FE Electrical and Computer exam practice: cram pack

Formula sheets, the key method steps for every topic and 40 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

Series & parallel resistors

Resistors in series
Req = R1 + R2 + …
Resistors in parallel
1/Req = 1/R1 + 1/R2 + …
Two in parallel
Req = R1R2 / (R1 + R2)
Ohm's law
V = I·R
Power
P = V·I = I²R = V²/R

Method

  1. Start at the end of the network furthest from the terminals.
  2. Combine resistors in series by adding them, and resistors in parallel with 1/R = 1/R₁ + 1/R₂ + …
  3. Redraw the circuit after each step.
  4. Repeat until one resistor is left between the terminals.

Nodal analysis

Kirchhoff’s current law
ΣIin = ΣIout
Branch current
I = (Va − Vb)/R
Reference node
Vground = 0

Method

  1. Choose a reference node (ground) and label the other node voltages.
  2. Write Kirchhoff’s current law at every unknown node: currents leaving through each branch equal the currents entering.
  3. Express every branch current as (Va − Vb)/R.
  4. Solve the system of equations, then find any current you need.

Mesh analysis

Kirchhoff’s voltage law
ΣV = 0 around every loop
Shared resistor
current = I1 − I2
Current source in a mesh
fixes that mesh current

Method

  1. Draw a clockwise current in every mesh (window) of the circuit.
  2. Apply Kirchhoff’s voltage law around each mesh: the sum of voltage drops is zero.
  3. In a resistor shared by two meshes the current is the difference of the two mesh currents.
  4. Solve the equations; a negative result means the current flows the other way.

Superposition

Superposition
x = x1 + x2 + … (one source at a time)
Switched-off voltage source
short circuit (0 V)
Switched-off current source
open circuit (0 A)
Voltage divider
V2 = V·R2/(R1 + R2)
Current divider
I1 = I·R2/(R1 + R2)

Method

  1. Count the independent sources. You will solve one simpler circuit per source.
  2. Keep one source and switch off the others: a voltage source becomes a short circuit (a wire), a current source becomes an open circuit (a gap).
  3. Solve the simpler circuit for the voltage or current you need, keeping track of its direction.
  4. Repeat for every source, then add the contributions with their signs.

Thévenin & Norton

Thévenin voltage
Vth = Vopen circuit
Thévenin resistance
Rth: all sources off, seen from a–b
Norton current
IN = Vth/Rth
Load current
IL = Vth/(Rth + RL)
Maximum power transfer
RL = Rth, Pmax = Vth²/(4Rth)

Method

  1. Remove the load and mark the two terminals a and b.
  2. Find the open-circuit voltage between a and b: this is Vth.
  3. Switch off all independent sources and find the resistance seen from a–b: this is Rth.
  4. Put the load back on the equivalent circuit: Vth in series with Rth.
  5. For the Norton equivalent, convert: IN = Vth/Rth, with RN = Rth in parallel.

RC & RL transients

Time constant
τ = RC | τ = L/R
Response
x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ
Capacitor at DC
open circuit; vC cannot jump
Inductor at DC
short circuit; iL cannot jump
Settled
t ≈ 5τ

Method

  1. Find the initial value just after switching: a capacitor voltage and an inductor current cannot jump.
  2. Find the final value long after switching: a capacitor acts as an open circuit, an inductor as a short circuit.
  3. Find the time constant: τ = RC or τ = L/R, using the resistance seen by the capacitor or inductor.
  4. Use x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ.

AC impedance & phasors

Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z

Method

  1. Convert the frequency: ω = 2πf.
  2. Find each reactance: XL = ωL and XC = 1/(ωC).
  3. Add impedances like resistors, with Z = R + jX.
  4. Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.

AC power & power factor

Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)

Three-phase power

Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η

Transformers

Turns ratio
a = N1/N2 = V1/V2
Current ratio
I1/I2 = N2/N1 = 1/a
Rated current
I = S/V
Referred impedance
Z1′ = a²·ZL
Copper loss at part load
Pcu = x²·Pcu,fl
Efficiency
η = x·S·pf/(x·S·pf + Pcore + x²·Pcu,fl)
Maximum efficiency
x = √(Pcore/Pcu,fl)

Op-amp circuits

Inverting amplifier
Vout = −(Rf/Rin)·Vin
Non-inverting amplifier
Vout = (1 + Rf/R1)·Vin
Summing amplifier
Vout = −Rf(V1/R1 + V2/R2)
Ideal op-amp
V+ = V−, Iin = 0

Diodes & transistors

Diode (constant drop)
VD = 0.7 V when conducting
Active region
VBE = 0.7 V, IC = β·IB, IE = (β + 1)·IB
Fixed bias
IB = (VCC − 0.7)/RB
Divider bias
IB = (VTH − 0.7)/(RTH + (β + 1)RE)
Thévenin of the divider
VTH = VCC·R2/(R1 + R2), RTH = R1∥R2
Collector loop
VCE = VCC − ICRC − IERE
Saturation
IC(sat) = (VCC − VCE(sat))/RC, IB ≥ IC(sat)/β

Number systems

Place values
binary 2k, octal 8k, hex 16k
To decimal
Σ dk·bk
From decimal
divide by the base, read the remainders bottom-up
Hex ↔ binary
one hex digit = 4 bits
Two’s complement
invert the bits and add 1

Digital logic: gates, K-maps & flip-flops

Basic gates
A·B, A + B, A′, (A·B)′, (A + B)′, A ⊕ B
Boolean rules
X + X′ = 1, X·X′ = 0, X + XY = X, XY + XY′ = X
De Morgan
(X·Y)′ = X′ + Y′, (X + Y)′ = X′·Y′
Karnaugh map order
00, 01, 11, 10 (Gray code)
Group of 2ᵏ cells
loses k variables
4-to-1 multiplexer
F = A′B′I0 + A′BI1 + AB′I2 + ABI3
Flip-flops
D: Q⁺ = D, T: Q⁺ = T ⊕ Q, JK: Q⁺ = JQ′ + K′Q
Counters
n-bit: 2ⁿ states; mod-N: smallest n with 2ⁿ ≥ N; fout = fclk/N
Ripple counter
fmax = 1/(n·tpd)
Ring and Johnson counters
n and 2n states

Method

  1. For a circuit, work from the inputs to the output one gate at a time and write the value on every wire, or write its expression and fill in the truth table.
  2. For simplification, put the 1s (and the don’t-cares as X) into a Karnaugh map with Gray-code rows and columns: 00, 01, 11, 10.
  3. Cover the 1s with as few and as large groups of 1, 2, 4, 8 or 16 cells as possible, wrapping round the edges; each group is one product term made of the variables that stay constant. Group the 0s for the POS form.
  4. For flip-flops and counters, read the inputs at each active clock edge, write the state after every edge, and remember that an n-bit counter wraps round after 2ⁿ states.

