In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Series & parallel resistors
Resistors in series
Req = R1 + R2 + …
Resistors in parallel
1/Req = 1/R1 + 1/R2 + …
Two in parallel
Req = R1R2 / (R1 + R2)
Ohm's law
V = I·R
Power
P = V·I = I²R = V²/R
Method
Start at the end of the network furthest from the terminals.
Combine resistors in series by adding them, and resistors in parallel with 1/R = 1/R₁ + 1/R₂ + …
Redraw the circuit after each step.
Repeat until one resistor is left between the terminals.
Nodal analysis
Kirchhoff’s current law
ΣIin = ΣIout
Branch current
I = (Va − Vb)/R
Reference node
Vground = 0
Method
Choose a reference node (ground) and label the other node voltages.
Write Kirchhoff’s current law at every unknown node: currents leaving through each branch equal the currents entering.
Express every branch current as (Va − Vb)/R.
Solve the system of equations, then find any current you need.
Mesh analysis
Kirchhoff’s voltage law
ΣV = 0 around every loop
Shared resistor
current = I1 − I2
Current source in a mesh
fixes that mesh current
Method
Draw a clockwise current in every mesh (window) of the circuit.
Apply Kirchhoff’s voltage law around each mesh: the sum of voltage drops is zero.
In a resistor shared by two meshes the current is the difference of the two mesh currents.
Solve the equations; a negative result means the current flows the other way.
Superposition
Superposition
x = x1 + x2 + … (one source at a time)
Switched-off voltage source
short circuit (0 V)
Switched-off current source
open circuit (0 A)
Voltage divider
V2 = V·R2/(R1 + R2)
Current divider
I1 = I·R2/(R1 + R2)
Method
Count the independent sources. You will solve one simpler circuit per source.
Keep one source and switch off the others: a voltage source becomes a short circuit (a wire), a current source becomes an open circuit (a gap).
Solve the simpler circuit for the voltage or current you need, keeping track of its direction.
Repeat for every source, then add the contributions with their signs.
Thévenin & Norton
Thévenin voltage
Vth = Vopen circuit
Thévenin resistance
Rth: all sources off, seen from a–b
Norton current
IN = Vth/Rth
Load current
IL = Vth/(Rth + RL)
Maximum power transfer
RL = Rth, Pmax = Vth²/(4Rth)
Method
Remove the load and mark the two terminals a and b.
Find the open-circuit voltage between a and b: this is Vth.
Switch off all independent sources and find the resistance seen from a–b: this is Rth.
Put the load back on the equivalent circuit: Vth in series with Rth.
For the Norton equivalent, convert: IN = Vth/Rth, with RN = Rth in parallel.
RC & RL transients
Time constant
τ = RC | τ = L/R
Response
x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ
Capacitor at DC
open circuit; vC cannot jump
Inductor at DC
short circuit; iL cannot jump
Settled
t ≈ 5τ
Method
Find the initial value just after switching: a capacitor voltage and an inductor current cannot jump.
Find the final value long after switching: a capacitor acts as an open circuit, an inductor as a short circuit.
Find the time constant: τ = RC or τ = L/R, using the resistance seen by the capacitor or inductor.
Use x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ.
AC impedance & phasors
Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z
Method
Convert the frequency: ω = 2πf.
Find each reactance: XL = ωL and XC = 1/(ωC).
Add impedances like resistors, with Z = R + jX.
Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.
