In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Series & parallel resistors
Resistors in series
Req = R1 + R2 + …
Resistors in parallel
1/Req = 1/R1 + 1/R2 + …
Two in parallel
Req = R1R2 / (R1 + R2)
Ohm's law
V = I·R
Power
P = V·I = I²R = V²/R
Method
Start at the end of the network furthest from the terminals.
Combine resistors in series by adding them, and resistors in parallel with 1/R = 1/R₁ + 1/R₂ + …
Redraw the circuit after each step.
Repeat until one resistor is left between the terminals.
Nodal analysis
Kirchhoff’s current law
ΣIin = ΣIout
Branch current
I = (Va − Vb)/R
Reference node
Vground = 0
Method
Choose a reference node (ground) and label the other node voltages.
Write Kirchhoff’s current law at every unknown node: currents leaving through each branch equal the currents entering.
Express every branch current as (Va − Vb)/R.
Solve the system of equations, then find any current you need.
Mesh analysis
Kirchhoff’s voltage law
ΣV = 0 around every loop
Shared resistor
current = I1 − I2
Current source in a mesh
fixes that mesh current
Method
Draw a clockwise current in every mesh (window) of the circuit.
Apply Kirchhoff’s voltage law around each mesh: the sum of voltage drops is zero.
In a resistor shared by two meshes the current is the difference of the two mesh currents.
Solve the equations; a negative result means the current flows the other way.
Superposition
Superposition
x = x1 + x2 + … (one source at a time)
Switched-off voltage source
short circuit (0 V)
Switched-off current source
open circuit (0 A)
Voltage divider
V2 = V·R2/(R1 + R2)
Current divider
I1 = I·R2/(R1 + R2)
Method
Count the independent sources. You will solve one simpler circuit per source.
Keep one source and switch off the others: a voltage source becomes a short circuit (a wire), a current source becomes an open circuit (a gap).
Solve the simpler circuit for the voltage or current you need, keeping track of its direction.
Repeat for every source, then add the contributions with their signs.
Thévenin & Norton
Thévenin voltage
Vth = Vopen circuit
Thévenin resistance
Rth: all sources off, seen from a–b
Norton current
IN = Vth/Rth
Load current
IL = Vth/(Rth + RL)
Maximum power transfer
RL = Rth, Pmax = Vth²/(4Rth)
Method
Remove the load and mark the two terminals a and b.
Find the open-circuit voltage between a and b: this is Vth.
Switch off all independent sources and find the resistance seen from a–b: this is Rth.
Put the load back on the equivalent circuit: Vth in series with Rth.
For the Norton equivalent, convert: IN = Vth/Rth, with RN = Rth in parallel.
RC & RL transients
Time constant
τ = RC | τ = L/R
Response
x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ
Capacitor at DC
open circuit; vC cannot jump
Inductor at DC
short circuit; iL cannot jump
Settled
t ≈ 5τ
Method
Find the initial value just after switching: a capacitor voltage and an inductor current cannot jump.
Find the final value long after switching: a capacitor acts as an open circuit, an inductor as a short circuit.
Find the time constant: τ = RC or τ = L/R, using the resistance seen by the capacitor or inductor.
Use x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ.
AC impedance & phasors
Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z
Method
Convert the frequency: ω = 2πf.
Find each reactance: XL = ωL and XC = 1/(ωC).
Add impedances like resistors, with Z = R + jX.
Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.
