FE Electrical and Computer exam practice: cram pack

Formula sheets, the key method steps for every topic and 40 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

Series & parallel resistors

Resistors in series
Req = R1 + R2 + …
Resistors in parallel
1/Req = 1/R1 + 1/R2 + …
Two in parallel
Req = R1R2 / (R1 + R2)
Ohm's law
V = I·R
Power
P = V·I = I²R = V²/R

Method

  1. Start at the end of the network furthest from the terminals.
  2. Combine resistors in series by adding them, and resistors in parallel with 1/R = 1/R₁ + 1/R₂ + …
  3. Redraw the circuit after each step.
  4. Repeat until one resistor is left between the terminals.

Nodal analysis

Kirchhoff’s current law
ΣIin = ΣIout
Branch current
I = (Va − Vb)/R
Reference node
Vground = 0

Method

  1. Choose a reference node (ground) and label the other node voltages.
  2. Write Kirchhoff’s current law at every unknown node: currents leaving through each branch equal the currents entering.
  3. Express every branch current as (Va − Vb)/R.
  4. Solve the system of equations, then find any current you need.

Mesh analysis

Kirchhoff’s voltage law
ΣV = 0 around every loop
Shared resistor
current = I1 − I2
Current source in a mesh
fixes that mesh current

Method

  1. Draw a clockwise current in every mesh (window) of the circuit.
  2. Apply Kirchhoff’s voltage law around each mesh: the sum of voltage drops is zero.
  3. In a resistor shared by two meshes the current is the difference of the two mesh currents.
  4. Solve the equations; a negative result means the current flows the other way.

Superposition

Superposition
x = x1 + x2 + … (one source at a time)
Switched-off voltage source
short circuit (0 V)
Switched-off current source
open circuit (0 A)
Voltage divider
V2 = V·R2/(R1 + R2)
Current divider
I1 = I·R2/(R1 + R2)

Method

  1. Count the independent sources. You will solve one simpler circuit per source.
  2. Keep one source and switch off the others: a voltage source becomes a short circuit (a wire), a current source becomes an open circuit (a gap).
  3. Solve the simpler circuit for the voltage or current you need, keeping track of its direction.
  4. Repeat for every source, then add the contributions with their signs.

Thévenin & Norton

Thévenin voltage
Vth = Vopen circuit
Thévenin resistance
Rth: all sources off, seen from a–b
Norton current
IN = Vth/Rth
Load current
IL = Vth/(Rth + RL)
Maximum power transfer
RL = Rth, Pmax = Vth²/(4Rth)

Method

  1. Remove the load and mark the two terminals a and b.
  2. Find the open-circuit voltage between a and b: this is Vth.
  3. Switch off all independent sources and find the resistance seen from a–b: this is Rth.
  4. Put the load back on the equivalent circuit: Vth in series with Rth.
  5. For the Norton equivalent, convert: IN = Vth/Rth, with RN = Rth in parallel.

RC & RL transients

Time constant
τ = RC | τ = L/R
Response
x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ
Capacitor at DC
open circuit; vC cannot jump
Inductor at DC
short circuit; iL cannot jump
Settled
t ≈ 5τ

Method

  1. Find the initial value just after switching: a capacitor voltage and an inductor current cannot jump.
  2. Find the final value long after switching: a capacitor acts as an open circuit, an inductor as a short circuit.
  3. Find the time constant: τ = RC or τ = L/R, using the resistance seen by the capacitor or inductor.
  4. Use x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ.

AC impedance & phasors

Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z

Method

  1. Convert the frequency: ω = 2πf.
  2. Find each reactance: XL = ωL and XC = 1/(ωC).
  3. Add impedances like resistors, with Z = R + jX.
  4. Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.

AC power & power factor

Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)

Three-phase power

Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η

Transformers

Turns ratio
a = N1/N2 = V1/V2
Current ratio
I1/I2 = N2/N1 = 1/a
Rated current
I = S/V
Referred impedance
Z1′ = a²·ZL
Copper loss at part load
Pcu = x²·Pcu,fl
Efficiency
η = x·S·pf/(x·S·pf + Pcore + x²·Pcu,fl)
Maximum efficiency
x = √(Pcore/Pcu,fl)

Op-amp circuits

Inverting amplifier
Vout = −(Rf/Rin)·Vin
Non-inverting amplifier
Vout = (1 + Rf/R1)·Vin
Summing amplifier
Vout = −Rf(V1/R1 + V2/R2)
Ideal op-amp
V+ = V−, Iin = 0

Diodes & transistors

Diode (constant drop)
VD = 0.7 V when conducting
Active region
VBE = 0.7 V, IC = β·IB, IE = (β + 1)·IB
Fixed bias
IB = (VCC − 0.7)/RB
Divider bias
IB = (VTH − 0.7)/(RTH + (β + 1)RE)
Thévenin of the divider
VTH = VCC·R2/(R1 + R2), RTH = R1∥R2
Collector loop
VCE = VCC − ICRC − IERE
Saturation
IC(sat) = (VCC − VCE(sat))/RC, IB ≥ IC(sat)/β

Number systems

Place values
binary 2k, octal 8k, hex 16k
To decimal
Σ dk·bk
From decimal
divide by the base, read the remainders bottom-up
Hex ↔ binary
one hex digit = 4 bits
Two’s complement
invert the bits and add 1

Digital logic: gates, K-maps & flip-flops

Basic gates
A·B, A + B, A′, (A·B)′, (A + B)′, A ⊕ B
Boolean rules
X + X′ = 1, X·X′ = 0, X + XY = X, XY + XY′ = X
De Morgan
(X·Y)′ = X′ + Y′, (X + Y)′ = X′·Y′
Karnaugh map order
00, 01, 11, 10 (Gray code)
Group of 2ᵏ cells
loses k variables
4-to-1 multiplexer
F = A′B′I0 + A′BI1 + AB′I2 + ABI3
Flip-flops
D: Q⁺ = D, T: Q⁺ = T ⊕ Q, JK: Q⁺ = JQ′ + K′Q
Counters
n-bit: 2ⁿ states; mod-N: smallest n with 2ⁿ ≥ N; fout = fclk/N
Ripple counter
fmax = 1/(n·tpd)
Ring and Johnson counters
n and 2n states