AC power & power factor
Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)
Three-phase power
Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η
Transformers
Turns ratio
a = N1/N2 = V1/V2
Current ratio
I1/I2 = N2/N1 = 1/a
Rated current
I = S/V
Referred impedance
Z1′ = a²·ZL
Copper loss at part load
Pcu = x²·Pcu,fl
Efficiency
η = x·S·pf/(x·S·pf + Pcore + x²·Pcu,fl)
Maximum efficiency
x = √(Pcore/Pcu,fl)
Op-amp circuits
Inverting amplifier
Vout = −(Rf/Rin)·Vin
Non-inverting amplifier
Vout = (1 + Rf/R1)·Vin
Summing amplifier
Vout = −Rf(V1/R1 + V2/R2)
Ideal op-amp
V+ = V−, Iin = 0
Diodes & transistors
Diode (constant drop)
VD = 0.7 V when conducting
Active region
VBE = 0.7 V, IC = β·IB, IE = (β + 1)·IB
Fixed bias
IB = (VCC − 0.7)/RB
Divider bias
IB = (VTH − 0.7)/(RTH + (β + 1)RE)
Thévenin of the divider
VTH = VCC·R2/(R1 + R2), RTH = R1∥R2
Collector loop
VCE = VCC − ICRC − IERE
Saturation
IC(sat) = (VCC − VCE(sat))/RC, IB ≥ IC(sat)/β
Number systems
Place values
binary 2k, octal 8k, hex 16k
To decimal
Σ dk·bk
From decimal
divide by the base, read the remainders bottom-up
Hex ↔ binary
one hex digit = 4 bits
Two’s complement
invert the bits and add 1
Digital logic: gates, K-maps & flip-flops
Basic gates
A·B, A + B, A′, (A·B)′, (A + B)′, A ⊕ B
Boolean rules
X + X′ = 1, X·X′ = 0, X + XY = X, XY + XY′ = X
De Morgan
(X·Y)′ = X′ + Y′, (X + Y)′ = X′·Y′
Karnaugh map order
00, 01, 11, 10 (Gray code)
Group of 2ᵏ cells
loses k variables
4-to-1 multiplexer
F = A′B′I0 + A′BI1 + AB′I2 + ABI3
Flip-flops
D: Q⁺ = D, T: Q⁺ = T ⊕ Q, JK: Q⁺ = JQ′ + K′Q
Counters
n-bit: 2ⁿ states; mod-N: smallest n with 2ⁿ ≥ N; fout = fclk/N
Ripple counter
fmax = 1/(n·tpd)
Ring and Johnson counters
n and 2n states
Method
For a circuit, work from the inputs to the output one gate at a time and write the value on every wire, or write its expression and fill in the truth table.
For simplification, put the 1s (and the don’t-cares as X) into a Karnaugh map with Gray-code rows and columns: 00, 01, 11, 10.
Cover the 1s with as few and as large groups of 1, 2, 4, 8 or 16 cells as possible, wrapping round the edges; each group is one product term made of the variables that stay constant. Group the 0s for the POS form.
For flip-flops and counters, read the inputs at each active clock edge, write the state after every edge, and remember that an n-bit counter wraps round after 2ⁿ states.
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
The voltage source Vₛ between A and B has its + terminal at B, so it makes VB − VA = Vₛ. Use nodal analysis with a supernode to find the current Ix through the voltage source, from A to B as shown by the arrow.
Is = 4 AVs = 3 VR1 = 4 ΩR2 = 3 Ω
Ix = A
4.Nodal analysisHard
The voltage source Vₛ between A and B has its + terminal at A, so it makes VA − VB = Vₛ. Use nodal analysis with a supernode to find the node voltage VB (measured from ground).
The inductor carries no current before the switch closes at t = 0. Find the energy W(∞) stored in the inductor once the circuit has settled, in mJ.
Vs = 12 VR = 15 ΩL = 150 mH
W(∞) = mJ
12.RC & RL transientsHard
Just before the switch closes at t = 0, the capacitor holds 20 V with the polarity shown. How long does it take for vC to reach 15 V? Find t.
Vs = 10 VR = 6.8 kΩC = 10 µFvC(0) = 20 V
t = ms
13.AC impedance & phasorsMedium
A series RLC circuit is connected to a 50 V (rms), 100 Hz supply. Find the power factor cos φ of the circuit.
V = 50 V (rms)f = 100 HzR = 100 ΩL = 20 mHC = 10 µF
cos φ =
14.AC impedance & phasorsHard
A resistor R1 is connected in series with a parallel combination of R2 and a capacitor C, across a 230 V (rms), 100 Hz supply. Find the rms current I.
V = 230 V (rms)f = 100 HzR1 = 40 ΩR2 = 150 ΩC = 10 µF
I = A
15.AC power & power factorMedium
A single-phase motor takes 27 kW at a power factor of 0.65 lagging from a 230 V supply. Find the line current I.
P = 27 kWpf = 0.65V = 230 V
I = A
16.AC power & power factorHard
A single-phase load takes 35 kW at a power factor of 0.75 lagging from a 230 V, 50 Hz supply. A capacitor connected in parallel raises the power factor to 0.98. Find the new line current Inew.
