FE Electrical and Computer exam practice: cram pack

Formula sheets, the key method steps for every topic and 40 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

Series & parallel resistors

Resistors in series
Req = R1 + R2 + …
Resistors in parallel
1/Req = 1/R1 + 1/R2 + …
Two in parallel
Req = R1R2 / (R1 + R2)
Ohm's law
V = I·R
Power
P = V·I = I²R = V²/R

Method

  1. Start at the end of the network furthest from the terminals.
  2. Combine resistors in series by adding them, and resistors in parallel with 1/R = 1/R₁ + 1/R₂ + …
  3. Redraw the circuit after each step.
  4. Repeat until one resistor is left between the terminals.

Nodal analysis

Kirchhoff’s current law
ΣIin = ΣIout
Branch current
I = (Va − Vb)/R
Reference node
Vground = 0

Method

  1. Choose a reference node (ground) and label the other node voltages.
  2. Write Kirchhoff’s current law at every unknown node: currents leaving through each branch equal the currents entering.
  3. Express every branch current as (Va − Vb)/R.
  4. Solve the system of equations, then find any current you need.

Mesh analysis

Kirchhoff’s voltage law
ΣV = 0 around every loop
Shared resistor
current = I1 − I2
Current source in a mesh
fixes that mesh current

Method

  1. Draw a clockwise current in every mesh (window) of the circuit.
  2. Apply Kirchhoff’s voltage law around each mesh: the sum of voltage drops is zero.
  3. In a resistor shared by two meshes the current is the difference of the two mesh currents.
  4. Solve the equations; a negative result means the current flows the other way.

Superposition

Superposition
x = x1 + x2 + … (one source at a time)
Switched-off voltage source
short circuit (0 V)
Switched-off current source
open circuit (0 A)
Voltage divider
V2 = V·R2/(R1 + R2)
Current divider
I1 = I·R2/(R1 + R2)

Method

  1. Count the independent sources. You will solve one simpler circuit per source.
  2. Keep one source and switch off the others: a voltage source becomes a short circuit (a wire), a current source becomes an open circuit (a gap).
  3. Solve the simpler circuit for the voltage or current you need, keeping track of its direction.
  4. Repeat for every source, then add the contributions with their signs.

Thévenin & Norton

Thévenin voltage
Vth = Vopen circuit
Thévenin resistance
Rth: all sources off, seen from a–b
Norton current
IN = Vth/Rth
Load current
IL = Vth/(Rth + RL)
Maximum power transfer
RL = Rth, Pmax = Vth²/(4Rth)

Method

  1. Remove the load and mark the two terminals a and b.
  2. Find the open-circuit voltage between a and b: this is Vth.
  3. Switch off all independent sources and find the resistance seen from a–b: this is Rth.
  4. Put the load back on the equivalent circuit: Vth in series with Rth.
  5. For the Norton equivalent, convert: IN = Vth/Rth, with RN = Rth in parallel.

RC & RL transients

Time constant
τ = RC | τ = L/R
Response
x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ
Capacitor at DC
open circuit; vC cannot jump
Inductor at DC
short circuit; iL cannot jump
Settled
t ≈ 5τ

Method

  1. Find the initial value just after switching: a capacitor voltage and an inductor current cannot jump.
  2. Find the final value long after switching: a capacitor acts as an open circuit, an inductor as a short circuit.
  3. Find the time constant: τ = RC or τ = L/R, using the resistance seen by the capacitor or inductor.
  4. Use x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ.

AC impedance & phasors

Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z

Method

  1. Convert the frequency: ω = 2πf.
  2. Find each reactance: XL = ωL and XC = 1/(ωC).
  3. Add impedances like resistors, with Z = R + jX.
  4. Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.

AC power & power factor

Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)

Three-phase power

Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η

Transformers

Turns ratio
a = N1/N2 = V1/V2
Current ratio
I1/I2 = N2/N1 = 1/a
Rated current
I = S/V
Referred impedance
Z1′ = a²·ZL
Copper loss at part load
Pcu = x²·Pcu,fl
Efficiency
η = x·S·pf/(x·S·pf + Pcore + x²·Pcu,fl)
Maximum efficiency
x = √(Pcore/Pcu,fl)

Op-amp circuits

Inverting amplifier
Vout = −(Rf/Rin)·Vin
Non-inverting amplifier
Vout = (1 + Rf/R1)·Vin
Summing amplifier
Vout = −Rf(V1/R1 + V2/R2)
Ideal op-amp
V+ = V−, Iin = 0

Diodes & transistors

Diode (constant drop)
VD = 0.7 V when conducting
Active region
VBE = 0.7 V, IC = β·IB, IE = (β + 1)·IB
Fixed bias
IB = (VCC − 0.7)/RB
Divider bias
IB = (VTH − 0.7)/(RTH + (β + 1)RE)
Thévenin of the divider
VTH = VCC·R2/(R1 + R2), RTH = R1∥R2
Collector loop
VCE = VCC − ICRC − IERE
Saturation
IC(sat) = (VCC − VCE(sat))/RC, IB ≥ IC(sat)/β

Number systems

Place values
binary 2k, octal 8k, hex 16k
To decimal
Σ dk·bk
From decimal
divide by the base, read the remainders bottom-up
Hex ↔ binary
one hex digit = 4 bits
Two’s complement
invert the bits and add 1

Digital logic: gates, K-maps & flip-flops

Basic gates
A·B, A + B, A′, (A·B)′, (A + B)′, A ⊕ B
Boolean rules
X + X′ = 1, X·X′ = 0, X + XY = X, XY + XY′ = X
De Morgan
(X·Y)′ = X′ + Y′, (X + Y)′ = X′·Y′
Karnaugh map order
00, 01, 11, 10 (Gray code)
Group of 2ᵏ cells
loses k variables
4-to-1 multiplexer
F = A′B′I0 + A′BI1 + AB′I2 + ABI3
Flip-flops
D: Q⁺ = D, T: Q⁺ = T ⊕ Q, JK: Q⁺ = JQ′ + K′Q
Counters
n-bit: 2ⁿ states; mod-N: smallest n with 2ⁿ ≥ N; fout = fclk/N
Ripple counter
fmax = 1/(n·tpd)
Ring and Johnson counters
n and 2n states

Method

  1. For a circuit, work from the inputs to the output one gate at a time and write the value on every wire, or write its expression and fill in the truth table.
  2. For simplification, put the 1s (and the don’t-cares as X) into a Karnaugh map with Gray-code rows and columns: 00, 01, 11, 10.
  3. Cover the 1s with as few and as large groups of 1, 2, 4, 8 or 16 cells as possible, wrapping round the edges; each group is one product term made of the variables that stay constant. Group the 0s for the POS form.
  4. For flip-flops and counters, read the inputs at each active clock edge, write the state after every edge, and remember that an n-bit counter wraps round after 2ⁿ states.

