)(s + 5)C(s)−

A PI controller C(s) = 5 + 0.5/s drives the plant G(s) = 10/((s + 1)(s + 5)) in a unity-feedback loop. Find the steady-state error ess for the ramp input r(t) = 1t.

C(s) = 5 + 0.5/sG(s) = 10/((s + 1)(s + 5))r(t) = 1t
ess =

3Solutions

1.Series & parallel resistors

Answer: IR1 = 1.535 A

Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.

R1​ = 8 ΩR3​ = 15 Ω+−V1​24 VR2​12 ΩAR4​6 ΩB

Combine resistors from the far end

Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.

R3 + R4 = 15 + 6 = 21 Ω
R2 ∥ 21 = 12·21/(12+21) = 7.636 Ω
Req = R1 + 7.636 = 8 + 7.636 = 15.64 Ω

Current from the source

The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.

IR1 = V1/Req = 24/15.64 = 1.535 A

Answer

IR1 = 1.535 A
2.Series & parallel resistors

Answer: Req = 15.46 Ω

Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.

R1​ = 12 ΩR3​ = 8 ΩR5​ = 15 Ω+−V1​12 VR2​5 ΩAR4​4 ΩBR6​2 Ω

Combine resistors from the far end

Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.

R5 + R6 = 15 + 2 = 17 Ω
R4 ∥ 17 = 3.238 Ω
R3 + 3.238 = 11.24 Ω
R2 ∥ 11.24 = 3.46 Ω
Req = R1 + 3.46 = 12 + 3.46 = 15.46 Ω

Answer

Req = 15.46 Ω
3.Nodal analysis

Answer: IR1 = 0.3361 A

Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.

R1​ = 4 ΩR3​ = 5 Ω+−V1​10 VR2​5 ΩAR4​6 ΩBIs​4 A

Set up the nodes

Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 10 V). Unknowns: VA, VB.

KCL at node A

Currents leaving A through the resistors equal the current pushed into A by sources.

VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/5 + (VA − 10)/4 + (VA − VB)/5 = 0
0.65·VA − 0.2·VB = 2.5

KCL at node B

Currents leaving B through the resistors equal the current pushed into B by sources.

VB/R4 + (VB − VA)/R3 = Is
VB/6 + (VB − VA)/5 = 4
−0.2·VA + 0.3667·VB = 4

Solve

Δ = (0.65)(0.3667) − (−0.2)(−0.2) = 0.1983
VA = Δ1/Δ = 1.717/0.1983 = 8.655 V
VB = Δ2/Δ = 3.1/0.1983 = 15.63 V

Answer

IR1 = (V1 − VA)/R1 = (10 − 8.655)/4 = 0.3361 A
4.Nodal analysis

Answer: IR1 = 3.253 A

Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.

R1​ = 15 ΩR2​ = 6 ΩR4​ = 30 Ω+−V1​36 VR3​15 ΩAR5​30 ΩBIs​6 A−+V2​18 V

Set up the nodes

Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 36 V, V2 = −18 V). Unknowns: VA, VB.

KCL at node A

Currents leaving A through the resistors equal the current pushed into A by sources.

VA/R3 + (VA − V1)/R1 + (VA − VB)/R2 = 0
VA/15 + (VA − 36)/15 + (VA − VB)/6 = 0
0.3·VA − 0.1667·VB = 2.4

KCL at node B

Currents leaving B through the resistors equal the current pushed into B by sources.

VB/R5 + (VB − VA)/R2 + (VB − V2)/R4 = Is
VB/30 + (VB − VA)/6 + (VB − (−18))/30 = (−6)
−0.1667·VA + 0.2333·VB = −6.6

Solve

Δ = (0.3)(0.2333) − (−0.1667)(−0.1667) = 0.04222
VA = Δ1/Δ = −0.54/0.04222 = −12.79 V
VB = Δ2/Δ = −1.58/0.04222 = −37.42 V

Answer

IR1 = (V1 − VA)/R1 = (36 − −12.79)/15 = 3.253 A
5.Mesh analysis

Answer: IR3 = 1 A

Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.

R1​ = 20 ΩR2​ = 20 Ω+−V1​18 VR3​4 ΩA+−V2​10 VI1​I2​

Assign mesh currents

Draw a clockwise current in each window: I1, I2. A resistor shared by two meshes carries the difference of their currents.