Method

  1. For a circuit, work from the inputs to the output one gate at a time and write the value on every wire, or write its expression and fill in the truth table.
  2. For simplification, put the 1s (and the don’t-cares as X) into a Karnaugh map with Gray-code rows and columns: 00, 01, 11, 10.
  3. Cover the 1s with as few and as large groups of 1, 2, 4, 8 or 16 cells as possible, wrapping round the edges; each group is one product term made of the variables that stay constant. Group the 0s for the POS form.
  4. For flip-flops and counters, read the inputs at each active clock edge, write the state after every edge, and remember that an n-bit counter wraps round after 2ⁿ states.

Stability: Routh–Hurwitz & root locus

Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)

Method

  1. Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
  2. Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
  3. Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
  4. For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.

Steady-state error & PID control

System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)

Method

  1. Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
  2. Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
  3. Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
  4. For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².

2Practice problems

1.Series & parallel resistorsMedium
R1​ = 4 ΩR3​ = 8 Ω+−V1​10 VR2​5 ΩIR2​AR4​5 ΩB

Find the current IR2 through R2.

V1 = 10 VR1 = 4 ΩR2 = 5 ΩR3 = 8 ΩR4 = 5 Ω
IR2 = A
2.Series & parallel resistorsHard
R1​ = 12 ΩR3​ = 5 ΩR5​ = 30 Ω+−V1​15 VR2​30 ΩIR2​AR4​5 ΩBR6​12 Ω

Find the current IR2 through R2.

V1 = 15 VR1 = 12 ΩR2 = 30 ΩR3 = 5 ΩR4 = 5 ΩR5 = 30 ΩR6 = 12 Ω
IR2 = A
3.Nodal analysisMedium
R1​ = 3 ΩR3​ = 3 Ω+−V1​30 VR2​20 ΩAR4​6 ΩBIs​5 A

Use nodal analysis to find the power PIs delivered by the current source Is.

V1 = 30 VIs = 5 AR1 = 3 ΩR2 = 20 ΩR3 = 3 ΩR4 = 6 Ω
PIs = W
4.Nodal analysisHard
R1​ = 6 ΩIR1​−+Vs​ = 8 V+−V1​12 VR2​3 ΩAR3​5 ΩBIs​2.5 A

The voltage source Vₛ between A and B has its + terminal at B, so it makes VB − VA = Vₛ. Use nodal analysis with a supernode to find the current IR1 through R1 in the direction of the arrow.

V1 = 12 VIs = 2.5 AVs = 8 VR1 = 6 ΩR2 = 3 ΩR3 = 5 Ω
IR1 = A
5.Mesh analysisMedium
R1​ = 6 ΩIR1​R2​ = 15 Ω+−V1​9 VR3​12 ΩA+−V2​24 VI1​I2​

Use mesh analysis to find the current IR1 through R1 in the direction of the arrow.

V1 = 9 VV2 = 24 VR1 = 6 ΩR2 = 15 ΩR3 = 12 Ω
IR1 = A
6.Mesh analysisHard
R1​ = 2 ΩR2​ = 2 Ω+−VR2​R3​ = 8 Ω+−V1​18 VR4​4 ΩAR5​12 ΩB+−V2​9 VI1​I2​I3​

Use mesh analysis to find the voltage VR2 across R2 with the polarity shown.

V1 = 18 VV2 = 9 VR1 = 2 ΩR2 = 2 ΩR3 = 8 ΩR4 = 4 ΩR5 = 12 Ω
VR2 = V
7.SuperpositionMedium
R1​ = 4 ΩR3​ = 2 Ω+−V1​24 VR2​4 ΩIR2​AR4​5 ΩBIs​1 A

Use superposition to find the current IR2 through R2 in the direction of the arrow.

V1 = 24 VIs = 1 AR1 = 4 ΩR2 = 4 ΩR3 = 2 ΩR4 = 5 Ω
IR2 = A
8.SuperpositionHard
R1​ = 25 ΩR2​ = 3 ΩR4​ = 8 Ω+−V1​15 VR3​3 ΩIR3​AIs​6 AB+−V2​?

Find the value of the voltage source V2 (polarity as shown) that makes the current IR3 through R3 equal to zero.

V1 = 15 VIs = 6 AR1 = 25 ΩR2 = 3 ΩR3 = 3 ΩR4 = 8 Ω
V2 = V
9.Thévenin & NortonMedium
R1​ = 10 ΩR3​ = 4 Ω+−V1​15 VR2​4 ΩAab

Find the Norton current IN: the current that flows from a to b if the terminals are shorted.

V1 = 15 VR1 = 10 ΩR2 = 4 ΩR3 = 4 Ω
IN = A
10.Thévenin & NortonHard
R1​ = 6 ΩR3​ = 8 Ω+−V1​9 VR2​6 ΩAIs​4 ABab

Find the Norton current IN: the current that flows from a to b if the terminals are shorted.

V1 = 9 VIs = 4 AR1 = 6 ΩR2 = 6 ΩR3 = 8 Ω
IN = A
11.RC & RL transientsMedium
+−Vs​10 Vt = 0R = 5 ΩL220 mHi(t)

The inductor carries no current before the switch closes at t = 0. Find the energy W(∞) stored in the inductor once the circuit has settled, in mJ.

Vs = 10 VR = 5 ΩL = 220 mH
W(∞) = mJ
12.RC & RL transientsHard
+−Vs​24 Vt = 0R = 6.8 kΩC22 µF+−vC​vC​(0) = 12 V

Just before the switch closes at t = 0, the capacitor holds 12 V with the polarity shown. Find the capacitor voltage vC at t = 60 ms.