AC power & power factor
Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)
Three-phase power
Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η
Transformers
Turns ratio
a = N1/N2 = V1/V2
Current ratio
I1/I2 = N2/N1 = 1/a
Rated current
I = S/V
Referred impedance
Z1′ = a²·ZL
Copper loss at part load
Pcu = x²·Pcu,fl
Efficiency
η = x·S·pf/(x·S·pf + Pcore + x²·Pcu,fl)
Maximum efficiency
x = √(Pcore/Pcu,fl)
Op-amp circuits
Inverting amplifier
Vout = −(Rf/Rin)·Vin
Non-inverting amplifier
Vout = (1 + Rf/R1)·Vin
Summing amplifier
Vout = −Rf(V1/R1 + V2/R2)
Ideal op-amp
V+ = V−, Iin = 0
Diodes & transistors
Diode (constant drop)
VD = 0.7 V when conducting
Active region
VBE = 0.7 V, IC = β·IB, IE = (β + 1)·IB
Fixed bias
IB = (VCC − 0.7)/RB
Divider bias
IB = (VTH − 0.7)/(RTH + (β + 1)RE)
Thévenin of the divider
VTH = VCC·R2/(R1 + R2), RTH = R1∥R2
Collector loop
VCE = VCC − ICRC − IERE
Saturation
IC(sat) = (VCC − VCE(sat))/RC, IB ≥ IC(sat)/β
Number systems
Place values
binary 2k, octal 8k, hex 16k
To decimal
Σ dk·bk
From decimal
divide by the base, read the remainders bottom-up
Hex ↔ binary
one hex digit = 4 bits
Two’s complement
invert the bits and add 1
Digital logic: gates, K-maps & flip-flops
Basic gates
A·B, A + B, A′, (A·B)′, (A + B)′, A ⊕ B
Boolean rules
X + X′ = 1, X·X′ = 0, X + XY = X, XY + XY′ = X
De Morgan
(X·Y)′ = X′ + Y′, (X + Y)′ = X′·Y′
Karnaugh map order
00, 01, 11, 10 (Gray code)
Group of 2ᵏ cells
loses k variables
4-to-1 multiplexer
F = A′B′I0 + A′BI1 + AB′I2 + ABI3
Flip-flops
D: Q⁺ = D, T: Q⁺ = T ⊕ Q, JK: Q⁺ = JQ′ + K′Q
Counters
n-bit: 2ⁿ states; mod-N: smallest n with 2ⁿ ≥ N; fout = fclk/N
Ripple counter
fmax = 1/(n·tpd)
Ring and Johnson counters
n and 2n states
Method
For a circuit, work from the inputs to the output one gate at a time and write the value on every wire, or write its expression and fill in the truth table.
For simplification, put the 1s (and the don’t-cares as X) into a Karnaugh map with Gray-code rows and columns: 00, 01, 11, 10.
Cover the 1s with as few and as large groups of 1, 2, 4, 8 or 16 cells as possible, wrapping round the edges; each group is one product term made of the variables that stay constant. Group the 0s for the POS form.
For flip-flops and counters, read the inputs at each active clock edge, write the state after every edge, and remember that an n-bit counter wraps round after 2ⁿ states.
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Series & parallel resistorsMedium
Find the equivalent resistance Req seen by the source V1.
V1 = 18 VR1 = 6 ΩR2 = 15 ΩR3 = 6 ΩR4 = 20 Ω
Req = Ω
2.Series & parallel resistorsHard
Find the current IR1 delivered by the source, which flows through R1.
A load RL = 2 Ω is connected across a–b. Replace the rest of the circuit with its Thévenin equivalent and find the load current IL.
V1 = 9 VR1 = 15 ΩR2 = 3 ΩR3 = 6 ΩRL = 2 Ω
IL = A
10.Thévenin & NortonHard
Find the Norton current IN: the current that flows from a to b if the terminals are shorted.
V1 = 15 VIs = 6 AR1 = 12 ΩR2 = 25 ΩR3 = 2 Ω
IN = A
11.RC & RL transientsMedium
The inductor carries no current before the switch closes at t = 0. Find the voltage vL across the inductor at t = 5 ms.
Vs = 9 VR = 20 ΩL = 47 mHt = 5 ms
vL = V
12.RC & RL transientsHard
Just before the switch closes at t = 0, the capacitor holds 5 V with the polarity shown. How long does it take for vC to reach 7.1 V? Find t.
Vs = 12 VR = 4.7 kΩC = 10 µFvC(0) = 5 V
t = ms
13.AC impedance & phasorsMedium
A series RLC circuit is connected to a 50 V (rms), 100 Hz supply. Find the real power P taken from the supply.
V = 50 V (rms)f = 100 HzR = 100 ΩL = 200 mHC = 47 µF
P = W
14.AC impedance & phasorsHard
A resistor R1 is connected in series with a parallel combination of R2 and a capacitor C, across a 50 V (rms), 50 Hz supply. Find the rms current I.