Stability: Routh–Hurwitz & root locus

Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)

Method

  1. Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
  2. Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
  3. Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
  4. For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.

Steady-state error & PID control

System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)

Method

  1. Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
  2. Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
  3. Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
  4. For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².

2Practice problems

1.Series & parallel resistorsMedium
R1​ = 10 ΩR3​ = 5 Ω+−V1​24 VR2​6 ΩIR2​AR4​5 ΩB

Find the current IR2 through R2.

V1 = 24 VR1 = 10 ΩR2 = 6 ΩR3 = 5 ΩR4 = 5 Ω
IR2 = A
2.Series & parallel resistorsHard
R1​ = 3 ΩR3​ = 25 ΩR5​ = 25 Ω+−V1​36 VR2​5 ΩAR4​6 ΩBR6​15 Ω

Find the equivalent resistance Req seen by the source V1.

V1 = 36 VR1 = 3 ΩR2 = 5 ΩR3 = 25 ΩR4 = 6 ΩR5 = 25 ΩR6 = 15 Ω
Req = Ω
3.Nodal analysisMedium
R1​ = 8 ΩR3​ = 2 Ω+−V1​18 VR2​2 ΩAR4​12 ΩBIs​2.5 A

Use nodal analysis to find the power PIs delivered by the current source Is.

V1 = 18 VIs = 2.5 AR1 = 8 ΩR2 = 2 ΩR3 = 2 ΩR4 = 12 Ω
PIs = W
4.Nodal analysisHard
R1​ = 6 ΩR2​ = 25 ΩIR2​R4​ = 5 Ω+−V1​18 VR3​12 ΩAR5​10 ΩBIs​0.5 A−+V2​6 V

Use nodal analysis to find the current IR2 through R2 in the direction of the arrow.

V1 = 18 VIs = 0.5 AV2 = 6 VR1 = 6 ΩR2 = 25 ΩR3 = 12 ΩR4 = 5 ΩR5 = 10 Ω
IR2 = A
5.Mesh analysisMedium
R1​ = 6 ΩR2​ = 2 ΩIR2​+−V1​12 VR3​12 ΩA+−V2​18 VI1​I2​

Use mesh analysis to find the current IR2 through R2 in the direction of the arrow.

V1 = 12 VV2 = 18 VR1 = 6 ΩR2 = 2 ΩR3 = 12 Ω
IR2 = A
6.Mesh analysisHard
R1​ = 12 ΩR2​ = 4 ΩR3​ = 20 Ω+−VR3​+−V1​5 VR4​5 ΩAR5​3 ΩB+−V2​6 VI1​I2​I3​

Use mesh analysis to find the voltage VR3 across R3 with the polarity shown.

V1 = 5 VV2 = 6 VR1 = 12 ΩR2 = 4 ΩR3 = 20 ΩR4 = 5 ΩR5 = 3 Ω
VR3 = V
7.SuperpositionMedium
linear circuitVs​Is​IRL​

A linear resistive circuit contains one voltage source Vs and one current source Is. The current I through a load resistor is measured twice: with Vs = 2 V and Is = 10 mA, I = 3.4 mA; with Vs = 4 V and Is = 2 mA, I = 5 mA. Find the load current I when Vs = 8 V and Is = 10 mA.

2 V, 10 mA → 3.4 mA4 V, 2 mA → 5 mAVs = 8 V, Is = 10 mA
I = mA
8.SuperpositionHard
R1​ = 3 ΩR2​ = 20 ΩR4​ = 20 Ω+−V1​12 VR3​3 ΩIR3​AIs​1 AB+−V2​6 V

Use superposition to find the power PR3 absorbed by R3.

V1 = 12 VIs = 1 AV2 = 6 VR1 = 3 ΩR2 = 20 ΩR3 = 3 ΩR4 = 20 Ω
PR3 = W
9.Thévenin & NortonMedium
R1​ = 6 ΩR3​ = 8 Ω+−V1​18 VR2​20 ΩAab

Find the Thévenin resistance Rth seen from terminals a–b.

V1 = 18 VR1 = 6 ΩR2 = 20 ΩR3 = 8 Ω
Rth = Ω
10.Thévenin & NortonHard
R1​ = 6 ΩR3​ = 12 Ω+−V1​12 VR2​30 ΩAIs​5 ABRL​3 ΩIL​

A load RL = 3 Ω is connected across a–b. Use a Thévenin equivalent to find the power PL delivered to the load.

V1 = 12 VIs = 5 AR1 = 6 ΩR2 = 30 ΩR3 = 12 ΩRL = 3 Ω
PL = W
11.RC & RL transientsMedium
R = 47 Ωt = 0L22 mHi(t)

The inductor carries a steady current of 3 A. At t = 0 the switch closes the loop through R and the source is removed, so the inductor current decays through R. Find the voltage vR across R at t = 1 ms.

i(0) = 3 AR = 47 ΩL = 22 mHt = 1 ms
vR = V
12.RC & RL transientsHard
+−Vs​5 Vt = 0R = 2.2 kΩC100 µF+−vC​vC​(0) = 15 V

Just before the switch closes at t = 0, the capacitor holds 15 V with the polarity shown. Find the capacitor voltage vC at t = 80 ms.

Vs = 5 VR = 2.2 kΩC = 100 µFvC(0) = 15 Vt = 80 ms
vC = V
13.AC impedance & phasorsMedium
100 V500 HzR = 20 ΩL = 50 mHC = 2.2 µFI

A series RLC circuit is connected to a 100 V (rms), 500 Hz supply. Find the real power P taken from the supply.

