1Formulas and methods
Series & parallel resistors
Resistors in series
Req = R1 + R2 + …
Resistors in parallel
1/Req = 1/R1 + 1/R2 + …
Two in parallel
Req = R1R2 / (R1 + R2)
Ohm's law
V = I·R
Power
P = V·I = I²R = V²/R
Method
Start at the end of the network furthest from the terminals.
Combine resistors in series by adding them, and resistors in parallel with 1/R = 1/R₁ + 1/R₂ + …
Redraw the circuit after each step.
Repeat until one resistor is left between the terminals.
Nodal analysis
Kirchhoff’s current law
ΣIin = ΣIout
Branch current
I = (Va − Vb)/R
Reference node
Vground = 0
Method
Choose a reference node (ground) and label the other node voltages.
Write Kirchhoff’s current law at every unknown node: currents leaving through each branch equal the currents entering.
Express every branch current as (Va − Vb)/R.
Solve the system of equations, then find any current you need.
Mesh analysis
Kirchhoff’s voltage law
ΣV = 0 around every loop
Shared resistor
current = I1 − I2
Current source in a mesh
fixes that mesh current
Method
Draw a clockwise current in every mesh (window) of the circuit.
Apply Kirchhoff’s voltage law around each mesh: the sum of voltage drops is zero.
In a resistor shared by two meshes the current is the difference of the two mesh currents.
Solve the equations; a negative result means the current flows the other way.
Superposition
Superposition
x = x1 + x2 + … (one source at a time)
Switched-off voltage source
short circuit (0 V)
Switched-off current source
open circuit (0 A)
Voltage divider
V2 = V·R2/(R1 + R2)
Current divider
I1 = I·R2/(R1 + R2)
Method
Count the independent sources. You will solve one simpler circuit per source.
Keep one source and switch off the others: a voltage source becomes a short circuit (a wire), a current source becomes an open circuit (a gap).
Solve the simpler circuit for the voltage or current you need, keeping track of its direction.
Repeat for every source, then add the contributions with their signs.
Thévenin & Norton
Thévenin voltage
Vth = Vopen circuit
Thévenin resistance
Rth: all sources off, seen from a–b
Norton current
IN = Vth/Rth
Load current
IL = Vth/(Rth + RL)
Maximum power transfer
RL = Rth, Pmax = Vth²/(4Rth)
Method
Remove the load and mark the two terminals a and b.
Find the open-circuit voltage between a and b: this is Vth.
Switch off all independent sources and find the resistance seen from a–b: this is Rth.
Put the load back on the equivalent circuit: Vth in series with Rth.
For the Norton equivalent, convert: IN = Vth/Rth, with RN = Rth in parallel.
RC & RL transients
Time constant
τ = RC | τ = L/R
Response
x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ
Capacitor at DC
open circuit; vC cannot jump
Inductor at DC
short circuit; iL cannot jump
Settled
t ≈ 5τ
Method
Find the initial value just after switching: a capacitor voltage and an inductor current cannot jump.
Find the final value long after switching: a capacitor acts as an open circuit, an inductor as a short circuit.
Find the time constant: τ = RC or τ = L/R, using the resistance seen by the capacitor or inductor.
Use x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ.
AC impedance & phasors
Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z
Method
Convert the frequency: ω = 2πf.
Find each reactance: XL = ωL and XC = 1/(ωC).
Add impedances like resistors, with Z = R + jX.
Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.
