FE Electrical and Computer exam practice: cram pack

Formula sheets, the key method steps for every topic and 40 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

Series & parallel resistors

Resistors in series
Req = R1 + R2 + …
Resistors in parallel
1/Req = 1/R1 + 1/R2 + …
Two in parallel
Req = R1R2 / (R1 + R2)
Ohm's law
V = I·R
Power
P = V·I = I²R = V²/R

Method

  1. Start at the end of the network furthest from the terminals.
  2. Combine resistors in series by adding them, and resistors in parallel with 1/R = 1/R₁ + 1/R₂ + …
  3. Redraw the circuit after each step.
  4. Repeat until one resistor is left between the terminals.

Nodal analysis

Kirchhoff’s current law
ΣIin = ΣIout
Branch current
I = (Va − Vb)/R
Reference node
Vground = 0

Method

  1. Choose a reference node (ground) and label the other node voltages.
  2. Write Kirchhoff’s current law at every unknown node: currents leaving through each branch equal the currents entering.
  3. Express every branch current as (Va − Vb)/R.
  4. Solve the system of equations, then find any current you need.

Mesh analysis

Kirchhoff’s voltage law
ΣV = 0 around every loop
Shared resistor
current = I1 − I2
Current source in a mesh
fixes that mesh current

Method

  1. Draw a clockwise current in every mesh (window) of the circuit.
  2. Apply Kirchhoff’s voltage law around each mesh: the sum of voltage drops is zero.
  3. In a resistor shared by two meshes the current is the difference of the two mesh currents.
  4. Solve the equations; a negative result means the current flows the other way.

Superposition

Superposition
x = x1 + x2 + … (one source at a time)
Switched-off voltage source
short circuit (0 V)
Switched-off current source
open circuit (0 A)
Voltage divider
V2 = V·R2/(R1 + R2)
Current divider
I1 = I·R2/(R1 + R2)

Method

  1. Count the independent sources. You will solve one simpler circuit per source.
  2. Keep one source and switch off the others: a voltage source becomes a short circuit (a wire), a current source becomes an open circuit (a gap).
  3. Solve the simpler circuit for the voltage or current you need, keeping track of its direction.
  4. Repeat for every source, then add the contributions with their signs.

Thévenin & Norton

Thévenin voltage
Vth = Vopen circuit
Thévenin resistance
Rth: all sources off, seen from a–b
Norton current
IN = Vth/Rth
Load current
IL = Vth/(Rth + RL)
Maximum power transfer
RL = Rth, Pmax = Vth²/(4Rth)

Method

  1. Remove the load and mark the two terminals a and b.
  2. Find the open-circuit voltage between a and b: this is Vth.
  3. Switch off all independent sources and find the resistance seen from a–b: this is Rth.
  4. Put the load back on the equivalent circuit: Vth in series with Rth.
  5. For the Norton equivalent, convert: IN = Vth/Rth, with RN = Rth in parallel.

RC & RL transients

Time constant
τ = RC | τ = L/R
Response
x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ
Capacitor at DC
open circuit; vC cannot jump
Inductor at DC
short circuit; iL cannot jump
Settled
t ≈ 5τ

Method

  1. Find the initial value just after switching: a capacitor voltage and an inductor current cannot jump.
  2. Find the final value long after switching: a capacitor acts as an open circuit, an inductor as a short circuit.
  3. Find the time constant: τ = RC or τ = L/R, using the resistance seen by the capacitor or inductor.
  4. Use x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ.

AC impedance & phasors

Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z

Method

  1. Convert the frequency: ω = 2πf.
  2. Find each reactance: XL = ωL and XC = 1/(ωC).
  3. Add impedances like resistors, with Z = R + jX.
  4. Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.

AC power & power factor

Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)

Three-phase power

Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η

Transformers

Turns ratio
a = N1/N2 = V1/V2
Current ratio
I1/I2 = N2/N1 = 1/a
Rated current
I = S/V
Referred impedance
Z1′ = a²·ZL
Copper loss at part load
Pcu = x²·Pcu,fl
Efficiency
η = x·S·pf/(x·S·pf + Pcore + x²·Pcu,fl)
Maximum efficiency
x = √(Pcore/Pcu,fl)

Op-amp circuits

Inverting amplifier
Vout = −(Rf/Rin)·Vin
Non-inverting amplifier
Vout = (1 + Rf/R1)·Vin
Summing amplifier
Vout = −Rf(V1/R1 + V2/R2)
Ideal op-amp
V+ = V−, Iin = 0

Diodes & transistors

Diode (constant drop)
VD = 0.7 V when conducting
Active region
VBE = 0.7 V, IC = β·IB, IE = (β + 1)·IB
Fixed bias
IB = (VCC − 0.7)/RB
Divider bias
IB = (VTH − 0.7)/(RTH + (β + 1)RE)
Thévenin of the divider
VTH = VCC·R2/(R1 + R2), RTH = R1∥R2
Collector loop
VCE = VCC − ICRC − IERE
Saturation
IC(sat) = (VCC − VCE(sat))/RC, IB ≥ IC(sat)/β

Number systems

Place values
binary 2k, octal 8k, hex 16k
To decimal
Σ dk·bk
From decimal
divide by the base, read the remainders bottom-up
Hex ↔ binary
one hex digit = 4 bits
Two’s complement
invert the bits and add 1