Stability: Routh–Hurwitz & root locus

Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)

Method

  1. Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
  2. Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
  3. Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
  4. For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.

Steady-state error & PID control

System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)

Method

  1. Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
  2. Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
  3. Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
  4. For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².

2Practice problems

1.Series & parallel resistorsMedium
R1​ = 10 ΩR3​ = 20 Ω+−V1​24 VR2​6 ΩAR4​3 ΩB

Find the equivalent resistance Req seen by the source V1.

V1 = 24 VR1 = 10 ΩR2 = 6 ΩR3 = 20 ΩR4 = 3 Ω
Req = Ω
2.Series & parallel resistorsHard
R1​ = 2 ΩIR1​R3​ = 10 ΩR5​ = 15 Ω+−V1​10 VR2​12 ΩAR4​3 ΩBR6​20 Ω

Find the current IR1 delivered by the source, which flows through R1.

V1 = 10 VR1 = 2 ΩR2 = 12 ΩR3 = 10 ΩR4 = 3 ΩR5 = 15 ΩR6 = 20 Ω
IR1 = A
3.Nodal analysisMedium
R1​ = 12 ΩR3​ = 6 Ω+−V1​12 VR2​3 ΩAR4​12 ΩBIs​3 A

Use nodal analysis to find the node voltage VA (measured from ground).

V1 = 12 VIs = 3 AR1 = 12 ΩR2 = 3 ΩR3 = 6 ΩR4 = 12 Ω
VA = V
4.Nodal analysisHard
R1​ = 3 ΩR2​ = 6 ΩIR2​R4​ = 6 Ω+−V1​6 VR3​30 ΩAR5​5 ΩBIs​2 A+−V2​12 V

Use nodal analysis to find the current IR2 through R2 in the direction of the arrow.

V1 = 6 VIs = 2 AV2 = 12 VR1 = 3 ΩR2 = 6 ΩR3 = 30 ΩR4 = 6 ΩR5 = 5 Ω
IR2 = A
5.Mesh analysisMedium
R1​ = 20 ΩR2​ = 10 Ω+−V1​24 VR3​3 ΩA+−V2​9 VI1​I2​

Use mesh analysis to find the mesh current I1 (clockwise).

V1 = 24 VV2 = 9 VR1 = 20 ΩR2 = 10 ΩR3 = 3 Ω
I1 = A
6.Mesh analysisHard
R1​ = 10 ΩR2​ = 5 ΩR3​ = 8 Ω+−V1​18 VR4​30 Ω+−VR4​AR5​4 ΩB+−V2​15 VI1​I2​I3​

Use mesh analysis to find the voltage VR4 across R4 with the polarity shown.

V1 = 18 VV2 = 15 VR1 = 10 ΩR2 = 5 ΩR3 = 8 ΩR4 = 30 ΩR5 = 4 Ω
VR4 = V
7.SuperpositionMedium
R1​ = 12 ΩR3​ = 5 Ω+−V1​10 VR2​2 ΩIR2​AR4​4 ΩBIs​1.5 A

Use superposition to find the current IR2 through R2 in the direction of the arrow.

V1 = 10 VIs = 1.5 AR1 = 12 ΩR2 = 2 ΩR3 = 5 ΩR4 = 4 Ω
IR2 = A
8.SuperpositionHard
R1​ = 8 ΩIR1​R2​ = 25 ΩR4​ = 12 Ω+−V1​18 VR3​30 ΩAIs​2 AB+−V2​10 V

Use superposition to find the power PR1 absorbed by R1.

V1 = 18 VIs = 2 AV2 = 10 VR1 = 8 ΩR2 = 25 ΩR3 = 30 ΩR4 = 12 Ω
PR1 = W
9.Thévenin & NortonMedium
R1​ = 10 ΩR3​ = 5 Ω+−V1​15 VR2​10 ΩAab

Find the Thévenin resistance Rth seen from terminals a–b.

V1 = 15 VR1 = 10 ΩR2 = 10 ΩR3 = 5 Ω
Rth = Ω
10.Thévenin & NortonHard
R1​ = 30 ΩR3​ = 5 Ω+−V1​24 VR2​8 ΩAIs​3 ABab

Find the Thévenin voltage Vth seen from terminals a–b.

V1 = 24 VIs = 3 AR1 = 30 ΩR2 = 8 ΩR3 = 5 Ω
Vth = V
11.RC & RL transientsMedium
+−Vs​30 Vt = 0R1​ = 1 kΩR2​ = 2.2 kΩC68 µF+−vC​

The source Vₛ charges the capacitor through R₁, and R₂ is connected in parallel with C. The capacitor is uncharged when the switch closes at t = 0. Find the capacitor voltage vC at t = 40 ms.

Vs = 30 VR1 = 1 kΩR2 = 2.2 kΩC = 68 µFt = 40 ms
vC = V
12.RC & RL transientsHard
+−Vs​10 VR1​ = 33 ΩR2​ = 47 Ωopens at t = 0L33 mHi(t)

The switch across R2 has been closed for a long time, so the inductor current is steady. At t = 0 the switch opens. How long after t = 0 does the inductor current reach 0.178 A? Find t.

Vs = 10 VR1 = 33 ΩR2 = 47 ΩL = 33 mH
t = ms
13.AC impedance & phasorsMedium
50 V200 HzR = 30 ΩL = 20 mHC = 47 µFI

A series RLC circuit is connected to a 50 V (rms), 200 Hz supply. Find the rms current I.

