Series & parallel resistors

Resistors in series
Req = R1 + R2 + …
Resistors in parallel
1/Req = 1/R1 + 1/R2 + …
Two in parallel
Req = R1R2 / (R1 + R2)
Ohm's law
V = I·R
Power
P = V·I = I²R = V²/R

Method

  1. Start at the end of the network furthest from the terminals.
  2. Combine resistors in series by adding them, and resistors in parallel with 1/R = 1/R₁ + 1/R₂ + …
  3. Redraw the circuit after each step.
  4. Repeat until one resistor is left between the terminals.

Nodal analysis

Kirchhoff’s current law
ΣIin = ΣIout
Branch current
I = (Va − Vb)/R
Reference node
Vground = 0

Method

  1. Choose a reference node (ground) and label the other node voltages.
  2. Write Kirchhoff’s current law at every unknown node: currents leaving through each branch equal the currents entering.
  3. Express every branch current as (Va − Vb)/R.
  4. Solve the system of equations, then find any current you need.

Mesh analysis

Kirchhoff’s voltage law
ΣV = 0 around every loop
Shared resistor
current = I1 − I2
Current source in a mesh
fixes that mesh current

Method

  1. Draw a clockwise current in every mesh (window) of the circuit.
  2. Apply Kirchhoff’s voltage law around each mesh: the sum of voltage drops is zero.
  3. In a resistor shared by two meshes the current is the difference of the two mesh currents.
  4. Solve the equations; a negative result means the current flows the other way.

Superposition

Superposition
x = x1 + x2 + … (one source at a time)
Switched-off voltage source
short circuit (0 V)
Switched-off current source
open circuit (0 A)
Voltage divider
V2 = V·R2/(R1 + R2)
Current divider
I1 = I·R2/(R1 + R2)

Method

  1. Count the independent sources. You will solve one simpler circuit per source.
  2. Keep one source and switch off the others: a voltage source becomes a short circuit (a wire), a current source becomes an open circuit (a gap).
  3. Solve the simpler circuit for the voltage or current you need, keeping track of its direction.
  4. Repeat for every source, then add the contributions with their signs.

Thévenin & Norton

Thévenin voltage
Vth = Vopen circuit
Thévenin resistance
Rth: all sources off, seen from a–b
Norton current
IN = Vth/Rth
Load current
IL = Vth/(Rth + RL)
Maximum power transfer
RL = Rth, Pmax = Vth²/(4Rth)

Method

  1. Remove the load and mark the two terminals a and b.
  2. Find the open-circuit voltage between a and b: this is Vth.
  3. Switch off all independent sources and find the resistance seen from a–b: this is Rth.
  4. Put the load back on the equivalent circuit: Vth in series with Rth.
  5. For the Norton equivalent, convert: IN = Vth/Rth, with RN = Rth in parallel.

RC & RL transients

Time constant
τ = RC | τ = L/R
Response
x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ
Capacitor at DC
open circuit; vC cannot jump
Inductor at DC
short circuit; iL cannot jump
Settled
t ≈ 5τ

Method

  1. Find the initial value just after switching: a capacitor voltage and an inductor current cannot jump.
  2. Find the final value long after switching: a capacitor acts as an open circuit, an inductor as a short circuit.
  3. Find the time constant: τ = RC or τ = L/R, using the resistance seen by the capacitor or inductor.
  4. Use x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ.

AC impedance & phasors

Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z

Method

  1. Convert the frequency: ω = 2πf.
  2. Find each reactance: XL = ωL and XC = 1/(ωC).
  3. Add impedances like resistors, with Z = R + jX.
  4. Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.