Digital logic: gates, K-maps & flip-flops

Basic gates
A·B, A + B, A′, (A·B)′, (A + B)′, A ⊕ B
Boolean rules
X + X′ = 1, X·X′ = 0, X + XY = X, XY + XY′ = X
De Morgan
(X·Y)′ = X′ + Y′, (X + Y)′ = X′·Y′
Karnaugh map order
00, 01, 11, 10 (Gray code)
Group of 2ᵏ cells
loses k variables
4-to-1 multiplexer
F = A′B′I0 + A′BI1 + AB′I2 + ABI3
Flip-flops
D: Q⁺ = D, T: Q⁺ = T ⊕ Q, JK: Q⁺ = JQ′ + K′Q
Counters
n-bit: 2ⁿ states; mod-N: smallest n with 2ⁿ ≥ N; fout = fclk/N
Ripple counter
fmax = 1/(n·tpd)
Ring and Johnson counters
n and 2n states

Method

  1. For a circuit, work from the inputs to the output one gate at a time and write the value on every wire, or write its expression and fill in the truth table.
  2. For simplification, put the 1s (and the don’t-cares as X) into a Karnaugh map with Gray-code rows and columns: 00, 01, 11, 10.
  3. Cover the 1s with as few and as large groups of 1, 2, 4, 8 or 16 cells as possible, wrapping round the edges; each group is one product term made of the variables that stay constant. Group the 0s for the POS form.
  4. For flip-flops and counters, read the inputs at each active clock edge, write the state after every edge, and remember that an n-bit counter wraps round after 2ⁿ states.

Stability: Routh–Hurwitz & root locus

Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)

Method

  1. Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
  2. Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
  3. Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
  4. For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.

Steady-state error & PID control

System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)

Method

  1. Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
  2. Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
  3. Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
  4. For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².

2Practice problems

1.Series & parallel resistorsMedium
R1​ = 8 ΩIR1​R3​ = 15 Ω+−V1​6 VR2​5 ΩAR4​4 ΩB

Find the current IR1 delivered by the source, which flows through R1.

V1 = 6 VR1 = 8 ΩR2 = 5 ΩR3 = 15 ΩR4 = 4 Ω
IR1 = A
2.Series & parallel resistorsHard
R1​ = 6 ΩR3​ = 25 ΩR5​ = 25 Ω+−V1​18 VR2​5 ΩAR4​3 ΩBR6​4 Ω

Find the equivalent resistance Req seen by the source V1.

V1 = 18 VR1 = 6 ΩR2 = 5 ΩR3 = 25 ΩR4 = 3 ΩR5 = 25 ΩR6 = 4 Ω
Req = Ω
3.Nodal analysisMedium
R1​ = 8 ΩIR1​R3​ = 2 Ω+−V1​12 VR2​15 ΩAR4​15 ΩBIs​2 A

Use nodal analysis to find the current IR1 through R1 in the direction of the arrow.

V1 = 12 VIs = 2 AR1 = 8 ΩR2 = 15 ΩR3 = 2 ΩR4 = 15 Ω
IR1 = A
4.Nodal analysisHard
R1​ = 2 ΩR3​ = 4 Ω+−V1​15 VR2​20 ΩAR4​5 ΩB0.5·VA​

The diamond is a voltage-controlled current source that pushes a current of 0.5·VA (in A, with VA in V) up into node B. Use nodal analysis to find the node voltage VA (measured from ground).

V1 = 15 VR1 = 2 ΩR2 = 20 ΩR3 = 4 ΩR4 = 5 Ωg = 0.5 A/V
VA = V
5.Mesh analysisMedium
R1​ = 12 ΩR2​ = 3 Ω+−V1​6 VR3​6 ΩA+−V2​12 VI1​I2​

Use mesh analysis to find the mesh current I2 (clockwise).

V1 = 6 VV2 = 12 VR1 = 12 ΩR2 = 3 ΩR3 = 6 Ω
I2 = A
6.Mesh analysisHard
R1​ = 2 ΩIR1​R2​ = 30 ΩR3​ = 30 Ω+−V1​30 VR4​15 ΩAR5​25 ΩB+−V2​36 VI1​I2​I3​

Use mesh analysis to find the current IR1 through R1 in the direction of the arrow.

V1 = 30 VV2 = 36 VR1 = 2 ΩR2 = 30 ΩR3 = 30 ΩR4 = 15 ΩR5 = 25 Ω
IR1 = A
7.SuperpositionMedium
linear circuitVs​Is​IRL​

A linear resistive circuit contains one voltage source Vs and one current source Is. The current I through a load resistor is measured twice: with Vs = 20 V and Is = 5 mA, I = 33 mA; with Vs = 6 V and Is = 8 mA, I = 13.8 mA. Find the load current I when Vs = 8 V and Is = 6 mA.

20 V, 5 mA → 33 mA6 V, 8 mA → 13.8 mAVs = 8 V, Is = 6 mA
I = mA
8.SuperpositionHard
R1​ = 6 ΩR2​ = 2 ΩR4​ = 15 Ω+−V1​24 VR3​8 ΩIR3​AIs​6 AB+−V2​?

Find the value of the voltage source V2 (polarity as shown) that makes the current IR3 through R3 equal to zero.

V1 = 24 VIs = 6 AR1 = 6 ΩR2 = 2 ΩR3 = 8 ΩR4 = 15 Ω
V2 = V
9.Thévenin & NortonMedium
R1​ = 4 ΩR3​ = 20 Ω+−V1​15 VR2​12 ΩAab

Find the Thévenin resistance Rth seen from terminals a–b.

V1 = 15 VR1 = 4 ΩR2 = 12 ΩR3 = 20 Ω
Rth = Ω
10.Thévenin & NortonHard
R1​ = 15 ΩR3​ = 20 Ω+−V1​5 VR2​15 ΩAIs​1 ABab

Find the Thévenin voltage Vth seen from terminals a–b.