AC power & power factor
Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)
Three-phase power
Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η
Transformers
Turns ratio
a = N1/N2 = V1/V2
Current ratio
I1/I2 = N2/N1 = 1/a
Rated current
I = S/V
Referred impedance
Z1′ = a²·ZL
Copper loss at part load
Pcu = x²·Pcu,fl
Efficiency
η = x·S·pf/(x·S·pf + Pcore + x²·Pcu,fl)
Maximum efficiency
x = √(Pcore/Pcu,fl)
Op-amp circuits
Inverting amplifier
Vout = −(Rf/Rin)·Vin
Non-inverting amplifier
Vout = (1 + Rf/R1)·Vin
Summing amplifier
Vout = −Rf(V1/R1 + V2/R2)
Ideal op-amp
V+ = V−, Iin = 0
Diodes & transistors
Diode (constant drop)
VD = 0.7 V when conducting
Active region
VBE = 0.7 V, IC = β·IB, IE = (β + 1)·IB
Fixed bias
IB = (VCC − 0.7)/RB
Divider bias
IB = (VTH − 0.7)/(RTH + (β + 1)RE)
Thévenin of the divider
VTH = VCC·R2/(R1 + R2), RTH = R1∥R2
Collector loop
VCE = VCC − ICRC − IERE
Saturation
IC(sat) = (VCC − VCE(sat))/RC, IB ≥ IC(sat)/β
Number systems
Place values
binary 2k, octal 8k, hex 16k
To decimal
Σ dk·bk
From decimal
divide by the base, read the remainders bottom-up
Hex ↔ binary
one hex digit = 4 bits
Two’s complement
invert the bits and add 1
Digital logic: gates, K-maps & flip-flops
Basic gates
A·B, A + B, A′, (A·B)′, (A + B)′, A ⊕ B
Boolean rules
X + X′ = 1, X·X′ = 0, X + XY = X, XY + XY′ = X
De Morgan
(X·Y)′ = X′ + Y′, (X + Y)′ = X′·Y′
Karnaugh map order
00, 01, 11, 10 (Gray code)
Group of 2ᵏ cells
loses k variables
4-to-1 multiplexer
F = A′B′I0 + A′BI1 + AB′I2 + ABI3
Flip-flops
D: Q⁺ = D, T: Q⁺ = T ⊕ Q, JK: Q⁺ = JQ′ + K′Q
Counters
n-bit: 2ⁿ states; mod-N: smallest n with 2ⁿ ≥ N; fout = fclk/N
Ripple counter
fmax = 1/(n·tpd)
Ring and Johnson counters
n and 2n states
Method
For a circuit, work from the inputs to the output one gate at a time and write the value on every wire, or write its expression and fill in the truth table.
For simplification, put the 1s (and the don’t-cares as X) into a Karnaugh map with Gray-code rows and columns: 00, 01, 11, 10.
Cover the 1s with as few and as large groups of 1, 2, 4, 8 or 16 cells as possible, wrapping round the edges; each group is one product term made of the variables that stay constant. Group the 0s for the POS form.
For flip-flops and counters, read the inputs at each active clock edge, write the state after every edge, and remember that an n-bit counter wraps round after 2ⁿ states.
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Series & parallel resistorsMedium
Find the current IR2 through R2.
V1 = 12 VR1 = 15 ΩR2 = 2 ΩR3 = 6 ΩR4 = 15 Ω
IR2 = A
2.Series & parallel resistorsHard
Find the current IR1 delivered by the source, which flows through R1.
The voltage source Vₛ between A and B has its + terminal at B, so it makes VB − VA = Vₛ. Use nodal analysis with a supernode to find the node voltage VB (measured from ground).
Is = 4 AVs = 12 VR1 = 10 ΩR2 = 4 Ω
VB = V
4.Nodal analysisHard
The current source is adjusted until the node voltage at A is VA = 17 V. Use nodal analysis to find the source current Is (direction as shown).
A linear resistive circuit contains three independent sources: V1, V2 and Is. The current I through a load is measured three times. With all sources at their normal values, I = 20 mA. With V1 doubled and the other two unchanged, I = 32 mA. With the direction of Is reversed and the other two unchanged, I = −2 mA. Find the load current I when V2 is switched off and V1 and Is have their normal values.
normal: I = 20 mA2·V1: I = 32 mA−Is: I = −2 mA
I = mA
9.Thévenin & NortonMedium
Find the Thévenin voltage Vth seen from terminals a–b.
V1 = 18 VR1 = 12 ΩR2 = 12 ΩR3 = 20 Ω
Vth = V
10.Thévenin & NortonHard
A load RL = 8 Ω is connected across a–b. Replace the rest of the circuit with its Thévenin equivalent and find the load current IL.
The inductor carries no current before the switch closes at t = 0. Find the voltage vL across the inductor at t = 1 ms.
Vs = 6 VR = 33 ΩL = 47 mHt = 1 ms
vL = V
12.RC & RL transientsHard
The switch has been closed for a long time, so the circuit is in steady state. At t = 0 the switch opens. Find the capacitor voltage vC at t = 150 ms.
Vs = 6 VR1 = 1 kΩR2 = 3.3 kΩC = 33 µFt = 150 ms
vC = V
13.AC impedance & phasorsMedium
A series RLC circuit with L = 100 mH must resonate at 200 Hz. Find the capacitance C needed.
f0 = 200 HzL = 100 mH
C = µF
14.AC impedance & phasorsHard
A series RLC circuit is connected to a 50 V (rms), 1000 Hz supply. Find the rms voltage VC across the capacitor.