V = 100 V (rms)f = 500 HzR = 20 ΩL = 50 mHC = 2.2 µF
P = W
14.AC impedance & phasorsHard
VfR = 20 ΩL = 50 mHC = 0.47 µF

A series RLC circuit has R = 20 Ω, L = 50 mH and C = 0.47 µF. Find its quality factor Q at resonance.

R = 20 ΩL = 50 mHC = 0.47 µF
Q =
15.AC power & power factorMedium
400 V122 kW, 0.85225 kW, 0.95I

Two loads are connected in parallel to a 400 V single-phase supply: a 22 kW load at a power factor of 0.85 lagging and a 25 kW load at a power factor of 0.95 leading. Find the overall power factor cos φ seen by the supply.

V = 400 VP1 = 22 kW, pf1 = 0.85 laggingP2 = 25 kW, pf2 = 0.95 leading
cos φ =
16.AC power & power factorHard
P1​ = 42 kWQ1​S1​φ

A 150 kVA single-phase transformer supplies a load of 42 kW at a power factor of 0.6 lagging. How much extra real power ΔP can be added as a resistive (unity power factor) load before the transformer reaches its kVA rating?

Smax = 150 kVAP1 = 42 kWpf1 = 0.6
ΔP = kW
17.Three-phase powerMedium
ABCVL​ = 690 VIL​ = ?M110 kW, η = 90%cos φ = 0.8

A three-phase induction motor delivers 110 kW of mechanical output power at full load. At this load its efficiency is 90% and its power factor is 0.8 lagging. The supply has a line-to-line voltage of 690 V. Find the line current IL.

Pout = 110 kWη = 90%cos φ = 0.8VL = 690 V
IL = A
18.Three-phase powerHard
P = 300 kWφ1​S1​Q2​QC​ = ?

A balanced three-phase load takes 300 kW at a power factor of 0.78 lagging from a 415 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.9 lagging. The real power stays the same. Find the total reactive power QC the capacitor bank must supply, in kvar.

P = 300 kWpf1 = 0.78pf2 = 0.9VL = 415 Vf = 60 Hz
QC = kvar
19.TransformersMedium
RL​ = 60 Ω511200 VV2​I1​ = ?I2​

An ideal transformer with a turns ratio N₁:N₂ = 5:1 has 1200 V applied to its primary winding. A 60 Ω resistor is connected across the secondary winding. Find the primary current I1.

N1:N2 = 5:1V1 = 1200 VRL = 60 Ω
I1 = A
20.TransformersHard
pf 0.85100 kVA, η = 97.5%

A single-phase 100 kVA transformer has a core loss of 300 W. At rated load and a power factor of 0.85 lagging its efficiency is 97.5%. Find the full-load copper loss Pcu,fl in watts.

S = 100 kVAPcore = 300 Wpf = 0.85η = 97.5%
Pcu,fl = W
21.Op-amp circuitsMedium
−+Vout​Rf​ = 1 kΩR1​ = 1 kΩVin​ = 0.3 V

The op-amp is ideal and runs from ±15 V supplies. Find the output voltage Vout.

Vin = 0.3 VR1 = 1 kΩRf = 1 kΩ
Vout = V
22.Op-amp circuitsHard
Vin​V1​Vout​stage 1: invertingR1​ = 22 kΩRf1​ = 22 kΩstage 2: non-invertingR2​ = 100 kΩRf2​ = 22 kΩ

Two ideal op-amp stages are connected in cascade: an inverting amplifier (R1, Rf1) followed by a non-inverting amplifier (R2 to ground, Rf2 in the feedback). Both run from ±15 V supplies. The input is Vin = −0.4 V. Find the output voltage Vout.

R1 = 22 kΩRf1 = 22 kΩR2 = 100 kΩRf2 = 22 kΩVin = −0.4 V
Vout = V
23.Diodes & transistorsMedium
RC​ = 1 kΩβ = 80IC​ = ?RE​ = 1.2 kΩVCC​ = 15 VR1​ = 33 kΩR2​ = 4.7 kΩ

An NPN transistor with β = 80 has voltage-divider bias from VCC = 15 V: R₁ = 33 kΩ from VCC to the base and R₂ = 4.7 kΩ from the base to ground. The collector resistor is RC = 1 kΩ and the emitter resistor is RE = 1.2 kΩ. Take VBE = 0.7 V and use the Thévenin equivalent of the divider (do not neglect the base current). Find the collector current IC in mA.

VCC = 15 VR1 = 33 kΩR2 = 4.7 kΩRC = 1 kΩRE = 1.2 kΩβ = 80
IC = mA
24.Diodes & transistorsHard
+−≤ 22 V270 Ω5.1 V

A 5.1 V Zener regulator has a 270 Ω series resistor. The input can rise to 22 V, and the load may be disconnected. Find the largest power PZ,max the Zener must dissipate.

Vin,max = 22 VVZ = 5.1 VR = 270 Ω
PZ,max = mW
25.Number systemsMedium
8-bit two's complement?−128?64?32?16?8?4?2?1

Write −71 as an 8-bit two's complement pattern. Read the pattern as an unsigned binary number: what is its value U in decimal?

N = −718 bit
U =
26.Number systemsHard
click the bits to set them012806403201608040201

Set the bits to the 8-bit result of 0101 1001 >> 3. What is the result's value R in decimal?

0101 1001>> 3
R =
27.Digital logic: gates, K-maps & flip-flopsMedium
ABCD00011110000111101111111

In this Karnaugh map exactly one 1 has no neighbouring 1, so it stays a group of one cell (a full minterm of four literals) in the minimal SOP form. Neighbours across the map edges count. Click that cell.