V1 = 5 VIs = 1 AR1 = 15 ΩR2 = 15 ΩR3 = 20 Ω
Vth = V
11.RC & RL transientsMedium
R = 68 Ωt = 0L10 mHi(t)

The inductor carries a steady current of 0.5 A. At t = 0 the switch closes the loop through R and the source is removed, so the inductor current decays through R. Find the current i at t = 1 ms.

i(0) = 0.5 AR = 68 ΩL = 10 mHt = 1 ms
i = A
12.RC & RL transientsHard
+−Vs​12 Vt = 0R = ?C10 µF+−vC​

A timer starts charging an uncharged capacitor through a resistor from a 12 V supply at t = 0. It must trigger when the capacitor voltage reaches 7.2 V, exactly 20 ms after the start. With C = 10 µF, find the resistance R needed.

Vs = 12 VVth = 7.2 VT = 20 msC = 10 µF
R = kΩ
13.AC impedance & phasorsMedium
100 V500 HzR = 25 ΩL = 250 mHC = 1 µF

A series RLC circuit is connected to a 100 V (rms), 500 Hz supply. Find the phase angle φ of the impedance, in degrees (positive when the current lags the voltage).

V = 100 V (rms)f = 500 HzR = 25 ΩL = 250 mHC = 1 µF
φ = °
14.AC impedance & phasorsHard
VfR = 15 ΩL = 10 mHC = 2.2 µF

A series RLC circuit has R = 15 Ω, L = 10 mH and C = 2.2 µF. Find its bandwidth B (the width of the band between the half-power frequencies), in Hz.

R = 15 ΩL = 10 mHC = 2.2 µF
B = Hz
15.AC power & power factorMedium
P = 18 kWQ = ?Sφ

A single-phase motor takes 18 kW at a power factor of 0.7 lagging from a 230 V supply. Find the reactive power Q it draws.

P = 18 kWpf = 0.7V = 230 V
Q = kvar
16.AC power & power factorHard
P = 20 kWQ1​S1​φ1​QC​

A single-phase load takes 20 kW at a power factor of 0.75 lagging from a 230 V, 60 Hz supply. A capacitor connected in parallel raises the power factor to 0.98. Find the reactive power QC the capacitor must supply.

P = 20 kWpf1 = 0.75pf2 = 0.98V = 230 Vf = 60 Hz
QC = kvar
17.Three-phase powerMedium
ABCVL​ = 208 VIL​ = 75 Acos φ = 0.85lagging

A balanced three-phase load draws a line current of 75 A from a supply with a line-to-line voltage of 208 V. The power factor is 0.85 lagging. Find the total real power P drawn by the load in kW.

VL = 208 VIL = 75 Acos φ = 0.85
P = kW
18.Three-phase powerHard
P = 100 kWφ1​S1​Q2​QC​

A balanced three-phase load takes 100 kW at a power factor of 0.65 lagging from a 400 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.95 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.

P = 100 kWpf1 = 0.65pf2 = 0.95VL = 400 Vf = 50 Hz
Cph = µF
19.TransformersMedium
50 Ω61

A 50 Ω resistor is connected across the secondary winding of an ideal transformer with a turns ratio N₁:N₂ = 6:1. Find the resistance R1′ seen looking into the primary winding.

N1:N2 = 6:1RL = 50 Ω
R1′ = Ω
20.TransformersHard
pf 0.925 kVA, η = 98%

A single-phase 25 kVA transformer has a core loss of 125 W. At rated load and a power factor of 0.9 lagging its efficiency is 98%. Find the full-load copper loss Pcu,fl in watts.

S = 25 kVAPcore = 125 Wpf = 0.9η = 98%
Pcu,fl = W
21.Op-amp circuitsMedium
−+Vout​Rf​ = ?R1​ = 10 kΩVin​

Choose the feedback resistor Rf that gives this non-inverting amplifier a voltage gain of 20.

R1 = 10 kΩAv = 20
Rf = kΩ
22.Op-amp circuitsHard
−+Vout​Rf​ = 4.7 kΩV1​ = 1.7 VR1​ = 1 kΩV2​ = 1.1 VR2​ = 10 kΩ

The summing amplifier uses an ideal op-amp with ±15 V supplies. Find the output voltage Vout.

V1 = 1.7 VV2 = 1.1 VR1 = 1 kΩR2 = 10 kΩRf = 4.7 kΩ
Vout = V
23.Diodes & transistorsMedium
+−12 VR = ?3 × 3 V5 mA

3 white LEDs (forward voltage 3 V each) are connected in series with a resistor to a 12 V supply. Find the resistance R that sets the current to 5 mA.

Vs = 12 VVF = 3 Vn = 3I = 5 mA
R = Ω
24.Diodes & transistorsHard
V (V)I (mA)0.61212Q = ?

A diode is modelled as 0.6 V in series with 25 Ω (it conducts above 0.6 V). It is in series with a 1000 Ω resistor across a 12 V supply. Find the operating current ID where the diode line meets the load line.

Vs = 12 VR = 1000 ΩV0 = 0.6 Vrd = 25 Ω
ID = mA
25.Number systemsMedium
8-bit two's complement0−12806403201608040201

Set the bits so they store −43 in 8-bit two's complement. Read as an unsigned number, what is the pattern's value U?

N = −438 bit
U =
26.Number systemsHard
32-bit two's complement, N = ??sign???????????????????????????????

What is the most negative integer N that can be stored in 32-bit two's complement?