P = 35 kWpf1 = 0.75pf2 = 0.98V = 230 Vf = 50 Hz
Inew = A
17.Three-phase powerMedium
A balanced three-phase load draws a line current of 20 A from a supply with a line-to-line voltage of 208 V. The power factor is 0.95 lagging. Find the total real power P drawn by the load in kW.
VL = 208 VIL = 20 Acos φ = 0.95
P = kW
18.Three-phase powerHard
A balanced three-phase load takes 200 kW at a power factor of 0.75 lagging from a 415 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.92 lagging. The real power stays the same. The capacitors are connected in Y. Find the capacitance Cph of each capacitor in µF.
P = 200 kWpf1 = 0.75pf2 = 0.92VL = 415 Vf = 60 Hz
Cph = µF
19.TransformersMedium
A 16 Ω resistor is connected across the secondary winding of an ideal transformer with a turns ratio N₁:N₂ = 10:1. Find the resistance R1′ seen looking into the primary winding.
N1:N2 = 10:1RL = 16 Ω
R1′ = Ω
20.TransformersHard
A single-phase 250 kVA transformer has a core loss of 1250 W and a copper loss of 3750 W at rated load. It supplies 75% of its rated kVA at a power factor of 0.95 lagging. Find the total losses Ploss in watts at this load.
Choose the feedback resistor Rf that gives this non-inverting amplifier a voltage gain of 3.
R1 = 2 kΩAv = 3
Rf = kΩ
22.Op-amp circuitsHard
The summing amplifier uses an ideal op-amp with ±15 V supplies. Find the output voltage Vout.
V1 = −2 VV2 = −1.5 VR1 = 47 kΩR2 = 2 kΩRf = 10 kΩ
Vout = V
23.Diodes & transistorsMedium
A 9.1 V Zener regulator is fed from 12 V through 330 Ω and supplies a 1500 Ω load. Find the Zener current IZ.
Vin = 12 VVZ = 9.1 VR = 330 ΩRL = 1500 Ω
IZ = mA
24.Diodes & transistorsHard
A 3.3 V Zener regulator must supply up to 30 mA to a load. The input can drop to 9 V, and the Zener needs at least 2 mA to regulate. Find the largest series resistance Rmax that keeps it regulating.
Simplify F = A′C + A′BC + ABC′ + A′B′C′ to its minimal sum-of-products form. How many literals L does the simplified expression contain?
F = A′C + A′BC + ABC′ + A′B′C′
L =
28.Digital logic: gates, K-maps & flip-flopsHard
A 4-bit binary up counter starts at 8 (decimal, Q = 1000). Which count Q (in decimal) does it show after 30 clock pulses?
Q0 = 830n = 4
Q =
29.Laplace transformsMedium
Find f(t) for F(s) = (4s + 28)/(s² + 2s + 1) and evaluate f(2).
F(s) = (4s + 28)/(s² + 2s + 1)t = 2 s
f(2) =
30.Laplace transformsHard
A system is described by the differential equation y″ + 7y′ + 6y = 2u′ + 12u, with input u(t) and output y(t). Find its transfer function G(s) = Y(s)/U(s) (zero initial conditions) and evaluate the impulse response g(t) at t = 0.5 s. Find g(0.5).
y″ + 7y′ + 6y = 2u′ + 12ut = 0.5 s
g(0.5) =
31.Block diagramsMedium
A plant G(s) = 24/(s + 3) is controlled in a negative feedback loop whose sensor has the gain H = 2. Find the time constant τ of the closed loop.
G(s) = 24/(s + 3)H = 2
τ = s
32.Block diagramsHard
The plant G(s) = 66/(s(s + 10)) is in a negative feedback loop with sensor gain H = 1. The closed-loop poles are complex. Find their real part σ.
G(s) = 66/(s(s + 10))H = 1
σ =
33.Step responseMedium
A system has the transfer function G(s) = 168/(s² + 5s + 56) and receives a unit step input. The poles are s = σ ± jωd. Find the real part σ.
G(s) = 168/(s² + 5s + 56)
σ =
34.Step responseHard
The step response of a second-order system without zeros shows 15 % overshoot, and the first peak occurs at t = 0.1 s. Find the natural frequency ωn.
%OS = 15 %tp = 0.1 s
ωn = rad/s
35.Bode plots & marginsMedium
The RC low-pass filter shown has R = 47 kΩ, C = 100 nF. A sinusoidal input of 340 Hz is applied. Find the phase shift φ of vout relative to vin, in degrees.