V = 50 V (rms)f = 200 HzR = 30 ΩL = 20 mHC = 47 µF
I = A
14.AC impedance & phasorsHard
24 V60 HzR = 50 ΩL = 20 mHC = 47 µF+−VC​

A series RLC circuit is connected to a 24 V (rms), 60 Hz supply. Find the rms voltage VC across the capacitor.

V = 24 V (rms)f = 60 HzR = 50 ΩL = 20 mHC = 47 µF
VC = V
15.AC power & power factorMedium
400 V18 kW, 0.7226 kW, 0.7I = ?

Two loads are connected in parallel to a 400 V single-phase supply: an 8 kW load at a power factor of 0.7 lagging and a 26 kW load at a power factor of 0.7 leading. Find the total current I drawn from the supply.

V = 400 VP1 = 8 kW, pf1 = 0.7 laggingP2 = 26 kW, pf2 = 0.7 leading
I = A
16.AC power & power factorHard
P = 5 kWQ1​S1​φ1​QC​

A single-phase load takes 5 kW at a power factor of 0.6 lagging from a 400 V, 60 Hz supply. A capacitor connected in parallel raises the power factor to 0.95. Find the capacitance C needed.

P = 5 kWpf1 = 0.6pf2 = 0.95V = 400 Vf = 60 Hz
C = µF
17.Three-phase powerMedium
ABCVL​ = 400 VIL​ = ?M18.5 kW, η = 90%cos φ = 0.85

A three-phase induction motor delivers 18.5 kW of mechanical output power at full load. At this load its efficiency is 90% and its power factor is 0.85 lagging. The supply has a line-to-line voltage of 400 V. Find the line current IL.

Pout = 18.5 kWη = 90%cos φ = 0.85VL = 400 V
IL = A
18.Three-phase powerHard
P = 200 kWφ1​S1​Q2​QC​

A balanced three-phase load takes 200 kW at a power factor of 0.65 lagging from a 415 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.92 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.

P = 200 kWpf1 = 0.65pf2 = 0.92VL = 415 Vf = 50 Hz
Cph = µF
19.TransformersMedium
8 ΩN1​N2​288 Ω

An amplifier with an output resistance of 288 Ω drives an 8 Ω loudspeaker through an ideal transformer. For maximum power transfer the loudspeaker must look like 288 Ω from the amplifier. Find the turns ratio a = N₁/N₂.

Rs = 288 ΩRL = 8 Ω
a =
20.TransformersHard
pf 0.85200 kVA, η = 98%

A single-phase 200 kVA transformer has a core loss of 1000 W. At rated load and a power factor of 0.85 lagging its efficiency is 98%. Find the full-load copper loss Pcu,fl in watts.

S = 200 kVAPcore = 1000 Wpf = 0.85η = 98%
Pcu,fl = W
21.Op-amp circuitsMedium
−+Vout​Rf​ = 100 kΩR1​ = 100 kΩVin​ = −0.5 VRa​ = 2 kΩRb​ = 22 kΩ

The op-amp is ideal and runs from ±15 V supplies. Find the output voltage Vout.

Vin = −0.5 VRa = 2 kΩRb = 22 kΩR1 = 100 kΩRf = 100 kΩ
Vout = V
22.Op-amp circuitsHard
−+Vout​Rf​ = 22 kΩV1​ = −1.6 VR1​ = 47 kΩV2​ = 0.1 VR2​ = 22 kΩIf​

The summing amplifier uses an ideal op-amp with ±15 V supplies. Find the current If through the feedback resistor, flowing towards the output.

V1 = −1.6 VV2 = 0.1 VR1 = 47 kΩR2 = 22 kΩRf = 22 kΩ
If = mA
23.Diodes & transistorsMedium
RC​ = 1.5 kΩβ = 200IC​ = ?RE​ = 470 ΩVCC​ = 12 VR1​ = 56 kΩR2​ = 10 kΩ

An NPN transistor with β = 200 has voltage-divider bias from VCC = 12 V: R₁ = 56 kΩ from VCC to the base and R₂ = 10 kΩ from the base to ground. The collector resistor is RC = 1.5 kΩ and the emitter resistor is RE = 470 Ω. Take VBE = 0.7 V and use the Thévenin equivalent of the divider (do not neglect the base current). Find the collector current IC in mA.

VCC = 12 VR1 = 56 kΩR2 = 10 kΩRC = 1.5 kΩRE = 470 Ωβ = 200
IC = mA
24.Diodes & transistorsHard
RC​ = 470 Ωβ = 200IC​ = ?VCC​ = 5 V5 VRB​ = 1 kΩ

An NPN transistor with β = 200 switches a 470 Ω load resistor connected between VCC = 5 V and its collector. The emitter is grounded. The base is driven from a 5 V logic output through a base resistor RB = 1 kΩ. Take VBE = 0.7 V and VCE(sat) = 0.2 V. Find the collector current IC in mA when the input is high. Decide first whether the transistor is saturated.

VCC = 5 VRC = 470 Ωβ = 200Vin = 5 VVBE = 0.7 VVCE(sat) = 0.2 VRB = 1 kΩ
IC = mA
25.Number systemsMedium
8-bit two's complement0−12806403201608040201

Set the bits so they store −79 in 8-bit two's complement. Read as an unsigned number, what is the pattern's value U?

N = −798 bit
U =
26.Number systemsHard
click the bits to set them012806403201608040201

Set the bits to the 8-bit result of 0110 0011 AND 0110 0010. What is the result's value R in decimal?

0110 0011AND0110 0010
R =
27.Digital logic: gates, K-maps & flip-flopsMedium
MUXC′I0​CI1​0I2​0I3​ABS1​S0​F

A 4-to-1 multiplexer has its select inputs S₁ = A and S₀ = B, and its data inputs tied to I₀ = C′, I₁ = C, I₂ = 0, I₃ = 0. For how many of the 8 combinations of A, B and C is the output F = 1? Find N.

I₀ = C′I₁ = CI₂ = 0I₃ = 0
N =
28.Digital logic: gates, K-maps & flip-flopsHard
CLKT123456

A positive-edge-triggered T flip-flop starts with Q = 0 and receives the inputs shown. Click the first clock edge at which Q goes from 1 back to 0.