Vs = 24 VR = 6.8 kΩC = 22 µFvC(0) = 12 Vt = 60 ms
vC = V
13.AC impedance & phasorsMedium
Vf0​ = 60 HzRL = ?C = 47 µF

A series RLC circuit with C = 47 µF must resonate at 60 Hz. Find the inductance L needed.

f0 = 60 HzC = 47 µF
L = mH
14.AC impedance & phasorsHard
50 V200 HzR1​ = 30 ΩR2​ = 30 ΩC = 47 µF

A resistor R1 is connected in series with a parallel combination of R2 and a capacitor C, across a 50 V (rms), 200 Hz supply. Find the magnitude of the impedance |Z|.

V = 50 V (rms)f = 200 HzR1 = 30 ΩR2 = 30 ΩC = 47 µF
|Z| = Ω
15.AC power & power factorMedium
P = 5 kWQSφ

A single-phase motor takes 5 kW at a power factor of 0.75 lagging from a 230 V supply. Find the line current I.

P = 5 kWpf = 0.75V = 230 V
I = A
16.AC power & power factorHard
P1​ = 59 kWQ1​S1​φ

A 150 kVA single-phase transformer supplies a load of 59 kW at a power factor of 0.7 lagging. How much extra real power ΔP can be added as a resistive (unity power factor) load before the transformer reaches its kVA rating?

Smax = 150 kVAP1 = 59 kWpf1 = 0.7
ΔP = kW
17.Three-phase powerMedium
ABCVL​ = 208 VZ = 5 + j12 Ωper phase

A balanced Δ-connected load with an impedance of 5 + j12 Ω per phase is connected to a balanced three-phase supply with a line-to-line voltage of 208 V. Find the total real power P absorbed by the load in kW.

VL = 208 VZ = 5 + j12 Ω per phase
P = kW
18.Three-phase powerHard
P = 100 kWφ1​S1​Q2​QC​ = ?

A balanced three-phase load takes 100 kW at a power factor of 0.78 lagging from a 400 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.9 lagging. The real power stays the same. Find the total reactive power QC the capacitor bank must supply, in kvar.

P = 100 kWpf1 = 0.78pf2 = 0.9VL = 400 Vf = 50 Hz
QC = kvar
19.TransformersMedium
50 Ω41

A 50 Ω resistor is connected across the secondary winding of an ideal transformer with a turns ratio N₁:N₂ = 4:1. Find the resistance R1′ seen looking into the primary winding.

N1:N2 = 4:1RL = 50 Ω
R1′ = Ω
20.TransformersHard
pf 0.85250 kVA, η = 97%

A single-phase 250 kVA transformer has a core loss of 2000 W. At rated load and a power factor of 0.85 lagging its efficiency is 97%. Find the full-load copper loss Pcu,fl in watts.

S = 250 kVAPcore = 2000 Wpf = 0.85η = 97%
Pcu,fl = W
21.Op-amp circuitsMedium
−+Vout​R2​ = 47 kΩV1​ = −2 VR1​ = 22 kΩV2​ = 1.8 VR3​ = 22 kΩR4​ = 47 kΩ

The difference amplifier uses an ideal op-amp with ±15 V supplies, with R3 = R1 and R4 = R2. Find the output voltage Vout.

V1 = −2 VV2 = 1.8 VR1 = R3 = 22 kΩR2 = R4 = 47 kΩ
Vout = V
22.Op-amp circuitsHard
−+Vout​Rf​ = 4.7 kΩV1​ = 1.9 VR1​ = 1 kΩV2​ = −1.8 VR2​ = 10 kΩ

The summing amplifier uses an ideal op-amp with ±15 V supplies. Find the output voltage Vout.

V1 = 1.9 VV2 = −1.8 VR1 = 1 kΩR2 = 10 kΩRf = 4.7 kΩ
Vout = V
23.Diodes & transistorsMedium
RC​ = 470 Ωβ = 50IC​ = ?VCC​ = 15 VRB​ = 270 kΩ

An NPN transistor with β = 50 is biased by a base resistor RB = 270 kΩ from the supply VCC = 15 V. The collector resistor is RC = 470 Ω and the emitter is grounded. Take VBE = 0.7 V and assume the transistor is in the active region. Find the collector current IC in mA.

VCC = 15 VRB = 270 kΩRC = 470 Ωβ = 50VBE = 0.7 V
IC = mA
24.Diodes & transistorsHard
RC​ = 100 Ωβ = 80VCC​ = 12 V5 VRB​ = ?

An NPN transistor with β = 80 switches a 100 Ω load resistor connected between VCC = 12 V and its collector. The emitter is grounded. The base is driven from a 5 V logic output through a base resistor RB. Take VBE = 0.7 V and VCE(sat) = 0.2 V. Find the largest base resistor RB, in kΩ, that still drives the transistor just into saturation.

VCC = 12 VRC = 100 Ωβ = 80Vin = 5 VVBE = 0.7 VVCE(sat) = 0.2 V
RB = kΩ
25.Number systemsMedium
8-bit two's complement0−12806403201608040201

Set the bits so they store −112 in 8-bit two's complement. Read as an unsigned number, what is the pattern's value U?

N = −1128 bit
U =
26.Number systemsHard
click the bits to set them012806403201608040201

Set the bits to the 8-bit result of 1000 0101 << 3. What is the result's value R in decimal?

1000 0101<< 3
R =
27.Digital logic: gates, K-maps & flip-flopsMedium
ABC00011110010011030214050716

Use the Karnaugh map to find the minimal sum-of-products (SOP) form of F(A, B, C) = Σm(1, 4, 6). How many product terms N does it have?

F(A, B, C) = Σm(1, 4, 6)
N =
28.Digital logic: gates, K-maps & flip-flopsHard
ABCD0001111000011110000103120405X7061121130151140819X11X10

For F(A, B, C, D) = Σm(2, 9, 12, 13, 14) + d(7, 10, 11), where d marks the don't-care conditions, find the number N of essential prime implicants.

