FE Electrical and Computer exam practice: cram pack

Formula sheets, the key method steps for every topic and 40 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

Series & parallel resistors

Resistors in series
Req = R1 + R2 + …
Resistors in parallel
1/Req = 1/R1 + 1/R2 + …
Two in parallel
Req = R1R2 / (R1 + R2)
Ohm's law
V = I·R
Power
P = V·I = I²R = V²/R

Method

  1. Start at the end of the network furthest from the terminals.
  2. Combine resistors in series by adding them, and resistors in parallel with 1/R = 1/R₁ + 1/R₂ + …
  3. Redraw the circuit after each step.
  4. Repeat until one resistor is left between the terminals.

Nodal analysis

Kirchhoff’s current law
ΣIin = ΣIout
Branch current
I = (Va − Vb)/R
Reference node
Vground = 0

Method

  1. Choose a reference node (ground) and label the other node voltages.
  2. Write Kirchhoff’s current law at every unknown node: currents leaving through each branch equal the currents entering.
  3. Express every branch current as (Va − Vb)/R.
  4. Solve the system of equations, then find any current you need.

Mesh analysis

Kirchhoff’s voltage law
ΣV = 0 around every loop
Shared resistor
current = I1 − I2
Current source in a mesh
fixes that mesh current

Method

  1. Draw a clockwise current in every mesh (window) of the circuit.
  2. Apply Kirchhoff’s voltage law around each mesh: the sum of voltage drops is zero.
  3. In a resistor shared by two meshes the current is the difference of the two mesh currents.
  4. Solve the equations; a negative result means the current flows the other way.

Superposition

Superposition
x = x1 + x2 + … (one source at a time)
Switched-off voltage source
short circuit (0 V)
Switched-off current source
open circuit (0 A)
Voltage divider
V2 = V·R2/(R1 + R2)
Current divider
I1 = I·R2/(R1 + R2)

Method

  1. Count the independent sources. You will solve one simpler circuit per source.
  2. Keep one source and switch off the others: a voltage source becomes a short circuit (a wire), a current source becomes an open circuit (a gap).
  3. Solve the simpler circuit for the voltage or current you need, keeping track of its direction.
  4. Repeat for every source, then add the contributions with their signs.

Thévenin & Norton

Thévenin voltage
Vth = Vopen circuit
Thévenin resistance
Rth: all sources off, seen from a–b
Norton current
IN = Vth/Rth
Load current
IL = Vth/(Rth + RL)
Maximum power transfer
RL = Rth, Pmax = Vth²/(4Rth)

Method

  1. Remove the load and mark the two terminals a and b.
  2. Find the open-circuit voltage between a and b: this is Vth.
  3. Switch off all independent sources and find the resistance seen from a–b: this is Rth.
  4. Put the load back on the equivalent circuit: Vth in series with Rth.
  5. For the Norton equivalent, convert: IN = Vth/Rth, with RN = Rth in parallel.

RC & RL transients

Time constant
τ = RC | τ = L/R
Response
x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ
Capacitor at DC
open circuit; vC cannot jump
Inductor at DC
short circuit; iL cannot jump
Settled
t ≈ 5τ

Method

  1. Find the initial value just after switching: a capacitor voltage and an inductor current cannot jump.
  2. Find the final value long after switching: a capacitor acts as an open circuit, an inductor as a short circuit.
  3. Find the time constant: τ = RC or τ = L/R, using the resistance seen by the capacitor or inductor.
  4. Use x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ.

AC impedance & phasors

Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z

Method

  1. Convert the frequency: ω = 2πf.
  2. Find each reactance: XL = ωL and XC = 1/(ωC).
  3. Add impedances like resistors, with Z = R + jX.
  4. Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.

AC power & power factor

Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)

Three-phase power

Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η

Transformers

Turns ratio
a = N1/N2 = V1/V2
Current ratio
I1/I2 = N2/N1 = 1/a
Rated current
I = S/V
Referred impedance
Z1′ = a²·ZL
Copper loss at part load
Pcu = x²·Pcu,fl
Efficiency
η = x·S·pf/(x·S·pf + Pcore + x²·Pcu,fl)
Maximum efficiency
x = √(Pcore/Pcu,fl)

Op-amp circuits

Inverting amplifier
Vout = −(Rf/Rin)·Vin
Non-inverting amplifier
Vout = (1 + Rf/R1)·Vin
Summing amplifier
Vout = −Rf(V1/R1 + V2/R2)
Ideal op-amp
V+ = V−, Iin = 0

Diodes & transistors

Diode (constant drop)
VD = 0.7 V when conducting
Active region
VBE = 0.7 V, IC = β·IB, IE = (β + 1)·IB
Fixed bias
IB = (VCC − 0.7)/RB
Divider bias
IB = (VTH − 0.7)/(RTH + (β + 1)RE)
Thévenin of the divider
VTH = VCC·R2/(R1 + R2), RTH = R1∥R2
Collector loop
VCE = VCC − ICRC − IERE
Saturation
IC(sat) = (VCC − VCE(sat))/RC, IB ≥ IC(sat)/β

Number systems

Place values
binary 2k, octal 8k, hex 16k
To decimal
Σ dk·bk
From decimal
divide by the base, read the remainders bottom-up
Hex ↔ binary
one hex digit = 4 bits
Two’s complement
invert the bits and add 1

Digital logic: gates, K-maps & flip-flops

Basic gates
A·B, A + B, A′, (A·B)′, (A + B)′, A ⊕ B
Boolean rules
X + X′ = 1, X·X′ = 0, X + XY = X, XY + XY′ = X
De Morgan
(X·Y)′ = X′ + Y′, (X + Y)′ = X′·Y′
Karnaugh map order
00, 01, 11, 10 (Gray code)
Group of 2ᵏ cells
loses k variables
4-to-1 multiplexer
F = A′B′I0 + A′BI1 + AB′I2 + ABI3
Flip-flops
D: Q⁺ = D, T: Q⁺ = T ⊕ Q, JK: Q⁺ = JQ′ + K′Q
Counters
n-bit: 2ⁿ states; mod-N: smallest n with 2ⁿ ≥ N; fout = fclk/N
Ripple counter
fmax = 1/(n·tpd)
Ring and Johnson counters
n and 2n states

Method

  1. For a circuit, work from the inputs to the output one gate at a time and write the value on every wire, or write its expression and fill in the truth table.
  2. For simplification, put the 1s (and the don’t-cares as X) into a Karnaugh map with Gray-code rows and columns: 00, 01, 11, 10.
  3. Cover the 1s with as few and as large groups of 1, 2, 4, 8 or 16 cells as possible, wrapping round the edges; each group is one product term made of the variables that stay constant. Group the 0s for the POS form.
  4. For flip-flops and counters, read the inputs at each active clock edge, write the state after every edge, and remember that an n-bit counter wraps round after 2ⁿ states.