Q₀ = 0T
  1. 1clock edge 1
  2. 2clock edge 2
  3. 3clock edge 3
  4. 4clock edge 4
  5. 5clock edge 5
  6. 6clock edge 6
29.Laplace transformsMedium
t (s)f(t)t = 0.75f(0.75) = ?

Find f(t) for F(s) = 10/(s(s + 1)(s + 6)) by partial fractions, and evaluate f(0.75).

F(s) = 10/(s(s + 1)(s + 6))t = 0.75 s
f(0.75) =
30.Laplace transformsHard
t (s)y(t)t = 0.25y(0.25) = ?

A system obeys y″ + 9y′ + 18y = 9·u(t). It starts at rest (y(0) = 0, y′(0) = 0) and the input is a step u(t) = 10 for t ≥ 0. Use the Laplace transform to find the output y(0.25).

y″ + 9y′ + 18y = 9·u(t)u(t) = 10y(0) = 0, y′(0) = 0t = 0.25 s
y(0.25) =
31.Block diagramsMedium
R(s)+K(s + 5)(s + 10)G(s)C(s)−

The plant G(s) = K/((s + 5)(s + 10)) is in a unity negative feedback loop. Find the gain K for which the closed loop is critically damped (two equal real poles).

G(s) = K/((s + 5)(s + 10))unity negative feedback
K =
32.Block diagramsHard
R(s)+22s(s + 11)G(s)C(s)2H−

The plant G(s) = 22/(s(s + 11)) is in a negative feedback loop with sensor gain H = 2. The closed-loop poles are complex. Find their real part σ.

G(s) = 22/(s(s + 11))H = 2
σ =
33.Step responseMedium
t (s)y(t)0.5ts​ = ?

A system has the transfer function G(s) = 8/(s² + s + 16) and receives a unit step input. Find the 2 % settling time ts of the step response, using ts ≈ 4/(ζωₙ).

G(s) = 8/(s² + s + 16)
ts = s
34.Step responseHard
k = 100 N/mc = 3 N·s/mm = 2 kgF = 25 Nx(t)

A mass m = 2 kg hangs on a spring k = 100 N/m with a viscous damper c = 3 N·s/m (m·x″ + c·x′ + k·x = F). At rest in equilibrium, a constant force F = 25 N is suddenly applied. Find the largest displacement xmax in mm.

m = 2 kgk = 100 N/mc = 3 N·s/mF = 25 N
xmax = mm
35.Bode plots & marginsMedium
vin​R = 470 ΩL = 10 mHvout​

The RL high-pass filter shown has R = 470 Ω, L = 10 mH. A sinusoidal input of 15 kHz is applied. Find the phase shift φ of vout relative to vin, in degrees.

R = 470 ΩL = 10 mHf = 15 kHz
φ = °
36.Bode plots & marginsHard
|H| (dB)0.10.1111010100100−80−60−40−2002040ω (rad/s)φ (°)ω (rad/s)−270−180−900ω180​

A unity-feedback loop has the open-loop transfer function L(s) = K/(s(s + 4)(s + 6)). Find the gain K that gives a gain margin of 6 dB.

L(s) = K/(s(s + 4)(s + 6))GM = 6 dB
K =
37.Stability: Routh–Hurwitz & root locusMedium
R(s)+K1(s + 1)(s + 3)(s + 6)C(s)−

A unity-feedback loop has L(s) = K/((s + 1)(s + 3)(s + 6)), with K > 0. Find the largest gain Kmax for which the closed loop is stable.

L(s) = K/((s + 1)(s + 3)(s + 6))
Kmax =
38.Stability: Routh–Hurwitz & root locusHard
ReIm−1−2−3−4−5−6j1−0.5

For the loop L(s) = K/(s(s + 4)(s + 5)), find the gain K that puts a closed-loop pole at s = −0.5.

L(s) = K/(s(s + 4)(s + 5))s = −0.5
K =
39.Steady-state error & PID controlMedium
r(t) = 2t+Ks(s + 1)C(s)−

A unity-feedback loop with G(s) = K/(s(s + 1)) must follow the ramp r(t) = 2t with a steady-state error of 0.1. Find the gain K.

G(s) = K/(s(s + 1))r(t) = 2tess = 0.1
K =
40.Steady-state error & PID controlHard
R(s)+K = 251s(s + 2)C(s)−

A proportional controller K = 25 drives the plant G(s) = 1/(s(s + 2)) in a unity-feedback loop. Find the peak time tp of the step response.

G(s) = 1/(s(s + 2))K = 25
tp = s

3Solutions

1.Series & parallel resistors

Answer: Req = 14.76 Ω

Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.

R1​ = 10 ΩR3​ = 20 Ω+−V1​24 VR2​6 ΩAR4​3 ΩB

Combine resistors from the far end

Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.

R3 + R4 = 20 + 3 = 23 Ω
R2 ∥ 23 = 6·23/(6+23) = 4.759 Ω
Req = R1 + 4.759 = 10 + 4.759 = 14.76 Ω

Answer

Req = 14.76 Ω
2.Series & parallel resistors

Answer: IR1 = 1.222 A

Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.

R1​ = 2 ΩR3​ = 10 ΩR5​ = 15 Ω+−V1​10 VR2​12 ΩAR4​3 ΩBR6​20 Ω

Combine resistors from the far end

Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.

R5 + R6 = 15 + 20 = 35 Ω
R4 ∥ 35 = 2.763 Ω
R3 + 2.763 = 12.76 Ω
R2 ∥ 12.76 = 6.185 Ω
Req = R1 + 6.185 = 2 + 6.185 = 8.185 Ω

Current from the source

The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.

IR1 = V1/Req = 10/8.185 = 1.222 A

Answer

IR1 = 1.222 A
3.Nodal analysis

Answer: VA = 6.353 V

Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.

R1​ = 12 ΩR3​ = 6 Ω+−V1​12 VR2​3 ΩAR4​12 ΩBIs​3 A

Set up the nodes

Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 12 V). Unknowns: VA, VB.

KCL at node A

Currents leaving A through the resistors equal the current pushed into A by sources.

VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/3 + (VA − 12)/12 + (VA − VB)/6 = 0
0.5833·VA − 0.1667·VB = 1

KCL at node B

Currents leaving B through the resistors equal the current pushed into B by sources.