V = 50 V (rms)f = 1000 HzR = 100 ΩL = 150 mHC = 2.2 µF
VC = V
15.AC power & power factorMedium
A single-phase motor takes 16 kW at a power factor of 0.9 lagging from a 240 V supply. Find the reactive power Q it draws.
P = 16 kWpf = 0.9V = 240 V
Q = kvar
16.AC power & power factorHard
A 100 V (rms), 50 Hz source has an internal impedance Zs = 10 + j40 Ω. The load impedance ZL can be chosen freely. The load for maximum power is built from a resistor in series with a capacitor. Find the capacitance C.
Vs = 100 V (rms)f = 50 HzZs = 10 + j40 Ω
C = µF
17.Three-phase powerMedium
A balanced Δ-connected load with an impedance of 5 + j12 Ω per phase is connected to a balanced three-phase supply with a line-to-line voltage of 400 V. Find the total real power P absorbed by the load in kW.
VL = 400 VZ = 5 + j12 Ω per phase
P = kW
18.Three-phase powerHard
A balanced three-phase load takes 250 kW at a power factor of 0.72 lagging from a 480 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.98 lagging. The real power stays the same. The capacitors are connected in Y. Find the capacitance Cph of each capacitor in µF.
P = 250 kWpf1 = 0.72pf2 = 0.98VL = 480 Vf = 60 Hz
Cph = µF
19.TransformersMedium
A 2 Ω resistor is connected across the secondary winding of an ideal transformer with a turns ratio N₁:N₂ = 12:1. Find the resistance R1′ seen looking into the primary winding.
N1:N2 = 12:1RL = 2 Ω
R1′ = Ω
20.TransformersHard
A single-phase 150 kVA transformer has a core loss of 750 W and a copper loss of 1500 W at rated load. It supplies 50% of its rated kVA at a power factor of 0.9 lagging. Find the total losses Ploss in watts at this load.
The op-amp is ideal and runs from ±15 V supplies. Find the output voltage Vout.
Vin = −0.7 VR1 = 4.7 kΩRf = 10 kΩ
Vout = V
22.Op-amp circuitsHard
Two ideal op-amp stages are connected in cascade: an inverting amplifier (R1, Rf1) followed by a non-inverting amplifier (R2 to ground, Rf2 in the feedback). Both run from ±15 V supplies. The input is Vin = 0.95 V. Find the output voltage Vout.
An NPN transistor with β = 75 is biased by a base resistor RB = 220 kΩ from the supply VCC = 12 V. The collector resistor is RC = 2.2 kΩ and the emitter is grounded. Take VBE = 0.7 V and assume the transistor is in the active region. Find the collector–emitter voltage VCE.
VCC = 12 VRB = 220 kΩRC = 2.2 kΩβ = 75VBE = 0.7 V
VCE = V
24.Diodes & transistorsHard
An NPN transistor with β = 80 switches a 330 Ω load resistor connected between VCC = 24 V and its collector. The emitter is grounded. The base is driven from a 3.3 V logic output through a base resistor RB. Take VBE = 0.7 V and VCE(sat) = 0.2 V. For reliable switching, design for a base current 4 times the minimum needed for saturation. Find RB in kΩ.
A 4-to-1 multiplexer has its select inputs S₁ = A and S₀ = B, and its data inputs tied to I₀ = C, I₁ = C, I₂ = C, I₃ = 1. For how many of the 8 combinations of A, B and C is the output F = 1? Find N.
I₀ = CI₁ = CI₂ = CI₃ = 1
N =
28.Digital logic: gates, K-maps & flip-flopsHard
A synchronous mod-9 counter counts 0, 1, …, 8 and then returns to 0. It starts at 0. Which count Q (in decimal) does it show after 11 clock pulses?
Q0 = 011N = 9
Q =
29.Laplace transformsMedium
F(s) = (4s + 37)/(s² + 5s + 6). Its inverse transform has the form f(t) = A·e−2t + B·e−3t. Find the coefficient A by partial fractions.
F(s) = (4s + 37)/(s² + 5s + 6)
A =
30.Laplace transformsHard
A system obeys y″ + 6y′ + 5y = 10·u(t), with y(0) = 3 and y′(0) = 0. At t = 0 a step input u(t) = 1 is applied. Use the Laplace transform to find y(0.3).
The plant G(s) = 7/(s + 8) has an inner (minor) negative feedback loop with gain H₁ = 5. A controller gain K = 13 and an outer unity negative feedback loop close the system. Find the closed-loop pole p.