F(A, B, C, D) = Σm(2, 9, 12, 13, 14) + d(7, 10, 11)
N =
29.Laplace transformsMedium
ReIm5

Find f(t) for F(s) = 9/(s² + 8s + 41) by completing the square, and evaluate f(0.2).

F(s) = 9/(s² + 8s + 41)t = 0.2 s
f(0.2) =
30.Laplace transformsHard
t (s)y(t)t = 0.4y(0.4) = ?

A system obeys y″ + 6y′ + 5y = 20·u(t), with y(0) = 6 and y′(0) = 0. At t = 0 a step input u(t) = 2 is applied. Use the Laplace transform to find y(0.4).

y″ + 6y′ + 5y = 20·u(t)y(0) = 6y′(0) = 0u(t) = 2t = 0.4 s
y(0.4) =
31.Block diagramsMedium
R(s)+9(s + 4)(s + 2)(s + 3)G(s)C(s)−

A unity negative feedback loop has G(s) = 9(s + 4)/((s + 2)(s + 3)). A step of size 1 is applied at the reference. Find the steady-state error ess.

G(s) = 9(s + 4)/((s + 2)(s + 3))R = 1
ess =
32.Block diagramsHard
R(s)+Kcontroller+D(s)+3s + 10plantC(s)−

A proportional controller K drives the plant G(s) = 3/(s + 10) in a unity negative feedback loop. A disturbance step of size 5 enters at the plant input while R = 0. Find the smallest gain K that keeps the steady-state output at or below 0.075.

G(s) = 3/(s + 10)D = 5css ≤ 0.075
K =
33.Step responseMedium
t (s)y(t)1?

A system has the transfer function G(s) = 78/(s² + 13s + 78) and receives a unit step input. Find the percent overshoot %OS of the step response.

G(s) = 78/(s² + 13s + 78)
%OS = %
34.Step responseHard
+−24 VR = 45 ΩL = 50 mHC = 1 µFvC​

A series RLC circuit with R = 45 Ω, L = 50 mH and C = 1 µF is connected to a 24 V step at t = 0. The capacitor is uncharged and no current flows before the step. Find the percent overshoot %OS of the capacitor voltage.

R = 45 ΩL = 50 mHC = 1 µFV = 24 V
%OS = %
35.Bode plots & marginsMedium
vin​C = 10 nFR = 4.7 kΩvout​

The RC high-pass filter shown has R = 4.7 kΩ, C = 10 nF. A sinusoidal input of 14 kHz is applied. Find the phase shift φ of vout relative to vin, in degrees.

R = 4.7 kΩC = 10 nFf = 14 kHz
φ = °
36.Bode plots & marginsHard
|H| (dB)0.10.1111010100100−80−60−40−2002040ω (rad/s)φ (°)ω (rad/s)−270−180−900ω180​ = ?

A unity-feedback loop has the open-loop transfer function L(s) = 18/(s(s + 1)(s + 7)). Find the phase crossover frequency ω180, where ∠L(jω) = −180°.

L(s) = 18/(s(s + 1)(s + 7))
ω180 = rad/s
37.Stability: Routh–Hurwitz & root locusMedium
R(s)+K = 26.41s(s + 3)(s + 8)C(s)−

The loop in the diagram runs with K = 26.4 and L(s) = K/(s(s + 3)(s + 8)). By what factor m can the gain be raised before the closed loop becomes unstable?

L(s) = K/(s(s + 3)(s + 8))K = 26.4
m =
38.Stability: Routh–Hurwitz & root locusHard
ReImζ = 0.6−1−2−3−4−5j1j2j3

The root locus of L(s) = K/(s(s + 4)) is shown. Find the gain K for which the closed-loop poles have the damping ratio ζ = 0.6.

L(s) = K/(s(s + 4))ζ = 0.6
K =
39.Steady-state error & PID controlMedium
r(t) = 5·t²/2+4(s + 1)s²(s + 4)C(s)−

The parabolic input r(t) = 5·t²/2 is applied to a unity-feedback loop with G(s) = 4(s + 1)/(s²(s + 4)). Find the steady-state error ess.

G(s) = 4(s + 1)/(s²(s + 4))r(t) = 5·t²/2
ess =
40.Steady-state error & PID controlHard
R(s)+K = 105s(s + 2)C(s)−

A proportional controller K = 10 drives the plant G(s) = 5/(s(s + 2)) in a unity-feedback loop. Find the percent overshoot %OS of the step response.

G(s) = 5/(s(s + 2))K = 10
%OS = %

3Solutions

1.Series & parallel resistors

Answer: IR2 = 0.9489 A

Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.

R1​ = 4 ΩR3​ = 8 Ω+−V1​10 VR2​5 ΩAR4​5 ΩB

Combine resistors from the far end

Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.

R3 + R4 = 8 + 5 = 13 Ω
R2 ∥ 13 = 5·13/(5+13) = 3.611 Ω
Req = R1 + 3.611 = 4 + 3.611 = 7.611 Ω

Current from the source

The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.

IR1 = V1/Req = 10/7.611 = 1.314 A

Current through R₂

Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.

VA = V1 − IR1·R1 = 10 − 1.314·4 = 4.745 V
IR2 = VA/R2 = 4.745/5 = 0.9489 A

Answer

IR2 = 0.9489 A
2.Series & parallel resistors

Answer: IR2 = 0.1874 A

Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.

R1​ = 12 ΩR3​ = 5 ΩR5​ = 30 Ω+−V1​15 VR2​30 ΩAR4​5 ΩBR6​12 Ω

Combine resistors from the far end

Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.

R5 + R6 = 30 + 12 = 42 Ω
R4 ∥ 42 = 4.468 Ω
R3 + 4.468 = 9.468 Ω
R2 ∥ 9.468 = 7.197 Ω
Req = R1 + 7.197 = 12 + 7.197 = 19.2 Ω

Current from the source

The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.

IR1 = V1/Req = 15/19.2 = 0.7814 A

Current through R₂

Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.