VB/R4 + (VB − VA)/R3 = Is
VB/12 + (VB − VA)/6 = 3
−0.1667·VA + 0.25·VB = 3

Solve

Δ = (0.5833)(0.25) − (−0.1667)(−0.1667) = 0.1181
VA = Δ1/Δ = 0.75/0.1181 = 6.353 V
VB = Δ2/Δ = 1.917/0.1181 = 16.24 V

Answer

VA = 6.353 V
4.Nodal analysis

Answer: IR2 = −0.4762 A

Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.

R1​ = 3 ΩR2​ = 6 ΩR4​ = 6 Ω+−V1​6 VR3​30 ΩAR5​5 ΩBIs​2 A+−V2​12 V

Set up the nodes

Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 6 V, V2 = 12 V). Unknowns: VA, VB.

KCL at node A

Currents leaving A through the resistors equal the current pushed into A by sources.

VA/R3 + (VA − V1)/R1 + (VA − VB)/R2 = 0
VA/30 + (VA − 6)/3 + (VA − VB)/6 = 0
0.5333·VA − 0.1667·VB = 2

KCL at node B

Currents leaving B through the resistors equal the current pushed into B by sources.

VB/R5 + (VB − VA)/R2 + (VB − V2)/R4 = Is
VB/5 + (VB − VA)/6 + (VB − 12)/6 = 2
−0.1667·VA + 0.5333·VB = 4

Solve

Δ = (0.5333)(0.5333) − (−0.1667)(−0.1667) = 0.2567
VA = Δ1/Δ = 1.733/0.2567 = 6.753 V
VB = Δ2/Δ = 2.467/0.2567 = 9.61 V

Answer

IR2 = (VA − VB)/R2 = (6.753 − 9.61)/6 = −0.4762 A
5.Mesh analysis

Answer: I1 = 0.9828 A

Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.

R1​ = 20 ΩR2​ = 10 Ω+−V1​24 VR3​3 ΩA+−V2​9 VI1​I2​

Assign mesh currents

Draw a clockwise current in each window: I1, I2. A resistor shared by two meshes carries the difference of their currents.

KVL around mesh 1

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R1·I1 + R3(I1 − I2) = V1
20·I1 + 3(I1 − I2) = 24
23·I1 − 3·I2 = 24

KVL around mesh 2

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R2·I2 + R3(I2 − I1) = −V2
10·I2 + 3(I2 − I1) = (−9)
−3·I1 + 13·I2 = −9

Solve

Δ = (23)(13) − (−3)(−3) = 290
I1 = Δ1/Δ = 285/290 = 0.9828 A
I2 = Δ2/Δ = −135/290 = −0.4655 A

Answer

I1 = 0.9828 A

A negative mesh current flows anticlockwise.

6.Mesh analysis

Answer: VR4 = 9.297 V

Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.

R1​ = 10 ΩR2​ = 5 ΩR3​ = 8 Ω+−V1​18 VR4​30 ΩAR5​4 ΩB+−V2​15 VI1​I2​I3​

Assign mesh currents

Draw a clockwise current in each window: I1, I2, I3. A resistor shared by two meshes carries the difference of their currents.

KVL around mesh 1

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R1·I1 + R4(I1 − I2) = V1
10·I1 + 30(I1 − I2) = 18
40·I1 − 30·I2 = 18

KVL around mesh 2

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R2·I2 + R4(I2 − I1) + R5(I2 − I3) = 0
5·I2 + 30(I2 − I1) + 4(I2 − I3) = 0
−30·I1 + 39·I2 − 4·I3 = 0

KVL around mesh 3

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R3·I3 + R5(I3 − I2) = −V2
8·I3 + 4(I3 − I2) = (−15)
−4·I2 + 12·I3 = −15

Solve

Δ = det of the coefficient matrix = 7280
I1 = Δ1/Δ = 6336/7280 = 0.8703 A
I2 = Δ2/Δ = 4080/7280 = 0.5604 A
I3 = Δ3/Δ = −7740/7280 = −1.063 A

Answer

IR4 = I1 − I2 = 0.3099 A
VR4 = IR4·R4 = 0.3099·30 = 9.297 V

A negative mesh current flows anticlockwise.

7.Superposition

Answer: IR2 = 1.08 A

Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.

R1​ = 12 ΩR3​ = 5 Ω+−V1​10 VR2​2 ΩAR4​4 ΩBOPEN

Case 1 · V1 acting alone

Iₛ becomes an open circuit, so R₃ and R₄ form one series branch from A to ground, in parallel with R₂.

R3+R4 = 5+4 = 9 Ω
R2 ∥ (R3+R4) = 2·9/(2+9) = 1.636 Ω
VA = 10·1.636/(12+1.636) = 1.2 V
VB = VA·R4/(R3+R4) = 1.2·4/9 = 0.5333 V
IR2′ = (VA − 0)/R2 = (1.2 − 0)/2 = 0.6 A
R1​ = 12 ΩR3​ = 5 ΩSHORTR2​2 ΩAR4​4 ΩBIs​1.5 A

Case 2 · Is acting alone

V₁ becomes a short, so R₁ is in parallel with R₂. Iₛ splits at B between R₄ and the path through R₃.

R1 ∥ R2 = 12·2/(12+2) = 1.714 Ω
Req = R4 ∥ (R3+R1∥R2) = 4 ∥ 6.714 = 2.507 Ω
VB = Is·Req = 1.5·2.507 = 3.76 V
VA = VB·(R1∥R2)/(R3+R1∥R2) = 3.76·1.714/6.714 = 0.96 V
IR2″ = (VA − 0)/R2 = (0.96 − 0)/2 = 0.48 A

Add the contributions

IR2 = IR2′ + IR2″
IR2 = 0.6 + 0.48 = 1.08 A

A negative result means the real current flows against the arrow.

8.Superposition

Answer: PR1 = 0.1022 W

Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.

R1​ = 8 ΩR2​ = 25 ΩR4​ = 12 Ω+−V1​18 VR3​30 ΩAOPENBSHORT

Case 1 · V1 acting alone

V₂ becomes a short and Iₛ an open circuit. Seen from A, R₃ is in parallel with the series pair R₂+R₄.