G(s) = 7/(s + 8)H₁ = 5K = 13
p =
32.Block diagramsHard
A proportional controller K = 12 drives the plant G(s) = 8/(s + 4) in a unity negative feedback loop. A disturbance D enters at the plant input (it is added to the controller output). A reference step of size 1 and a disturbance step of size 10 are applied together. Find the steady-state output css.
K = 12G(s) = 8/(s + 4)D = 10R = 1
css =
33.Step responseMedium
A system has the transfer function G(s) = 46/(s² + 6s + 23) and receives a unit step input. Find the natural frequency ωn in rad/s.
G(s) = 46/(s² + 6s + 23)
ωn = rad/s
34.Step responseHard
A unity negative feedback loop has G(s) = K/(s(s + 10)). Find the gain K that gives a step response with 5 % overshoot.
G(s) = K/(s(s + 10))%OS = 5 %
K =
35.Bode plots & marginsMedium
In the series RLC band-pass filter shown the output is taken across R = 10 Ω, with L = 1 mH and C = 1 µF. Find the centre (resonant) frequency f0 in Hz.
R = 10 ΩL = 1 mHC = 1 µF
f0 = Hz
36.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 164/(s(s + 5)(s + 8)). Find the phase crossover frequency ω180, where ∠L(jω) = −180°.
L(s) = 164/(s(s + 5)(s + 8))
ω180 = rad/s
37.Stability: Routh–Hurwitz & root locusMedium
A unity-feedback loop has L(s) = K/((s + 1)(s + 3)(s + 6)), with K > 0. Find the largest gain Kmax for which the closed loop is stable.
L(s) = K/((s + 1)(s + 3)(s + 6))
Kmax =
38.Stability: Routh–Hurwitz & root locusHard
For the loop L(s) = K/(s(s + 4)(s + 5)), find the gain K that puts a closed-loop pole at s = −0.5.
L(s) = K/(s(s + 4)(s + 5))s = −0.5
K =
39.Steady-state error & PID controlMedium
The parabolic input r(t) = 4·t²/2 is applied to a unity-feedback loop with G(s) = 20(s + 2)/(s²(s + 10)). Find the steady-state error ess.
G(s) = 20(s + 2)/(s²(s + 10))r(t) = 4·t²/2
ess =
40.Steady-state error & PID controlHard
A PI controller C(s) = Kp + Ki/s drives the plant G(s) = 4/(s + 2) in a unity-feedback loop. The closed loop must have ωₙ = 2 rad/s and ζ = 0.7. Find the proportional gain Kp.
G(s) = 4/(s + 2)ωₙ = 2 rad/sζ = 0.7
Kp =
3Solutions
1.Series & parallel resistors
Answer: IR2 = 0.6512 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 6 + 15 = 21 Ω
R2 ∥ 21 = 2·21/(2+21) = 1.826 Ω
Req = R1 + 1.826 = 15 + 1.826 = 16.83 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 12/16.83 = 0.7132 A
Current through R₂
Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.
VA = V1 − IR1·R1 = 12 − 0.7132·15 = 1.302 V
IR2 = VA/R2 = 1.302/2 = 0.6512 A
Answer
IR2 = 0.6512 A
2.Series & parallel resistors
Answer: IR1 = 8.004 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 25 + 6 = 31 Ω
R4 ∥ 31 = 1.879 Ω
R3 + 1.879 = 13.88 Ω
R2 ∥ 13.88 = 1.748 Ω
Req = R1 + 1.748 = 2 + 1.748 = 3.748 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 30/3.748 = 8.004 A
Answer
IR1 = 8.004 A
3.Nodal analysis
Answer: VB = 14.86 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Form a supernode
The voltage source between A and B carries an unknown current, so KCL cannot be written at A or B separately. Enclose A, B and the source in one supernode: the current entering it equals the current leaving it.
VB = VA + Vs = VA + 12
VA/R1 + VB/R2 = Is
Solve
VA/10 + (VA + 12)/4 = 4
VA = (4 − 12/4)/(1/10 + 1/4) = 2.857 V
VB = 2.857 + 12 = 14.86 V
Answer
VB = 14.86 V
4.Nodal analysis
Answer: Is = 6.042 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
KCL at node A
VA is known, so this equation gives VB.