Stability: Routh–Hurwitz & root locus

Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)

Method

  1. Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
  2. Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
  3. Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
  4. For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.

Steady-state error & PID control

System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)

Method

  1. Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
  2. Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
  3. Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
  4. For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².

2Practice problems

1.Series & parallel resistorsMedium
R1​ = 3 ΩR3​ = 20 Ω+−V1​9 VR2​8 ΩIR2​AR4​12 ΩB

Find the current IR2 through R2.

V1 = 9 VR1 = 3 ΩR2 = 8 ΩR3 = 20 ΩR4 = 12 Ω
IR2 = A
2.Series & parallel resistorsHard
R1​ = 20 ΩIR1​R3​ = 3 ΩR5​ = 8 Ω+−V1​15 VR2​2 ΩAR4​30 ΩBR6​10 Ω

Find the current IR1 delivered by the source, which flows through R1.

V1 = 15 VR1 = 20 ΩR2 = 2 ΩR3 = 3 ΩR4 = 30 ΩR5 = 8 ΩR6 = 10 Ω
IR1 = A
3.Nodal analysisMedium
R1​8 Ω−+V1​30 VR2​3 Ω+−V2​12 VI2​R3​12 Ω+−V3​18 VA

Three branches are connected between node A and ground, as shown. Use nodal analysis to find the current I2 in branch 2, flowing up into node A in the direction of the arrow.

V1 = 30 VR1 = 8 ΩV2 = 12 VR2 = 3 ΩV3 = 18 VR3 = 12 Ω
I2 = A
4.Nodal analysisHard
R1​ = 8 ΩR2​ = 30 ΩR4​ = 4 ΩIR4​+−V1​24 VR3​4 ΩAR5​12 ΩBIs​6 A−+V2​15 V

Use nodal analysis to find the current IR4 through R4 in the direction of the arrow.

V1 = 24 VIs = 6 AV2 = 15 VR1 = 8 ΩR2 = 30 ΩR3 = 4 ΩR4 = 4 ΩR5 = 12 Ω
IR4 = A
5.Mesh analysisMedium
R1​ = 4 ΩR2​ = 4 Ω+−VR2​+−V1​9 VR3​4 ΩA+−V2​9 VI1​I2​

Use mesh analysis to find the voltage VR2 across R2 with the polarity shown.

V1 = 9 VV2 = 9 VR1 = 4 ΩR2 = 4 ΩR3 = 4 Ω
VR2 = V
6.Mesh analysisHard
R1​ = 5 ΩR2​ = 30 ΩR3​ = 6 Ω+−V1​15 VR4​30 ΩAR5​12 ΩB+−V2​12 VI1​I2​I3​

Use mesh analysis to find the mesh current I2 (clockwise).

V1 = 15 VV2 = 12 VR1 = 5 ΩR2 = 30 ΩR3 = 6 ΩR4 = 30 ΩR5 = 12 Ω
I2 = A
7.SuperpositionMedium
R1​ = 15 ΩR3​ = 15 Ω+−V1​18 VR2​20 ΩIR2​AR4​3 ΩBIs​2.5 A

Use superposition to find the current IR2 through R2 in the direction of the arrow.

V1 = 18 VIs = 2.5 AR1 = 15 ΩR2 = 20 ΩR3 = 15 ΩR4 = 3 Ω
IR2 = A
8.SuperpositionHard
R1​ = 15 ΩR2​ = 2 ΩR4​ = 5 Ω+−V1​30 VR3​20 ΩIR3​AIs​6 AB+−V2​?

Find the value of the voltage source V2 (polarity as shown) that makes the current IR3 through R3 equal to zero.

V1 = 30 VIs = 6 AR1 = 15 ΩR2 = 2 ΩR3 = 20 ΩR4 = 5 Ω
V2 = V
9.Thévenin & NortonMedium
R1​ = 10 ΩR3​ = 6 Ω+−V1​30 VR2​5 ΩARL​8 ΩIL​B

A load RL = 8 Ω is connected across a–b. Replace the rest of the circuit with its Thévenin equivalent and find the load current IL.

V1 = 30 VR1 = 10 ΩR2 = 5 ΩR3 = 6 ΩRL = 8 Ω
IL = A
10.Thévenin & NortonHard
R1​ = 2 ΩR3​ = 5 Ω+−V1​12 VR2​4 ΩAIs​5 ABab

Find the Thévenin voltage Vth seen from terminals a–b.

V1 = 12 VIs = 5 AR1 = 2 ΩR2 = 4 ΩR3 = 5 Ω
Vth = V
11.RC & RL transientsMedium
+−Vs​6 Vt = 0R = 100 ΩL47 mHi(t)

The inductor carries no current before the switch closes at t = 0. Find the voltage vL across the inductor at t = 1 ms.

Vs = 6 VR = 100 ΩL = 47 mHt = 1 ms
vL = V
12.RC & RL transientsHard
+−Vs​15 VR1​ = 47 ΩR2​ = 33 Ωopens at t = 0L33 mHi(t)

The switch across R2 has been closed for a long time, so the inductor current is steady. At t = 0 the switch opens. Find the inductor current i at t = 1 ms.

Vs = 15 VR1 = 47 ΩR2 = 33 ΩL = 33 mHt = 1 ms
i = A
13.AC impedance & phasorsMedium
50 V50 HzR = 10 ΩL = 50 mHC = 47 µFI

A series RLC circuit is connected to a 50 V (rms), 50 Hz supply. Find the rms current I.