R = 47 kΩC = 100 nFf = 340 Hz
φ = °
36.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 16/(s(s + 1)(s + 5)). Find the phase crossover frequency ω180, where ∠L(jω) = −180°.
L(s) = 16/(s(s + 1)(s + 5))
ω180 = rad/s
37.Stability: Routh–Hurwitz & root locusMedium
The loop in the diagram uses positive feedback, with L(s) = 20/(s(s + 2)(s + 4)). How many closed-loop poles N lie in the right half-plane?
L(s) = 20/(s(s + 2)(s + 4))
N =
38.Stability: Routh–Hurwitz & root locusHard
The root locus of L(s) = K/(s(s + 10)) is shown. Find the gain K for which the closed-loop poles have the damping ratio ζ = 0.8.
L(s) = K/(s(s + 10))ζ = 0.8
K =
39.Steady-state error & PID controlMedium
The parabolic input r(t) = 1·t²/2 is applied to a unity-feedback loop with G(s) = 5(s + 3)/(s²(s + 4)). Find the steady-state error ess.
G(s) = 5(s + 3)/(s²(s + 4))r(t) = 1·t²/2
ess =
40.Steady-state error & PID controlHard
A proportional controller K drives the plant G(s) = 1/(s(s + 10)) in a unity-feedback loop. Find the gain K that gives the closed loop a damping ratio ζ = 0.5.
G(s) = 1/(s(s + 10))ζ = 0.5
K =
3Solutions
1.Series & parallel resistors
Answer: IR2 = 0.5043 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 20 + 6 = 26 Ω
R2 ∥ 26 = 12·26/(12+26) = 8.211 Ω
Req = R1 + 8.211 = 4 + 8.211 = 12.21 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 9/12.21 = 0.7371 A
Current through R₂
Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.
VA = V1 − IR1·R1 = 9 − 0.7371·4 = 6.052 V
IR2 = VA/R2 = 6.052/12 = 0.5043 A
Answer
IR2 = 0.5043 A
2.Series & parallel resistors
Answer: IR2 = 0.405 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 8 + 3 = 11 Ω
R4 ∥ 11 = 5.739 Ω
R3 + 5.739 = 11.74 Ω
R2 ∥ 11.74 = 7.397 Ω
Req = R1 + 7.397 = 20 + 7.397 = 27.4 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 30/27.4 = 1.095 A
Current through R₂
Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.
VA = V1 − IR1·R1 = 30 − 1.095·20 = 8.1 V
IR2 = VA/R2 = 8.1/20 = 0.405 A
Answer
IR2 = 0.405 A
3.Nodal analysis
Answer: Ix = 2.714 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Form a supernode
The voltage source between A and B carries an unknown current, so KCL cannot be written at A or B separately. Enclose A, B and the source in one supernode: the current entering it equals the current leaving it.
VB = VA + Vs = VA + 3
VA/R1 + VB/R2 = Is
Solve
VA/4 + (VA + 3)/3 = 4
VA = (4 − 3/3)/(1/4 + 1/3) = 5.143 V
VB = 5.143 + 3 = 8.143 V
Current through the voltage source
Everything that passes through the source from A to B leaves node B through R₂.
Ix = VB/R2 = 8.143/3 = 2.714 A
Answer
Ix = 2.714 A
A negative result means the real current flows against the arrow.
4.Nodal analysis
Answer: VB = 4.085 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Form a supernode
The voltage source between A and B carries an unknown current, so KCL cannot be written at A or B separately. Enclose A, B and the source in one supernode: the current entering it equals the current leaving it.
VB = VA − 6
(VA − V1)/R1 + VA/R2 + VB/R3 = Is
Solve
(VA − 12)/5 + VA/2 + (VA − 6)/12 = 5
VA·(1/5 + 1/2 + 1/12) = 5 + 12/5 + 6/12 = 7.9
VA = 7.9/0.7833 = 10.09 V
VB = 4.085 V
Answer
VB = 4.085 V
5.Mesh analysis
Answer: IR1 = 3.103 A
Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.
Assign mesh currents
Draw a clockwise current in each window: I1, I2. A resistor shared by two meshes carries the difference of their currents.
KVL around mesh 1
Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).
R1·I1 + R3(I1 − I2) = V1
4·I1 + 15(I1 − I2) = 30
19·I1 − 15·I2 = 30
KVL around mesh 2
Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).