R3 ∥ (R2+R4) = 30 ∥ 37 = 16.57 Ω
VA = 18·16.57/(8+16.57) = 12.14 V
VB = VA·R4/(R2+R4) = 12.14·12/37 = 3.937 V
IR1′ = (V1 − VA)/R1 = (18 − 12.14)/8 = 0.7327 A
R1​ = 8 ΩR2​ = 25 ΩR4​ = 12 ΩSHORTR3​30 ΩAIs​2 ABSHORT

Case 2 · Is acting alone

Both voltage sources become shorts. Iₛ splits at B between R₄ (now to ground) and R₂ in series with R₁ ∥ R₃.

R1 ∥ R3 = 6.316 Ω, so the left path is R2+6.316 = 31.32 Ω
Req = R4 ∥ 31.32 = 8.676 Ω
VB = Is·Req = 2·8.676 = 17.35 V
VA = VB·6.316/31.32 = 3.499 V
IR1″ = (V1 − VA)/R1 = (0 − 3.499)/8 = −0.4374 A
R1​ = 8 ΩR2​ = 25 ΩR4​ = 12 ΩSHORTR3​30 ΩAOPENB+−V2​10 V

Case 3 · V2 acting alone

V₁ becomes a short and Iₛ an open circuit. R₁ ∥ R₃ hangs from A, in series with R₂ back to B.

R1 ∥ R3 = 8·30/(8+30) = 6.316 Ω
VB = V2·(R2+R1∥R3)/(R4+R2+R1∥R3) = 10·31.32/43.32 = 7.23 V
VA = VB·(R1∥R3)/(R2+R1∥R3) = 7.23·6.316/31.32 = 1.458 V
IR1‴ = (V1 − VA)/R1 = (0 − 1.458)/8 = −0.1823 A

Add the current contributions

IR1 = IR1′ + IR1″ + IR1‴ = 0.7327 + (−0.4374) + (−0.1823) = 0.113 A

Power in the resistor

Power depends on the square of the current, so it does not obey superposition: add the currents first, then square.

PR1 = IR1²·R1 = 0.113²·8 = 0.1022 W

Answer

PR1 = 0.1022 W

Adding the powers of the separate cases would give 6.091 W, which is wrong.

9.Thévenin & Norton

Answer: Rth = 10 Ω

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 10 ΩR3​ = 5 ΩSHORTR2​10 ΩAabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 10·10/(10+10) = 5 Ω
Rth = (R1 ∥ R2) + R3 = 5 + 5 = 10 Ω
10.Thévenin & Norton

Answer: Vth = −28.89 V

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 30 ΩR3​ = 5 ΩSHORTR2​8 ΩAOPENBabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 30·8/(30+8) = 6.316 Ω
Rth = (R1 ∥ R2) + R3 = 6.316 + 5 = 11.32 Ω
R1​ = 30 ΩR3​ = 5 Ω+−V1​24 VR2​8 ΩAIs​3 ABab+−Vth​

Find Vth, the open-circuit voltage

With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.

VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 5.053 + (−3)·6.316 = −13.89 V
Vth = VB = VA + Is·R3 = −13.89 + (−3)·5 = −28.89 V
11.RC & RL transients

Answer: vC = 11.86 V

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Thévenin equivalent seen by the capacitor

Short the source to find Rth; open the capacitor to find the voltage it will settle at.

Rth = R1 ∥ R2 = 1·2.2/(1 + 2.2) = 0.6875 kΩ
vC(∞) = 30·2.2/(1 + 2.2) = 20.63 V

Time constant

τ = Rth·C = 0.6875·68 = 46.75 ms

Charging curve

vC(t) = 20.63·(1 − e−40/46.75) = 11.86 V

Answer

vC = 11.86 V
12.RC & RL transients

Answer: t = 0.4998 ms

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Initial value, final value, time constant

Before t = 0 the closed switch bypasses R₂; afterwards R₁ and R₂ are both in the loop.

i(0) = 10/33 = 0.303 A
i(∞) = 10/(33 + 47) = 0.125 A
τ = L/R = 33/80 = 0.4125 ms
i(t) = 0.125 + (0.303 − 0.125)·e−t/τ

Solve for the time

e−t/τ = (0.178 − 0.125)/(0.303 − 0.125) = 0.2977
t = 0.4125·ln(3.359) = 0.4998 ms

Answer

t = 0.4998 ms
13.AC impedance & phasors

Answer: I = 1.608 A

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactances

ω = 2πf = 2π·200 = 1257 rad/s
XL = ωL = 1257·0.02 = 25.13 Ω
XC = 1/(ωC) = 1/(1257·47·10⁻⁶) = 16.93 Ω

Impedance

In series the impedances add as complex numbers: Z = R + j(XL − XC).

|Z| = √(R² + (XL − XC)²) = √(30² + (8.201)²) = 31.1 Ω

Current

The same current flows through every element of a series circuit.

I = V/|Z| = 50/31.1 = 1.608 A

Answer

I = 1.608 A
14.AC impedance & phasors

Answer: VC = 19.37 V

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactances

ω = 2πf = 2π·60 = 377 rad/s
XL = ωL = 377·0.02 = 7.54 Ω
XC = 1/(ωC) = 1/(377·47·10⁻⁶) = 56.44 Ω

Impedance

In series the impedances add as complex numbers: Z = R + j(XL − XC).

|Z| = √(R² + (XL − XC)²) = √(50² + (−48.9)²) = 69.94 Ω

Current

The same current flows through every element of a series circuit.

I = V/|Z| = 24/69.94 = 0.3432 A

Voltage across the capacitor

VC = I·XC = 0.3432·56.44 = 19.37 V

Answer

VC = 19.37 V
15.AC power & power factor

Answer: I = 96.61 A

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Reactive power of each load

A lagging load takes reactive power (Q > 0); a leading load supplies it (Q < 0).

Q1 = 8·tan(arccos 0.7) = 8.162 kvar
Q2 = −26·tan(arccos 0.7) = −26.53 kvar

Totals

P = 8 + 26 = 34 kW
Q = 8.162 + (−26.53) = −18.36 kvar
S = √(34² + (−18.36)²) = 38.64 kVA

Total current

I = S/V = 38642/400 = 96.61 A

Answer

I = 96.61 A
16.AC power & power factor

Answer: C = 83.28 µF

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Reactive power before and after

The real power P does not change; only the reactive power drawn from the supply does.