V = 50 V (rms)f = 50 HzR = 10 ΩL = 50 mHC = 47 µF
I = A
14.AC impedance & phasorsHard
50 V500 HzR = 30 ΩL = 50 mHC = 4.7 µF+−VC​

A series RLC circuit is connected to a 50 V (rms), 500 Hz supply. Find the rms voltage VC across the capacitor.

V = 50 V (rms)f = 500 HzR = 30 ΩL = 50 mHC = 4.7 µF
VC = V
15.AC power & power factorMedium
120 VZ20 + j15 ΩI

A load with impedance Z = 20 + j15 Ω is connected to a 120 V (rms) single-phase supply. Find the real power P it absorbs.

V = 120 VZ = 20 + j15 Ω
P = W
16.AC power & power factorHard
P1​ = 92 kWQ1​S1​φ

A 200 kVA single-phase transformer supplies a load of 92 kW at a power factor of 0.8 lagging. How much extra real power ΔP can be added as a resistive (unity power factor) load before the transformer reaches its kVA rating?

Smax = 200 kVAP1 = 92 kWpf1 = 0.8
ΔP = kW
17.Three-phase powerMedium
ABCVL​ = 400 VIL​ = ?M15 kW, η = 94%cos φ = 0.88

A three-phase induction motor delivers 15 kW of mechanical output power at full load. At this load its efficiency is 94% and its power factor is 0.88 lagging. The supply has a line-to-line voltage of 400 V. Find the line current IL.

Pout = 15 kWη = 94%cos φ = 0.88VL = 400 V
IL = A
18.Three-phase powerHard
P = 75 kWφ1​S1​Q2​QC​

A balanced three-phase load takes 75 kW at a power factor of 0.7 lagging from a 400 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.9 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.

P = 75 kWpf1 = 0.7pf2 = 0.9VL = 400 Vf = 60 Hz
Cph = µF
19.TransformersMedium
RL​ = 12 Ω21460 VV2​I1​ = ?I2​

An ideal transformer with a turns ratio N₁:N₂ = 2:1 has 460 V applied to its primary winding. A 12 Ω resistor is connected across the secondary winding. Find the primary current I1.

N1:N2 = 2:1V1 = 460 VRL = 12 Ω
I1 = A
20.TransformersHard
250 kVA

A single-phase 250 kVA transformer has a core loss of 2000 W and a copper loss of 3000 W at rated load. At what load Sη,max, in kVA, is its efficiency highest?

S = 250 kVAPcore = 2000 WPcu,fl = 3000 W
Sη,max = kVA
21.Op-amp circuitsMedium
−+Vout​Rf​ = 100 kΩR1​ = 100 kΩVin​ = −0.2 V

The op-amp is ideal and runs from ±15 V supplies. Find the output voltage Vout.

Vin = −0.2 VR1 = 100 kΩRf = 100 kΩ
Vout = V
22.Op-amp circuitsHard
−+Vout​Rf​ = 1 kΩV1​ = 1.7 VR1​ = 1 kΩV2​ = 1.1 VR2​ = 100 kΩIf​

The summing amplifier uses an ideal op-amp with ±15 V supplies. Find the current If through the feedback resistor, flowing towards the output.

V1 = 1.7 VV2 = 1.1 VR1 = 1 kΩR2 = 100 kΩRf = 1 kΩ
If = mA
23.Diodes & transistorsMedium
RC​ = 1.5 kΩβ = 120RE​ = 470 ΩVCC​ = 15 VR1​ = 100 kΩR2​ = 22 kΩ

An NPN transistor with β = 120 has voltage-divider bias from VCC = 15 V: R₁ = 100 kΩ from VCC to the base and R₂ = 22 kΩ from the base to ground. The collector resistor is RC = 1.5 kΩ and the emitter resistor is RE = 470 Ω. Take VBE = 0.7 V and use the Thévenin equivalent of the divider (do not neglect the base current). Find the collector–emitter voltage VCE.

VCC = 15 VR1 = 100 kΩR2 = 22 kΩRC = 1.5 kΩRE = 470 Ωβ = 120
VCE = V
24.Diodes & transistorsHard
RC​ = 220 Ωβ = 100VCC​ = 12 V3.3 VRB​ = ?

An NPN transistor with β = 100 switches a 220 Ω load resistor connected between VCC = 12 V and its collector. The emitter is grounded. The base is driven from a 3.3 V logic output through a base resistor RB. Take VBE = 0.7 V and VCE(sat) = 0.2 V. For reliable switching, design for a base current 5 times the minimum needed for saturation. Find RB in kΩ.

VCC = 12 VRC = 220 Ωβ = 100Vin = 3.3 VVBE = 0.7 VVCE(sat) = 0.2 Voverdrive = 5
RB = kΩ
25.Number systemsMedium
place values in two's complement1−12816403211608140201

The 8-bit pattern 1101 0100 stores a signed integer in two's complement. What is its value N in decimal?

1101 01008 bit
N =
26.Number systemsHard
click the bits to set them012806403201608040201

Set the bits to the 8-bit result of 1110 1001 << 3. What is the result's value R in decimal?

1110 1001<< 3
R =
27.Digital logic: gates, K-maps & flip-flopsMedium
MUXCI0​C′I1​0I2​1I3​ABS1​S0​F

A 4-to-1 multiplexer has its select inputs S₁ = A and S₀ = B, and its data inputs tied to I₀ = C, I₁ = C′, I₂ = 0, I₃ = 1. For how many of the 8 combinations of A, B and C is the output F = 1? Find N.

I₀ = CI₁ = C′I₂ = 0I₃ = 1
N =
28.Digital logic: gates, K-maps & flip-flopsHard
ABCD000111100001111010X1X31214X5X70601211301511418X9011010

Find the minimal SOP form of F(A, B, C, D) = Σm(0, 2, 4, 8, 13, 14) + d(1, 3, 5, 7, 9), where d marks the don't-care conditions. How many product terms N does it have?