VA = V1 − IR1·R1 = 15 − 0.7814·12 = 5.623 V
IR2 = VA/R2 = 5.623/30 = 0.1874 A

Answer

IR2 = 0.1874 A
3.Nodal analysis

Answer: PIs = 139.9 W

Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.

KCL at node A

Currents leaving A through the resistors equal the current pushed into A by sources.

VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/20 + (VA − 30)/3 + (VA − VB)/3 = 0
0.7167·VA − 0.3333·VB = 10

KCL at node B

Currents leaving B through the resistors equal the current pushed into B by sources.

VB/R4 + (VB − VA)/R3 = Is
VB/6 + (VB − VA)/3 = 5
−0.3333·VA + 0.5·VB = 5

Solve

Δ = (0.7167)(0.5) − (−0.3333)(−0.3333) = 0.2472
VA = Δ1/Δ = 6.667/0.2472 = 26.97 V
VB = Δ2/Δ = 6.917/0.2472 = 27.98 V

Power delivered by the current source

The source pushes Iₛ up into node B, from ground (0 V) to VB. A source whose current leaves its + end delivers P = V·I.

PIs = VB·Is = 27.98·5 = 139.9 W

Answer

PIs = 139.9 W
4.Nodal analysis

Answer: IR1 = 1.31 A

Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.

Form a supernode

The voltage source between A and B carries an unknown current, so KCL cannot be written at A or B separately. Enclose A, B and the source in one supernode: the current entering it equals the current leaving it.

VB = VA + 8
(VA − V1)/R1 + VA/R2 + VB/R3 = Is

Solve

(VA − 12)/6 + VA/3 + (VA + 8)/5 = 2.5
VA·(1/6 + 1/3 + 1/5) = 2.5 + 12/6 − 8/5 = 2.9
VA = 2.9/0.7 = 4.143 V
VB = 12.14 V

Current through R₁

IR1 = (V1 − VA)/R1 = (12 − 4.143)/6 = 1.31 A

Answer

IR1 = 1.31 A

A negative result means the real current flows against the arrow.

5.Mesh analysis

Answer: IR1 = −0.1316 A

Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.

R1​ = 6 ΩR2​ = 15 Ω+−V1​9 VR3​12 ΩA+−V2​24 VI1​I2​

Assign mesh currents

Draw a clockwise current in each window: I1, I2. A resistor shared by two meshes carries the difference of their currents.

KVL around mesh 1

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R1·I1 + R3(I1 − I2) = V1
6·I1 + 12(I1 − I2) = 9
18·I1 − 12·I2 = 9

KVL around mesh 2

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R2·I2 + R3(I2 − I1) = −V2
15·I2 + 12(I2 − I1) = (−24)
−12·I1 + 27·I2 = −24

Solve

Δ = (18)(27) − (−12)(−12) = 342
I1 = Δ1/Δ = −45/342 = −0.1316 A
I2 = Δ2/Δ = −324/342 = −0.9474 A

Answer

IR1 = I1 = −0.1316 A

A negative mesh current flows anticlockwise.

6.Mesh analysis

Answer: VR2 = 1.623 V

Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.

R1​ = 2 ΩR2​ = 2 ΩR3​ = 8 Ω+−V1​18 VR4​4 ΩAR5​12 ΩB+−V2​9 VI1​I2​I3​

Assign mesh currents

Draw a clockwise current in each window: I1, I2, I3. A resistor shared by two meshes carries the difference of their currents.

KVL around mesh 1

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R1·I1 + R4(I1 − I2) = V1
2·I1 + 4(I1 − I2) = 18
6·I1 − 4·I2 = 18

KVL around mesh 2

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R2·I2 + R4(I2 − I1) + R5(I2 − I3) = 0
2·I2 + 4(I2 − I1) + 12(I2 − I3) = 0
−4·I1 + 18·I2 − 12·I3 = 0

KVL around mesh 3

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R3·I3 + R5(I3 − I2) = −V2
8·I3 + 12(I3 − I2) = (−9)
−12·I2 + 20·I3 = −9

Solve

Δ = det of the coefficient matrix = 976
I1 = Δ1/Δ = 3456/976 = 3.541 A
I2 = Δ2/Δ = 792/976 = 0.8115 A
I3 = Δ3/Δ = 36/976 = 0.03689 A

Answer

IR2 = I2 = 0.8115 A
VR2 = IR2·R2 = 0.8115·2 = 1.623 V

A negative mesh current flows anticlockwise.

7.Superposition

Answer: IR2 = 2.056 A

Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.

R1​ = 4 ΩR3​ = 2 Ω+−V1​24 VR2​4 ΩAR4​5 ΩBOPEN

Case 1 · V1 acting alone

Iₛ becomes an open circuit, so R₃ and R₄ form one series branch from A to ground, in parallel with R₂.

R3+R4 = 2+5 = 7 Ω
R2 ∥ (R3+R4) = 4·7/(4+7) = 2.545 Ω
VA = 24·2.545/(4+2.545) = 9.333 V
VB = VA·R4/(R3+R4) = 9.333·5/7 = 6.667 V
IR2′ = (VA − 0)/R2 = (9.333 − 0)/4 = 2.333 A
R1​ = 4 ΩR3​ = 2 ΩSHORTR2​4 ΩAR4​5 ΩBIs​1 A

Case 2 · Is acting alone

V₁ becomes a short, so R₁ is in parallel with R₂. Iₛ splits at B between R₄ and the path through R₃.

R1 ∥ R2 = 4·4/(4+4) = 2 Ω
Req = R4 ∥ (R3+R1∥R2) = 5 ∥ 4 = 2.222 Ω
VB = Is·Req = (−1)·2.222 = −2.222 V
VA = VB·(R1∥R2)/(R3+R1∥R2) = −2.222·2/4 = −1.111 V
IR2″ = (VA − 0)/R2 = (−1.111 − 0)/4 = −0.2778 A

Add the contributions

IR2 = IR2′ + IR2″
IR2 = 2.333 + (−0.2778) = 2.056 A

A negative result means the real current flows against the arrow.