R2·I2 + R3(I2 − I1) = −V2
6·I2 + 15(I2 − I1) = (−6)
−15·I1 + 21·I2 = −6
Solve
Δ = (19)(21) − (−15)(−15) = 174
I1 = Δ1/Δ = 540/174 = 3.103 A
I2 = Δ2/Δ = 336/174 = 1.931 A
Answer
IR1 = I1 = 3.103 A
A negative mesh current flows anticlockwise.
6.Mesh analysis
Answer: I1 = 0.5961 A
Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.
Assign mesh currents
Draw a clockwise current in each window: I1, I2, I3. A resistor shared by two meshes carries the difference of their currents.
KVL around mesh 1
Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).
R1·I1 + R4(I1 − I2) = V1
30·I1 + 12(I1 − I2) = 30
42·I1 − 12·I2 = 30
KVL around mesh 2
Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).
R2·I2 + R4(I2 − I1) + R5(I2 − I3) = 0
30·I2 + 12(I2 − I1) + 10(I2 − I3) = 0
−12·I1 + 52·I2 − 10·I3 = 0
KVL around mesh 3
Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).
R3·I3 + R5(I3 − I2) = −V2
4·I3 + 10(I3 − I2) = (−36)
−10·I2 + 14·I3 = −36
Solve
Δ = det of the coefficient matrix = 24360
I1 = Δ1/Δ = 14520/24360 = 0.5961 A
I2 = Δ2/Δ = −10080/24360 = −0.4138 A
I3 = Δ3/Δ = −69840/24360 = −2.867 A
Answer
I1 = 0.5961 A
A negative mesh current flows anticlockwise.
7.Superposition
Answer: VR2 = −17.03 V
Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.
Case 1 · V1 acting alone
Iₛ becomes an open circuit, so R₃ and R₄ form one series branch from A to ground, in parallel with R₂.
R3+R4 = 3+10 = 13 Ω
R2 ∥ (R3+R4) = 5·13/(5+13) = 3.611 Ω
VA = 24·3.611/(8+3.611) = 7.464 V
VB = VA·R4/(R3+R4) = 7.464·10/13 = 5.742 V
VR2′ = 0 − VA = 0 − 7.464 = −7.464 V
Case 2 · Is acting alone
V₁ becomes a short, so R₁ is in parallel with R₂. Iₛ splits at B between R₄ and the path through R₃.
R1 ∥ R2 = 8·5/(8+5) = 3.077 Ω
Req = R4 ∥ (R3+R1∥R2) = 10 ∥ 6.077 = 3.78 Ω
VB = Is·Req = 5·3.78 = 18.9 V
VA = VB·(R1∥R2)/(R3+R1∥R2) = 18.9·3.077/6.077 = 9.569 V
VR2″ = 0 − VA = 0 − 9.569 = −9.569 V
Add the contributions
VR2 = VR2′ + VR2″
VR2 = (−7.464) + (−9.569) = −17.03 V
A negative result means the real polarity is opposite to the one marked.
8.Superposition
Answer: IR4 = −0.3226 A
Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.
Case 1 · V1 acting alone
V₂ becomes a short and Iₛ an open circuit. Seen from A, R₃ is in parallel with the series pair R₂+R₄.
R3 ∥ (R2+R4) = 12 ∥ 27 = 8.308 Ω
VA = 24·8.308/(6+8.308) = 13.94 V
VB = VA·R4/(R2+R4) = 13.94·15/27 = 7.742 V
IR4′ = (VB − V2)/R4 = (7.742 − 0)/15 = 0.5161 A
Case 2 · Is acting alone
Both voltage sources become shorts. Iₛ splits at B between R₄ (now to ground) and R₂ in series with R₁ ∥ R₃.
R1 ∥ R3 = 4 Ω, so the left path is R2+4 = 16 Ω
Req = R4 ∥ 16 = 7.742 Ω
VB = Is·Req = (−0.5)·7.742 = −3.871 V
VA = VB·4/16 = −0.9677 V
IR4″ = (VB − V2)/R4 = (−3.871 − 0)/15 = −0.2581 A
Case 3 · V2 acting alone
V₁ becomes a short and Iₛ an open circuit. R₁ ∥ R₃ hangs from A, in series with R₂ back to B.