F(A, B, C, D) = Σm(0, 2, 4, 8, 13, 14) + d(1, 3, 5, 7, 9)
N =
29.Laplace transformsMedium
t (s)f(t)t = 1f(1) = ?

Find f(t) for F(s) = 25/(s(s + 1)(s + 2)) by partial fractions, and evaluate f(1).

F(s) = 25/(s(s + 1)(s + 2))t = 1 s
f(1) =
30.Laplace transformsHard
ReIm−2−4−6−8

A system is described by the differential equation y″ + 9y′ + 18y = 2u′ + 17u, with input u(t) and output y(t). Find its transfer function G(s) = Y(s)/U(s) (zero initial conditions) and evaluate the impulse response g(t) at t = 0.4 s. Find g(0.4).

y″ + 9y′ + 18y = 2u′ + 17ut = 0.4 s
g(0.4) =
31.Block diagramsMedium
R(s)+13K+6s + 2G(s)C(s)0.5H₁−−

The plant G(s) = 6/(s + 2) has an inner (minor) negative feedback loop with gain H₁ = 0.5. A controller gain K = 13 and an outer unity negative feedback loop close the system. Find the closed-loop pole p.

G(s) = 6/(s + 2)H₁ = 0.5K = 13
p =
32.Block diagramsHard
R(s)+12s + 1G₁+9s + 5G₂C(s)4H₁−0.5H₂−

Reduce the block diagram with G₁ = 12/(s + 1), G₂ = 9/(s + 5), an inner negative feedback H₁ = 4 around G₂ and an outer negative feedback H₂ = 0.5. Find the DC gain T(0) of C(s)/R(s).

G₁ = 12/(s + 1)G₂ = 9/(s + 5)H₁ = 4H₂ = 0.5
T(0) =
33.Step responseMedium
t (s)y(t)3ts​ = ?

A system has the transfer function G(s) = 147/(s² + 10s + 49) and receives a unit step input. Find the 2 % settling time ts of the step response, using ts ≈ 4/(ζωₙ).

G(s) = 147/(s² + 10s + 49)
ts = s
34.Step responseHard
R(s)+Ks(s + 2)G(s)C(s)−

A unity negative feedback loop has G(s) = K/(s(s + 2)). Find the gain K that gives a step response with 2 % overshoot.

G(s) = K/(s(s + 2))%OS = 2 %
K =
35.Bode plots & marginsMedium
|H| (dB)0.10.1111010100100−20020406080ω (rad/s)φ (°)ω (rad/s)−180−135−90−450ω = 8

Find the phase ∠G(jω) of G(s) = 47(s + 8)/(s(s + 1)) at ω = 8 rad/s, in degrees.

G(s) = 47(s + 8)/(s(s + 1))ω = 8 rad/s
∠G(jω) = °
36.Bode plots & marginsHard
|H| (dB)0.10.1111010100100−80−60−40−2002040ω (rad/s)φ (°)ω (rad/s)−270−180−900ω180​

A unity-feedback loop has the open-loop transfer function L(s) = K/(s(s + 2)(s + 5)). Find the gain K that gives a gain margin of 10 dB.

L(s) = K/(s(s + 2)(s + 5))GM = 10 dB
K =
37.Stability: Routh–Hurwitz & root locusMedium
R(s)+K1(s + 1)(s + 4)(s + 6)C(s)−

A unity-feedback loop has L(s) = K/((s + 1)(s + 4)(s + 6)), with K > 0. Find the largest gain Kmax for which the closed loop is stable.

L(s) = K/((s + 1)(s + 4)(s + 6))
Kmax =
38.Stability: Routh–Hurwitz & root locusHard
ReIm−2−4j2j4

The root locus of L(s) = K/((s + 1)(s + 2)(s + 4)) is sketched. Find the frequency ω at which the locus crosses the imaginary axis.

L(s) = K/((s + 1)(s + 2)(s + 4))
ω = rad/s
39.Steady-state error & PID controlMedium
r(t) = 3t+2s(s + 4)C(s)−

A ramp r(t) = 3t is applied to a unity-feedback loop with G(s) = 2/(s(s + 4)). Find the steady-state error ess.

G(s) = 2/(s(s + 4))r(t) = 3t
ess =
40.Steady-state error & PID controlHard
R(s)+K = 501s(s + 2)C(s)−

A proportional controller K = 50 drives the plant G(s) = 1/(s(s + 2)) in a unity-feedback loop. Find the percent overshoot %OS of the step response.

G(s) = 1/(s(s + 2))K = 50
%OS = %

3Solutions

1.Series & parallel resistors

Answer: IR2 = 0.766 A

Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.

R1​ = 3 ΩR3​ = 20 Ω+−V1​9 VR2​8 ΩAR4​12 ΩB

Combine resistors from the far end

Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.

R3 + R4 = 20 + 12 = 32 Ω
R2 ∥ 32 = 8·32/(8+32) = 6.4 Ω
Req = R1 + 6.4 = 3 + 6.4 = 9.4 Ω

Current from the source

The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.

IR1 = V1/Req = 9/9.4 = 0.9574 A

Current through R₂

Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.

VA = V1 − IR1·R1 = 9 − 0.9574·3 = 6.128 V
IR2 = VA/R2 = 6.128/8 = 0.766 A

Answer

IR2 = 0.766 A
2.Series & parallel resistors

Answer: IR1 = 0.6895 A

Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.

R1​ = 20 ΩR3​ = 3 ΩR5​ = 8 Ω+−V1​15 VR2​2 ΩAR4​30 ΩBR6​10 Ω

Combine resistors from the far end

Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.

R5 + R6 = 8 + 10 = 18 Ω
R4 ∥ 18 = 11.25 Ω
R3 + 11.25 = 14.25 Ω
R2 ∥ 14.25 = 1.754 Ω
Req = R1 + 1.754 = 20 + 1.754 = 21.75 Ω

Current from the source

The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.

IR1 = V1/Req = 15/21.75 = 0.6895 A

Answer

IR1 = 0.6895 A
3.Nodal analysis

Answer: I2 = 2.923 A

Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.