V = 50 V (rms)f = 50 HzR1 = 15 ΩR2 = 50 ΩC = 100 µF
I = A
15.AC power & power factorMedium
Two loads are connected in parallel to a 400 V single-phase supply: a 28 kW load at a power factor of 0.75 lagging and a 24 kW heater (unity power factor). Find the overall power factor cos φ seen by the supply.
A single-phase load takes 5 kW at a power factor of 0.6 lagging from a 400 V, 60 Hz supply. A capacitor connected in parallel raises the power factor to 0.95. Find the reactive power QC the capacitor must supply.
P = 5 kWpf1 = 0.6pf2 = 0.95V = 400 Vf = 60 Hz
QC = kvar
17.Three-phase powerMedium
A balanced Δ-connected load with an impedance of 8 + j6 Ω per phase is connected to a balanced three-phase supply with a line-to-line voltage of 400 V. Find the total real power P absorbed by the load in kW.
VL = 400 VZ = 8 + j6 Ω per phase
P = kW
18.Three-phase powerHard
A balanced three-phase load takes 120 kW at a power factor of 0.8 lagging from a 400 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.9 lagging. The real power stays the same. Find the total reactive power QC the capacitor bank must supply, in kvar.
P = 120 kWpf1 = 0.8pf2 = 0.9VL = 400 Vf = 50 Hz
QC = kvar
19.TransformersMedium
A single-phase 50 kVA, 4160/480 V transformer operates at its rated load. Treat it as ideal. Find the current IHV in the high-voltage winding.
S = 50 kVAV1 = 4160 VV2 = 480 V
IHV = A
20.TransformersHard
A single-phase 50 kVA transformer has a core loss of 150 W. At rated load and a power factor of 0.8 lagging its efficiency is 97.5%. Find the full-load copper loss Pcu,fl in watts.
S = 50 kVAPcore = 150 Wpf = 0.8η = 97.5%
Pcu,fl = W
21.Op-amp circuitsMedium
The op-amp is ideal and runs from ±15 V supplies. Find the output voltage Vout.
Vin = −0.2 VR1 = 100 kΩRf = 100 kΩ
Vout = V
22.Op-amp circuitsHard
The op-amp is ideal and runs from ±15 V supplies. The resistor ratios are not matched. Find the output voltage Vout.
An NPN transistor with β = 80 has voltage-divider bias from VCC = 15 V: R₁ = 68 kΩ from VCC to the base and R₂ = 10 kΩ from the base to ground. The collector resistor is RC = 2.2 kΩ and the emitter resistor is RE = 1.2 kΩ. Take VBE = 0.7 V and use the Thévenin equivalent of the divider (do not neglect the base current). Find the collector–emitter voltage VCE.
An NPN transistor with β = 80 switches a 220 Ω load resistor connected between VCC = 9 V and its collector. The emitter is grounded. The base is driven from a 3.3 V logic output through a base resistor RB. Take VBE = 0.7 V and VCE(sat) = 0.2 V. For reliable switching, design for a base current 2 times the minimum needed for saturation. Find RB in kΩ.
F(s) = (5s + 15)/(s² + 10s + 24). Its inverse transform has the form f(t) = A·e−4t + B·e−6t. Find the coefficient A by partial fractions.
F(s) = (5s + 15)/(s² + 10s + 24)
A =
30.Laplace transformsHard
A system is described by the differential equation y″ + 6y′ + 8y = u′ + 14u, with input u(t) and output y(t). Find its transfer function G(s) = Y(s)/U(s) (zero initial conditions) and evaluate the impulse response g(t) at t = 0.75 s. Find g(0.75).
y″ + 6y′ + 8y = u′ + 14ut = 0.75 s
g(0.75) =
31.Block diagramsMedium
The plant G(s) = 8/(s + 6) has an inner (minor) negative feedback loop with gain H₁ = 1. A controller gain K = 3 and an outer unity negative feedback loop close the system. Find the closed-loop DC gain T(0).
G(s) = 8/(s + 6)H₁ = 1K = 3
T(0) =
32.Block diagramsHard
A proportional controller K drives the plant G(s) = 7/(s + 2) in a unity negative feedback loop. A disturbance step of size 2 enters at the plant input while R = 0. Find the smallest gain K that keeps the steady-state output at or below 0.07.