(VA − V1)/R1 + VA/R2 + (VA − VB)/R3 = 0
(17 − 24)/6 + 17/4 = (VB − 17)/6
3.083 = (VB − 17)/6 → VB = 35.5 V
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
Is = (VB − VA)/R3 + VB/R4 = (35.5 − 17)/6 + 35.5/12 = 6.042 A
Answer
Is = 6.042 A
5.Mesh analysis
Answer: IR1 = 1.742 A
Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.
Assign mesh currents
Draw a clockwise current in each window: I1, I2. A resistor shared by two meshes carries the difference of their currents.
KVL around mesh 1
Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).
R1·I1 + R3(I1 − I2) = V1
10·I1 + 4(I1 − I2) = 24
14·I1 − 4·I2 = 24
KVL around mesh 2
Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).
R2·I2 + R3(I2 − I1) = −V2
6·I2 + 4(I2 − I1) = (−6)
−4·I1 + 10·I2 = −6
Solve
Δ = (14)(10) − (−4)(−4) = 124
I1 = Δ1/Δ = 216/124 = 1.742 A
I2 = Δ2/Δ = 12/124 = 0.09677 A
Answer
IR1 = I1 = 1.742 A
A negative mesh current flows anticlockwise.
6.Mesh analysis
Answer: IR4 = 0.3503 A
Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.
Assign mesh currents
Draw a clockwise current in each window: I1, I2, I3. A resistor shared by two meshes carries the difference of their currents.
KVL around mesh 1
Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).
R1·I1 + R4(I1 − I2) = V1
20·I1 + 12(I1 − I2) = 9
32·I1 − 12·I2 = 9
KVL around mesh 2
Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).
R2·I2 + R4(I2 − I1) + R5(I2 − I3) = 0
20·I2 + 12(I2 − I1) + 20(I2 − I3) = 0
−12·I1 + 52·I2 − 20·I3 = 0
KVL around mesh 3
Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).
R3·I3 + R5(I3 − I2) = −V2
6·I3 + 20(I3 − I2) = (−9)
−20·I2 + 26·I3 = −9
Solve
Δ = det of the coefficient matrix = 26720
I1 = Δ1/Δ = 6408/26720 = 0.2398 A
I2 = Δ2/Δ = −2952/26720 = −0.1105 A
I3 = Δ3/Δ = −11520/26720 = −0.4311 A
Answer
IR4 = I1 − I2 = 0.3503 A
A negative mesh current flows anticlockwise.
7.Superposition
Answer: IR2 = −1.309 A
Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.
Case 1 · V1 acting alone
Iₛ becomes an open circuit, so R₃ and R₄ form one series branch from A to ground, in parallel with R₂.
R3+R4 = 2+8 = 10 Ω
R2 ∥ (R3+R4) = 6·10/(6+10) = 3.75 Ω
VA = 15·3.75/(8+3.75) = 4.787 V
VB = VA·R4/(R3+R4) = 4.787·8/10 = 3.83 V
IR2′ = (0 − VA)/R2 = (0 − 4.787)/6 = −0.7979 A
Case 2 · Is acting alone
V₁ becomes a short, so R₁ is in parallel with R₂. Iₛ splits at B between R₄ and the path through R₃.
R1 ∥ R2 = 8·6/(8+6) = 3.429 Ω
Req = R4 ∥ (R3+R1∥R2) = 8 ∥ 5.429 = 3.234 Ω
VB = Is·Req = 1.5·3.234 = 4.851 V
VA = VB·(R1∥R2)/(R3+R1∥R2) = 4.851·3.429/5.429 = 3.064 V
IR2″ = (0 − VA)/R2 = (0 − 3.064)/6 = −0.5106 A
Add the contributions
IR2 = IR2′ + IR2″
IR2 = (−0.7979) + (−0.5106) = −1.309 A
A negative result means the real current flows against the arrow.
8.Superposition
Answer: I = 23 mA
Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.
Write the measurements with contributions
Each contribution is proportional to its own source.
I₁ + I₂ + I₃ = 20
2·I₁ + I₂ + I₃ = 32
I₁ + I₂ − I₃ = −2
Solve for the contributions
I₁ = 32 − 20 = 12 mA
I₃ = (20 − (−2))/2 = 11 mA
I₂ = 20 − 12 − 11 = −3 mA
Switch V₂ off
I = I₁ + I₃ = 12 + 11 = 23 mA
Answer
I = 23 mA
9.Thévenin & Norton
Answer: Vth = 9 V
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 12·12/(12+12) = 6 Ω
Rth = (R1 ∥ R2) + R3 = 6 + 20 = 26 Ω
Find Vth, the open-circuit voltage
With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.