KCL at node A

Take the bottom wire as ground. Each branch carries (VA − Vk)/Rk away from A, where Vk is the voltage of its source (zero for a plain resistor). The currents leaving A add up to zero.

(VA − (−30))/8 + (VA − 12)/3 + (VA − 18)/12 = 0

Solve for VA

VA = ((−30)/8 + 12/3 + 18/12) / (1/8 + 1/3 + 1/12) = 1.75/0.5417 = 3.231 V

Branch current

The arrow points up through the branch, into node A.

I2 = (12 − VA)/R2 = (12 − 3.231)/3 = 2.923 A

Answer

I2 = 2.923 A

A negative result means the real current flows against the arrow.

4.Nodal analysis

Answer: IR4 = −2.779 A

Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.

R1​ = 8 ΩR2​ = 30 ΩR4​ = 4 Ω+−V1​24 VR3​4 ΩAR5​12 ΩBIs​6 A−+V2​15 V

Set up the nodes

Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 24 V, V2 = −15 V). Unknowns: VA, VB.

KCL at node A

Currents leaving A through the resistors equal the current pushed into A by sources.

VA/R3 + (VA − V1)/R1 + (VA − VB)/R2 = 0
VA/4 + (VA − 24)/8 + (VA − VB)/30 = 0
0.4083·VA − 0.03333·VB = 3

KCL at node B

Currents leaving B through the resistors equal the current pushed into B by sources.

VB/R5 + (VB − VA)/R2 + (VB − V2)/R4 = Is
VB/12 + (VB − VA)/30 + (VB − (−15))/4 = (−6)
−0.03333·VA + 0.3667·VB = −9.75

Solve

Δ = (0.4083)(0.3667) − (−0.03333)(−0.03333) = 0.1486
VA = Δ1/Δ = 0.775/0.1486 = 5.215 V
VB = Δ2/Δ = −3.881/0.1486 = −26.12 V

Answer

IR4 = (VB − V2)/R4 = (−26.12 − −15)/4 = −2.779 A
5.Mesh analysis

Answer: VR2 = −3 V

Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.

R1​ = 4 ΩR2​ = 4 Ω+−V1​9 VR3​4 ΩA+−V2​9 VI1​I2​

Assign mesh currents

Draw a clockwise current in each window: I1, I2. A resistor shared by two meshes carries the difference of their currents.

KVL around mesh 1

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R1·I1 + R3(I1 − I2) = V1
4·I1 + 4(I1 − I2) = 9
8·I1 − 4·I2 = 9

KVL around mesh 2

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R2·I2 + R3(I2 − I1) = −V2
4·I2 + 4(I2 − I1) = (−9)
−4·I1 + 8·I2 = −9

Solve

Δ = (8)(8) − (−4)(−4) = 48
I1 = Δ1/Δ = 36/48 = 0.75 A
I2 = Δ2/Δ = −36/48 = −0.75 A

Answer

IR2 = I2 = −0.75 A
VR2 = IR2·R2 = −0.75·4 = −3 V

A negative mesh current flows anticlockwise.

6.Mesh analysis

Answer: I2 = 0.1269 A

Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.

R1​ = 5 ΩR2​ = 30 ΩR3​ = 6 Ω+−V1​15 VR4​30 ΩAR5​12 ΩB+−V2​12 VI1​I2​I3​

Assign mesh currents

Draw a clockwise current in each window: I1, I2, I3. A resistor shared by two meshes carries the difference of their currents.

KVL around mesh 1

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R1·I1 + R4(I1 − I2) = V1
5·I1 + 30(I1 − I2) = 15
35·I1 − 30·I2 = 15

KVL around mesh 2

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R2·I2 + R4(I2 − I1) + R5(I2 − I3) = 0
30·I2 + 30(I2 − I1) + 12(I2 − I3) = 0
−30·I1 + 72·I2 − 12·I3 = 0

KVL around mesh 3

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R3·I3 + R5(I3 − I2) = −V2
6·I3 + 12(I3 − I2) = (−12)
−12·I2 + 18·I3 = −12

Solve

Δ = det of the coefficient matrix = 24120
I1 = Δ1/Δ = 12960/24120 = 0.5373 A
I2 = Δ2/Δ = 3060/24120 = 0.1269 A
I3 = Δ3/Δ = −14040/24120 = −0.5821 A

Answer

I2 = 0.1269 A

A negative mesh current flows anticlockwise.

7.Superposition

Answer: IR2 = 0.4694 A

Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.

R1​ = 15 ΩR3​ = 15 Ω+−V1​18 VR2​20 ΩAR4​3 ΩBOPEN

Case 1 · V1 acting alone

Iₛ becomes an open circuit, so R₃ and R₄ form one series branch from A to ground, in parallel with R₂.

R3+R4 = 15+3 = 18 Ω
R2 ∥ (R3+R4) = 20·18/(20+18) = 9.474 Ω
VA = 18·9.474/(15+9.474) = 6.968 V
VB = VA·R4/(R3+R4) = 6.968·3/18 = 1.161 V
IR2′ = (VA − 0)/R2 = (6.968 − 0)/20 = 0.3484 A
R1​ = 15 ΩR3​ = 15 ΩSHORTR2​20 ΩAR4​3 ΩBIs​2.5 A

Case 2 · Is acting alone

V₁ becomes a short, so R₁ is in parallel with R₂. Iₛ splits at B between R₄ and the path through R₃.

R1 ∥ R2 = 15·20/(15+20) = 8.571 Ω
Req = R4 ∥ (R3+R1∥R2) = 3 ∥ 23.57 = 2.661 Ω
VB = Is·Req = 2.5·2.661 = 6.653 V
VA = VB·(R1∥R2)/(R3+R1∥R2) = 6.653·8.571/23.57 = 2.419 V
IR2″ = (VA − 0)/R2 = (2.419 − 0)/20 = 0.121 A

Add the contributions

IR2 = IR2′ + IR2″
IR2 = 0.3484 + 0.121 = 0.4694 A

A negative result means the real current flows against the arrow.

8.Superposition

Answer: V2 = 16 V

Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.