G(s) = 7/(s + 2)D = 2css ≤ 0.07
K =
33.Step responseMedium
A system has the transfer function G(s) = 120/(s² + 10s + 60) and receives a unit step input. Find the peak time tp of the step response.
G(s) = 120/(s² + 10s + 60)
tp = s
34.Step responseHard
A unity negative feedback loop has G(s) = 40/(s(s + 2)). Find the 2 % settling time ts of the closed-loop step response, using ts ≈ 4/(ζωₙ).
G(s) = 40/(s(s + 2))
ts = s
35.Bode plots & marginsMedium
In the series RLC band-pass filter shown the output is taken across R = 20 Ω, with L = 10 mH and C = 2.2 µF. Find the centre (resonant) frequency f0 in Hz.
R = 20 ΩL = 10 mHC = 2.2 µF
f0 = Hz
36.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 2/(s(s + 2)). Find the gain crossover frequency ωc, where |L(jω)| = 1.
L(s) = 2/(s(s + 2))
ωc = rad/s
37.Stability: Routh–Hurwitz & root locusMedium
The loop in the diagram uses positive feedback, with L(s) = 20/(s(s + 3)(s + 4)). How many closed-loop poles N lie in the right half-plane?
L(s) = 20/(s(s + 3)(s + 4))
N =
38.Stability: Routh–Hurwitz & root locusHard
The root locus of L(s) = K/(s(s + 1)(s + 3)) leaves the real axis between s = 0 and s = −1. Find the break-away point sb.
L(s) = K/(s(s + 1)(s + 3))
sb =
39.Steady-state error & PID controlMedium
A process G(s) = 1/(1s + 1) is controlled by a proportional gain K = 4 in a unity-feedback loop. Find the steady-state error ess for a step, as a percentage of the step size.
G(s) = 1/(1s + 1)K = 4
ess = %
40.Steady-state error & PID controlHard
A PI controller C(s) = Kp + Ki/s drives the plant G(s) = 5/(s + 1) in a unity-feedback loop. The closed loop must have ωₙ = 2 rad/s and ζ = 0.8. Find the integral gain Ki.
G(s) = 5/(s + 1)ωₙ = 2 rad/sζ = 0.8
Ki =
3Solutions
1.Series & parallel resistors
Answer: Req = 15.51 Ω
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 6 + 20 = 26 Ω
R2 ∥ 26 = 15·26/(15+26) = 9.512 Ω
Req = R1 + 9.512 = 6 + 9.512 = 15.51 Ω
Answer
Req = 15.51 Ω
2.Series & parallel resistors
Answer: IR1 = 2.89 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 8 + 6 = 14 Ω
R4 ∥ 14 = 3.684 Ω
R3 + 3.684 = 9.684 Ω
R2 ∥ 9.684 = 4.381 Ω
Req = R1 + 4.381 = 6 + 4.381 = 10.38 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 30/10.38 = 2.89 A
Answer
IR1 = 2.89 A
3.Nodal analysis
Answer: IR1 = −0.5472 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 6 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/8 + (VA − 6)/2 + (VA − VB)/4 = 0
0.875·VA − 0.25·VB = 3
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R4 + (VB − VA)/R3 = Is
VB/5 + (VB − VA)/4 = 4
−0.25·VA + 0.45·VB = 4
Solve
Δ = (0.875)(0.45) − (−0.25)(−0.25) = 0.3312
VA = Δ1/Δ = 2.35/0.3312 = 7.094 V
VB = Δ2/Δ = 4.25/0.3312 = 12.83 V
Answer
IR1 = (V1 − VA)/R1 = (6 − 7.094)/2 = −0.5472 A
4.Nodal analysis
Answer: IR1 = 1.088 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 24 V, V2 = 6 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R3 + (VA − V1)/R1 + (VA − VB)/R2 = 0
VA/10 + (VA − 24)/12 + (VA − VB)/6 = 0
0.35·VA − 0.1667·VB = 2
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R5 + (VB − VA)/R2 + (VB − V2)/R4 = Is
VB/2 + (VB − VA)/6 + (VB − 6)/10 = 6
−0.1667·VA + 0.7667·VB = 6.6
Solve
Δ = (0.35)(0.7667) − (−0.1667)(−0.1667) = 0.2406
VA = Δ1/Δ = 2.633/0.2406 = 10.95 V
VB = Δ2/Δ = 2.643/0.2406 = 10.99 V
Answer
IR1 = (V1 − VA)/R1 = (24 − 10.95)/12 = 1.088 A
5.Mesh analysis
Answer: IR2 = −3.333 A
Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.