KVL around mesh 1

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R1·I1 + R3(I1 − I2) = V1
20·I1 + 4(I1 − I2) = 18
24·I1 − 4·I2 = 18

KVL around mesh 2

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R2·I2 + R3(I2 − I1) = −V2
20·I2 + 4(I2 − I1) = (−10)
−4·I1 + 24·I2 = −10

Solve

Δ = (24)(24) − (−4)(−4) = 560
I1 = Δ1/Δ = 392/560 = 0.7 A
I2 = Δ2/Δ = −168/560 = −0.3 A

Answer

IR3 = I1 − I2 = 1 A

A negative mesh current flows anticlockwise.

6.Mesh analysis

Answer: VR3 = −2.1 V

Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.

R1​ = 30 ΩR2​ = 25 ΩR3​ = 10 Ω+−V1​6 VR4​2 ΩAR5​25 ΩB+−V2​5 VI1​I2​I3​

Assign mesh currents

Draw a clockwise current in each window: I1, I2, I3. A resistor shared by two meshes carries the difference of their currents.

KVL around mesh 1

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R1·I1 + R4(I1 − I2) = V1
30·I1 + 2(I1 − I2) = 6
32·I1 − 2·I2 = 6

KVL around mesh 2

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R2·I2 + R4(I2 − I1) + R5(I2 − I3) = 0
25·I2 + 2(I2 − I1) + 25(I2 − I3) = 0
−2·I1 + 52·I2 − 25·I3 = 0

KVL around mesh 3

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R3·I3 + R5(I3 − I2) = −V2
10·I3 + 25(I3 − I2) = (−5)
−25·I2 + 35·I3 = −5

Solve

Δ = det of the coefficient matrix = 38100
I1 = Δ1/Δ = 6920/38100 = 0.1816 A
I2 = Δ2/Δ = −3580/38100 = −0.09396 A
I3 = Δ3/Δ = −8000/38100 = −0.21 A

Answer

IR3 = I3 = −0.21 A
VR3 = IR3·R3 = −0.21·10 = −2.1 V

A negative mesh current flows anticlockwise.

7.Superposition

Answer: Is = 1.25 A

Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.

R1​ = 10 ΩR3​ = 10 Ω+−V1​15 VR2​20 ΩAR4​8 ΩBOPEN

Case 1 · V1 acting alone

Iₛ becomes an open circuit, so R₃ and R₄ form one series branch from A to ground, in parallel with R₂.

R3+R4 = 10+8 = 18 Ω
R2 ∥ (R3+R4) = 20·18/(20+18) = 9.474 Ω
VA = 15·9.474/(10+9.474) = 7.297 V
VB = VA·R4/(R3+R4) = 7.297·8/18 = 3.243 V
IR3′ = (VA − VB)/R3 = (7.297 − 3.243)/10 = 0.4054 A

Case 2 · Is acting alone

V₁ becomes a short, so R₁ ∥ R₂ hangs from A to ground. Iₛ splits at B between R₄ and the path R₃ + R₁∥R₂; the part through R₃ flows from B to A, against the arrow.

R1 ∥ R2 = 6.667 Ω
IR3″ = −Is·R4/(R4 + R3 + R1∥R2) = −Is·8/24.67 = −0.3243·Is

Set the total to zero

IR3′ + IR3″ = 0.4054 − 0.3243·Is = 0
Is = 0.4054/0.3243 = 1.25 A

Answer

Is = 1.25 A
8.Superposition

Answer: VR3 = −15.16 V

Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.

R1​ = 8 ΩR2​ = 20 ΩR4​ = 25 Ω+−V1​10 VR3​25 ΩAOPENBSHORT

Case 1 · V1 acting alone

V₂ becomes a short and Iₛ an open circuit. Seen from A, R₃ is in parallel with the series pair R₂+R₄.

R3 ∥ (R2+R4) = 25 ∥ 45 = 16.07 Ω
VA = 10·16.07/(8+16.07) = 6.677 V
VB = VA·R4/(R2+R4) = 6.677·25/45 = 3.709 V
VR3′ = 0 − VA = 0 − 6.677 = −6.677 V
R1​ = 8 ΩR2​ = 20 ΩR4​ = 25 ΩSHORTR3​25 ΩAIs​2.5 ABSHORT

Case 2 · Is acting alone

Both voltage sources become shorts. Iₛ splits at B between R₄ (now to ground) and R₂ in series with R₁ ∥ R₃.