R1​ = 15 ΩR2​ = 2 ΩR4​ = 5 Ω+−V1​30 VR3​20 ΩAOPENBSHORT

Case 1 · V1 acting alone

V₂ becomes a short and Iₛ an open circuit. Seen from A, R₃ is in parallel with the series pair R₂+R₄.

R3 ∥ (R2+R4) = 20 ∥ 7 = 5.185 Ω
VA = 30·5.185/(15+5.185) = 7.706 V
VB = VA·R4/(R2+R4) = 7.706·5/7 = 5.505 V
R1​ = 15 ΩR2​ = 2 ΩR4​ = 5 ΩSHORTR3​20 ΩAIs​6 ABSHORT

Case 2 · Is acting alone

Both voltage sources become shorts. Iₛ splits at B between R₄ (now to ground) and R₂ in series with R₁ ∥ R₃. The arrow of Iₛ points down, away from its node, so Iₛ draws current out of that node: its term enters with a minus sign.

R1 ∥ R3 = 8.571 Ω, so the left path is R2+8.571 = 10.57 Ω
Req = R4 ∥ 10.57 = 3.394 Ω
VB = −Is·Req = −6·3.394 = −20.37 V
VA = VB·8.571/10.57 = −16.51 V

Case 3 · V2 acting alone, per volt

V₁ becomes a short and Iₛ an open circuit. R₁ ∥ R₃ hangs from A, in series with R₂ back to B.

R1 ∥ R3 = 8.571 Ω
VA‴ = V2·8.571/(5 + 2 + 8.571) = 0.5505·V2

Set VA to zero

With VA = 0 there is no voltage across R₃, so its current is zero.

VA′ + VA″ + VA‴ = 7.706 + (−16.51) + 0.5505·V2 = 0
V2 = 8.807/0.5505 = 16 V

Answer

V2 = 16 V
9.Thévenin & Norton

Answer: IL = 0.5769 A

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 10 ΩR3​ = 6 ΩSHORTR2​5 ΩAabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 10·5/(10+5) = 3.333 Ω
Rth = (R1 ∥ R2) + R3 = 3.333 + 6 = 9.333 Ω
R1​ = 10 ΩR3​ = 6 Ω+−V1​30 VR2​5 ΩAab+−Vth​

Find Vth, the open-circuit voltage

With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.

Vth = V1·R2/(R1+R2) = 30·5/(10+5) = 10 V
Rth​ = 9.333 Ω+−Vth​10 VRL​8 ΩIL​

Connect the load to the Thévenin equivalent

The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.

IL = Vth/(Rth + RL) = 10/(9.333 + 8) = 0.5769 A
10.Thévenin & Norton

Answer: Vth = 39.67 V

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 2 ΩR3​ = 5 ΩSHORTR2​4 ΩAOPENBabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 2·4/(2+4) = 1.333 Ω
Rth = (R1 ∥ R2) + R3 = 1.333 + 5 = 6.333 Ω
R1​ = 2 ΩR3​ = 5 Ω+−V1​12 VR2​4 ΩAIs​5 ABab+−Vth​

Find Vth, the open-circuit voltage

With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.

VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 8 + 5·1.333 = 14.67 V
Vth = VB = VA + Is·R3 = 14.67 + 5·5 = 39.67 V
11.RC & RL transients

Answer: vL = 0.7147 V

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Time constant and final current

Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.

τ = L/R = 47 mH / 100 Ω = 0.47 ms
i(∞) = Vs/R = 6/100 = 0.06 A

Inductor voltage

At t = 0 the whole supply voltage appears across the inductor; it then decays to zero.

vL(t) = Vs·e−t/τ = 6·e−1/0.47 = 0.7147 V

Answer

vL = 0.7147 V
12.RC & RL transients

Answer: i = 0.1992 A

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Initial value, final value, time constant

Before t = 0 the closed switch bypasses R₂; afterwards R₁ and R₂ are both in the loop.

i(0) = 15/47 = 0.3191 A
i(∞) = 15/(47 + 33) = 0.1875 A
τ = L/R = 33/80 = 0.4125 ms
i(t) = 0.1875 + (0.3191 − 0.1875)·e−t/τ

Current at the given time

i(1) = 0.1875 + (0.1316)·e−1/0.4125 = 0.1992 A

Answer

i = 0.1992 A
13.AC impedance & phasors

Answer: I = 0.9439 A

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactances

ω = 2πf = 2π·50 = 314.2 rad/s
XL = ωL = 314.2·0.05 = 15.71 Ω
XC = 1/(ωC) = 1/(314.2·47·10⁻⁶) = 67.73 Ω

Impedance

In series the impedances add as complex numbers: Z = R + j(XL − XC).

|Z| = √(R² + (XL − XC)²) = √(10² + (−52.02)²) = 52.97 Ω

Current

The same current flows through every element of a series circuit.

I = V/|Z| = 50/52.97 = 0.9439 A

Answer

I = 0.9439 A
14.AC impedance & phasors

Answer: VC = 35.93 V

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactances

ω = 2πf = 2π·500 = 3142 rad/s
XL = ωL = 3142·0.05 = 157.1 Ω
XC = 1/(ωC) = 1/(3142·4.7·10⁻⁶) = 67.73 Ω

Impedance

In series the impedances add as complex numbers: Z = R + j(XL − XC).

|Z| = √(R² + (XL − XC)²) = √(30² + (89.35)²) = 94.26 Ω

Current

The same current flows through every element of a series circuit.

I = V/|Z| = 50/94.26 = 0.5305 A

Voltage across the capacitor

VC = I·XC = 0.5305·67.73 = 35.93 V

Answer

VC = 35.93 V
15.AC power & power factor

Answer: P = 460.8 W

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Current

|Z| = √(20² + 15²) = 25 Ω
I = V/|Z| = 120/25 = 4.8 A

Real power

P = I²·R = 4.8²·20 = 460.8 W

Answer

P = 460.8 W
16.AC power & power factor

Answer: ΔP = 95.72 kW

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Reactive power of the existing load

Q1 = 92·tan(arccos 0.8) = 69 kvar

Largest total real power

At full rating S = Smax, and Q is unchanged by the resistive load.