Assign mesh currents
Draw a clockwise current in each window: I1, I2. A resistor shared by two meshes carries the difference of their currents.
KVL around mesh 1
Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).
R1·I1 + R3(I1 − I2) = V1
3·I1 + 3(I1 − I2) = 18
6·I1 − 3·I2 = 18
KVL around mesh 2
Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).
R2·I2 + R3(I2 − I1) = −V2
3·I2 + 3(I2 − I1) = (−24)
−3·I1 + 6·I2 = −24
Solve
Δ = (6)(6) − (−3)(−3) = 27
I1 = Δ1/Δ = 36/27 = 1.333 A
I2 = Δ2/Δ = −90/27 = −3.333 A
Answer
IR2 = I2 = −3.333 A
A negative mesh current flows anticlockwise.
6.Mesh analysis
Answer: I2 = 0.1382 A
Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.
Assign mesh currents
Draw a clockwise current in each window: I1, I2, I3. A resistor shared by two meshes carries the difference of their currents.
KVL around mesh 1
Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).
R1·I1 + R4(I1 − I2) = V1
12·I1 + 12(I1 − I2) = 18
24·I1 − 12·I2 = 18
KVL around mesh 2
Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).
R2·I2 + R4(I2 − I1) + R5(I2 − I3) = 0
30·I2 + 12(I2 − I1) + 12(I2 − I3) = 0
−12·I1 + 54·I2 − 12·I3 = 0
KVL around mesh 3
Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).
R3·I3 + R5(I3 − I2) = −V2
10·I3 + 12(I3 − I2) = (−6)
−12·I2 + 22·I3 = −6
Solve
Δ = det of the coefficient matrix = 21888
I1 = Δ1/Δ = 17928/21888 = 0.8191 A
I2 = Δ2/Δ = 3024/21888 = 0.1382 A
I3 = Δ3/Δ = −4320/21888 = −0.1974 A
Answer
I2 = 0.1382 A
A negative mesh current flows anticlockwise.
7.Superposition
Answer: Is = 1.875 A
Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.
Case 1 · V1 acting alone
Iₛ becomes an open circuit, so R₃ and R₄ form one series branch from A to ground, in parallel with R₂.
R3+R4 = 3+8 = 11 Ω
R2 ∥ (R3+R4) = 15·11/(15+11) = 6.346 Ω
VA = 18·6.346/(3+6.346) = 12.22 V
VB = VA·R4/(R3+R4) = 12.22·8/11 = 8.889 V
IR3′ = (VA − VB)/R3 = (12.22 − 8.889)/3 = 1.111 A
Case 2 · Is acting alone
V₁ becomes a short, so R₁ ∥ R₂ hangs from A to ground. Iₛ splits at B between R₄ and the path R₃ + R₁∥R₂; the part through R₃ flows from B to A, against the arrow.
Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.
Case 1 · V1 acting alone
V₂ becomes a short and Iₛ an open circuit. Seen from A, R₃ is in parallel with the series pair R₂+R₄.
A negative result means the real current flows against the arrow.
9.Thévenin & Norton
Answer: IL = 0.1429 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 15·3/(15+3) = 2.5 Ω
Rth = (R1 ∥ R2) + R3 = 2.5 + 6 = 8.5 Ω
Find Vth, the open-circuit voltage
With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.
Vth = V1·R2/(R1+R2) = 9·3/(15+3) = 1.5 V
Connect the load to the Thévenin equivalent
The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.
IL = Vth/(Rth + RL) = 1.5/(8.5 + 2) = 0.1429 A
10.Thévenin & Norton
Answer: IN = −4.997 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 12·25/(12+25) = 8.108 Ω
Rth = (R1 ∥ R2) + R3 = 8.108 + 2 = 10.11 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 10.14 + (−6)·8.108 = −38.51 V
Vth = VB = VA + Is·R3 = −38.51 + (−6)·2 = −50.51 V
Norton equivalent
A Norton source is the same circuit seen as a current source in parallel with R_th. Its current is the short-circuit current at a–b.