32 bit
N =
27.Digital logic: gates, K-maps & flip-flopsMedium
ABCD000111100001111000010312140507060120131151140809111110

Use the Karnaugh map to find the minimal sum-of-products (SOP) form of F(A, B, C, D) = Σm(2, 4, 10, 11, 14, 15). How many literals L does it contain in total (a primed variable counts as one literal)?

F(A, B, C, D) = Σm(2, 4, 10, 11, 14, 15)
L =
28.Digital logic: gates, K-maps & flip-flopsHard
ABCD000111100001111000X1X3X2041517060121130151140809011110

Find the minimal SOP form of F(A, B, C, D) = Σm(5, 7, 10, 13, 14) + d(1, 2, 3), where d marks the don't-care conditions. How many literals L does it contain?

F(A, B, C, D) = Σm(5, 7, 10, 13, 14) + d(1, 2, 3)
L =
29.Laplace transformsMedium
ReIm−5−10−15−20−25

Find f(t) for F(s) = (s + 26)/(s² + 8s + 17) by completing the square, and evaluate f(0.5).

F(s) = (s + 26)/(s² + 8s + 17)t = 0.5 s
f(0.5) =
30.Laplace transformsHard
ReIm−1−2−3−4−5−612

A system is described by the differential equation y″ + 6y′ + 13y = u′ + 6u, with input u(t) and output y(t). Find its transfer function G(s) = Y(s)/U(s) (zero initial conditions) and evaluate the impulse response g(t) at t = 0.3 s. Find g(0.3).

y″ + 6y′ + 13y = u′ + 6ut = 0.3 s
g(0.3) =
31.Block diagramsMedium
R(s)+4K+10s + 4G(s)C(s)5H₁−−

The plant G(s) = 10/(s + 4) has an inner (minor) negative feedback loop with gain H₁ = 5. A controller gain K = 4 and an outer unity negative feedback loop close the system. Find the closed-loop DC gain T(0).

G(s) = 10/(s + 4)H₁ = 5K = 4
T(0) =
32.Block diagramsHard
R(s)+10s(s + 4)G(s)C(s)2H−

The plant G(s) = 10/(s(s + 4)) is in a negative feedback loop with sensor gain H = 2. The closed-loop poles are complex. Find their imaginary part ωd (the positive value), in rad/s.

G(s) = 10/(s(s + 4))H = 2
ωd = rad/s
33.Step responseMedium
t (s)y(t)1tp​ = ?

A system has the transfer function G(s) = 65/(s² + 4s + 65) and receives a unit step input. Find the peak time tp of the step response.

G(s) = 65/(s² + 4s + 65)
tp = s
34.Step responseHard
+−5 VR = 88 ΩL = 100 mHC = 4.7 µFvC​

A series RLC circuit with R = 88 Ω, L = 100 mH and C = 4.7 µF is connected to a 5 V step at t = 0. The capacitor is uncharged and no current flows before the step. Find the undamped natural frequency ωn in rad/s.

R = 88 ΩL = 100 mHC = 4.7 µFV = 5 V
ωn = rad/s
35.Bode plots & marginsMedium
vin​L = 20 mHC = 4.7 µFR = 20 Ωvout​

In the series RLC band-pass filter shown the output is taken across R = 20 Ω, with L = 20 mH and C = 4.7 µF. Find the −3 dB bandwidth BW in Hz.

R = 20 ΩL = 20 mHC = 4.7 µF
BW = Hz
36.Bode plots & marginsHard
|H| (dB)0.10.1111010100100−80−60−40−2002040ω (rad/s)φ (°)ω (rad/s)−270−180−900ω180​

A unity-feedback loop has the open-loop transfer function L(s) = K/(s(s + 3)(s + 5)). Find the gain K that gives a gain margin of 15 dB.

L(s) = K/(s(s + 3)(s + 5))GM = 15 dB
K =
37.Stability: Routh–Hurwitz & root locusMedium
R(s)+4801s(s + 4)(s + 6)C(s)−

The loop in the diagram has negative feedback and L(s) = 480/(s(s + 4)(s + 6)). How many closed-loop poles N lie in the right half-plane?

L(s) = 480/(s(s + 4)(s + 6))
N =
38.Stability: Routh–Hurwitz & root locusHard
ReIm−1−2−3−4−5−6−71j1j2

A unity-feedback loop has L(s) = K(s + 4)/(s(s + 6)(s + 3)). Find the point σa where the asymptotes of the root locus cross the real axis.

L(s) = K(s + 4)/(s(s + 6)(s + 3))
σa =
39.Steady-state error & PID controlMedium
R(s)+K = 2510s + 1C(s)−

A process G(s) = 5/(10s + 1) is controlled by a proportional gain K = 2 in a unity-feedback loop. Find the steady-state error ess for a step, as a percentage of the step size.

G(s) = 5/(10s + 1)K = 2
ess = %
40.Steady-state error & PID controlHard
R(s)+K = 52s(s + 5)C(s)−

A proportional controller K = 5 drives the plant G(s) = 2/(s(s + 5)) in a unity-feedback loop. Find the percent overshoot %OS of the step response.

G(s) = 2/(s(s + 5))K = 5
%OS = %

3Solutions

1.Series & parallel resistors

Answer: IR1 = 0.5017 A

Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.

R1​ = 8 ΩR3​ = 15 Ω+−V1​6 VR2​5 ΩAR4​4 ΩB

Combine resistors from the far end

Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.

R3 + R4 = 15 + 4 = 19 Ω
R2 ∥ 19 = 5·19/(5+19) = 3.958 Ω
Req = R1 + 3.958 = 8 + 3.958 = 11.96 Ω

Current from the source

The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.