P = √(Smax² − Q1²) = √(200² − 69²) = 187.7 kW

Extra real power

ΔP = 187.7 − 92 = 95.72 kW

Answer

ΔP = 95.72 kW
17.Three-phase power

Answer: IL = 26.17 A

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.

Electrical input power

Pin = Pout/η = 15/0.94 = 15.96 kW

Line current

IL = Pin/(√3·VL·cos φ) = 15957/(√3·400·0.88) = 26.17 A

Answer

IL = 26.17 A
18.Three-phase power

Answer: Cph = 222.1 µF

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.

Reactive power before and after

The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.

Q1 = 75·tan(acos 0.7) = 75·1.02 = 76.52 kvar
Q2 = 75·tan(acos 0.9) = 75·0.4843 = 36.32 kvar

Reactive power from the capacitors

QC = Q1 − Q2 = 40.19 kvar

Capacitance per phase

In a Δ bank each capacitor is connected between two lines.

V = 400 V, ω = 2π·60 = 377 rad/s
Cph = (QC/3)/(ω·V²) = 13397/(377·400²) = 222.1 µF

Answer

Cph = 222.1 µF
19.Transformers

Answer: I1 = 9.583 A

Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.

Secondary voltage and current

V2 = 460/2 = 230 V
I2 = 230/12 = 19.17 A

Primary current

An ideal transformer has no losses: V₁·I₁ = V₂·I₂.

I1 = I2/2 = 9.583 A

Answer

I1 = 9.583 A

Check: the load seen from the primary is a²·RL = 48 Ω, and 460/48 gives the same current.

20.Transformers

Answer: Sη,max = 204.1 kVA

Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.

Copper loss equals core loss

x²·3000 = 2000 → x = √(2000/3000) = 0.8165

Load at maximum efficiency

Sη,max = x·S = 0.8165·250 = 204.1 kVA

Answer

Sη,max = 204.1 kVA
21.Op-amp circuits

Answer: Vout = −0.4 V

Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.

Inverting input follows the input

V₋ = V₊ = −0.2 V
I = V₋/R1 = −0.2/100 = −0.002 mA

Output voltage

The current through R₁ also flows through Rf.

Vout = V₋ + I·Rf = −0.2 + (−0.002)·100 = −0.4 V

Answer

Vout = −0.4 V
22.Op-amp circuits

Answer: If = 1.711 mA

Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.

Input currents

V₋ = 0, so each input resistor has its full input voltage across it.

I1 = V1/R1 = 1.7/1 = 1.7 mA
I2 = V2/R2 = 1.1/100 = 0.011 mA
If = I1 + I2 = 1.711 mA

Answer

If = 1.711 mA
23.Diodes & transistors

Answer: VCE = 8.66 V

BJT bias point: in the active region VBE = 0.7 V, IC = β·IB and IE = (β + 1)·IB. Find IB from the base loop with KVL, then IC, then VCE from the collector–emitter loop. A voltage divider at the base is replaced by its Thévenin equivalent VTH = VCC·R₂/(R₁ + R₂), RTH = R₁∥R₂; an emitter resistor appears (β + 1) times larger in the base loop.

Thévenin equivalent of the divider

VTH = 15·22/(100 + 22) = 2.705 V
RTH = 100·22/(100 + 22) = 18.03 kΩ

Base current

KVL around the base loop; the emitter current is (β + 1)·IB.

IB = (2.705 − 0.7)/(18.03 + 121·0.47) = 26.77 µA

Collector current

IC = 120·26.77 µA = 3.212 mA
IE = 121·26.77 µA = 3.239 mA

Collector–emitter voltage

VCE = 15 − 3.212·1.5 − 3.239·0.47 = 8.66 V

Answer

VCE = 8.66 V
24.Diodes & transistors

Answer: RB = 0.9695 kΩ

BJT as a switch: to switch a load fully on, the transistor is driven into saturation, where VCE = VCE(sat) and the collector current is set by the load: IC(sat) = (VCC − VCE(sat))/RC. Saturation needs at least IB = IC(sat)/β. If the base current is smaller, the transistor stays active and IC = β·IB.

Collector current in saturation

IC(sat) = (12 − 0.2)/220 = 53.64 mA

Minimum base current

IB(min) = IC(sat)/β = 53.64/100 = 536.4 µA

Design base current

IB = 5·536.4 µA = 2682 µA

Base resistor

RB = (3.3 − 0.7)/IB = 2.6 V/2.682 mA = 0.9695 kΩ

Answer

RB = 0.9695 kΩ
25.Number systems

Answer: N = −44

Positional number systems: each digit is worth its value times a power of the base. In binary the places are worth 1, 2, 4, 8, 16, …; in hexadecimal 1, 16, 256, …, with A–F standing for 10–15. In 8-bit two's complement the leftmost bit is worth −128 instead of +128, which is how negative numbers are stored.

Add the place values

The other bits keep their normal positive values.

−128 + 64 + 16 + 4 = −44

Answer

N = −44
26.Number systems

Answer: R = 72

Setting bits: each bit is worth a power of two (128, 64, …, 1). One hex digit is exactly four bits, and in 8-bit two's complement the leftmost bit is worth −128. Bitwise operations work on each bit position separately.

Bit by bit

Shifting left by 3 moves every bit 3 places to the left; bits that fall off the left end are lost and zeros come in on the right.

1110 1001 << 3
= 0100 1000

Value of the result

0100 1000₂ = 72

Answer

R = 72
27.Digital logic: gates, K-maps & flip-flops

Answer: N = 4

Multiplexer: a 2ⁿ-to-1 multiplexer passes one of its data inputs to the output; the select lines, read as a binary number, pick which one. For a 4-to-1 MUX with selects S₁S₀ = AB, F = A′B′·I₀ + A′B·I₁ + AB′·I₂ + AB·I₃. Tying the data inputs to 0, 1, C or C′ makes the MUX produce any function of A, B and C, which is a common way to build logic with one chip.