AC power & power factor

Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)

Three-phase power

Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η

Transformers

Turns ratio
a = N1/N2 = V1/V2
Current ratio
I1/I2 = N2/N1 = 1/a
Rated current
I = S/V
Referred impedance
Z1′ = a²·ZL
Copper loss at part load
Pcu = x²·Pcu,fl
Efficiency
η = x·S·pf/(x·S·pf + Pcore + x²·Pcu,fl)
Maximum efficiency
x = √(Pcore/Pcu,fl)

Op-amp circuits

Inverting amplifier
Vout = −(Rf/Rin)·Vin
Non-inverting amplifier
Vout = (1 + Rf/R1)·Vin
Summing amplifier
Vout = −Rf(V1/R1 + V2/R2)
Ideal op-amp
V+ = V−, Iin = 0

Diodes & transistors

Diode (constant drop)
VD = 0.7 V when conducting
Active region
VBE = 0.7 V, IC = β·IB, IE = (β + 1)·IB
Fixed bias
IB = (VCC − 0.7)/RB
Divider bias
IB = (VTH − 0.7)/(RTH + (β + 1)RE)
Thévenin of the divider
VTH = VCC·R2/(R1 + R2), RTH = R1∥R2
Collector loop
VCE = VCC − ICRC − IERE
Saturation
IC(sat) = (VCC − VCE(sat))/RC, IB ≥ IC(sat)/β

Number systems

Place values
binary 2k, octal 8k, hex 16k
To decimal
Σ dk·bk
From decimal
divide by the base, read the remainders bottom-up
Hex ↔ binary
one hex digit = 4 bits
Two’s complement
invert the bits and add 1

Digital logic: gates, K-maps & flip-flops

Basic gates
A·B, A + B, A′, (A·B)′, (A + B)′, A ⊕ B
Boolean rules
X + X′ = 1, X·X′ = 0, X + XY = X, XY + XY′ = X
De Morgan
(X·Y)′ = X′ + Y′, (X + Y)′ = X′·Y′
Karnaugh map order
00, 01, 11, 10 (Gray code)
Group of 2ᵏ cells
loses k variables
4-to-1 multiplexer
F = A′B′I0 + A′BI1 + AB′I2 + ABI3
Flip-flops
D: Q⁺ = D, T: Q⁺ = T ⊕ Q, JK: Q⁺ = JQ′ + K′Q
Counters
n-bit: 2ⁿ states; mod-N: smallest n with 2ⁿ ≥ N; fout = fclk/N
Ripple counter
fmax = 1/(n·tpd)
Ring and Johnson counters
n and 2n states

Method

  1. For a circuit, work from the inputs to the output one gate at a time and write the value on every wire, or write its expression and fill in the truth table.
  2. For simplification, put the 1s (and the don’t-cares as X) into a Karnaugh map with Gray-code rows and columns: 00, 01, 11, 10.
  3. Cover the 1s with as few and as large groups of 1, 2, 4, 8 or 16 cells as possible, wrapping round the edges; each group is one product term made of the variables that stay constant. Group the 0s for the POS form.
  4. For flip-flops and counters, read the inputs at each active clock edge, write the state after every edge, and remember that an n-bit counter wraps round after 2ⁿ states.

Stability: Routh–Hurwitz & root locus

Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)

Method

  1. Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
  2. Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
  3. Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
  4. For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.

Steady-state error & PID control

System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)

Method

  1. Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
  2. Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
  3. Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
  4. For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².

2Practice problems

1.Series & parallel resistorsMedium
R1​ = 3 ΩR3​ = 8 Ω+−V1​18 VR2​8 ΩIR2​AR4​10 ΩB

Find the current IR2 through R2.

V1 = 18 VR1 = 3 ΩR2 = 8 ΩR3 = 8 ΩR4 = 10 Ω
IR2 = A
2.Series & parallel resistorsHard
R1​ = 5 ΩIR1​R3​ = 12 ΩR5​ = 4 Ω+−V1​24 VR2​6 ΩAR4​30 ΩBR6​6 Ω

Find the current IR1 delivered by the source, which flows through R1.