8.Superposition

Answer: V2 = 41.4 V

Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.

R1​ = 25 ΩR2​ = 3 ΩR4​ = 8 Ω+−V1​15 VR3​3 ΩAOPENBSHORT

Case 1 · V1 acting alone

V₂ becomes a short and Iₛ an open circuit. Seen from A, R₃ is in parallel with the series pair R₂+R₄.

R3 ∥ (R2+R4) = 3 ∥ 11 = 2.357 Ω
VA = 15·2.357/(25+2.357) = 1.292 V
VB = VA·R4/(R2+R4) = 1.292·8/11 = 0.9399 V
R1​ = 25 ΩR2​ = 3 ΩR4​ = 8 ΩSHORTR3​3 ΩAIs​6 ABSHORT

Case 2 · Is acting alone

Both voltage sources become shorts. Iₛ splits at B between R₄ (now to ground) and R₂ in series with R₁ ∥ R₃. The arrow of Iₛ points down, away from its node, so Iₛ draws current out of that node: its term enters with a minus sign.

R1 ∥ R3 = 2.679 Ω, so the left path is R2+2.679 = 5.679 Ω
Req = R4 ∥ 5.679 = 3.321 Ω
VB = −Is·Req = −6·3.321 = −19.93 V
VA = VB·2.679/5.679 = −9.399 V

Case 3 · V2 acting alone, per volt

V₁ becomes a short and Iₛ an open circuit. R₁ ∥ R₃ hangs from A, in series with R₂ back to B.

R1 ∥ R3 = 2.679 Ω
VA‴ = V2·2.679/(8 + 3 + 2.679) = 0.1958·V2

Set VA to zero

With VA = 0 there is no voltage across R₃, so its current is zero.

VA′ + VA″ + VA‴ = 1.292 + (−9.399) + 0.1958·V2 = 0
V2 = 8.107/0.1958 = 41.4 V

Answer

V2 = 41.4 V
9.Thévenin & Norton

Answer: IN = 0.625 A

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 10 ΩR3​ = 4 ΩSHORTR2​4 ΩAabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 10·4/(10+4) = 2.857 Ω
Rth = (R1 ∥ R2) + R3 = 2.857 + 4 = 6.857 Ω
R1​ = 10 ΩR3​ = 4 Ω+−V1​15 VR2​4 ΩAab+−Vth​

Find Vth, the open-circuit voltage

With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.

Vth = V1·R2/(R1+R2) = 15·4/(10+4) = 4.286 V
IN​0.625 ARth​6.857 Ωab

Norton equivalent

A Norton source is the same circuit seen as a current source in parallel with R_th. Its current is the short-circuit current at a–b.

IN = Vth/Rth = 4.286/6.857 = 0.625 A
10.Thévenin & Norton

Answer: IN = 4.409 A

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 6 ΩR3​ = 8 ΩSHORTR2​6 ΩAOPENBabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 6·6/(6+6) = 3 Ω
Rth = (R1 ∥ R2) + R3 = 3 + 8 = 11 Ω
R1​ = 6 ΩR3​ = 8 Ω+−V1​9 VR2​6 ΩAIs​4 ABab+−Vth​

Find Vth, the open-circuit voltage

With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.

VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 4.5 + 4·3 = 16.5 V
Vth = VB = VA + Is·R3 = 16.5 + 4·8 = 48.5 V
IN​4.409 ARth​11 Ωab

Norton equivalent

A Norton source is the same circuit seen as a current source in parallel with R_th. Its current is the short-circuit current at a–b.

IN = Vth/Rth = 48.5/11 = 4.409 A
11.RC & RL transients

Answer: W(∞) = 440 mJ

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Time constant and final current

Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.

τ = L/R = 220 mH / 5 Ω = 44 ms
i(∞) = Vs/R = 10/5 = 2 A

Stored energy

W(∞) = ½·L·i(∞)² = ½·220·2² = 440 mJ

Answer

W(∞) = 440 mJ
12.RC & RL transients

Answer: vC = 15.96 V

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Initial value, final value, time constant

The capacitor voltage cannot jump, so it starts at its stored value and heads for the source voltage.

vC(0) = 12 V, vC(∞) = Vs = 24 V
τ = R·C = 6.8 kΩ · 22 µF = 149.6 ms
vC(t) = 24 + (12 − 24)·e−t/τ

Voltage at the given time

vC(60) = 24 + (−12)·e−60/149.6 = 15.96 V

Answer

vC = 15.96 V
13.AC impedance & phasors

Answer: L = 149.7 mH

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Resonance condition

At resonance the inductive and capacitive reactances cancel: ωL = 1/(ωC).

ω₀ = 2π·60 = 377 rad/s
L = 1/(ω₀²·C) = 1/(377²·47·10⁻⁶) = 149.7 mH

Answer

L = 149.7 mH
14.AC impedance & phasors

Answer: |Z| = 39.4 Ω

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactance

XC = 1/(2π·200·47·10⁻⁶) = 16.93 Ω

Parallel combination

Multiply top and bottom by the complex conjugate to split Zp into real and imaginary parts.

Zp = R₂·(−jXC)/(R₂ − jXC) = (R₂·XC² − jR₂²·XC)/(R₂² + XC²)
Zp = 7.247 − j12.84 Ω

Total impedance

Z = 30 + 7.247 − j12.84 = 37.25 − j12.84 Ω
|Z| = √(37.25² + 12.84²) = 39.4 Ω

Answer

|Z| = 39.4 Ω
15.AC power & power factor

Answer: I = 28.99 A

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Line current

Only the real part of the power does work, so divide by the power factor.

I = P/(V·cos φ) = 5000/(230·0.75) = 28.99 A

Answer

I = 28.99 A
16.AC power & power factor

Answer: ΔP = 78.39 kW

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Reactive power of the existing load

Q1 = 59·tan(arccos 0.7) = 60.19 kvar

Largest total real power

At full rating S = Smax, and Q is unchanged by the resistive load.