Output expression

F = A′B′C + A′BC′ + AB

Rows with F = 1

ABC = 001, 010, 110, 111
N = 4

Answer

N = 4
28.Digital logic: gates, K-maps & flip-flops

Answer: N = 5

Karnaugh maps: the cells are ordered in Gray code (00, 01, 11, 10), so neighbouring cells, including the ones across the edges, differ in exactly one variable. Group the 1s in rectangles of 1, 2, 4, 8 or 16 cells, as large as possible and as few as possible, until every 1 is covered. Each group is one product term: the variables that stay constant inside it. A group of 2ᵏ cells loses k variables. Don't-cares (X) may be used to make groups bigger but never have to be covered. Grouping the 0s instead gives the minimal POS form.

Prime implicants

The largest groups that can be formed from 1s and Xs.

C′D, B′C′, A′C′, A′B′, ABCD′
ABCD000111100001111010X1X31214X5X70601211301511418X9011010

Minimal cover

F = C′D + B′C′ + A′C′ + A′B′ + ABCD′
N = 5

Answer

N = 5
29.Laplace transforms

Answer: f(1) = 4.995

Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).

Partial fractions

F(s) = A/s + B/(s + 1) + C/(s + 2)
A = 25/(1·2) = 12.5
B = 25/((−1)·1) = −25
C = 25/((−2)·(−1)) = 12.5

Inverse transform

f(t) = 12.5 − 25·e−t + 12.5·e−2t

Evaluate

f(1) = 12.5 − 25·e−1 + 12.5·e−2·1 = 4.995

Answer

f(1) = 4.995
30.Laplace transforms

Answer: g(0.4) = 0.9532

Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).

Transfer function

G(s) = Y(s)/U(s) = (2s + 17)/(s² + 9s + 18)

Partial fractions

s² + 9s + 18 = (s + 3)(s + 6)
A = 3.667, B = −1.667

Impulse response

g(t) = 3.667·e−3t − 1.667·e−6t
g(0.4) = 0.9532

Answer

g(0.4) = 0.9532
31.Block diagrams

Answer: p = −83

Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).

Inner loop

Gᵢ = G/(1 + G·H₁) = 6/(s + 2 + 6·0.5) = 6/(s + 5)

Outer loop

T(s) = K·Gᵢ/(1 + K·Gᵢ) = 78/(s + 5 + 78) = 78/(s + 83)

Result

p = −83

Answer

p = −83
32.Block diagrams

Answer: T(0) = 1.137

Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).

Inner loop

Gᵢ = G₂/(1 + G₂H₁) = 9/(s + 41)

Outer loop

T(s) = G₁Gᵢ/(1 + G₁GᵢH₂) = 108/((s + 1)(s + 41) + 54)

DC gain

T(0) = 108/(1·41 + 54) = 108/95 = 1.137

Answer

T(0) = 1.137
33.Step response

Answer: ts = 0.8 s

Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).

Compare with the standard form

The denominator must match s² + 2ζωₙs + ωₙ².

ωₙ² = 49 → ωₙ = 7 rad/s
2ζωₙ = 10 → ζ = 10/(2·7) = 0.7143

Result

ζωₙ = 5 → ts ≈ 4/5 = 0.8 s

Answer

ts = 0.8 s
34.Step response

Answer: K = 1.645

Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).

Closed-loop transfer function

T(s) = K/(s² + 2s + K)

Damping ratio from the overshoot

ζ = −ln(0.02)/√(π² + ln²(0.02)) = 0.7797

Gain

ωₙ = 2/(2ζ) = 1.283 rad/s
K = ωₙ² = 1.645

Answer

K = 1.645
35.Bode plots & margins

Answer: ∠G(jω) = −127.9 °

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Add the angles

∠G = atan(8/8) − 90° − atan(8/1) = 45° − 90° − 82.87°

Result

∠G(j8) = −127.9°

Answer

∠G(jω) = −127.9°
36.Bode plots & margins

Answer: K = 22.14

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Phase crossover

(ω/2)·(ω/5) = 1 → ω180 = √(2·5) = 3.162 rad/s

Magnitude at phase crossover

|L(jω180)| = K/(ω·√(ω² + 4)·√(ω² + 25)) = K/(2·5·(2 + 5)) = K/70

Required gain

70/K = 1010/20 = 3.162
K = 70/3.162 = 22.14

Answer

K = 22.14
37.Stability: Routh–Hurwitz & root locus

Answer: Kmax = 350

Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.

Characteristic polynomial

s³ + 11s² + 34s + 24 + K = 0

Routh array

s³: 1, 34
s²: 11, 24 + K
s¹: (11·34 − 24 − K)/11
s⁰: 24 + K

Condition

The s¹ entry must stay positive.

K < 11·34 − 24 = 350

Answer

Kmax = 350

At the limit the loop oscillates at ω = √34 = 5.831 rad/s.

38.Stability: Routh–Hurwitz & root locus

Answer: ω = 3.742 rad/s

Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.

Critical gain

s³ + 7s² + 14s + 8 + K = 0
s¹: (7·14 − 8 − K)/7 = 0 → K = 90

Crossing frequency

7s² + 8 + 90 = 7s² + 98 = 0 → s² = −14
ω = √14 = 3.742 rad/s

Answer

ω = 3.742 rad/s
39.Steady-state error & PID control

Answer: ess = 6

Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.

Velocity constant

Kv = lim s·G(s) = 0.5

Ramp error

ess = 3/0.5 = 6

Answer

ess = 6
40.Steady-state error & PID control

Answer: %OS = 63.84 %

P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).

Characteristic polynomial

s(s + 2) + 50·1 = s² + 2s + 50

ωₙ and ζ

ωₙ = √50 = 7.071 rad/s
ζ = 2/(2·7.071) = 0.1414

Overshoot

%OS = 100·e−0.1414π/√(1 − 0.1414²) = 63.84 %

Answer

%OS = 63.84 %

This is independent practice material. ExamProblems is not affiliated with or endorsed by the organisation that runs this exam, and the exam name is used only to describe the content. The FE exam is run by NCEES, which is not affiliated with ExamProblems and does not endorse it.

ExamProblems · examproblems.com/courses/fe-exam-electrical