V1 = 24 VR1 = 5 ΩR2 = 6 ΩR3 = 12 ΩR4 = 30 ΩR5 = 4 ΩR6 = 6 Ω
IR1 = A
3.Nodal analysisMedium
R1​3 Ω+−V1​24 VR2​12 Ω+−V2​12 VR3​3 ΩI3​A

Three branches are connected between node A and ground, as shown. Use nodal analysis to find the current I3 in branch 3, flowing up into node A in the direction of the arrow.

V1 = 24 VR1 = 3 ΩV2 = 12 VR2 = 12 ΩR3 = 3 Ω
I3 = A
4.Nodal analysisHard
R1​ = 30 ΩR3​ = 8 Ω+−V1​15 VR2​5 ΩAR4​6 ΩBIs​?

The current source is adjusted until the node voltage at A is VA = 2.5 V. Use nodal analysis to find the source current Is (direction as shown).

V1 = 15 VR1 = 30 ΩR2 = 5 ΩR3 = 8 ΩR4 = 6 ΩVA = 2.5 V
Is = A
5.Mesh analysisMedium
R1​ = 12 ΩR2​ = 10 ΩIR2​+−V1​6 VR3​4 ΩA+−V2​12 VI1​I2​

Use mesh analysis to find the current IR2 through R2 in the direction of the arrow.

V1 = 6 VV2 = 12 VR1 = 12 ΩR2 = 10 ΩR3 = 4 Ω
IR2 = A
6.Mesh analysisHard
R1​ = 8 ΩR2​ = 12 ΩR3​ = 25 Ω+−V1​15 VR4​4 ΩAR5​6 Ω+−VR5​B+−V2​12 VI1​I2​I3​

Use mesh analysis to find the voltage VR5 across R5 with the polarity shown.

V1 = 15 VV2 = 12 VR1 = 8 ΩR2 = 12 ΩR3 = 25 ΩR4 = 4 ΩR5 = 6 Ω
VR5 = V
7.SuperpositionMedium
linear circuitVs​Is​IRL​

A linear resistive circuit contains one voltage source Vs and one current source Is. The current I through a load resistor is measured twice: with Vs = 20 V and Is = 1 mA, I = 12.25 mA; with Vs = 15 V and Is = 5 mA, I = 10.25 mA. Find the load current I when Vs = 2 V and Is = 6 mA.

20 V, 1 mA → 12.25 mA15 V, 5 mA → 10.25 mAVs = 2 V, Is = 6 mA
I = mA
8.SuperpositionHard
R1​ = 8 ΩR2​ = 2 Ω+−VR2​R4​ = 30 Ω+−V1​30 VR3​2 ΩAIs​0.5 AB+−V2​15 V

Use superposition to find the voltage VR2 across R2 with the polarity shown.

V1 = 30 VIs = 0.5 AV2 = 15 VR1 = 8 ΩR2 = 2 ΩR3 = 2 ΩR4 = 30 Ω
VR2 = V
9.Thévenin & NortonMedium
R1​ = 5 ΩR3​ = 20 Ω+−V1​15 VR2​20 ΩAab

Find the Norton current IN: the current that flows from a to b if the terminals are shorted.

V1 = 15 VR1 = 5 ΩR2 = 20 ΩR3 = 20 Ω
IN = A
10.Thévenin & NortonHard
R1​ = 2 ΩR3​ = 30 Ω+−V1​12 VR2​25 ΩAIs​2.5 ABab

Find the Thévenin voltage Vth seen from terminals a–b.

V1 = 12 VIs = 2.5 AR1 = 2 ΩR2 = 25 ΩR3 = 30 Ω
Vth = V
11.RC & RL transientsMedium
+−Vs​15 Vt = 0R = 100 ΩL150 mHi(t)

The inductor carries no current before the switch closes at t = 0. Find the current i at t = 2 ms.

Vs = 15 VR = 100 ΩL = 150 mHt = 2 ms
i = A
12.RC & RL transientsHard
+−Vs​12 VR1​ = 20 ΩR2​ = 20 Ωcloses at t = 0L33 mHi(t)

The switch across R2 has been open for a long time, so the inductor current is steady. At t = 0 the switch closes and shorts out R2. How long after t = 0 does the inductor current reach 0.42 A? Find t.