R1 ∥ R3 = 6·12/(6+12) = 4 Ω
VB = V2·(R2+R1∥R3)/(R4+R2+R1∥R3) = 18·16/31 = 9.29 V
VA = VB·(R1∥R3)/(R2+R1∥R3) = 9.29·4/16 = 2.323 V
IR4‴ = (VB − V2)/R4 = (9.29 − 18)/15 = −0.5806 A
Add the contributions
IR4 = IR4′ + IR4″ + IR4‴
IR4 = 0.5161 + (−0.2581) + (−0.5806) = −0.3226 A
A negative result means the real current flows against the arrow.
9.Thévenin & Norton
Answer: IN = 0.3846 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 4·3/(4+3) = 1.714 Ω
Rth = (R1 ∥ R2) + R3 = 1.714 + 15 = 16.71 Ω
Find Vth, the open-circuit voltage
With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.
Vth = V1·R2/(R1+R2) = 15·3/(4+3) = 6.429 V
Norton equivalent
A Norton source is the same circuit seen as a current source in parallel with R_th. Its current is the short-circuit current at a–b.
IN = Vth/Rth = 6.429/16.71 = 0.3846 A
10.Thévenin & Norton
Answer: IL = 0.4007 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 25·30/(25+30) = 13.64 Ω
Rth = (R1 ∥ R2) + R3 = 13.64 + 25 = 38.64 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 8.182 + 0.5·13.64 = 15 V
Vth = VB = VA + Is·R3 = 15 + 0.5·25 = 27.5 V
Connect the load to the Thévenin equivalent
The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.
IL = Vth/(Rth + RL) = 27.5/(38.64 + 30) = 0.4007 A
11.RC & RL transients
Answer: W(∞) = 48 mJ
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant and final current
Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.
τ = L/R = 150 mH / 15 Ω = 10 ms
i(∞) = Vs/R = 12/15 = 0.8 A
Stored energy
W(∞) = ½·L·i(∞)² = ½·150·0.8² = 48 mJ
Answer
W(∞) = 48 mJ
12.RC & RL transients
Answer: t = 47.13 ms
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
The capacitor voltage cannot jump, so it starts at its stored value and heads for the source voltage.
t = τ·ln((20 − 10)/(15 − 10)) = 68·ln(2) = 47.13 ms
Answer
t = 47.13 ms
13.AC impedance & phasors
Answer: cos φ = 0.5635
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
XL = 12.57 Ω, XC = 159.2 Ω
Impedance
|Z| = √(100² + (−146.6)²) = 177.4 Ω
Power factor
cos φ = R/|Z| = 100/177.4 = 0.5635
The circuit is capacitive, so the power factor is leading.
Answer
cos φ = 0.5635
14.AC impedance & phasors
Answer: I = 1.632 A
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactance
XC = 1/(2π·100·10·10⁻⁶) = 159.2 Ω
Parallel combination
Multiply top and bottom by the complex conjugate to split Zp into real and imaginary parts.
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Line current
Only the real part of the power does work, so divide by the power factor.
I = P/(V·cos φ) = 27000/(230·0.65) = 180.6 A
Answer
I = 180.6 A
16.AC power & power factor
Answer: Inew = 155.3 A
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = P·tan φ1 = 35·tan(41.41°) = 30.87 kvar
Q2 = P·tan φ2 = 35·tan(11.48°) = 7.107 kvar
QC = Q1 − Q2 = 23.76 kvar
New line current
Inew = P/(V·cos φ2) = 35000/(230·0.98) = 155.3 A
Answer
Inew = 155.3 A
17.Three-phase power
Answer: P = 6.845 kW
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Apparent power
S = √3·VL·IL = √3·208·20 = 7.205 kVA
Real power
P = S·cos φ = 7.205·0.95 = 6.845 kW
Answer
P = 6.845 kW
18.Three-phase power
Answer: Cph = 1404 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 200·tan(acos 0.75) = 200·0.8819 = 176.4 kvar
Q2 = 200·tan(acos 0.92) = 200·0.426 = 85.2 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 91.18 kvar
Capacitance per phase
In a Y bank each capacitor is connected between a line and the star point.
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Referred resistance
The voltage goes up by a and the current down by a, so the ratio V/I goes up by a².
R1′ = a²·RL = 10²·16 = 1600 Ω
Answer
R1′ = 1600 Ω
20.Transformers
Answer: Ploss = 3359 W
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.