Vth = V1·R2/(R1+R2) = 18·12/(12+12) = 9 V
10.Thévenin & Norton
Answer: IL = 1.53 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 20·15/(20+15) = 8.571 Ω
Rth = (R1 ∥ R2) + R3 = 8.571 + 12 = 20.57 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 12.86 + 1.5·8.571 = 25.71 V
Vth = VB = VA + Is·R3 = 25.71 + 1.5·12 = 43.71 V
Connect the load to the Thévenin equivalent
The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.
IL = Vth/(Rth + RL) = 43.71/(20.57 + 8) = 1.53 A
11.RC & RL transients
Answer: vL = 2.973 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant and final current
Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.
τ = L/R = 47 mH / 33 Ω = 1.424 ms
i(∞) = Vs/R = 6/33 = 0.1818 A
Inductor voltage
At t = 0 the whole supply voltage appears across the inductor; it then decays to zero.
vL(t) = Vs·e−t/τ = 6·e−1/1.424 = 2.973 V
Answer
vL = 2.973 V
12.RC & RL transients
Answer: vC = 1.161 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial capacitor voltage
In steady state the capacitor is an open circuit, so R₁ and R₂ form a voltage divider. The capacitor voltage cannot jump when the switch opens.
vC(0) = 6·3.3/(1 + 3.3) = 4.605 V
Time constant after the switch opens
τ = R2·C = 3.3·33 = 108.9 ms
Discharge
vC(t) = 4.605·e−150/108.9 = 1.161 V
Answer
vC = 1.161 V
13.AC impedance & phasors
Answer: C = 6.333 µF
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance condition
At resonance the inductive and capacitive reactances cancel: ωL = 1/(ωC).
ω₀ = 2π·200 = 1257 rad/s
C = 1/(ω₀²·L) = 1/(1257²·0.1) = 6.333 µF
Answer
C = 6.333 µF
14.AC impedance & phasors
Answer: VC = 4.13 V
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
ω = 2πf = 2π·1000 = 6283 rad/s
XL = ωL = 6283·0.15 = 942.5 Ω
XC = 1/(ωC) = 1/(6283·2.2·10⁻⁶) = 72.34 Ω
Impedance
In series the impedances add as complex numbers: Z = R + j(XL − XC).
The same current flows through every element of a series circuit.
I = V/|Z| = 50/875.9 = 0.05709 A
Voltage across the capacitor
VC = I·XC = 0.05709·72.34 = 4.13 V
Answer
VC = 4.13 V
15.AC power & power factor
Answer: Q = 7.749 kvar
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Angle
φ = arccos(0.9) = 25.84°, tan φ = 0.4843
Reactive power
Q = P·tan φ = 16·0.4843 = 7.749 kvar
Answer
Q = 7.749 kvar
16.AC power & power factor
Answer: C = 79.58 µF
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Conjugate match
The load reactance cancels the source reactance, and the load resistance equals the source resistance.
ZL = Zs* = 10 − j40 Ω
Capacitance
XC = 40 Ω → C = 1/(2π·50·40) = 79.58 µF
Answer
C = 79.58 µF
17.Three-phase power
Answer: P = 14.2 kW
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Phase voltage
Vph = VL = 400 V
Phase current
|Z| = √(5² + 12²) = 13 Ω
Iph = 400/13 = 30.77 A
Total real power
Only the resistive part of each impedance absorbs real power.
P = 3·Iph²·R = 3·30.77²·5 = 14.2 kW
Answer
P = 14.2 kW
Check: cos φ = R/|Z| = 0.3846, and √3·VL·IL·cos φ gives the same power.
18.Three-phase power
Answer: Cph = 2190 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 250·tan(acos 0.72) = 250·0.9639 = 241 kvar
Q2 = 250·tan(acos 0.98) = 250·0.2031 = 50.76 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 190.2 kvar
Capacitance per phase
In a Y bank each capacitor is connected between a line and the star point.
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Referred resistance
The voltage goes up by a and the current down by a, so the ratio V/I goes up by a².
R1′ = a²·RL = 12²·2 = 288 Ω
Answer
R1′ = 288 Ω
20.Transformers
Answer: Ploss = 1125 W
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.
Copper loss at this load
Pcu = x²·Pcu,fl = 0.25·1500 = 375 W
Total losses
The core loss is the same at any load.
Ploss = 750 + 375 = 1125 W
Answer
Ploss = 1125 W
The efficiency at this load is η = 98.36%.