R1 ∥ R3 = 6.061 Ω, so the left path is R2+6.061 = 26.06 Ω
Req = R4 ∥ 26.06 = 12.76 Ω
VB = Is·Req = 2.5·12.76 = 31.9 V
VA = VB·6.061/26.06 = 7.418 V
VR3″ = 0 − VA = 0 − 7.418 = −7.418 V
R1​ = 8 ΩR2​ = 20 ΩR4​ = 25 ΩSHORTR3​25 ΩAOPENB+−V2​9 V

Case 3 · V2 acting alone

V₁ becomes a short and Iₛ an open circuit. R₁ ∥ R₃ hangs from A, in series with R₂ back to B.

R1 ∥ R3 = 8·25/(8+25) = 6.061 Ω
VB = V2·(R2+R1∥R3)/(R4+R2+R1∥R3) = 9·26.06/51.06 = 4.593 V
VA = VB·(R1∥R3)/(R2+R1∥R3) = 4.593·6.061/26.06 = 1.068 V
VR3‴ = 0 − VA = 0 − 1.068 = −1.068 V

Add the contributions

VR3 = VR3′ + VR3″ + VR3‴
VR3 = (−6.677) + (−7.418) + (−1.068) = −15.16 V

A negative result means the real polarity is opposite to the one marked.

9.Thévenin & Norton

Answer: IL = 0.6154 A

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 3 ΩR3​ = 6 ΩSHORTR2​12 ΩAabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 3·12/(3+12) = 2.4 Ω
Rth = (R1 ∥ R2) + R3 = 2.4 + 6 = 8.4 Ω
R1​ = 3 ΩR3​ = 6 Ω+−V1​18 VR2​12 ΩAab+−Vth​

Find Vth, the open-circuit voltage

With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.

Vth = V1·R2/(R1+R2) = 18·12/(3+12) = 14.4 V
Rth​ = 8.4 Ω+−Vth​14.4 VRL​15 ΩIL​

Connect the load to the Thévenin equivalent

The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.

IL = Vth/(Rth + RL) = 14.4/(8.4 + 15) = 0.6154 A
10.Thévenin & Norton

Answer: PL = 6.974 W

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 15 ΩR3​ = 3 ΩSHORTR2​20 ΩAOPENBabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 15·20/(15+20) = 8.571 Ω
Rth = (R1 ∥ R2) + R3 = 8.571 + 3 = 11.57 Ω
R1​ = 15 ΩR3​ = 3 Ω+−V1​18 VR2​20 ΩAIs​2.5 ABab+−Vth​

Find Vth, the open-circuit voltage

With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.

VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 10.29 + (−2.5)·8.571 = −11.14 V
Vth = VB = VA + Is·R3 = −11.14 + (−2.5)·3 = −18.64 V
Rth​ = 11.57 Ω−+Vth​18.64 VRL​20 ΩIL​

Connect the load to the Thévenin equivalent

The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.

IL = Vth/(Rth + RL) = −18.64/(11.57 + 20) = −0.5905 A
PL = IL²·RL = −0.5905²·20 = 6.974 W
11.RC & RL transients

Answer: vC = 2.899 V

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Thévenin equivalent seen by the capacitor

Short the source to find Rth; open the capacitor to find the voltage it will settle at.

Rth = R1 ∥ R2 = 10·6.8/(10 + 6.8) = 4.048 kΩ
vC(∞) = 12·6.8/(10 + 6.8) = 4.857 V

Time constant

τ = Rth·C = 4.048·68 = 275.2 ms

Charging curve

vC(t) = 4.857·(1 − e−250/275.2) = 2.899 V

Answer

vC = 2.899 V
12.RC & RL transients

Answer: i = 0.225 A

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Initial value, final value, time constant

Before t = 0 both resistors are in the loop; afterwards the closed switch bypasses R₂.

i(0) = 6/(22 + 20) = 0.1429 A
i(∞) = 6/22 = 0.2727 A
τ = L/R = 22/22 = 1 ms
i(t) = 0.2727 + (0.1429 − 0.2727)·e−t/τ

Current at the given time

i(1) = 0.2727 + (−0.1299)·e−1/1 = 0.225 A

Answer

i = 0.225 A
13.AC impedance & phasors

Answer: P = 0.4555 W

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactances

XL = 314.2 Ω, XC = 67.73 Ω

Impedance

|Z| = √(50² + (246.4)²) = 251.5 Ω

Real power

Inductors and capacitors only store and return energy; the resistor absorbs all of the real power.