IR1 = V1/Req = 6/11.96 = 0.5017 A

Answer

IR1 = 0.5017 A
2.Series & parallel resistors

Answer: Req = 10.24 Ω

Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.

R1​ = 6 ΩR3​ = 25 ΩR5​ = 25 Ω+−V1​18 VR2​5 ΩAR4​3 ΩBR6​4 Ω

Combine resistors from the far end

Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.

R5 + R6 = 25 + 4 = 29 Ω
R4 ∥ 29 = 2.719 Ω
R3 + 2.719 = 27.72 Ω
R2 ∥ 27.72 = 4.236 Ω
Req = R1 + 4.236 = 6 + 4.236 = 10.24 Ω

Answer

Req = 10.24 Ω
3.Nodal analysis

Answer: IR1 = −0.1292 A

Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.

R1​ = 8 ΩR3​ = 2 Ω+−V1​12 VR2​15 ΩAR4​15 ΩBIs​2 A

Set up the nodes

Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 12 V). Unknowns: VA, VB.

KCL at node A

Currents leaving A through the resistors equal the current pushed into A by sources.

VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/15 + (VA − 12)/8 + (VA − VB)/2 = 0
0.6917·VA − 0.5·VB = 1.5

KCL at node B

Currents leaving B through the resistors equal the current pushed into B by sources.

VB/R4 + (VB − VA)/R3 = Is
VB/15 + (VB − VA)/2 = 2
−0.5·VA + 0.5667·VB = 2

Solve

Δ = (0.6917)(0.5667) − (−0.5)(−0.5) = 0.1419
VA = Δ1/Δ = 1.85/0.1419 = 13.03 V
VB = Δ2/Δ = 2.133/0.1419 = 15.03 V

Answer

IR1 = (V1 − VA)/R1 = (12 − 13.03)/8 = −0.1292 A
4.Nodal analysis

Answer: VA = 19.57 V

Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.

KCL at node A

Currents leaving A through the resistors equal the current pushed into A by sources.

(VA − V1)/R1 + VA/R2 + (VA − VB)/R3 = 0
0.8·VA − 0.25·VB = 7.5

KCL at node B

The dependent source pushes g·VA into node B. Treat it like an independent source, then move the VA term to the left-hand side.

(VB − VA)/R3 + VB/R4 = 0.5·VA
−0.75·VA + 0.45·VB = 0

Solve

Δ = (0.8)(0.45) − (−0.25)(−0.75) = 0.1725
VA = Δ1/Δ = 3.375/0.1725 = 19.57 V
VB = Δ2/Δ = 5.625/0.1725 = 32.61 V

Answer

VA = 19.57 V
5.Mesh analysis

Answer: I2 = −1.429 A

Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.

R1​ = 12 ΩR2​ = 3 Ω+−V1​6 VR3​6 ΩA+−V2​12 VI1​I2​

Assign mesh currents

Draw a clockwise current in each window: I1, I2. A resistor shared by two meshes carries the difference of their currents.

KVL around mesh 1

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R1·I1 + R3(I1 − I2) = V1
12·I1 + 6(I1 − I2) = 6
18·I1 − 6·I2 = 6

KVL around mesh 2

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R2·I2 + R3(I2 − I1) = −V2
3·I2 + 6(I2 − I1) = (−12)
−6·I1 + 9·I2 = −12

Solve

Δ = (18)(9) − (−6)(−6) = 126
I1 = Δ1/Δ = −18/126 = −0.1429 A
I2 = Δ2/Δ = −180/126 = −1.429 A

Answer

I2 = −1.429 A

A negative mesh current flows anticlockwise.

6.Mesh analysis

Answer: IR1 = 1.961 A

Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.

R1​ = 2 ΩR2​ = 30 ΩR3​ = 30 Ω+−V1​30 VR4​15 ΩAR5​25 ΩB+−V2​36 VI1​I2​I3​

Assign mesh currents

Draw a clockwise current in each window: I1, I2, I3. A resistor shared by two meshes carries the difference of their currents.

KVL around mesh 1

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R1·I1 + R4(I1 − I2) = V1
2·I1 + 15(I1 − I2) = 30
17·I1 − 15·I2 = 30

KVL around mesh 2

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R2·I2 + R4(I2 − I1) + R5(I2 − I3) = 0
30·I2 + 15(I2 − I1) + 25(I2 − I3) = 0
−15·I1 + 70·I2 − 25·I3 = 0

KVL around mesh 3

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R3·I3 + R5(I3 − I2) = −V2
30·I3 + 25(I3 − I2) = (−36)
−25·I2 + 55·I3 = −36

Solve

Δ = det of the coefficient matrix = 42450
I1 = Δ1/Δ = 83250/42450 = 1.961 A
I2 = Δ2/Δ = 9450/42450 = 0.2226 A
I3 = Δ3/Δ = −23490/42450 = −0.5534 A

Answer

IR1 = I1 = 1.961 A

A negative mesh current flows anticlockwise.

7.Superposition

Answer: I = 15.6 mA

Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.

Write the response as a sum of contributions

Each contribution is proportional to its own source, with a constant that depends only on the resistors.

I = k₁·Vs + k₂·Is
20·k₁ + 5·k₂ = 33
6·k₁ + 8·k₂ = 13.8

Solve for the constants

Δ = (20)(8) − (5)(6) = 130
k₁ = Δ1/Δ = 195/130 = 1.5
k₂ = Δ2/Δ = 78/130 = 0.6
k₁ = 1.5 mA/V, k₂ = 0.6

Predict the new current

I = 1.5·8 + 0.6·6 = 15.6 mA

Answer

I = 15.6 mA
8.Superposition

Answer: V2 = 22 V

Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.