Q1 = P·tan φ1 = 5·tan(53.13°) = 6.667 kvar
Q2 = P·tan φ2 = 5·tan(18.19°) = 1.643 kvar
QC = Q1 − Q2 = 5.023 kvar

Capacitance

A capacitor across the supply delivers Q = V²·ωC.

C = QC/(2πf·V²) = 5023/(2π·60·400²) = 83.28 µF

Answer

C = 83.28 µF
17.Three-phase power

Answer: IL = 34.91 A

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.

Electrical input power

Pin = Pout/η = 18.5/0.9 = 20.56 kW

Line current

IL = Pin/(√3·VL·cos φ) = 20556/(√3·400·0.85) = 34.91 A

Answer

IL = 34.91 A
18.Three-phase power

Answer: Cph = 915.6 µF

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.

Reactive power before and after

The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.

Q1 = 200·tan(acos 0.65) = 200·1.169 = 233.8 kvar
Q2 = 200·tan(acos 0.92) = 200·0.426 = 85.2 kvar

Reactive power from the capacitors

QC = Q1 − Q2 = 148.6 kvar

Capacitance per phase

In a Δ bank each capacitor is connected between two lines.

V = 415 V, ω = 2π·50 = 314.2 rad/s
Cph = (QC/3)/(ω·V²) = 49542/(314.2·415²) = 915.6 µF

Answer

Cph = 915.6 µF
19.Transformers

Answer: a = 6

Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.

Match the referred load

a²·8 = 288
a = √(288/8) = √36 = 6

Answer

a = 6
20.Transformers

Answer: Pcu,fl = 2469 W

Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.

Output and input power

Pout = 200·0.85 = 170 kW
Pin = 170000/0.98 = 173469 W

Total and copper losses

Ploss = 173469 − 170000 = 3469 W
Pcu,fl = 3469 − 1000 = 2469 W

Answer

Pcu,fl = 2469 W
21.Op-amp circuits

Answer: Vout = −0.9167 V

Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.

Voltage at the + input

V₊ = Vin·Rb/(Ra + Rb) = −0.5·22/(2 + 22) = −0.4583 V

Non-inverting gain

V₋ = V₊, and the current through R₁ also flows through Rf.

Vout = V₊·(1 + Rf/R1) = −0.4583·(1 + 100/100) = −0.9167 V

Answer

Vout = −0.9167 V
22.Op-amp circuits

Answer: If = −0.0295 mA

Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.

Input currents

V₋ = 0, so each input resistor has its full input voltage across it.

I1 = V1/R1 = −1.6/47 = −0.03404 mA
I2 = V2/R2 = 0.1/22 = 0.004545 mA
If = I1 + I2 = −0.0295 mA

Answer

If = −0.0295 mA
23.Diodes & transistors

Answer: IC = 2.172 mA

BJT bias point: in the active region VBE = 0.7 V, IC = β·IB and IE = (β + 1)·IB. Find IB from the base loop with KVL, then IC, then VCE from the collector–emitter loop. A voltage divider at the base is replaced by its Thévenin equivalent VTH = VCC·R₂/(R₁ + R₂), RTH = R₁∥R₂; an emitter resistor appears (β + 1) times larger in the base loop.

Thévenin equivalent of the divider

VTH = 12·10/(56 + 10) = 1.818 V
RTH = 56·10/(56 + 10) = 8.485 kΩ

Base current

KVL around the base loop; the emitter current is (β + 1)·IB.

IB = (1.818 − 0.7)/(8.485 + 201·0.47) = 10.86 µA

Collector current

IC = 200·10.86 µA = 2.172 mA
IE = 201·10.86 µA = 2.183 mA

Answer

IC = 2.172 mA
24.Diodes & transistors

Answer: IC = 10.21 mA

BJT as a switch: to switch a load fully on, the transistor is driven into saturation, where VCE = VCE(sat) and the collector current is set by the load: IC(sat) = (VCC − VCE(sat))/RC. Saturation needs at least IB = IC(sat)/β. If the base current is smaller, the transistor stays active and IC = β·IB.

Base current

IB = (5 − 0.7)/1 kΩ = 4300 µA

Saturated or active?

β·IB is larger than IC(sat), so the transistor saturates.

β·IB = 860 mA
IC(sat) = (5 − 0.2)/470 = 10.21 mA

Collector current

IC = IC(sat) = 10.21 mA

Answer

IC = 10.21 mA

The transistor is saturated.

25.Number systems

Answer: U = 177

Setting bits: each bit is worth a power of two (128, 64, …, 1). One hex digit is exactly four bits, and in 8-bit two's complement the leftmost bit is worth −128. Bitwise operations work on each bit position separately.

Invert and add one

79 = 0100 1111
inverted: 1011 0000
+1 → 1011 0001

Read it as unsigned

1011 0001₂ = 256 − 79 = 177

Answer

U = 177
26.Number systems

Answer: R = 98

Setting bits: each bit is worth a power of two (128, 64, …, 1). One hex digit is exactly four bits, and in 8-bit two's complement the leftmost bit is worth −128. Bitwise operations work on each bit position separately.

Bit by bit

AND gives 1 only where both bits are 1.

0110 0011
AND 0110 0010
= 0110 0010

Value of the result

0110 0010₂ = 98

Answer

R = 98
27.Digital logic: gates, K-maps & flip-flops

Answer: N = 2

Multiplexer: a 2ⁿ-to-1 multiplexer passes one of its data inputs to the output; the select lines, read as a binary number, pick which one. For a 4-to-1 MUX with selects S₁S₀ = AB, F = A′B′·I₀ + A′B·I₁ + AB′·I₂ + AB·I₃. Tying the data inputs to 0, 1, C or C′ makes the MUX produce any function of A, B and C, which is a common way to build logic with one chip.