21.Op-amp circuits
Answer: Vout = −2.189 V
Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.
Inverting input follows the input
V₋ = V₊ = −0.7 V
I = V₋/R1 = −0.7/4.7 = −0.1489 mA
Output voltage
The current through R₁ also flows through Rf.
Vout = V₋ + I·Rf = −0.7 + (−0.1489)·10 = −2.189 V
Answer
Vout = −2.189 V
22.Op-amp circuits
Answer: Vout = −1.395 V
Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.
Gain of each stage
A1 = −Rf1/R1 = −4.7/4.7 = −1
A2 = 1 + Rf2/R2 = 1 + 22/47 = 1.468
Stage by stage
V1 = −1·0.95 = −0.95 V
Vout = 1.468·(−0.95) = −1.395 V
Answer
Vout = −1.395 V
23.Diodes & transistors
Answer: VCE = 3.525 V
BJT bias point: in the active region VBE = 0.7 V, IC = β·IB and IE = (β + 1)·IB. Find IB from the base loop with KVL, then IC, then VCE from the collector–emitter loop. A voltage divider at the base is replaced by its Thévenin equivalent VTH = VCC·R₂/(R₁ + R₂), RTH = R₁∥R₂; an emitter resistor appears (β + 1) times larger in the base loop.
BJT as a switch: to switch a load fully on, the transistor is driven into saturation, where VCE = VCE(sat) and the collector current is set by the load: IC(sat) = (VCC − VCE(sat))/RC. Saturation needs at least IB = IC(sat)/β. If the base current is smaller, the transistor stays active and IC = β·IB.
Collector current in saturation
IC(sat) = (24 − 0.2)/330 = 72.12 mA
Minimum base current
IB(min) = IC(sat)/β = 72.12/80 = 901.5 µA
Design base current
IB = 4·901.5 µA = 3606 µA
Base resistor
RB = (3.3 − 0.7)/IB = 2.6 V/3.606 mA = 0.721 kΩ
Answer
RB = 0.721 kΩ
25.Number systems
Answer: U = 147
Positional number systems: each digit is worth its value times a power of the base. In binary the places are worth 1, 2, 4, 8, 16, …; in hexadecimal 1, 16, 256, …, with A–F standing for 10–15. In 8-bit two's complement the leftmost bit is worth −128 instead of +128, which is how negative numbers are stored.
Invert and add one
109 = 0110 1101
inverted: 1001 0010
+1 → 1001 0011
Read it as unsigned
1001 0011₂ = 256 − 109 = 147
Answer
U = 147
26.Number systems
Answer: M = 1024 KiB
Positional number systems: each digit is worth its value times a power of the base. In binary the places are worth 1, 2, 4, 8, 16, …; in hexadecimal 1, 16, 256, …, with A–F standing for 10–15. In 8-bit two's complement the leftmost bit is worth −128 instead of +128, which is how negative numbers are stored.
Bits and bytes
512·512·32 = 8388608 bit = 1048576 B
Convert to KiB
1048576/1024 = 1024 KiB
Answer
M = 1024 KiB
27.Digital logic: gates, K-maps & flip-flops
Answer: N = 5
Multiplexer: a 2ⁿ-to-1 multiplexer passes one of its data inputs to the output; the select lines, read as a binary number, pick which one. For a 4-to-1 MUX with selects S₁S₀ = AB, F = A′B′·I₀ + A′B·I₁ + AB′·I₂ + AB·I₃. Tying the data inputs to 0, 1, C or C′ makes the MUX produce any function of A, B and C, which is a common way to build logic with one chip.
Output expression
F = A′B′C + A′BC + AB′C + AB
Rows with F = 1
ABC = 001, 011, 101, 110, 111
N = 5
Answer
N = 5
28.Digital logic: gates, K-maps & flip-flops
Answer: Q = 2
Flip-flops and counters: a flip-flop changes only at the active clock edge. D copies its input (Q⁺ = D); T toggles when T = 1; JK holds for 00, resets for 01, sets for 10 and toggles for 11. An n-bit binary counter has 2ⁿ states and counts modulo 2ⁿ; a mod-N counter goes 0, 1, …, N − 1 and back to 0, and needs the smallest n with 2ⁿ ≥ N flip-flops. Each stage of a ripple counter halves the frequency, so the last output of a mod-N counter runs at fclk/N. A Johnson counter of n flip-flops has 2n states, a ring counter n.
Full cycles
Every 9 pulses bring the counter back to the same state.