F = Σm(3, 4, 8, 10, 11, 14, 15)
  1. 1AB = 00, CD = 00
  2. 2AB = 00, CD = 01
  3. 3AB = 00, CD = 11
  4. 4AB = 00, CD = 10
  5. 5AB = 01, CD = 00
  6. 6AB = 01, CD = 01
  7. 7AB = 01, CD = 11
  8. 8AB = 01, CD = 10
  9. 9AB = 11, CD = 00
  10. 10AB = 11, CD = 01
  11. 11AB = 11, CD = 11
  12. 12AB = 11, CD = 10
  13. 13AB = 10, CD = 00
  14. 14AB = 10, CD = 01
  15. 15AB = 10, CD = 11
  16. 16AB = 10, CD = 10
28.Digital logic: gates, K-maps & flip-flopsHard
ABCD0001111000011110X0X1131204X517X6012X13115X141819011110

Find the minimal SOP form of F(A, B, C, D) = Σm(2, 3, 7, 8, 9, 10, 15) + d(0, 1, 5, 6, 13, 14), where d marks the don't-care conditions. How many literals L does it contain?

F(A, B, C, D) = Σm(2, 3, 7, 8, 9, 10, 15) + d(0, 1, 5, 6, 13, 14)
L =
29.Laplace transformsMedium
t (s)f(t)t = 0.8f(0.8) = ?

Find f(t) for F(s) = 15/(s(s + 1)(s + 3)) by partial fractions, and evaluate f(0.8).

F(s) = 15/(s(s + 1)(s + 3))t = 0.8 s
f(0.8) =
30.Laplace transformsHard
t (s)y(t)t = 0.4y(0.4) = ?

A system obeys y″ + 3y′ + 2y = 8·u(t), with y(0) = 5 and y′(0) = 0. At t = 0 a step input u(t) = 1 is applied. Use the Laplace transform to find y(0.4).

y″ + 3y′ + 2y = 8·u(t)y(0) = 5y′(0) = 0u(t) = 1t = 0.4 s
y(0.4) =
31.Block diagramsMedium
R(s)+5(s + 3)(s + 1)(s + 7)G(s)C(s)−

A unity negative feedback loop has G(s) = 5(s + 3)/((s + 1)(s + 7)). A step of size 10 is applied at the reference. Find the steady-state error ess.

G(s) = 5(s + 3)/((s + 1)(s + 7))R = 10
ess =
32.Block diagramsHard
R(s)+9controller+D(s)+2s + 3plantC(s)−

A proportional controller K = 9 drives the plant G(s) = 2/(s + 3) in a unity negative feedback loop. A disturbance D enters at the plant input (it is added to the controller output). With R = 0, a disturbance step of size 5 is applied. Find the steady-state output css.

K = 9G(s) = 2/(s + 3)D = 5R = 0
css =
33.Step responseMedium
t (s)y(t)1tp​ = ?

A system has the transfer function G(s) = 74/(s² + 12s + 74) and receives a unit step input. Find the peak time tp of the step response.

G(s) = 74/(s² + 12s + 74)
tp = s
34.Step responseHard
R(s)+190s(s + 12)G(s)C(s)−

A unity negative feedback loop has G(s) = 190/(s(s + 12)). Find the 2 % settling time ts of the closed-loop step response, using ts ≈ 4/(ζωₙ).

G(s) = 190/(s(s + 12))
ts = s
35.Bode plots & marginsMedium
vin​L = 1 mHC = 4.7 µFR = 5 Ωvout​

In the series RLC band-pass filter shown the output is taken across R = 5 Ω, with L = 1 mH and C = 4.7 µF. Find the centre (resonant) frequency f0 in Hz.

R = 5 ΩL = 1 mHC = 4.7 µF
f0 = Hz
36.Bode plots & marginsHard
|H| (dB)0.10.1111010100100−80−60−40−2002040ω (rad/s)φ (°)ω (rad/s)−270−180−900ω180​

A unity-feedback loop has the open-loop transfer function L(s) = K/(s(s + 2)(s + 7)). Find the gain K that gives a gain margin of 15 dB.

L(s) = K/(s(s + 2)(s + 7))GM = 15 dB
K =
37.Stability: Routh–Hurwitz & root locusMedium
R(s)+Ks + 8s(s + 1)(s + 3)C(s)−

A unity-feedback loop has L(s) = K(s + 8)/(s(s + 1)(s + 3)), with K > 0. Find the largest gain Kmax for which the closed loop is stable.

L(s) = K(s + 8)/(s(s + 1)(s + 3))
Kmax =
38.Stability: Routh–Hurwitz & root locusHard
ReIm−1−2−3−4−5−6−7−8−9−101j1j2

The root locus of L(s) = K(s + 8)/(s(s + 2)) leaves the real axis between s = 0 and s = −2, circles round and joins the real axis again to the left of the zero. Find the break-away point sb.

L(s) = K(s + 8)/(s(s + 2))
sb =
39.Steady-state error & PID controlMedium
R(s)+K = 42.510s + 1C(s)−

A process G(s) = 2.5/(10s + 1) is controlled by a proportional gain K = 4 in a unity-feedback loop. Find the steady-state error ess for a step, as a percentage of the step size.

G(s) = 2.5/(10s + 1)K = 4
ess = %
40.Steady-state error & PID controlHard
R(s)+K = 401s(s + 2)C(s)−

A proportional controller K = 40 drives the plant G(s) = 1/(s(s + 2)) in a unity-feedback loop. Find the peak time tp of the step response.

G(s) = 1/(s(s + 2))K = 40
tp = s

3Solutions

1.Series & parallel resistors

Answer: IR2 = 1.091 A

Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.

R1​ = 10 ΩR3​ = 5 Ω+−V1​24 VR2​6 ΩAR4​5 ΩB

Combine resistors from the far end

Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.

R3 + R4 = 5 + 5 = 10 Ω
R2 ∥ 10 = 6·10/(6+10) = 3.75 Ω
Req = R1 + 3.75 = 10 + 3.75 = 13.75 Ω

Current from the source

The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.

IR1 = V1/Req = 24/13.75 = 1.745 A

Current through R₂

Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.

VA = V1 − IR1·R1 = 24 − 1.745·10 = 6.545 V
IR2 = VA/R2 = 6.545/6 = 1.091 A

Answer

IR2 = 1.091 A
2.Series & parallel resistors

Answer: Req = 7.29 Ω

Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.