I = 24/251.5 = 0.09544 A
P = I²·R = 0.09544²·50 = 0.4555 W

Answer

P = 0.4555 W
14.AC impedance & phasors

Answer: |Z| = 25.69 Ω

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactance

XC = 1/(2π·200·47·10⁻⁶) = 16.93 Ω

Parallel combination

Multiply top and bottom by the complex conjugate to split Zp into real and imaginary parts.

Zp = R₂·(−jXC)/(R₂ − jXC) = (R₂·XC² − jR₂²·XC)/(R₂² + XC²)
Zp = 7.247 − j12.84 Ω

Total impedance

Z = 15 + 7.247 − j12.84 = 22.25 − j12.84 Ω
|Z| = √(22.25² + 12.84²) = 25.69 Ω

Answer

|Z| = 25.69 Ω
15.AC power & power factor

Answer: I = 44.87 A

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Line current

Only the real part of the power does work, so divide by the power factor.

I = P/(V·cos φ) = 7000/(240·0.65) = 44.87 A

Answer

I = 44.87 A
16.AC power & power factor

Answer: Pmax = 529 W

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Conjugate match

The load reactance cancels the source reactance, and the load resistance equals the source resistance.

ZL = Zs* = 25 − j10 Ω

Maximum power

I = Vs/(2Rs) = 230/50 = 4.6 A
Pmax = I²·RL = Vs²/(4Rs) = 230²/(4·25) = 529 W

Answer

Pmax = 529 W
17.Three-phase power

Answer: P = 5.192 kW

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.

Phase voltage

Vph = VL = 208 V

Phase current

|Z| = √(9² + 12²) = 15 Ω
Iph = 208/15 = 13.87 A

Total real power

Only the resistive part of each impedance absorbs real power.

P = 3·Iph²·R = 3·13.87²·9 = 5.192 kW

Answer

P = 5.192 kW

Check: cos φ = R/|Z| = 0.6, and √3·VL·IL·cos φ gives the same power.

18.Three-phase power

Answer: Cph = 322.5 µF

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.

Reactive power before and after

The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.

Q1 = 100·tan(acos 0.65) = 100·1.169 = 116.9 kvar
Q2 = 100·tan(acos 0.95) = 100·0.3287 = 32.87 kvar

Reactive power from the capacitors

QC = Q1 − Q2 = 84.04 kvar

Capacitance per phase

In a Δ bank each capacitor is connected between two lines.

V = 480 V, ω = 2π·60 = 377 rad/s
Cph = (QC/3)/(ω·V²) = 28015/(377·480²) = 322.5 µF

Answer

Cph = 322.5 µF
19.Transformers

Answer: R1′ = 1024 Ω

Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.

Referred resistance

The voltage goes up by a and the current down by a, so the ratio V/I goes up by a².

R1′ = a²·RL = 8²·16 = 1024 Ω

Answer

R1′ = 1024 Ω
20.Transformers

Answer: Sη,max = 158.1 kVA

Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.

Copper loss equals core loss

x²·1875 = 750 → x = √(750/1875) = 0.6325

Load at maximum efficiency

Sη,max = x·S = 0.6325·250 = 158.1 kVA

Answer

Sη,max = 158.1 kVA
21.Op-amp circuits

Answer: Vout = −2.8 V

Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.

Inverting input follows the input

V₋ = V₊ = −1.4 V
I = V₋/R1 = −1.4/47 = −0.02979 mA

Output voltage

The current through R₁ also flows through Rf.

Vout = V₋ + I·Rf = −1.4 + (−0.02979)·47 = −2.8 V

Answer

Vout = −2.8 V
22.Op-amp circuits

Answer: Vout = −2.321 V

Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.

Input current and ramp rate

kΩ times µF gives milliseconds.

RC = 47 kΩ · 0.22 µF = 10.34 ms
ramp rate = −Vin/(RC) = −1.2/10.34 = −0.1161 V/ms

Output at the given time

The ideal value lies inside ±Vsat, so the integrator has not clipped yet.