Vs = 12 VR1 = 20 ΩR2 = 20 ΩL = 33 mH
t = ms
13.AC impedance & phasorsMedium
50 V500 HzR = 60 ΩL = 100 mHC = 100 µF

A series RLC circuit is connected to a 50 V (rms), 500 Hz supply. Find the phase angle φ of the impedance, in degrees (positive when the current lags the voltage).

V = 50 V (rms)f = 500 HzR = 60 ΩL = 100 mHC = 100 µF
φ = °
14.AC impedance & phasorsHard
VfR = 10 ΩL = 10 mHC = 0.22 µF

A series RLC circuit has R = 10 Ω, L = 10 mH and C = 0.22 µF. Find its quality factor Q at resonance.

R = 10 ΩL = 10 mHC = 0.22 µF
Q =
15.AC power & power factorMedium
P = 40 kWQ = ?Sφ

A single-phase motor takes 40 kW at a power factor of 0.9 lagging from a 240 V supply. Find the reactive power Q it draws.

P = 40 kWpf = 0.9V = 240 V
Q = kvar
16.AC power & power factorHard
400 V60 Hzload13 kW, 0.65C220 µFI

A single-phase load takes 13 kW at a power factor of 0.65 lagging from a 400 V, 60 Hz supply. A 220 µF capacitor is connected in parallel with the load. Find the new power factor cos φ seen by the supply.

P = 13 kWpf1 = 0.65V = 400 Vf = 60 HzC = 220 µF
cos φ =
17.Three-phase powerMedium
ABCVL​ = 208 VIL​ = 75 Acos φ = 0.88lagging

A balanced three-phase load draws a line current of 75 A from a supply with a line-to-line voltage of 208 V. The power factor is 0.88 lagging. Find the total real power P drawn by the load in kW.

VL = 208 VIL = 75 Acos φ = 0.88
P = kW
18.Three-phase powerHard
P = 60 kWφ1​S1​Q2​QC​

A balanced three-phase load takes 60 kW at a power factor of 0.8 lagging from a 415 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.9 lagging. The real power stays the same. The capacitors are connected in Y. Find the capacitance Cph of each capacitor in µF.

P = 60 kWpf1 = 0.8pf2 = 0.9VL = 415 Vf = 50 Hz
Cph = µF
19.TransformersMedium
8 ΩN1​N2​128 Ω

An amplifier with an output resistance of 128 Ω drives an 8 Ω loudspeaker through an ideal transformer. For maximum power transfer the loudspeaker must look like 128 Ω from the amplifier. Find the turns ratio a = N₁/N₂.

Rs = 128 ΩRL = 8 Ω
a =
20.TransformersHard
pf 0.850 kVA, η = 98%

A single-phase 50 kVA transformer has a core loss of 400 W. At rated load and a power factor of 0.8 lagging its efficiency is 98%. Find the full-load copper loss Pcu,fl in watts.

S = 50 kVAPcore = 400 Wpf = 0.8η = 98%
Pcu,fl = W
21.Op-amp circuitsMedium
−+Vout​Rf​ = ?R1​ = 2 kΩVin​

Choose the feedback resistor Rf that gives this non-inverting amplifier a voltage gain of 31.

R1 = 2 kΩAv = 31
Rf = kΩ
22.Op-amp circuitsHard
−+Vout​R2​ = 2 kΩV1​ = 0.6 VR1​ = 22 kΩV2​ = −0.6 VR3​ = 4.7 kΩR4​ = 100 kΩ

The op-amp is ideal and runs from ±15 V supplies. The resistor ratios are not matched. Find the output voltage Vout.