Output expression

F = A′B′C′ + A′BC

Rows with F = 1

ABC = 000, 011
N = 2

Answer

N = 2
28.Digital logic: gates, K-maps & flip-flops

Answer: clock edge 6

Flip-flops and counters: a flip-flop changes only at the active clock edge. D copies its input (Q⁺ = D); T toggles when T = 1; JK holds for 00, resets for 01, sets for 10 and toggles for 11. An n-bit binary counter has 2ⁿ states and counts modulo 2ⁿ; a mod-N counter goes 0, 1, …, N − 1 and back to 0, and needs the smallest n with 2ⁿ ≥ N flip-flops. Each stage of a ripple counter halves the frequency, so the last output of a mod-N counter runs at fclk/N. A Johnson counter of n flip-flops has 2n states, a ring counter n.

Q after every edge

A T flip-flop toggles at each rising edge with T = 1 and holds with T = 0.

1: T = 0 → Q = 0
2: T = 1 → Q = 1
3: T = 0 → Q = 1
4: T = 0 → Q = 1
5: T = 0 → Q = 1
6: T = 1 → Q = 0

First change from 1 to 0

clock edge 6

Answer

clock edge 6
29.Laplace transforms

Answer: f(0.75) = 0.7256

Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).

Partial fractions

F(s) = A/s + B/(s + 1) + C/(s + 6)
A = 10/(1·6) = 1.667
B = 10/((−1)·5) = −2
C = 10/((−6)·(−5)) = 0.3333

Inverse transform

f(t) = 1.667 − 2·e−t + 0.3333·e−6t

Evaluate

f(0.75) = 1.667 − 2·e−0.75 + 0.3333·e−6·0.75 = 0.7256

Answer

f(0.75) = 0.7256
30.Laplace transforms

Answer: y(0.25) = 1.392

Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).

Transform the equation

Y(s) = 90/(s(s + 3)(s + 6))

Partial fractions

A = 90/(3·6) = 5
B = 90/((−3)·3) = −10
C = 90/((−6)·(−3)) = 5

Output

y(t) = 5 − 10·e−3t + 5·e−6t
y(0.25) = 1.392

Answer

y(0.25) = 1.392
31.Block diagrams

Answer: K = 6.25

Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).

Characteristic equation

1 + K/((s + 5)(s + 10)) = 0 → s² + 15s + 50 + K = 0

Repeated root

A quadratic s² + βs + γ has a double root when β² = 4γ.

15² = 4(50 + K) → K = 225/4 − 50 = 6.25

Answer

K = 6.25
Both closed-loop poles are then at s = −7.5.
32.Block diagrams

Answer: σ = −5.5

Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).

Characteristic equation

s(s + 11) + 22·2 = 0 → s² + 11s + 44 = 0

Roots

s = −5.5 ± j·√(44 − 30.25) = −5.5 ± j3.708
σ = −5.5

Answer

σ = −5.5
33.Step response

Answer: ts = 8 s

Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).

Compare with the standard form

The denominator must match s² + 2ζωₙs + ωₙ².

ωₙ² = 16 → ωₙ = 4 rad/s
2ζωₙ = 1 → ζ = 1/(2·4) = 0.125

Result

ζωₙ = 0.5 → ts ≈ 4/0.5 = 8 s

Answer

ts = 8 s
34.Step response

Answer: xmax = 428.8 mm

Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).

Natural frequency and damping ratio

ωₙ = √(k/m) = √(100/2) = 7.071 rad/s
ζ = c/(2√(km)) = 3/(2·√(100·2)) = 0.1061

Result

xst = F/k = 25/100 m = 250 mm
%OS = 71.53 %
xmax = 250·(1 + 0.7153) = 428.8 mm

Answer

xmax = 428.8 mm
35.Bode plots & margins

Answer: φ = 26.5 °

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Corner frequency

ωc = R/L = 470/0.01 = 47000 rad/s
fc = 7480 Hz → f/fc = 15000/7480 = 2.005

Phase

φ = 90° − atan(2.005) = 26.5°

Answer

φ = 26.5°
36.Bode plots & margins

Answer: K = 120.3

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Phase crossover

(ω/4)·(ω/6) = 1 → ω180 = √(4·6) = 4.899 rad/s

Magnitude at phase crossover

|L(jω180)| = K/(ω·√(ω² + 16)·√(ω² + 36)) = K/(4·6·(4 + 6)) = K/240

Required gain

240/K = 106/20 = 1.995
K = 240/1.995 = 120.3

Answer

K = 120.3
37.Stability: Routh–Hurwitz & root locus

Answer: Kmax = 252

Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.

Characteristic polynomial

s³ + 10s² + 27s + 18 + K = 0

Routh array

s³: 1, 27
s²: 10, 18 + K
s¹: (10·27 − 18 − K)/10
s⁰: 18 + K

Condition

The s¹ entry must stay positive.

K < 10·27 − 18 = 252

Answer

Kmax = 252

At the limit the loop oscillates at ω = √27 = 5.196 rad/s.

38.Stability: Routh–Hurwitz & root locus

Answer: K = 7.875

Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.

Magnitude condition

K = |s|·|s + 4|·|s + 5|

Evaluate at the point

K = 0.5·3.5·4.5 = 7.875

Answer

K = 7.875

Check: s(s + 4)(s + 5) + K is zero at s = −0.5.

39.Steady-state error & PID control

Answer: K = 20

Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.

Required velocity constant

Kv = A/ess = 2/0.1 = 20

Gain

K = 1·Kv = 20

Answer

K = 20

A large gain makes this loop very lightly damped: ζ = 0.1118. That conflict is why compensators are used.

40.Steady-state error & PID control

Answer: tp = 0.6413 s

P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).

Characteristic polynomial

s(s + 2) + 25·1 = s² + 2s + 25

ωₙ and ζ

ωₙ = √25 = 5 rad/s
ζ = 2/(2·5) = 0.2

Peak time

ωd = 5·√(1 − 0.2²) = 4.899 rad/s
tp = π/4.899 = 0.6413 s

Answer

tp = 0.6413 s

This is independent practice material. ExamProblems is not affiliated with or endorsed by the organisation that runs this exam, and the exam name is used only to describe the content. The FE exam is run by NCEES, which is not affiliated with ExamProblems and does not endorse it.

ExamProblems · examproblems.com/courses/fe-exam-electrical