R1​ = 3 ΩR3​ = 25 ΩR5​ = 25 Ω+−V1​36 VR2​5 ΩAR4​6 ΩBR6​15 Ω

Combine resistors from the far end

Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.

R5 + R6 = 25 + 15 = 40 Ω
R4 ∥ 40 = 5.217 Ω
R3 + 5.217 = 30.22 Ω
R2 ∥ 30.22 = 4.29 Ω
Req = R1 + 4.29 = 3 + 4.29 = 7.29 Ω

Answer

Req = 7.29 Ω
3.Nodal analysis

Answer: PIs = 24.23 W

Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.

KCL at node A

Currents leaving A through the resistors equal the current pushed into A by sources.

VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/2 + (VA − 18)/8 + (VA − VB)/2 = 0
1.125·VA − 0.5·VB = 2.25

KCL at node B

Currents leaving B through the resistors equal the current pushed into B by sources.

VB/R4 + (VB − VA)/R3 = Is
VB/12 + (VB − VA)/2 = 2.5
−0.5·VA + 0.5833·VB = 2.5

Solve

Δ = (1.125)(0.5833) − (−0.5)(−0.5) = 0.4063
VA = Δ1/Δ = 2.563/0.4063 = 6.308 V
VB = Δ2/Δ = 3.938/0.4063 = 9.692 V

Power delivered by the current source

The source pushes Iₛ up into node B, from ground (0 V) to VB. A source whose current leaves its + end delivers P = V·I.

PIs = VB·Is = 9.692·2.5 = 24.23 W

Answer

PIs = 24.23 W
4.Nodal analysis

Answer: IR2 = 0.5464 A

Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.

R1​ = 6 ΩR2​ = 25 ΩR4​ = 5 Ω+−V1​18 VR3​12 ΩAR5​10 ΩBIs​0.5 A−+V2​6 V

Set up the nodes

Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 18 V, V2 = −6 V). Unknowns: VA, VB.

KCL at node A

Currents leaving A through the resistors equal the current pushed into A by sources.

VA/R3 + (VA − V1)/R1 + (VA − VB)/R2 = 0
VA/12 + (VA − 18)/6 + (VA − VB)/25 = 0
0.29·VA − 0.04·VB = 3

KCL at node B

Currents leaving B through the resistors equal the current pushed into B by sources.

VB/R5 + (VB − VA)/R2 + (VB − V2)/R4 = Is
VB/10 + (VB − VA)/25 + (VB − (−6))/5 = (−0.5)
−0.04·VA + 0.34·VB = −1.7

Solve

Δ = (0.29)(0.34) − (−0.04)(−0.04) = 0.097
VA = Δ1/Δ = 0.952/0.097 = 9.814 V
VB = Δ2/Δ = −0.373/0.097 = −3.845 V

Answer

IR2 = (VA − VB)/R2 = (9.814 − −3.845)/25 = 0.5464 A
5.Mesh analysis

Answer: IR2 = −1.667 A

Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.

R1​ = 6 ΩR2​ = 2 Ω+−V1​12 VR3​12 ΩA+−V2​18 VI1​I2​

Assign mesh currents

Draw a clockwise current in each window: I1, I2. A resistor shared by two meshes carries the difference of their currents.

KVL around mesh 1

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R1·I1 + R3(I1 − I2) = V1
6·I1 + 12(I1 − I2) = 12
18·I1 − 12·I2 = 12

KVL around mesh 2

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R2·I2 + R3(I2 − I1) = −V2
2·I2 + 12(I2 − I1) = (−18)
−12·I1 + 14·I2 = −18

Solve

Δ = (18)(14) − (−12)(−12) = 108
I1 = Δ1/Δ = −48/108 = −0.4444 A
I2 = Δ2/Δ = −180/108 = −1.667 A

Answer

IR2 = I2 = −1.667 A

A negative mesh current flows anticlockwise.

6.Mesh analysis

Answer: VR3 = −5.04 V

Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.

R1​ = 12 ΩR2​ = 4 ΩR3​ = 20 Ω+−V1​5 VR4​5 ΩAR5​3 ΩB+−V2​6 VI1​I2​I3​

Assign mesh currents

Draw a clockwise current in each window: I1, I2, I3. A resistor shared by two meshes carries the difference of their currents.

KVL around mesh 1

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R1·I1 + R4(I1 − I2) = V1
12·I1 + 5(I1 − I2) = 5
17·I1 − 5·I2 = 5

KVL around mesh 2

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R2·I2 + R4(I2 − I1) + R5(I2 − I3) = 0
4·I2 + 5(I2 − I1) + 3(I2 − I3) = 0
−5·I1 + 12·I2 − 3·I3 = 0

KVL around mesh 3

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R3·I3 + R5(I3 − I2) = −V2
20·I3 + 3(I3 − I2) = (−6)
−3·I2 + 23·I3 = −6

Solve

Δ = det of the coefficient matrix = 3964
I1 = Δ1/Δ = 1245/3964 = 0.3141 A
I2 = Δ2/Δ = 269/3964 = 0.06786 A
I3 = Δ3/Δ = −999/3964 = −0.252 A

Answer

IR3 = I3 = −0.252 A
VR3 = IR3·R3 = −0.252·20 = −5.04 V

A negative mesh current flows anticlockwise.

7.Superposition

Answer: I = 10.6 mA

Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.

Write the response as a sum of contributions

Each contribution is proportional to its own source, with a constant that depends only on the resistors.

I = k₁·Vs + k₂·Is
2·k₁ + 10·k₂ = 3.4
4·k₁ + 2·k₂ = 5

Solve for the constants

Δ = (2)(2) − (10)(4) = −36
k₁ = Δ1/Δ = −43.2/−36 = 1.2
k₂ = Δ2/Δ = −3.6/−36 = 0.1
k₁ = 1.2 mA/V, k₂ = 0.1

Predict the new current

I = 1.2·8 + 0.1·10 = 10.6 mA

Answer

I = 10.6 mA
8.Superposition

Answer: PR3 = 15.07 W

Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.

R1​ = 3 ΩR2​ = 20 ΩR4​ = 20 Ω+−V1​12 VR3​3 ΩAOPENBSHORT

Case 1 · V1 acting alone

V₂ becomes a short and Iₛ an open circuit. Seen from A, R₃ is in parallel with the series pair R₂+R₄.