V1 = 0.6 VV2 = −0.6 VR1 = 22 kΩR2 = 2 kΩR3 = 4.7 kΩR4 = 100 kΩ
Vout = V
23.Diodes & transistorsMedium
RC​ = 3.3 kΩβ = 120IC​ = ?VCC​ = 15 VRB​ = 470 kΩ

An NPN transistor with β = 120 is biased by a base resistor RB = 470 kΩ from the supply VCC = 15 V. The collector resistor is RC = 3.3 kΩ and the emitter is grounded. Take VBE = 0.7 V and assume the transistor is in the active region. Find the collector current IC in mA.

VCC = 15 VRB = 470 kΩRC = 3.3 kΩβ = 120VBE = 0.7 V
IC = mA
24.Diodes & transistorsHard
RC​ = 100 Ωβ = 50VCC​ = 5 V5 VRB​ = ?

An NPN transistor with β = 50 switches a 100 Ω load resistor connected between VCC = 5 V and its collector. The emitter is grounded. The base is driven from a 5 V logic output through a base resistor RB. Take VBE = 0.7 V and VCE(sat) = 0.2 V. Find the largest base resistor RB, in kΩ, that still drives the transistor just into saturation.

VCC = 5 VRC = 100 Ωβ = 50Vin = 5 VVBE = 0.7 VVCE(sat) = 0.2 V
RB = kΩ
25.Number systemsMedium
8-bit two's complement0−12806403201608040201

Set the bits so they store −6 in 8-bit two's complement. Read as an unsigned number, what is the pattern's value U?

N = −68 bit
U =
26.Number systemsHard
click the bits to set them012806403201608040201

Set the bits to the 8-bit result of 1010 1111 >> 3. What is the result's value R in decimal?

1010 1111>> 3
R =
27.Digital logic: gates, K-maps & flip-flopsMedium
ABCD000111100001111000111312040517160120130150141809011110

Use the Karnaugh map to find the minimal product-of-sums (POS) form of F(A, B, C, D) = Σm(1, 2, 3, 6, 7, 8, 10). How many sum terms (factors) N does it have?

F(A, B, C, D) = Σm(1, 2, 3, 6, 7, 8, 10)
N =
28.Digital logic: gates, K-maps & flip-flopsHard
CLKJK1234567

A positive-edge-triggered JK flip-flop starts with Q = 0 and receives the inputs shown at 7 rising clock edges. How many times N does Q change state?

Q₀ = 0JK
N =
29.Laplace transformsMedium
ReIm−1−2−3−4−5−6−7−8−91

F(s) = (4s + 31)/(s² + 15s + 56). Its inverse transform has the form f(t) = A·e−7t + B·e−8t. Find the coefficient A by partial fractions.

F(s) = (4s + 31)/(s² + 15s + 56)
A =
30.Laplace transformsHard
t (s)y(t)t = 0.1y(0.1) = ?

A system obeys y″ + 9y′ + 20y = 60·u(t), with y(0) = 1 and y′(0) = 0. At t = 0 a step input u(t) = 1 is applied. Use the Laplace transform to find y(0.1).

y″ + 9y′ + 20y = 60·u(t)y(0) = 1y′(0) = 0u(t) = 1t = 0.1 s
y(0.1) =
31.Block diagramsMedium
R(s)+10K+1s + 5G(s)C(s)4H₁−−

The plant G(s) = 1/(s + 5) has an inner (minor) negative feedback loop with gain H₁ = 4. A controller gain K = 10 and an outer unity negative feedback loop close the system. Find the closed-loop DC gain T(0).

G(s) = 1/(s + 5)H₁ = 4K = 10
T(0) =
32.Block diagramsHard
R(s)+Kcontroller+D(s)+8s + 8plantC(s)−

A proportional controller K drives the plant G(s) = 8/(s + 8) in a unity negative feedback loop. A disturbance step of size 5 enters at the plant input while R = 0. Find the smallest gain K that keeps the steady-state output at or below 0.05.