R1​ = 6 ΩR2​ = 2 ΩR4​ = 15 Ω+−V1​24 VR3​8 ΩAOPENBSHORT

Case 1 · V1 acting alone

V₂ becomes a short and Iₛ an open circuit. Seen from A, R₃ is in parallel with the series pair R₂+R₄.

R3 ∥ (R2+R4) = 8 ∥ 17 = 5.44 Ω
VA = 24·5.44/(6+5.44) = 11.41 V
VB = VA·R4/(R2+R4) = 11.41·15/17 = 10.07 V
R1​ = 6 ΩR2​ = 2 ΩR4​ = 15 ΩSHORTR3​8 ΩAIs​6 ABSHORT

Case 2 · Is acting alone

Both voltage sources become shorts. Iₛ splits at B between R₄ (now to ground) and R₂ in series with R₁ ∥ R₃. The arrow of Iₛ points down, away from its node, so Iₛ draws current out of that node: its term enters with a minus sign.

R1 ∥ R3 = 3.429 Ω, so the left path is R2+3.429 = 5.429 Ω
Req = R4 ∥ 5.429 = 3.986 Ω
VB = −Is·Req = −6·3.986 = −23.92 V
VA = VB·3.429/5.429 = −15.1 V

Case 3 · V2 acting alone, per volt

V₁ becomes a short and Iₛ an open circuit. R₁ ∥ R₃ hangs from A, in series with R₂ back to B.

R1 ∥ R3 = 3.429 Ω
VA‴ = V2·3.429/(15 + 2 + 3.429) = 0.1678·V2

Set VA to zero

With VA = 0 there is no voltage across R₃, so its current is zero.

VA′ + VA″ + VA‴ = 11.41 + (−15.1) + 0.1678·V2 = 0
V2 = 3.692/0.1678 = 22 V

Answer

V2 = 22 V
9.Thévenin & Norton

Answer: Rth = 23 Ω

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 4 ΩR3​ = 20 ΩSHORTR2​12 ΩAabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 4·12/(4+12) = 3 Ω
Rth = (R1 ∥ R2) + R3 = 3 + 20 = 23 Ω
10.Thévenin & Norton

Answer: Vth = 30 V

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 15 ΩR3​ = 20 ΩSHORTR2​15 ΩAOPENBabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 15·15/(15+15) = 7.5 Ω
Rth = (R1 ∥ R2) + R3 = 7.5 + 20 = 27.5 Ω
R1​ = 15 ΩR3​ = 20 Ω+−V1​5 VR2​15 ΩAIs​1 ABab+−Vth​

Find Vth, the open-circuit voltage

With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.

VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 2.5 + 1·7.5 = 10 V
Vth = VB = VA + Is·R3 = 10 + 1·20 = 30 V
11.RC & RL transients

Answer: i = 0.0005569 A

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Time constant

τ = L/R = 10 mH / 68 Ω = 0.1471 ms

Decay of the current

i(t) = 0.5·e−1/0.1471 = 0.0005569 A

Answer

i = 0.0005569 A
12.RC & RL transients

Answer: R = 2.183 kΩ

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Required time constant

7.2 = 12·(1 − e−20/τ) → τ = 20/ln(12/(12 − 7.2))
τ = 20/0.9163 = 21.83 ms

Resistance

kΩ times µF gives milliseconds.

R = τ/C = 21.83/10 = 2.183 kΩ

Answer

R = 2.183 kΩ
13.AC impedance & phasors

Answer: φ = 86.94 °

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactances

ω = 2πf = 2π·500 = 3142 rad/s
XL = ωL = 3142·0.25 = 785.4 Ω
XC = 1/(ωC) = 1/(3142·1·10⁻⁶) = 318.3 Ω

Impedance

In series the impedances add as complex numbers: Z = R + j(XL − XC).

|Z| = √(R² + (XL − XC)²) = √(25² + (467.1)²) = 467.8 Ω

Phase angle

φ = arctan((XL − XC)/R) = arctan(467.1/25) = 86.94°

Answer

φ = 86.94°
14.AC impedance & phasors

Answer: B = 238.7 Hz

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Resonant frequency

f0 = 1/(2π·√(0.01·2.2·10⁻⁶)) = 1073 Hz

Quality factor

Q compares the reactance at resonance with the resistance: Q = ω₀L/R.

Q = (1/R)·√(L/C) = (1/15)·√(0.01/(2.2·10⁻⁶)) = 4.495

Bandwidth

B = f0/Q = 1073/4.495 = 238.7 Hz

Answer

B = 238.7 Hz
15.AC power & power factor

Answer: Q = 18.36 kvar

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Angle

φ = arccos(0.7) = 45.57°, tan φ = 1.02

Reactive power

Q = P·tan φ = 18·1.02 = 18.36 kvar

Answer

Q = 18.36 kvar
16.AC power & power factor

Answer: QC = 13.58 kvar

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Reactive power before and after

The real power P does not change; only the reactive power drawn from the supply does.

Q1 = P·tan φ1 = 20·tan(41.41°) = 17.64 kvar
Q2 = P·tan φ2 = 20·tan(11.48°) = 4.061 kvar
QC = Q1 − Q2 = 13.58 kvar

Answer

QC = 13.58 kvar
17.Three-phase power

Answer: P = 22.97 kW

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.

Apparent power

S = √3·VL·IL = √3·208·75 = 27.02 kVA

Real power

P = S·cos φ = 27.02·0.85 = 22.97 kW

Answer

P = 22.97 kW
18.Three-phase power

Answer: Cph = 557.3 µF

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.