IN = Vth/Rth = −50.51/10.11 = −4.997 A
11.RC & RL transients
Answer: vL = 1.072 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant and final current
Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.
τ = L/R = 47 mH / 20 Ω = 2.35 ms
i(∞) = Vs/R = 9/20 = 0.45 A
Inductor voltage
At t = 0 the whole supply voltage appears across the inductor; it then decays to zero.
vL(t) = Vs·e−t/τ = 9·e−5/2.35 = 1.072 V
Answer
vL = 1.072 V
12.RC & RL transients
Answer: t = 16.76 ms
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
The capacitor voltage cannot jump, so it starts at its stored value and heads for the source voltage.
t = τ·ln((5 − 12)/(7.1 − 12)) = 47·ln(1.429) = 16.76 ms
Answer
t = 16.76 ms
13.AC impedance & phasors
Answer: P = 13.57 W
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
XL = 125.7 Ω, XC = 33.86 Ω
Impedance
|Z| = √(100² + (91.8)²) = 135.7 Ω
Real power
Inductors and capacitors only store and return energy; the resistor absorbs all of the real power.
I = 50/135.7 = 0.3683 A
P = I²·R = 0.3683²·100 = 13.57 W
Answer
P = 13.57 W
14.AC impedance & phasors
Answer: I = 1.347 A
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactance
XC = 1/(2π·50·100·10⁻⁶) = 31.83 Ω
Parallel combination
Multiply top and bottom by the complex conjugate to split Zp into real and imaginary parts.
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power of each load
A lagging load takes reactive power (Q > 0); a leading load supplies it (Q < 0).
Q1 = 28·tan(arccos 0.75) = 24.69 kvar
Q2 = 0 = 0 kvar
Totals
P = 28 + 24 = 52 kW
Q = 24.69 + 0 = 24.69 kvar
S = √(52² + 24.69²) = 57.57 kVA
Overall power factor
cos φ = P/S = 52/57.57 = 0.9033 lagging
Answer
cos φ = 0.9033
16.AC power & power factor
Answer: QC = 5.023 kvar
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = P·tan φ1 = 5·tan(53.13°) = 6.667 kvar
Q2 = P·tan φ2 = 5·tan(18.19°) = 1.643 kvar
QC = Q1 − Q2 = 5.023 kvar
Answer
QC = 5.023 kvar
17.Three-phase power
Answer: P = 38.4 kW
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Phase voltage
Vph = VL = 400 V
Phase current
|Z| = √(8² + 6²) = 10 Ω
Iph = 400/10 = 40 A
Total real power
Only the resistive part of each impedance absorbs real power.
P = 3·Iph²·R = 3·40²·8 = 38.4 kW
Answer
P = 38.4 kW
Check: cos φ = R/|Z| = 0.8, and √3·VL·IL·cos φ gives the same power.
18.Three-phase power
Answer: QC = 31.88 kvar
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 120·tan(acos 0.8) = 120·0.75 = 90 kvar
Q2 = 120·tan(acos 0.9) = 120·0.4843 = 58.12 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 31.88 kvar
Answer
QC = 31.88 kvar
19.Transformers
Answer: IHV = 12.02 A
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Rated current
Both windings carry the same apparent power.
IHV = S/V = 50000/4160 = 12.02 A
Answer
IHV = 12.02 A
20.Transformers
Answer: Pcu,fl = 875.6 W
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.
Output and input power
Pout = 50·0.8 = 40 kW
Pin = 40000/0.975 = 41026 W
Total and copper losses
Ploss = 41026 − 40000 = 1026 W
Pcu,fl = 1026 − 150 = 875.6 W
Answer
Pcu,fl = 875.6 W
21.Op-amp circuits
Answer: Vout = −0.4 V
Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.
Inverting input follows the input
V₋ = V₊ = −0.2 V
I = V₋/R1 = −0.2/100 = −0.002 mA
Output voltage
The current through R₁ also flows through Rf.