Copper loss at this load
Pcu = x²·Pcu,fl = 0.5625·3750 = 2109 W
Total losses
The core loss is the same at any load.
Ploss = 1250 + 2109 = 3359 W
Answer
Ploss = 3359 W
The efficiency at this load is η = 98.15%.
21.Op-amp circuits
Answer: Rf = 4 kΩ
Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.
Gain of a non-inverting amplifier
V₋ = V₊ = Vin, and the current through R₁ also flows through Rf, so Vout = Vin·(1 + Rf/R₁).
Av = 1 + Rf/R1
Rf = (3 − 1)·2 = 4 kΩ
Answer
Rf = 4 kΩ
22.Op-amp circuits
Answer: Vout = 7.926 V
Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.
Input currents
V₋ = 0, so each input resistor has its full input voltage across it.
I1 = V1/R1 = −2/47 = −0.04255 mA
I2 = V2/R2 = −1.5/2 = −0.75 mA
If = I1 + I2 = −0.7926 mA
Output voltage
Vout = −Rf·If = −10·(−0.7926) = 7.926 V
Answer
Vout = 7.926 V
23.Diodes & transistors
Answer: IZ = 2.721 mA
Zener regulator: a reverse-biased Zener diode holds its voltage VZ while its current stays above a minimum IZ,min. The series resistor R takes the difference between input and output: IR = (Vin − VZ)/R. That current splits between the load, IL = VZ/RL, and the Zener: IZ = IR − IL. Design for the worst cases: the lowest input with the largest load must still leave IZ,min, and the highest input with no load gives the largest Zener power PZ = VZ·IZ.
Resistor current
IR = 2.9/330 = 8.788 mA
Load current
IL = 9.1/1500 = 6.067 mA
Zener current
IZ = 8.788 − 6.067 = 2.721 mA
Answer
IZ = 2.721 mA
24.Diodes & transistors
Answer: Rmax = 178.1 Ω
Zener regulator: a reverse-biased Zener diode holds its voltage VZ while its current stays above a minimum IZ,min. The series resistor R takes the difference between input and output: IR = (Vin − VZ)/R. That current splits between the load, IL = VZ/RL, and the Zener: IZ = IR − IL. Design for the worst cases: the lowest input with the largest load must still leave IZ,min, and the highest input with no load gives the largest Zener power PZ = VZ·IZ.
Worst-case current
IR = 30 + 2 = 32 mA
Largest resistance
Rmax = 5.7/0.032 = 178.1 Ω
Answer
Rmax = 178.1 Ω
25.Number systems
Answer: N = −83
Positional number systems: each digit is worth its value times a power of the base. In binary the places are worth 1, 2, 4, 8, 16, …; in hexadecimal 1, 16, 256, …, with A–F standing for 10–15. In 8-bit two's complement the leftmost bit is worth −128 instead of +128, which is how negative numbers are stored.
Add the place values
The other bits keep their normal positive values.
−128 + 32 + 8 + 4 + 1 = −83
Answer
N = −83
26.Number systems
Answer: R = 96
Setting bits: each bit is worth a power of two (128, 64, …, 1). One hex digit is exactly four bits, and in 8-bit two's complement the leftmost bit is worth −128. Bitwise operations work on each bit position separately.
Bit by bit
Shifting left by 3 moves every bit 3 places to the left; bits that fall off the left end are lost and zeros come in on the right.
1110 1100 << 3
= 0110 0000
Value of the result
0110 0000₂ = 96
Answer
R = 96
27.Digital logic: gates, K-maps & flip-flops
Answer: L = 7
Boolean algebra: the rules that simplify expressions are X + X′ = 1 and X·X′ = 0, X + X = X, absorption X + X·Y = X, the combining rule X·Y + X·Y′ = X, X + X′Y = X + Y and the consensus theorem XY + X′Z + YZ = XY + X′Z. De Morgan's laws turn (X·Y)′ into X′ + Y′ and (X + Y)′ into X′·Y′. A Karnaugh map applies these rules graphically: every group of two neighbouring cells is one use of XY + XY′ = X.