Reactive power before and after

The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.

Q1 = 100·tan(acos 0.65) = 100·1.169 = 116.9 kvar
Q2 = 100·tan(acos 0.95) = 100·0.3287 = 32.87 kvar

Reactive power from the capacitors

QC = Q1 − Q2 = 84.04 kvar

Capacitance per phase

In a Δ bank each capacitor is connected between two lines.

V = 400 V, ω = 2π·50 = 314.2 rad/s
Cph = (QC/3)/(ω·V²) = 28015/(314.2·400²) = 557.3 µF

Answer

Cph = 557.3 µF
19.Transformers

Answer: R1′ = 1800 Ω

Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.

Referred resistance

The voltage goes up by a and the current down by a, so the ratio V/I goes up by a².

R1′ = a²·RL = 6²·50 = 1800 Ω

Answer

R1′ = 1800 Ω
20.Transformers

Answer: Pcu,fl = 334.2 W

Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.

Output and input power

Pout = 25·0.9 = 22.5 kW
Pin = 22500/0.98 = 22959 W

Total and copper losses

Ploss = 22959 − 22500 = 459.2 W
Pcu,fl = 459.2 − 125 = 334.2 W

Answer

Pcu,fl = 334.2 W
21.Op-amp circuits

Answer: Rf = 190 kΩ

Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.

Gain of a non-inverting amplifier

V₋ = V₊ = Vin, and the current through R₁ also flows through Rf, so Vout = Vin·(1 + Rf/R₁).

Av = 1 + Rf/R1
Rf = (20 − 1)·10 = 190 kΩ

Answer

Rf = 190 kΩ
22.Op-amp circuits

Answer: Vout = −8.507 V

Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.

Input currents

V₋ = 0, so each input resistor has its full input voltage across it.

I1 = V1/R1 = 1.7/1 = 1.7 mA
I2 = V2/R2 = 1.1/10 = 0.11 mA
If = I1 + I2 = 1.81 mA

Output voltage

Vout = −Rf·If = −4.7·1.81 = −8.507 V

Answer

Vout = −8.507 V
23.Diodes & transistors

Answer: R = 600 Ω

LED and diode circuits: a forward-biased LED drops roughly its forward voltage VF (about 2 V for red, 3 V for blue or white), whatever the current. A series resistor sets the current: R = (Vs − n·VF)/I for n LEDs in series. With a more exact diode model V = V₀ + I·rd, the operating point is where the diode line meets the load line I = (Vs − V)/R, so I = (Vs − V₀)/(R + rd).

Voltage across the resistor

VR = 12 − 3·3 = 3 V

Resistance

R = 3/0.005 = 600 Ω

Answer

R = 600 Ω

The resistor dissipates 15 mW.

24.Diodes & transistors

Answer: ID = 11.12 mA

LED and diode circuits: a forward-biased LED drops roughly its forward voltage VF (about 2 V for red, 3 V for blue or white), whatever the current. A series resistor sets the current: R = (Vs − n·VF)/I for n LEDs in series. With a more exact diode model V = V₀ + I·rd, the operating point is where the diode line meets the load line I = (Vs − V)/R, so I = (Vs − V₀)/(R + rd).

Combine the two equations

12 = 0.6 + I·(1000 + 25)

Operating current

ID = 11.4/1025 = 11.12 mA
VD = 0.6 + 0.01112·25 = 0.878 V

Answer

ID = 11.12 mA
25.Number systems

Answer: U = 213

Setting bits: each bit is worth a power of two (128, 64, …, 1). One hex digit is exactly four bits, and in 8-bit two's complement the leftmost bit is worth −128. Bitwise operations work on each bit position separately.

Invert and add one

43 = 0010 1011
inverted: 1101 0100
+1 → 1101 0101

Read it as unsigned

1101 0101₂ = 256 − 43 = 213

Answer

U = 213
26.Number systems

Answer: N = −2.147 × 10⁹

Positional number systems: each digit is worth its value times a power of the base. In binary the places are worth 1, 2, 4, 8, 16, …; in hexadecimal 1, 16, 256, …, with A–F standing for 10–15. In 8-bit two's complement the leftmost bit is worth −128 instead of +128, which is how negative numbers are stored.

Most negative value

−231 = −2147483648

Answer

N = −2147483648
27.Digital logic: gates, K-maps & flip-flops

Answer: L = 9

Karnaugh maps: the cells are ordered in Gray code (00, 01, 11, 10), so neighbouring cells, including the ones across the edges, differ in exactly one variable. Group the 1s in rectangles of 1, 2, 4, 8 or 16 cells, as large as possible and as few as possible, until every 1 is covered. Each group is one product term: the variables that stay constant inside it. A group of 2ᵏ cells loses k variables. Don't-cares (X) may be used to make groups bigger but never have to be covered. Grouping the 0s instead gives the minimal POS form.

ABCD000111100001111000010312140507060120131151140809111110

Group the 1s

Every group is a rectangle of 2ᵏ cells; edge cells are neighbours of the cells on the opposite edge.

B′CD′
AC
A′BC′D′

Minimal SOP form

F = B′CD′ + AC + A′BC′D′
L = 9

Answer

L = 9
28.Digital logic: gates, K-maps & flip-flops

Answer: L = 8

Karnaugh maps: the cells are ordered in Gray code (00, 01, 11, 10), so neighbouring cells, including the ones across the edges, differ in exactly one variable. Group the 1s in rectangles of 1, 2, 4, 8 or 16 cells, as large as possible and as few as possible, until every 1 is covered. Each group is one product term: the variables that stay constant inside it. A group of 2ᵏ cells loses k variables. Don't-cares (X) may be used to make groups bigger but never have to be covered. Grouping the 0s instead gives the minimal POS form.