Vout = −Vin·t/(RC) = −1.2·20/10.34 = −2.321 V

Answer

Vout = −2.321 V
23.Diodes & transistors

Answer: IZ = 16.57 mA

Zener regulator: a reverse-biased Zener diode holds its voltage VZ while its current stays above a minimum IZ,min. The series resistor R takes the difference between input and output: IR = (Vin − VZ)/R. That current splits between the load, IL = VZ/RL, and the Zener: IZ = IR − IL. Design for the worst cases: the lowest input with the largest load must still leave IZ,min, and the highest input with no load gives the largest Zener power PZ = VZ·IZ.

Resistor current

IR = 9.4/330 = 28.48 mA

Load current

IL = 5.6/470 = 11.91 mA

Zener current

IZ = 28.48 − 11.91 = 16.57 mA

Answer

IZ = 16.57 mA
24.Diodes & transistors

Answer: IC = 17.35 mA

BJT as a switch: to switch a load fully on, the transistor is driven into saturation, where VCE = VCE(sat) and the collector current is set by the load: IC(sat) = (VCC − VCE(sat))/RC. Saturation needs at least IB = IC(sat)/β. If the base current is smaller, the transistor stays active and IC = β·IB.

Base current

IB = (5 − 0.7)/1 kΩ = 4300 µA

Saturated or active?

β·IB is larger than IC(sat), so the transistor saturates.

β·IB = 215 mA
IC(sat) = (12 − 0.2)/680 = 17.35 mA

Collector current

IC = IC(sat) = 17.35 mA

Answer

IC = 17.35 mA

The transistor is saturated.

25.Number systems

Answer: N = −120

Positional number systems: each digit is worth its value times a power of the base. In binary the places are worth 1, 2, 4, 8, 16, …; in hexadecimal 1, 16, 256, …, with A–F standing for 10–15. In 8-bit two's complement the leftmost bit is worth −128 instead of +128, which is how negative numbers are stored.

Add the place values

The other bits keep their normal positive values.

−128 + 8 = −120

Answer

N = −120
26.Number systems

Answer: R = 181

Setting bits: each bit is worth a power of two (128, 64, …, 1). One hex digit is exactly four bits, and in 8-bit two's complement the leftmost bit is worth −128. Bitwise operations work on each bit position separately.

Bit by bit

XOR gives 1 where the two bits differ.

1100 1111
XOR 0111 1010
= 1011 0101

Value of the result

1011 0101₂ = 181

Answer

R = 181
27.Digital logic: gates, K-maps & flip-flops

Answer: N = 3

Karnaugh maps: the cells are ordered in Gray code (00, 01, 11, 10), so neighbouring cells, including the ones across the edges, differ in exactly one variable. Group the 1s in rectangles of 1, 2, 4, 8 or 16 cells, as large as possible and as few as possible, until every 1 is covered. Each group is one product term: the variables that stay constant inside it. A group of 2ᵏ cells loses k variables. Don't-cares (X) may be used to make groups bigger but never have to be covered. Grouping the 0s instead gives the minimal POS form.

ABCD000111100001111000011302040517160120130151140809011110

Group the 1s

Every group is a rectangle of 2ᵏ cells; edge cells are neighbours of the cells on the opposite edge.

BCD′
A′CD
ACD′

Minimal SOP form

F = BCD′ + A′CD + ACD′
N = 3

Answer

N = 3

Another grouping of the same size exists; it has the same number of terms and literals.

28.Digital logic: gates, K-maps & flip-flops

Answer: L = 12

Karnaugh maps: the cells are ordered in Gray code (00, 01, 11, 10), so neighbouring cells, including the ones across the edges, differ in exactly one variable. Group the 1s in rectangles of 1, 2, 4, 8 or 16 cells, as large as possible and as few as possible, until every 1 is covered. Each group is one product term: the variables that stay constant inside it. A group of 2ᵏ cells loses k variables. Don't-cares (X) may be used to make groups bigger but never have to be covered. Grouping the 0s instead gives the minimal POS form.

Prime implicants

The largest groups that can be formed from 1s and Xs.

C′D, AB′D, AB′C, ABC′, A′BCD′
ABCD00011110000111100011030204X507161121130150140819X11110

Minimal cover

F = C′D + AB′C + ABC′ + A′BCD′
L = 12

Answer

L = 12
29.Laplace transforms

Answer: f(0.5) = 0.7358

Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).

Factor the denominator

s² + 4s + 4 = (s + 2)²

Partial fractions

4s + 4 = 4(s + 2) + −4
F(s) = 4/(s + 2) − 4/(s + 2)²

Inverse transform

f(t) = 4·e−2t − 4·t·e−2t
f(0.5) = (4 − 4·0.5)·e−2·0.5 = 0.7358

Answer

f(0.5) = 0.7358
30.Laplace transforms

Answer: y(1.2) = 4.514

Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).