Vout = V₋ + I·Rf = −0.2 + (−0.002)·100 = −0.4 V
Answer
Vout = −0.4 V
22.Op-amp circuits
Answer: Vout = −1.684 V
Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.
Voltage at the + input
V₊ = V2·R4/(R3 + R4) = 1.1·22/(22 + 22) = 0.55 V
Superpose the two inputs
With V₂ = 0, V₁ sees an inverting amplifier. With V₁ = 0, V₊ is amplified by the non-inverting gain 1 + R₂/R₁.
BJT bias point: in the active region VBE = 0.7 V, IC = β·IB and IE = (β + 1)·IB. Find IB from the base loop with KVL, then IC, then VCE from the collector–emitter loop. A voltage divider at the base is replaced by its Thévenin equivalent VTH = VCC·R₂/(R₁ + R₂), RTH = R₁∥R₂; an emitter resistor appears (β + 1) times larger in the base loop.
Thévenin equivalent of the divider
VTH = 15·10/(68 + 10) = 1.923 V
RTH = 68·10/(68 + 10) = 8.718 kΩ
Base current
KVL around the base loop; the emitter current is (β + 1)·IB.
IB = (1.923 − 0.7)/(8.718 + 81·1.2) = 11.55 µA
Collector current
IC = 80·11.55 µA = 0.9238 mA
IE = 81·11.55 µA = 0.9353 mA
Collector–emitter voltage
VCE = 15 − 0.9238·2.2 − 0.9353·1.2 = 11.85 V
Answer
VCE = 11.85 V
24.Diodes & transistors
Answer: RB = 2.6 kΩ
BJT as a switch: to switch a load fully on, the transistor is driven into saturation, where VCE = VCE(sat) and the collector current is set by the load: IC(sat) = (VCC − VCE(sat))/RC. Saturation needs at least IB = IC(sat)/β. If the base current is smaller, the transistor stays active and IC = β·IB.
Collector current in saturation
IC(sat) = (9 − 0.2)/220 = 40 mA
Minimum base current
IB(min) = IC(sat)/β = 40/80 = 500 µA
Design base current
IB = 2·500 µA = 1000 µA
Base resistor
RB = (3.3 − 0.7)/IB = 2.6 V/1 mA = 2.6 kΩ
Answer
RB = 2.6 kΩ
25.Number systems
Answer: U = 252
Setting bits: each bit is worth a power of two (128, 64, …, 1). One hex digit is exactly four bits, and in 8-bit two's complement the leftmost bit is worth −128. Bitwise operations work on each bit position separately.
Invert and add one
4 = 0000 0100
inverted: 1111 1011
+1 → 1111 1100
Read it as unsigned
1111 1100₂ = 256 − 4 = 252
Answer
U = 252
26.Number systems
Answer: N = 4.295 × 10⁹
Positional number systems: each digit is worth its value times a power of the base. In binary the places are worth 1, 2, 4, 8, 16, …; in hexadecimal 1, 16, 256, …, with A–F standing for 10–15. In 8-bit two's complement the leftmost bit is worth −128 instead of +128, which is how negative numbers are stored.
Largest value
232 − 1 = 4294967295
Answer
N = 4294967295
27.Digital logic: gates, K-maps & flip-flops
Answer: L = 7
Boolean algebra: the rules that simplify expressions are X + X′ = 1 and X·X′ = 0, X + X = X, absorption X + X·Y = X, the combining rule X·Y + X·Y′ = X, X + X′Y = X + Y and the consensus theorem XY + X′Z + YZ = XY + X′Z. De Morgan's laws turn (X·Y)′ into X′ + Y′ and (X + Y)′ into X′·Y′. A Karnaugh map applies these rules graphically: every group of two neighbouring cells is one use of XY + XY′ = X.
Minterms of the expression
A′B′C′ → m(0)
AB → m(6, 7)
A′BC → m(3)
Group and read off
F = BC + AB + A′B′C′
Count the literals
L = 7
Answer
L = 7
28.Digital logic: gates, K-maps & flip-flops
Answer: N = 3
Karnaugh maps: the cells are ordered in Gray code (00, 01, 11, 10), so neighbouring cells, including the ones across the edges, differ in exactly one variable. Group the 1s in rectangles of 1, 2, 4, 8 or 16 cells, as large as possible and as few as possible, until every 1 is covered. Each group is one product term: the variables that stay constant inside it. A group of 2ᵏ cells loses k variables. Don't-cares (X) may be used to make groups bigger but never have to be covered. Grouping the 0s instead gives the minimal POS form.