R3 ∥ (R2+R4) = 3 ∥ 40 = 2.791 Ω
VA = 12·2.791/(3+2.791) = 5.783 V
VB = VA·R4/(R2+R4) = 5.783·20/40 = 2.892 V
IR3′ = (VA − 0)/R3 = (5.783 − 0)/3 = 1.928 A
R1​ = 3 ΩR2​ = 20 ΩR4​ = 20 ΩSHORTR3​3 ΩAIs​1 ABSHORT

Case 2 · Is acting alone

Both voltage sources become shorts. Iₛ splits at B between R₄ (now to ground) and R₂ in series with R₁ ∥ R₃.

R1 ∥ R3 = 1.5 Ω, so the left path is R2+1.5 = 21.5 Ω
Req = R4 ∥ 21.5 = 10.36 Ω
VB = Is·Req = 1·10.36 = 10.36 V
VA = VB·1.5/21.5 = 0.7229 V
IR3″ = (VA − 0)/R3 = (0.7229 − 0)/3 = 0.241 A
R1​ = 3 ΩR2​ = 20 ΩR4​ = 20 ΩSHORTR3​3 ΩAOPENB+−V2​6 V

Case 3 · V2 acting alone

V₁ becomes a short and Iₛ an open circuit. R₁ ∥ R₃ hangs from A, in series with R₂ back to B.

R1 ∥ R3 = 3·3/(3+3) = 1.5 Ω
VB = V2·(R2+R1∥R3)/(R4+R2+R1∥R3) = 6·21.5/41.5 = 3.108 V
VA = VB·(R1∥R3)/(R2+R1∥R3) = 3.108·1.5/21.5 = 0.2169 V
IR3‴ = (VA − 0)/R3 = (0.2169 − 0)/3 = 0.07229 A

Add the current contributions

IR3 = IR3′ + IR3″ + IR3‴ = 1.928 + 0.241 + 0.07229 = 2.241 A

Power in the resistor

Power depends on the square of the current, so it does not obey superposition: add the currents first, then square.

PR3 = IR3²·R3 = 2.241²·3 = 15.07 W

Answer

PR3 = 15.07 W

Adding the powers of the separate cases would give 11.34 W, which is wrong.

9.Thévenin & Norton

Answer: Rth = 12.62 Ω

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 6 ΩR3​ = 8 ΩSHORTR2​20 ΩAabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 6·20/(6+20) = 4.615 Ω
Rth = (R1 ∥ R2) + R3 = 4.615 + 8 = 12.62 Ω
10.Thévenin & Norton

Answer: PL = 67.69 W

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 6 ΩR3​ = 12 ΩSHORTR2​30 ΩAOPENBabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 6·30/(6+30) = 5 Ω
Rth = (R1 ∥ R2) + R3 = 5 + 12 = 17 Ω
R1​ = 6 ΩR3​ = 12 Ω+−V1​12 VR2​30 ΩAIs​5 ABab+−Vth​

Find Vth, the open-circuit voltage

With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.

VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 10 + 5·5 = 35 V
Vth = VB = VA + Is·R3 = 35 + 5·12 = 95 V
Rth​ = 17 Ω+−Vth​95 VRL​3 ΩIL​

Connect the load to the Thévenin equivalent

The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.

IL = Vth/(Rth + RL) = 95/(17 + 3) = 4.75 A
PL = IL²·RL = 4.75²·3 = 67.69 W
11.RC & RL transients

Answer: vR = 16.65 V

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Time constant

τ = L/R = 22 mH / 47 Ω = 0.4681 ms

Decay of the current

i(t) = 3·e−1/0.4681 = 0.3543 A
vR = R·i = 47·0.3543 = 16.65 V

Answer

vR = 16.65 V
12.RC & RL transients

Answer: vC = 11.95 V

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Initial value, final value, time constant

The capacitor voltage cannot jump, so it starts at its stored value and heads for the source voltage.

vC(0) = 15 V, vC(∞) = Vs = 5 V
τ = R·C = 2.2 kΩ · 100 µF = 220 ms
vC(t) = 5 + (15 − 5)·e−t/τ

Voltage at the given time

vC(80) = 5 + (10)·e−80/220 = 11.95 V

Answer

vC = 11.95 V
13.AC impedance & phasors

Answer: P = 361.3 W

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactances

XL = 157.1 Ω, XC = 144.7 Ω

Impedance

|Z| = √(20² + (12.39)²) = 23.53 Ω

Real power

Inductors and capacitors only store and return energy; the resistor absorbs all of the real power.

I = 100/23.53 = 4.25 A
P = I²·R = 4.25²·20 = 361.3 W

Answer

P = 361.3 W
14.AC impedance & phasors

Answer: Q = 16.31

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Resonant frequency

f0 = 1/(2π·√(0.05·0.47·10⁻⁶)) = 1038 Hz

Quality factor

Q compares the reactance at resonance with the resistance: Q = ω₀L/R.

Q = (1/R)·√(L/C) = (1/20)·√(0.05/(0.47·10⁻⁶)) = 16.31

Answer

Q = 16.31
15.AC power & power factor

Answer: cos φ = 0.9934

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Reactive power of each load

A lagging load takes reactive power (Q > 0); a leading load supplies it (Q < 0).

Q1 = 22·tan(arccos 0.85) = 13.63 kvar
Q2 = −25·tan(arccos 0.95) = −8.217 kvar

Totals

P = 22 + 25 = 47 kW
Q = 13.63 + (−8.217) = 5.417 kvar
S = √(47² + 5.417²) = 47.31 kVA

Overall power factor

cos φ = P/S = 47/47.31 = 0.9934 lagging

Answer

cos φ = 0.9934
16.AC power & power factor

Answer: ΔP = 97.15 kW

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Reactive power of the existing load

Q1 = 42·tan(arccos 0.6) = 56 kvar

Largest total real power

At full rating S = Smax, and Q is unchanged by the resistive load.

P = √(Smax² − Q1²) = √(150² − 56²) = 139.2 kW

Extra real power

ΔP = 139.2 − 42 = 97.15 kW

Answer

ΔP = 97.15 kW
17.Three-phase power

Answer: IL = 127.8 A

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.