11 = 1·9 + 2
Count after the remaining pulses
Q = (0 + 2) mod 9 = 2
Q = 0010₂
Answer
Q = 2
29.Laplace transforms
Answer: A = 29
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Factor the denominator
s² + 5s + 6 = (s + 2)(s + 3)
F(s) = A/(s + 2) + B/(s + 3)
Cover-up rule
Multiply by (s + 2) and set s = −2: the B-term vanishes.
A = (4s + 37)/(s + 3) |s = −2 = 29/1 = 29
Answer
A = 29
(B = −25, so f(t) = 29·e−2t − 25·e−3t)
30.Laplace transforms
Answer: y(0.3) = 2.87
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transform the equation
(s² + 6s + 5)·Y(s) = 3s + 18 + 10/s
Y(s) = (3s² + 18s + 10)/(s(s + 1)(s + 5))
Partial fractions
A = 10/(1·5) = 2
B = −5/((−1)·4) = 1.25
C = −5/((−5)·(−4)) = −0.25
Result
y(t) = 2 + 1.25·e−t − 0.25·e−5t
y(0.3) = 2.87
Answer
y(0.3) = 2.87
Check: y(0) = A + B + C = 3.
31.Block diagrams
Answer: p = −134
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Transfer functions
C/D = G/(1 + K·G) = 8/(s + 4 + 96)
C/R = K·G/(1 + K·G) = 96/(s + 4 + 96)
Steady state
css = 1·96/100 + 10·8/100 = 1.76
Answer
css = 1.76
A larger K reduces the effect of the disturbance, but never to zero with a proportional controller.
33.Step response
Answer: ωn = 4.796 rad/s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 23 → ωₙ = 4.796 rad/s
2ζωₙ = 6 → ζ = 6/(2·4.796) = 0.6255
Result
ωₙ = 4.796 rad/s
Answer
ωn = 4.796 rad/s
34.Step response
Answer: K = 52.49
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Closed-loop transfer function
T(s) = K/(s² + 10s + K)
Damping ratio from the overshoot
ζ = −ln(0.05)/√(π² + ln²(0.05)) = 0.6901
Gain
ωₙ = 10/(2ζ) = 7.245 rad/s
K = ωₙ² = 52.49
Answer
K = 52.49
35.Bode plots & margins
Answer: f0 = 5033 Hz
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Resonant frequency
ω₀ = 1/√(LC) = 1/√(0.001·1 × 10⁻⁶) = 31623 rad/s
f₀ = ω₀/(2π) = 5033 Hz
Answer
f0 = 5033 Hz
36.Bode plots & margins
Answer: ω180 = 6.325 rad/s
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Phase crossover
(ω/5)·(ω/8) = 1 → ω180 = √(5·8) = 6.325 rad/s
Answer
ω180 = 6.325 rad/s
37.Stability: Routh–Hurwitz & root locus
Answer: Kmax = 252
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
Characteristic polynomial
s³ + 10s² + 27s + 18 + K = 0
Routh array
s³: 1, 27
s²: 10, 18 + K
s¹: (10·27 − 18 − K)/10
s⁰: 18 + K
Condition
The s¹ entry must stay positive.
K < 10·27 − 18 = 252
Answer
Kmax = 252
At the limit the loop oscillates at ω = √27 = 5.196 rad/s.
38.Stability: Routh–Hurwitz & root locus
Answer: K = 7.875
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Magnitude condition
K = |s|·|s + 4|·|s + 5|
Evaluate at the point
K = 0.5·3.5·4.5 = 7.875
Answer
K = 7.875
Check: s(s + 4)(s + 5) + K is zero at s = −0.5.
39.Steady-state error & PID control
Answer: ess = 1
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Acceleration constant
Ka = 20·2/10 = 4
Parabola error
ess = 4/4 = 1
Answer
ess = 1
40.Steady-state error & PID control
Answer: Kp = 0.2
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
1 + C(s)G(s) = 0, multiplied by s(s + 2).
s² + (2 + 4Kp)s + 4Ki
Target polynomial
s² + 2·0.7·2s + 2² = s² + 2.8s + 4
Match the coefficients
2 + 4Kp = 2.8 → Kp = 0.2
Answer
Kp = 0.2
The integral term makes the loop type 1, so a step is followed without steady-state error.
This is independent practice material. ExamProblems is not affiliated with or endorsed by the organisation that runs this exam, and the exam name is used only to describe the content. The FE exam is run by NCEES, which is not affiliated with ExamProblems and does not endorse it.