G(s) = 8/(s + 8)D = 5css ≤ 0.05
K =
33.Step responseMedium
t (s)y(t)1?

A system has the transfer function G(s) = 35/(s² + 6s + 35) and receives a unit step input. Find the percent overshoot %OS of the step response.

G(s) = 35/(s² + 6s + 35)
%OS = %
34.Step responseHard
t (s)y(t)1tp​ = 0.8 s15 %

The step response of a second-order system without zeros shows 15 % overshoot, and the first peak occurs at t = 0.8 s. Find the natural frequency ωn.

%OS = 15 %tp = 0.8 s
ωn = rad/s
35.Bode plots & marginsMedium
|H| (dB)0.1110100−40−2002040ω (rad/s)ω = 10

Find the exact magnitude |G(jω)| of G(s) = 756/((s + 7)(s + 9)) at ω = 10 rad/s, in dB.

G(s) = 756/((s + 7)(s + 9))ω = 10 rad/s
|G(jω)| = dB
36.Bode plots & marginsHard
|H| (dB)0.10.1111010100100−80−60−40−2002040ω (rad/s)φ (°)ω (rad/s)−270−180−900ω180​

A unity-feedback loop has the open-loop transfer function L(s) = 308/(s(s + 6)(s + 7)). Find the gain margin GM in dB.

L(s) = 308/(s(s + 6)(s + 7))
GM = dB
37.Stability: Routh–Hurwitz & root locusMedium
R(s)+K1(s + 2)(s + 5)(s + 6)C(s)−

A unity-feedback loop has L(s) = K/((s + 2)(s + 5)(s + 6)), with K > 0. Find the largest gain Kmax for which the closed loop is stable.

L(s) = K/((s + 2)(s + 5)(s + 6))
Kmax =
38.Stability: Routh–Hurwitz & root locusHard
ReImζ = 0.4−5j5

The root locus of L(s) = K/(s(s + 5)) is shown. Find the gain K for which the closed-loop poles have the damping ratio ζ = 0.4.

L(s) = K/(s(s + 5))ζ = 0.4
K =
39.Steady-state error & PID controlMedium
r(t) = 10·t²/2+5(s + 2)s²(s + 10)C(s)−

The parabolic input r(t) = 10·t²/2 is applied to a unity-feedback loop with G(s) = 5(s + 2)/(s²(s + 10)). Find the steady-state error ess.

G(s) = 5(s + 2)/(s²(s + 10))r(t) = 10·t²/2
ess =
40.Steady-state error & PID controlHard
R(s)+K = 2010s(s + 6)C(s)−

A proportional controller K = 20 drives the plant G(s) = 10/(s(s + 6)) in a unity-feedback loop. Find the 2 % settling time ts of the step response, using ts ≈ 4/(ζωₙ).

G(s) = 10/(s(s + 6))K = 20
ts = s

3Solutions

1.Series & parallel resistors

Answer: IR2 = 1.459 A

Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.

R1​ = 3 ΩR3​ = 8 Ω+−V1​18 VR2​8 ΩAR4​10 ΩB

Combine resistors from the far end

Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.

R3 + R4 = 8 + 10 = 18 Ω
R2 ∥ 18 = 8·18/(8+18) = 5.538 Ω
Req = R1 + 5.538 = 3 + 5.538 = 8.538 Ω

Current from the source

The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.

IR1 = V1/Req = 18/8.538 = 2.108 A

Current through R₂

Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.

VA = V1 − IR1·R1 = 18 − 2.108·3 = 11.68 V
IR2 = VA/R2 = 11.68/8 = 1.459 A

Answer

IR2 = 1.459 A
2.Series & parallel resistors

Answer: IR1 = 2.503 A

Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.

R1​ = 5 ΩR3​ = 12 ΩR5​ = 4 Ω+−V1​24 VR2​6 ΩAR4​30 ΩBR6​6 Ω

Combine resistors from the far end

Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.