P = √(Smax² − Q1²) = √(150² − 60.19²) = 137.4 kW

Extra real power

ΔP = 137.4 − 59 = 78.39 kW

Answer

ΔP = 78.39 kW
17.Three-phase power

Answer: P = 3.84 kW

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.

Phase voltage

Vph = VL = 208 V

Phase current

|Z| = √(5² + 12²) = 13 Ω
Iph = 208/13 = 16 A

Total real power

Only the resistive part of each impedance absorbs real power.

P = 3·Iph²·R = 3·16²·5 = 3.84 kW

Answer

P = 3.84 kW

Check: cos φ = R/|Z| = 0.3846, and √3·VL·IL·cos φ gives the same power.

18.Three-phase power

Answer: QC = 31.8 kvar

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.

Reactive power before and after

The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.

Q1 = 100·tan(acos 0.78) = 100·0.8023 = 80.23 kvar
Q2 = 100·tan(acos 0.9) = 100·0.4843 = 48.43 kvar

Reactive power from the capacitors

QC = Q1 − Q2 = 31.8 kvar

Answer

QC = 31.8 kvar
19.Transformers

Answer: R1′ = 800 Ω

Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.

Referred resistance

The voltage goes up by a and the current down by a, so the ratio V/I goes up by a².

R1′ = a²·RL = 4²·50 = 800 Ω

Answer

R1′ = 800 Ω
20.Transformers

Answer: Pcu,fl = 4572 W

Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.

Output and input power

Pout = 250·0.85 = 212.5 kW
Pin = 212500/0.97 = 219072 W

Total and copper losses

Ploss = 219072 − 212500 = 6572 W
Pcu,fl = 6572 − 2000 = 4572 W

Answer

Pcu,fl = 4572 W
21.Op-amp circuits

Answer: Vout = 8.118 V

Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.

Voltage at the inputs

R₃ and R₄ carry the same current, so they form a voltage divider; feedback makes V₋ = V₊.

V₊ = V2·R4/(R3 + R4) = 1.8·47/(22 + 47) = 1.226 V
V₋ = V₊

KCL at the inverting input

(−2 − 1.226)/22 = (1.226 − Vout)/47
Vout = (R2/R1)·(V2 − V1) = (47/22)·(1.8 − (−2)) = 8.118 V

Answer

Vout = 8.118 V
22.Op-amp circuits

Answer: Vout = −8.084 V

Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.

Input currents

V₋ = 0, so each input resistor has its full input voltage across it.

I1 = V1/R1 = 1.9/1 = 1.9 mA
I2 = V2/R2 = −1.8/10 = −0.18 mA
If = I1 + I2 = 1.72 mA

Output voltage

Vout = −Rf·If = −4.7·1.72 = −8.084 V

Answer

Vout = −8.084 V
23.Diodes & transistors

Answer: IC = 2.648 mA

BJT bias point: in the active region VBE = 0.7 V, IC = β·IB and IE = (β + 1)·IB. Find IB from the base loop with KVL, then IC, then VCE from the collector–emitter loop. A voltage divider at the base is replaced by its Thévenin equivalent VTH = VCC·R₂/(R₁ + R₂), RTH = R₁∥R₂; an emitter resistor appears (β + 1) times larger in the base loop.

Base current

IB = (VCC − VBE)/RB = (15 − 0.7)/270 kΩ = 52.96 µA

Collector current

IC = β·IB = 50·52.96 µA = 2.648 mA

Answer

IC = 2.648 mA

Check: VCE = 13.76 V is well above 0.2 V, so the transistor is indeed active.

24.Diodes & transistors

Answer: RB = 2.915 kΩ

BJT as a switch: to switch a load fully on, the transistor is driven into saturation, where VCE = VCE(sat) and the collector current is set by the load: IC(sat) = (VCC − VCE(sat))/RC. Saturation needs at least IB = IC(sat)/β. If the base current is smaller, the transistor stays active and IC = β·IB.

Collector current in saturation

IC(sat) = (12 − 0.2)/100 = 118 mA

Minimum base current

IB(min) = IC(sat)/β = 118/80 = 1475 µA

Base resistor

RB = (5 − 0.7)/IB = 4.3 V/1.475 mA = 2.915 kΩ

Answer

RB = 2.915 kΩ

Any smaller base resistor also saturates the transistor; in practice you pick one a few times smaller.

25.Number systems

Answer: U = 144

Setting bits: each bit is worth a power of two (128, 64, …, 1). One hex digit is exactly four bits, and in 8-bit two's complement the leftmost bit is worth −128. Bitwise operations work on each bit position separately.

Invert and add one

112 = 0111 0000
inverted: 1000 1111
+1 → 1001 0000

Read it as unsigned

1001 0000₂ = 256 − 112 = 144

Answer

U = 144
26.Number systems

Answer: R = 40

Setting bits: each bit is worth a power of two (128, 64, …, 1). One hex digit is exactly four bits, and in 8-bit two's complement the leftmost bit is worth −128. Bitwise operations work on each bit position separately.

Bit by bit

Shifting left by 3 moves every bit 3 places to the left; bits that fall off the left end are lost and zeros come in on the right.

1000 0101 << 3
= 0010 1000

Value of the result

0010 1000₂ = 40

Answer

R = 40
27.Digital logic: gates, K-maps & flip-flops

Answer: N = 2

Karnaugh maps: the cells are ordered in Gray code (00, 01, 11, 10), so neighbouring cells, including the ones across the edges, differ in exactly one variable. Group the 1s in rectangles of 1, 2, 4, 8 or 16 cells, as large as possible and as few as possible, until every 1 is covered. Each group is one product term: the variables that stay constant inside it. A group of 2ᵏ cells loses k variables. Don't-cares (X) may be used to make groups bigger but never have to be covered. Grouping the 0s instead gives the minimal POS form.