Electrical input power

Pin = Pout/η = 110/0.9 = 122.2 kW

Line current

IL = Pin/(√3·VL·cos φ) = 122222/(√3·690·0.8) = 127.8 A

Answer

IL = 127.8 A
18.Three-phase power

Answer: QC = 95.39 kvar

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.

Reactive power before and after

The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.

Q1 = 300·tan(acos 0.78) = 300·0.8023 = 240.7 kvar
Q2 = 300·tan(acos 0.9) = 300·0.4843 = 145.3 kvar

Reactive power from the capacitors

QC = Q1 − Q2 = 95.39 kvar

Answer

QC = 95.39 kvar
19.Transformers

Answer: I1 = 0.8 A

Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.

Secondary voltage and current

V2 = 1200/5 = 240 V
I2 = 240/60 = 4 A

Primary current

An ideal transformer has no losses: V₁·I₁ = V₂·I₂.

I1 = I2/5 = 0.8 A

Answer

I1 = 0.8 A

Check: the load seen from the primary is a²·RL = 1500 Ω, and 1200/1500 gives the same current.

20.Transformers

Answer: Pcu,fl = 1879 W

Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.

Output and input power

Pout = 100·0.85 = 85 kW
Pin = 85000/0.975 = 87179 W

Total and copper losses

Ploss = 87179 − 85000 = 2179 W
Pcu,fl = 2179 − 300 = 1879 W

Answer

Pcu,fl = 1879 W
21.Op-amp circuits

Answer: Vout = 0.6 V

Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.

Inverting input follows the input

V₋ = V₊ = 0.3 V
I = V₋/R1 = 0.3/1 = 0.3 mA

Output voltage

The current through R₁ also flows through Rf.

Vout = V₋ + I·Rf = 0.3 + 0.3·1 = 0.6 V

Answer

Vout = 0.6 V
22.Op-amp circuits

Answer: Vout = 0.488 V

Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.

Gain of each stage

A1 = −Rf1/R1 = −22/22 = −1
A2 = 1 + Rf2/R2 = 1 + 22/100 = 1.22

Stage by stage

V1 = −1·(−0.4) = 0.4 V
Vout = 1.22·0.4 = 0.488 V

Answer

Vout = 0.488 V
23.Diodes & transistors

Answer: IC = 0.9239 mA

BJT bias point: in the active region VBE = 0.7 V, IC = β·IB and IE = (β + 1)·IB. Find IB from the base loop with KVL, then IC, then VCE from the collector–emitter loop. A voltage divider at the base is replaced by its Thévenin equivalent VTH = VCC·R₂/(R₁ + R₂), RTH = R₁∥R₂; an emitter resistor appears (β + 1) times larger in the base loop.

Thévenin equivalent of the divider

VTH = 15·4.7/(33 + 4.7) = 1.87 V
RTH = 33·4.7/(33 + 4.7) = 4.114 kΩ

Base current

KVL around the base loop; the emitter current is (β + 1)·IB.

IB = (1.87 − 0.7)/(4.114 + 81·1.2) = 11.55 µA

Collector current

IC = 80·11.55 µA = 0.9239 mA
IE = 81·11.55 µA = 0.9354 mA

Answer

IC = 0.9239 mA
24.Diodes & transistors

Answer: PZ,max = 319.2 mW

Zener regulator: a reverse-biased Zener diode holds its voltage VZ while its current stays above a minimum IZ,min. The series resistor R takes the difference between input and output: IR = (Vin − VZ)/R. That current splits between the load, IL = VZ/RL, and the Zener: IZ = IR − IL. Design for the worst cases: the lowest input with the largest load must still leave IZ,min, and the highest input with no load gives the largest Zener power PZ = VZ·IZ.

Worst-case Zener current

IZ = 16.9/270 = 62.59 mA

Zener power

PZ = 5.1·62.59 = 319.2 mW

Answer

PZ,max = 319.2 mW
25.Number systems

Answer: U = 185

Positional number systems: each digit is worth its value times a power of the base. In binary the places are worth 1, 2, 4, 8, 16, …; in hexadecimal 1, 16, 256, …, with A–F standing for 10–15. In 8-bit two's complement the leftmost bit is worth −128 instead of +128, which is how negative numbers are stored.

Invert and add one

71 = 0100 0111
inverted: 1011 1000
+1 → 1011 1001

Read it as unsigned

1011 1001₂ = 256 − 71 = 185

Answer

U = 185
26.Number systems

Answer: R = 11

Setting bits: each bit is worth a power of two (128, 64, …, 1). One hex digit is exactly four bits, and in 8-bit two's complement the leftmost bit is worth −128. Bitwise operations work on each bit position separately.

Bit by bit

Shifting right by 3 moves every bit 3 places to the right; bits that fall off the right end are lost and zeros come in on the left.

0101 1001 >> 3
= 0000 1011

Value of the result

0000 1011₂ = 11

Answer

R = 11
27.Digital logic: gates, K-maps & flip-flops

Answer: AB = 01, CD = 00

Karnaugh maps: the cells are ordered in Gray code (00, 01, 11, 10), so neighbouring cells, including the ones across the edges, differ in exactly one variable. Group the 1s in rectangles of 1, 2, 4, 8 or 16 cells, as large as possible and as few as possible, until every 1 is covered. Each group is one product term: the variables that stay constant inside it. A group of 2ᵏ cells loses k variables. Don't-cares (X) may be used to make groups bigger but never have to be covered. Grouping the 0s instead gives the minimal POS form.

Neighbours of each 1

A 1 with a neighbouring 1 can join a group of two or more.

m4: m5, m6, m0, m12 → 0
ABCD00011110000111101111111

The isolated 1

m4 = A′BC′D′ → AB = 01, CD = 00

Answer

AB = 01, CD = 00
28.Digital logic: gates, K-maps & flip-flops

Answer: L = 8

Karnaugh maps: the cells are ordered in Gray code (00, 01, 11, 10), so neighbouring cells, including the ones across the edges, differ in exactly one variable. Group the 1s in rectangles of 1, 2, 4, 8 or 16 cells, as large as possible and as few as possible, until every 1 is covered. Each group is one product term: the variables that stay constant inside it. A group of 2ᵏ cells loses k variables. Don't-cares (X) may be used to make groups bigger but never have to be covered. Grouping the 0s instead gives the minimal POS form.