Transform the equation

s²Y − 10s − 15 + 7(sY − 10) + 6Y = 0
Y(s) = (10s + 85)/((s + 1)(s + 6))

Partial fractions

A = 75/5 = 15
B = 25/(−5) = −5

Result

y(t) = 15·e−t − 5·e−6t
y(1.2) = 4.514

Answer

y(1.2) = 4.514

Check: y(0) = A + B = 10.

31.Block diagrams

Answer: T(0) = 0.6316

Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).

Inner loop

Gᵢ = G/(1 + G·H₁) = 4/(s + 6 + 4·2) = 4/(s + 14)

Outer loop

T(s) = K·Gᵢ/(1 + K·Gᵢ) = 24/(s + 14 + 24) = 24/(s + 38)

Result

T(0) = 24/38 = 0.6316

Answer

T(0) = 0.6316
32.Block diagrams

Answer: Kmax = 520

Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).

Characteristic equation

s³ + 13s² + 40s + K = 0

Routh array

s³ | 1 40
s² | 13 K
s¹ | (13·40 − K)/13
s⁰ | K

Stability limit

All entries of the first column must be positive.

Kmax = 13·40 = 520

Answer

Kmax = 520
33.Step response

Answer: %OS = 51.94 %

Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).

Compare with the standard form

The denominator must match s² + 2ζωₙs + ωₙ².

ωₙ² = 24 → ωₙ = 4.899 rad/s
2ζωₙ = 2 → ζ = 2/(2·4.899) = 0.2041

Result

%OS = 100·e−ζπ/√(1−ζ²) = 100·e−0.6551 = 51.94 %

Answer

%OS = 51.94 %
34.Step response

Answer: %OS = 25.53 %

Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).

Natural frequency and damping ratio

ωₙ = 1/√(LC) = 1/√(0.02·4.7 × 10⁻⁶) = 3262 rad/s
ζ = (R/2)·√(C/L) = (52/2)·√(4.7 × 10⁻⁶/0.02) = 0.3986

Result

%OS = 100·e−ζπ/√(1−ζ²) = 25.53 %

Answer

%OS = 25.53 %
35.Bode plots & margins

Answer: ∠G(jω) = −112 °

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Add the angles

∠G = atan(20/16) − 90° − atan(20/6) = 51.34° − 90° − 73.3°

Result

∠G(j20) = −112°

Answer

∠G(jω) = −112°
36.Bode plots & margins

Answer: GM = 6.021 dB

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Phase crossover

(ω/3)·(ω/5) = 1 → ω180 = √(3·5) = 3.873 rad/s

Magnitude at phase crossover

|L(jω180)| = K/(ω·√(ω² + 9)·√(ω² + 25)) = K/(3·5·(3 + 5)) = K/120

Gain margin

GM = 20·log₁₀(120/60) = 6.021 dB

Answer

GM = 6.021 dB
37.Stability: Routh–Hurwitz & root locus

Answer: N = 1

Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.

Characteristic polynomial

s³ + 7s² + 6s − 10 = 0

Routh array

s³: 1, 6
s²: 7, −10
s¹: 7.429
s⁰: −10

Sign changes in the first column

1 → 7 → 7.429 → −10
N = 1

Answer

N = 1

Positive feedback makes the constant coefficient negative: one real pole always moves into the right half-plane.

38.Stability: Routh–Hurwitz & root locus

Answer: K = 1.125

Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.

Magnitude condition

K = |s|·|s + 2|·|s + 3|

Evaluate at the point

K = 1.5·0.5·1.5 = 1.125

Answer

K = 1.125

Check: s(s + 2)(s + 3) + K is zero at s = −1.5.

39.Steady-state error & PID control

Answer: ess = 9.091 %

Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.

Position constant

Kp = 20·0.5 = 10

Step error

ess = 100/(1 + 10) = 9.091 %

Answer

ess = 9.091 %
40.Steady-state error & PID control

Answer: ess = 1

P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).

Velocity constant

s·C(s) = 5s + 0.5 → 0.5 as s → 0.

Kv = 0.5·10/5 = 1

Ramp error

ess = 1/1 = 1

Answer

ess = 1

The PI controller removes the step error completely; a ramp is followed with a constant lag.