ABC00011110010011030214050716

Group the 1s

Every group is a rectangle of 2ᵏ cells; edge cells are neighbours of the cells on the opposite edge.

AC′
A′B′C

Minimal SOP form

F = AC′ + A′B′C
N = 2

Answer

N = 2
28.Digital logic: gates, K-maps & flip-flops

Answer: N = 1

Karnaugh maps: the cells are ordered in Gray code (00, 01, 11, 10), so neighbouring cells, including the ones across the edges, differ in exactly one variable. Group the 1s in rectangles of 1, 2, 4, 8 or 16 cells, as large as possible and as few as possible, until every 1 is covered. Each group is one product term: the variables that stay constant inside it. A group of 2ᵏ cells loses k variables. Don't-cares (X) may be used to make groups bigger but never have to be covered. Grouping the 0s instead gives the minimal POS form.

Prime implicants

The largest groups that can be formed from 1s and Xs.

B′CD′, AC′D, ACD′, AB′D, ABD′, ABC′
ABCD0001111000011110000103120405X7061121130151140819X11X10

Essential prime implicants

B′CD′
N = 1

Answer

N = 1
29.Laplace transforms

Answer: f(0.2) = 0.6806

Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).

Complete the square

s² + 8s + 41 = (s + 4)² + 25 = (s + 4)² + 5²

Match the numerator

F(s) = (9/5)·5/((s + 4)² + 5²)

Inverse transform

f(t) = e−4t·(1.8·sin 5t)
f(0.2) = e−4·0.2·(1.8·sin(5·0.2)) = 0.6806

Answer

f(0.2) = 0.6806
30.Laplace transforms

Answer: y(0.4) = 6.392

Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).

Transform the equation

(s² + 6s + 5)·Y(s) = 6s + 36 + 40/s
Y(s) = (6s² + 36s + 40)/(s(s + 1)(s + 5))

Partial fractions

A = 40/(1·5) = 8
B = 10/((−1)·4) = −2.5
C = 10/((−5)·(−4)) = 0.5

Result

y(t) = 8 − 2.5·e−t + 0.5·e−5t
y(0.4) = 6.392

Answer

y(0.4) = 6.392

Check: y(0) = A + B + C = 6.

31.Block diagrams

Answer: ess = 0.1429

Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).

Position error constant

Kₚ = G(0) = 9·4/(2·3) = 6

Steady-state error

ess = A/(1 + Kₚ) = 1/(1 + 6) = 0.1429

Answer

ess = 0.1429
32.Block diagrams

Answer: K = 63.33

Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).

Disturbance response

css = D·G(0)/(1 + K·G(0)) = 5·3/(10 + 3K)

Solve for K

10 + 3K = 5·3/0.075 = 200
K = (200 − 10)/3 = 63.33

Answer

K = 63.33
33.Step response

Answer: %OS = 3.287 %

Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).

Compare with the standard form

The denominator must match s² + 2ζωₙs + ωₙ².

ωₙ² = 78 → ωₙ = 8.832 rad/s
2ζωₙ = 13 → ζ = 13/(2·8.832) = 0.736

Result

%OS = 100·e−ζπ/√(1−ζ²) = 100·e−3.415 = 3.287 %

Answer

%OS = 3.287 %
34.Step response

Answer: %OS = 72.78 %

Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).

Natural frequency and damping ratio

ωₙ = 1/√(LC) = 1/√(0.05·1 × 10⁻⁶) = 4472 rad/s
ζ = (R/2)·√(C/L) = (45/2)·√(1 × 10⁻⁶/0.05) = 0.1006

Result

%OS = 100·e−ζπ/√(1−ζ²) = 72.78 %

Answer

%OS = 72.78 %
35.Bode plots & margins

Answer: φ = 13.6 °

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Corner frequency

ωc = 1/(RC) = 1/(4700·1 × 10⁻⁸) = 21277 rad/s
fc = 3386 Hz → f/fc = 14000/3386 = 4.134

Phase

φ = 90° − atan(4.134) = 13.6°

Answer

φ = 13.6°
36.Bode plots & margins

Answer: ω180 = 2.646 rad/s

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Phase crossover

(ω/1)·(ω/7) = 1 → ω180 = √(1·7) = 2.646 rad/s

Answer

ω180 = 2.646 rad/s
37.Stability: Routh–Hurwitz & root locus

Answer: m = 10

Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.

Routh array

s³ + 11s² + 24s + K = 0
s³: 1, 24
s²: 11, K
s¹: (11·24 − K)/11
s⁰: K

Largest stable gain

Kmax = 11·24 = 264

Factor

m = 264/26.4 = 10

Answer

m = 10

This factor is the gain margin as a ratio: 20 dB.

38.Stability: Routh–Hurwitz & root locus

Answer: K = 11.11

Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.

Compare with the standard form

s² + 4s + K = s² + 2ζωₙs + ωₙ²
2·0.6·ωₙ = 4 → ωₙ = 3.333 rad/s

Gain

K = ωₙ² = 3.333² = 11.11

Answer

K = 11.11

The closed-loop poles sit where the ζ line crosses the vertical branch at s = −2.

39.Steady-state error & PID control

Answer: ess = 5

Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.

Acceleration constant

Ka = 4·1/4 = 1

Parabola error

ess = 5/1 = 5

Answer

ess = 5
40.Steady-state error & PID control

Answer: %OS = 63.84 %

P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).

Characteristic polynomial

s(s + 2) + 10·5 = s² + 2s + 50

ωₙ and ζ

ωₙ = √50 = 7.071 rad/s
ζ = 2/(2·7.071) = 0.1414

Overshoot

%OS = 100·e−0.1414π/√(1 − 0.1414²) = 63.84 %

Answer

%OS = 63.84 %

This is independent practice material. ExamProblems is not affiliated with or endorsed by the organisation that runs this exam, and the exam name is used only to describe the content. The FE exam is run by NCEES, which is not affiliated with ExamProblems and does not endorse it.

ExamProblems · examproblems.com/courses/fe-exam-electrical