Prime implicants

The largest groups that can be formed from 1s and Xs.

C′D, CD′, B′D′, BD, B′C′, BC, A′D, A′C, A′B′
ABCD0001111000011110X0X1131204X517X6012X13115X141819011110

Minimal cover

F = C′D + B′D′ + BD + A′D
L = 8

Answer

L = 8

Another grouping of the same size exists; it has the same number of terms and literals.

29.Laplace transforms

Answer: f(0.8) = 1.857

Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).

Partial fractions

F(s) = A/s + B/(s + 1) + C/(s + 3)
A = 15/(1·3) = 5
B = 15/((−1)·2) = −7.5
C = 15/((−3)·(−2)) = 2.5

Inverse transform

f(t) = 5 − 7.5·e−t + 2.5·e−3t

Evaluate

f(0.8) = 5 − 7.5·e−0.8 + 2.5·e−3·0.8 = 1.857

Answer

f(0.8) = 1.857
30.Laplace transforms

Answer: y(0.4) = 4.891

Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).

Transform the equation

(s² + 3s + 2)·Y(s) = 5s + 15 + 8/s
Y(s) = (5s² + 15s + 8)/(s(s + 1)(s + 2))

Partial fractions

A = 8/(1·2) = 4
B = −2/((−1)·1) = 2
C = −2/((−2)·(−1)) = −1

Result

y(t) = 4 + 2·e−t − e−2t
y(0.4) = 4.891

Answer

y(0.4) = 4.891

Check: y(0) = A + B + C = 5.

31.Block diagrams

Answer: ess = 3.182

Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).

Position error constant

Kₚ = G(0) = 5·3/(1·7) = 2.143

Steady-state error

ess = A/(1 + Kₚ) = 10/(1 + 2.143) = 3.182

Answer

ess = 3.182
32.Block diagrams

Answer: css = 0.4762

Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).

Transfer functions

C/D = G/(1 + K·G) = 2/(s + 3 + 18)

Steady state

css = 5·2/21 = 0.4762

Answer

css = 0.4762

A larger K reduces the effect of the disturbance, but never to zero with a proportional controller.

33.Step response

Answer: tp = 0.5096 s

Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).

Compare with the standard form

The denominator must match s² + 2ζωₙs + ωₙ².

ωₙ² = 74 → ωₙ = 8.602 rad/s
2ζωₙ = 12 → ζ = 12/(2·8.602) = 0.6975

Result

ωd = 8.602·√(1 − 0.6975²) = 6.164 rad/s → tp = π/ωd = 0.5096 s

Answer

tp = 0.5096 s
34.Step response

Answer: ts = 0.6667 s

Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).

Closed-loop transfer function

T(s) = 190/(s² + 12s + 190): ωₙ = 13.78 rad/s, ζ = 0.4353

Settling time

ζωₙ = 12/2 = 6
ts ≈ 4/(ζωₙ) = 0.6667 s

Answer

ts = 0.6667 s

For this loop ζωₙ = a/2 whatever K is: raising K adds overshoot but does not shorten the settling time.

35.Bode plots & margins

Answer: f0 = 2322 Hz

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Resonant frequency

ω₀ = 1/√(LC) = 1/√(0.001·4.7 × 10⁻⁶) = 14586 rad/s
f₀ = ω₀/(2π) = 2322 Hz

Answer

f0 = 2322 Hz
36.Bode plots & margins

Answer: K = 22.41

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Phase crossover

(ω/2)·(ω/7) = 1 → ω180 = √(2·7) = 3.742 rad/s

Magnitude at phase crossover

|L(jω180)| = K/(ω·√(ω² + 4)·√(ω² + 49)) = K/(2·7·(2 + 7)) = K/126

Required gain

126/K = 1015/20 = 5.623
K = 126/5.623 = 22.41

Answer

K = 22.41
37.Stability: Routh–Hurwitz & root locus

Answer: Kmax = 3

Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.

Characteristic polynomial

s(s + 1)(s + 3) + K(s + 8) = s³ + 4s² + (3 + K)s + 8K

Routh array

s³: 1, 3 + K
s²: 4, 8K
s¹: (4·(3 + K) − 8K)/4
s⁰: 8K

Condition

12 − 4K > 0
K < 12/4 = 3

Answer

Kmax = 3

With the zero to the right of s = −4 the loop would stay stable for every K > 0.

38.Stability: Routh–Hurwitz & root locus

Answer: sb = −1.072

Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.

Gain along the real axis

K(s) = −(s² + 2s)/(s + 8)

Stationary points

Differentiate with the quotient rule and set the numerator to zero.

(2s + 2)(s + 8) − (s² + 2s) = s² + 16s + 16 = 0
s = −8 ± √48 = −1.072, −14.93

Break-away point

sb = −1.072

Answer

sb = −1.072

Between the two break points the locus is a circle centred on the zero, with radius √48 = 6.928.

39.Steady-state error & PID control

Answer: ess = 9.091 %

Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.

Position constant

Kp = 4·2.5 = 10

Step error

ess = 100/(1 + 10) = 9.091 %

Answer

ess = 9.091 %
40.Steady-state error & PID control

Answer: tp = 0.5031 s

P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).

Characteristic polynomial

s(s + 2) + 40·1 = s² + 2s + 40

ωₙ and ζ

ωₙ = √40 = 6.325 rad/s
ζ = 2/(2·6.325) = 0.1581

Peak time

ωd = 6.325·√(1 − 0.1581²) = 6.245 rad/s
tp = π/6.245 = 0.5031 s

Answer

tp = 0.5031 s

This is independent practice material. ExamProblems is not affiliated with or endorsed by the organisation that runs this exam, and the exam name is used only to describe the content. The FE exam is run by NCEES, which is not affiliated with ExamProblems and does not endorse it.

ExamProblems · examproblems.com/courses/fe-exam-electrical