Minterms of the expression
A′C → m(1, 3)
A′BC → m(3)
ABC′ → m(6)
A′B′C′ → m(0)
Group and read off
F = A′C + A′B′ + ABC′
Count the literals
L = 7
Answer
L = 7
28.Digital logic: gates, K-maps & flip-flops
Answer: Q = 6
Flip-flops and counters: a flip-flop changes only at the active clock edge. D copies its input (Q⁺ = D); T toggles when T = 1; JK holds for 00, resets for 01, sets for 10 and toggles for 11. An n-bit binary counter has 2ⁿ states and counts modulo 2ⁿ; a mod-N counter goes 0, 1, …, N − 1 and back to 0, and needs the smallest n with 2ⁿ ≥ N flip-flops. Each stage of a ripple counter halves the frequency, so the last output of a mod-N counter runs at fclk/N. A Johnson counter of n flip-flops has 2n states, a ring counter n.
Full cycles
Every 16 pulses bring the counter back to the same state.
30 = 1·16 + 14
Count after the remaining pulses
Q = (8 + 14) mod 16 = 6
Q = 0110₂
Answer
Q = 6
29.Laplace transforms
Answer: f(2) = 7.037
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Factor the denominator
s² + 2s + 1 = (s + 1)²
Partial fractions
4s + 28 = 4(s + 1) + 24
F(s) = 4/(s + 1) + 24/(s + 1)²
Inverse transform
f(t) = 4·e−t + 24·t·e−t
f(2) = (4 + 24·2)·e−2 = 7.037
Answer
f(2) = 7.037
30.Laplace transforms
Answer: g(0.5) = 1.213
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transfer function
G(s) = Y(s)/U(s) = (2s + 12)/(s² + 7s + 6)
Partial fractions
s² + 7s + 6 = (s + 1)(s + 6)
A = 2, B = 0
Impulse response
g(t) = 2·e−t
g(0.5) = 1.213
Answer
g(0.5) = 1.213
31.Block diagrams
Answer: τ = 0.01961 s
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Characteristic equation
s(s + 10) + 66·1 = 0 → s² + 10s + 66 = 0
Roots
s = −5 ± j·√(66 − 25) = −5 ± j6.403
σ = −5
Answer
σ = −5
33.Step response
Answer: σ = −2.5
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 56 → ωₙ = 7.483 rad/s
2ζωₙ = 5 → ζ = 5/(2·7.483) = 0.3341
Result
σ = −ζωₙ = −5/2 = −2.5
Answer
σ = −2.5
34.Step response
Answer: ωn = 36.7 rad/s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Corner frequency
ωc = 1/(RC) = 1/(47000·1 × 10⁻⁷) = 212.8 rad/s
fc = 33.86 Hz → f/fc = 340/33.86 = 10.04
Phase
φ = − atan(10.04) = −84.31°
Answer
φ = −84.31°
36.Bode plots & margins
Answer: ω180 = 2.236 rad/s
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Phase crossover
(ω/1)·(ω/5) = 1 → ω180 = √(1·5) = 2.236 rad/s
Answer
ω180 = 2.236 rad/s
37.Stability: Routh–Hurwitz & root locus
Answer: N = 1
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
Characteristic polynomial
s³ + 6s² + 8s − 20 = 0
Routh array
s³: 1, 8
s²: 6, −20
s¹: 11.33
s⁰: −20
Sign changes in the first column
1 → 6 → 11.33 → −20
N = 1
Answer
N = 1
Positive feedback makes the constant coefficient negative: one real pole always moves into the right half-plane.
38.Stability: Routh–Hurwitz & root locus
Answer: K = 39.06
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Compare with the standard form
s² + 10s + K = s² + 2ζωₙs + ωₙ²
2·0.8·ωₙ = 10 → ωₙ = 6.25 rad/s
Gain
K = ωₙ² = 6.25² = 39.06
Answer
K = 39.06
The closed-loop poles sit where the ζ line crosses the vertical branch at s = −5.
39.Steady-state error & PID control
Answer: ess = 0.2667
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Acceleration constant
Ka = 5·3/4 = 3.75
Parabola error
ess = 1/3.75 = 0.2667
Answer
ess = 0.2667
40.Steady-state error & PID control
Answer: K = 100
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
s(s + 10) + 1K = s² + 10s + 1K
Natural frequency
2·0.5·ωₙ = 10 → ωₙ = 10 rad/s
Gain
1K = ωₙ² = 100 → K = 100
Answer
K = 100
This is independent practice material. ExamProblems is not affiliated with or endorsed by the organisation that runs this exam, and the exam name is used only to describe the content. The FE exam is run by NCEES, which is not affiliated with ExamProblems and does not endorse it.