Prime implicants
The largest groups that can be formed from 1s and Xs.
BC, AD, AC, AB
Essential prime implicants
BC, AD, AB
N = 3
Answer
N = 3
29.Laplace transforms
Answer: A = −2.5
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Factor the denominator
s² + 10s + 24 = (s + 4)(s + 6)
F(s) = A/(s + 4) + B/(s + 6)
Cover-up rule
Multiply by (s + 4) and set s = −4: the B-term vanishes.
A = (5s + 15)/(s + 6) |s = −4 = −5/2 = −2.5
Answer
A = −2.5
(B = 7.5, so f(t) = −2.5·e−4t + 7.5·e−6t)
30.Laplace transforms
Answer: g(0.75) = 1.09
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transfer function
G(s) = Y(s)/U(s) = (s + 14)/(s² + 6s + 8)
Partial fractions
s² + 6s + 8 = (s + 2)(s + 4)
A = 6, B = −5
Impulse response
g(t) = 6·e−2t − 5·e−4t
g(0.75) = 1.09
Answer
g(0.75) = 1.09
31.Block diagrams
Answer: T(0) = 0.6316
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Disturbance response
css = D·G(0)/(1 + K·G(0)) = 2·7/(2 + 7K)
Solve for K
2 + 7K = 2·7/0.07 = 200
K = (200 − 2)/7 = 28.29
Answer
K = 28.29
33.Step response
Answer: tp = 0.531 s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
For this loop ζωₙ = a/2 whatever K is: raising K adds overshoot but does not shorten the settling time.
35.Bode plots & margins
Answer: f0 = 1073 Hz
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Resonant frequency
ω₀ = 1/√(LC) = 1/√(0.01·2.2 × 10⁻⁶) = 6742 rad/s
f₀ = ω₀/(2π) = 1073 Hz
Answer
f0 = 1073 Hz
36.Bode plots & margins
Answer: ωc = 0.9102 rad/s
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Gain crossover
ω⁴ + 4ω² − 4 = 0
ω² = (−4 + √(16 + 4·4))/2 = 0.8284
ωc = 0.9102 rad/s
Answer
ωc = 0.9102 rad/s
37.Stability: Routh–Hurwitz & root locus
Answer: N = 1
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
Characteristic polynomial
s³ + 7s² + 12s − 20 = 0
Routh array
s³: 1, 12
s²: 7, −20
s¹: 14.86
s⁰: −20
Sign changes in the first column
1 → 7 → 14.86 → −20
N = 1
Answer
N = 1
Positive feedback makes the constant coefficient negative: one real pole always moves into the right half-plane.
38.Stability: Routh–Hurwitz & root locus
Answer: sb = −0.4514
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Gain along the real axis
K(s) = −s(s + 1)(s + 3) = −(s³ + 4s² + 3s)
Stationary points
dK/ds = −(3s² + 8s + 3) = 0
s = (−8 ± √(64 − 36))/6 = −0.4514, −2.215
Pick the point on the locus
The locus lies on the real axis between 0 and −1; the other root is not on the locus.
sb = −0.4514
Answer
sb = −0.4514
39.Steady-state error & PID control
Answer: ess = 20 %
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Position constant
Kp = 4·1 = 4
Step error
ess = 100/(1 + 4) = 20 %
Answer
ess = 20 %
40.Steady-state error & PID control
Answer: Ki = 0.8
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
1 + C(s)G(s) = 0, multiplied by s(s + 1).
s² + (1 + 5Kp)s + 5Ki
Target polynomial
s² + 2·0.8·2s + 2² = s² + 3.2s + 4
Match the coefficients
5Ki = 4 → Ki = 0.8
Answer
Ki = 0.8
The integral term makes the loop type 1, so a step is followed without steady-state error.
This is independent practice material. ExamProblems is not affiliated with or endorsed by the organisation that runs this exam, and the exam name is used only to describe the content. The FE exam is run by NCEES, which is not affiliated with ExamProblems and does not endorse it.