Prime implicants

The largest groups that can be formed from 1s and Xs.

B′CD′, BC′D, A′D, ACD′
ABCD000111100001111000X1X3X2041517060121130151140809011110

Minimal cover

F = BC′D + A′D + ACD′
L = 8

Answer

L = 8
29.Laplace transforms

Answer: f(0.5) = 1.546

Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).

Complete the square

s² + 8s + 17 = (s + 4)² + 1 = (s + 4)² + 1²

Match the numerator

F(s) = 1·(s + 4)/((s + 4)² + 1²) + (22/1)·1/((s + 4)² + 1²)

Inverse transform

f(t) = e−4t·(cos 1t + 22·sin 1t)
f(0.5) = e−4·0.5·(cos(1·0.5) + 22·sin(1·0.5)) = 1.546

Answer

f(0.5) = 1.546
30.Laplace transforms

Answer: g(0.3) = 0.6799

Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).

Transfer function

G(s) = Y(s)/U(s) = (s + 6)/(s² + 6s + 13)

Partial fractions

s² + 6s + 13 = (s + 3)² + 2²
G(s) = 1·(s + 3)/((s + 3)² + 2²) + (3/2)·2/((s + 3)² + 2²)

Impulse response

g(t) = e−3t·(cos 2t + 1.5·sin 2t)
g(0.3) = 0.6799

Answer

g(0.3) = 0.6799
31.Block diagrams

Answer: T(0) = 0.4255

Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).

Inner loop

Gᵢ = G/(1 + G·H₁) = 10/(s + 4 + 10·5) = 10/(s + 54)

Outer loop

T(s) = K·Gᵢ/(1 + K·Gᵢ) = 40/(s + 54 + 40) = 40/(s + 94)

Result

T(0) = 40/94 = 0.4255

Answer

T(0) = 0.4255
32.Block diagrams

Answer: ωd = 4 rad/s

Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).

Characteristic equation

s(s + 4) + 10·2 = 0 → s² + 4s + 20 = 0

Roots

s = −2 ± j·√(20 − 4) = −2 ± j4
ωd = 4 rad/s

Answer

ωd = 4 rad/s
33.Step response

Answer: tp = 0.4022 s

Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).

Compare with the standard form

The denominator must match s² + 2ζωₙs + ωₙ².

ωₙ² = 65 → ωₙ = 8.062 rad/s
2ζωₙ = 4 → ζ = 4/(2·8.062) = 0.2481

Result

ωd = 8.062·√(1 − 0.2481²) = 7.81 rad/s → tp = π/ωd = 0.4022 s

Answer

tp = 0.4022 s
34.Step response

Answer: ωn = 1459 rad/s

Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).

Natural frequency and damping ratio

ωₙ = 1/√(LC) = 1/√(0.1·4.7 × 10⁻⁶) = 1459 rad/s
ζ = (R/2)·√(C/L) = (88/2)·√(4.7 × 10⁻⁶/0.1) = 0.3016

Result

ωₙ = 1459 rad/s

Answer

ωn = 1459 rad/s
35.Bode plots & margins

Answer: BW = 159.2 Hz

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Resonant frequency

ω₀ = 1/√(LC) = 1/√(0.02·4.7 × 10⁻⁶) = 3262 rad/s
f₀ = ω₀/(2π) = 519.1 Hz

Bandwidth

BW = R/L = 20/0.02 = 1000 rad/s = 159.2 Hz

Answer

BW = 159.2 Hz
36.Bode plots & margins

Answer: K = 21.34

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Phase crossover

(ω/3)·(ω/5) = 1 → ω180 = √(3·5) = 3.873 rad/s

Magnitude at phase crossover

|L(jω180)| = K/(ω·√(ω² + 9)·√(ω² + 25)) = K/(3·5·(3 + 5)) = K/120

Required gain

120/K = 1015/20 = 5.623
K = 120/5.623 = 21.34

Answer

K = 21.34
37.Stability: Routh–Hurwitz & root locus

Answer: N = 2

Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.

Characteristic polynomial

s³ + 10s² + 24s + 480 = 0

Routh array

s³: 1, 24
s²: 10, 480
s¹: −24
s⁰: 480

Sign changes in the first column

1 → 10 → −24 → 480
N = 2

Answer

N = 2

The gain is above the limit K = 240, so a complex pair has crossed into the right half-plane.

38.Stability: Routh–Hurwitz & root locus

Answer: σa = −2.5

Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.

Poles and zeros

poles: 0, −6, −3
zeros: −4
n − m = 3 − 1 = 2

Centroid

σa = (−9 − (−4))/2 = −2.5

Answer

σa = −2.5

The 2 asymptotes leave the centroid at angles of 90°, 270°.

39.Steady-state error & PID control

Answer: ess = 9.091 %

Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.

Position constant

Kp = 2·5 = 10

Step error

ess = 100/(1 + 10) = 9.091 %

Answer

ess = 9.091 %
40.Steady-state error & PID control

Answer: %OS = 1.732 %

P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).

Characteristic polynomial

s(s + 5) + 5·2 = s² + 5s + 10

ωₙ and ζ

ωₙ = √10 = 3.162 rad/s
ζ = 5/(2·3.162) = 0.7906

Overshoot

%OS = 100·e−0.7906π/√(1 − 0.7906²) = 1.732 %

Answer

%OS = 1.732 %

ExamProblems · examproblems.com/courses/fe-exam-electrical