R5 + R6 = 4 + 6 = 10 Ω
R4 ∥ 10 = 7.5 Ω
R3 + 7.5 = 19.5 Ω
R2 ∥ 19.5 = 4.588 Ω
Req = R1 + 4.588 = 5 + 4.588 = 9.588 Ω

Current from the source

The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.

IR1 = V1/Req = 24/9.588 = 2.503 A

Answer

IR1 = 2.503 A
3.Nodal analysis

Answer: I3 = −4 A

Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.

KCL at node A

Take the bottom wire as ground. Each branch carries (VA − Vk)/Rk away from A, where Vk is the voltage of its source (zero for a plain resistor). The currents leaving A add up to zero.

(VA − 24)/3 + (VA − 12)/12 + VA/3 = 0

Solve for VA

VA = (24/3 + 12/12 + 0/3) / (1/3 + 1/12 + 1/3) = 9/0.75 = 12 V

Branch current

The arrow points up through the branch, into node A.

I3 = (0 − VA)/R3 = (0 − 12)/3 = −4 A

Answer

I3 = −4 A

A negative result means the real current flows against the arrow.

4.Nodal analysis

Answer: Is = 0.6111 A

Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.

KCL at node A

VA is known, so this equation gives VB.

(VA − V1)/R1 + VA/R2 + (VA − VB)/R3 = 0
(2.5 − 15)/30 + 2.5/5 = (VB − 2.5)/8
0.08333 = (VB − 2.5)/8 → VB = 3.167 V

KCL at node B

Currents leaving B through the resistors equal the current pushed into B by sources.

Is = (VB − VA)/R3 + VB/R4 = (3.167 − 2.5)/8 + 3.167/6 = 0.6111 A

Answer

Is = 0.6111 A
5.Mesh analysis

Answer: IR2 = −0.8077 A

Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.

R1​ = 12 ΩR2​ = 10 Ω+−V1​6 VR3​4 ΩA+−V2​12 VI1​I2​

Assign mesh currents

Draw a clockwise current in each window: I1, I2. A resistor shared by two meshes carries the difference of their currents.

KVL around mesh 1

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R1·I1 + R3(I1 − I2) = V1
12·I1 + 4(I1 − I2) = 6
16·I1 − 4·I2 = 6

KVL around mesh 2

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R2·I2 + R3(I2 − I1) = −V2
10·I2 + 4(I2 − I1) = (−12)
−4·I1 + 14·I2 = −12

Solve

Δ = (16)(14) − (−4)(−4) = 208
I1 = Δ1/Δ = 36/208 = 0.1731 A
I2 = Δ2/Δ = −168/208 = −0.8077 A

Answer

IR2 = I2 = −0.8077 A

A negative mesh current flows anticlockwise.

6.Mesh analysis

Answer: VR5 = 2.987 V

Mesh analysis: give each window of a planar circuit its own loop current, write Kirchhoff’s voltage law around each loop (sum of drops = sum of rises), and solve. Branch currents are the mesh current, or the difference of two mesh currents on a shared branch.

R1​ = 8 ΩR2​ = 12 ΩR3​ = 25 Ω+−V1​15 VR4​4 ΩAR5​6 ΩB+−V2​12 VI1​I2​I3​

Assign mesh currents

Draw a clockwise current in each window: I1, I2, I3. A resistor shared by two meshes carries the difference of their currents.

KVL around mesh 1

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R1·I1 + R4(I1 − I2) = V1
8·I1 + 4(I1 − I2) = 15
12·I1 − 4·I2 = 15

KVL around mesh 2

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R2·I2 + R4(I2 − I1) + R5(I2 − I3) = 0
12·I2 + 4(I2 − I1) + 6(I2 − I3) = 0
−4·I1 + 22·I2 − 6·I3 = 0

KVL around mesh 3

Going clockwise, the voltage drops across resistors equal the source voltage rises (− to + in the direction of travel).

R3·I3 + R5(I3 − I2) = −V2
25·I3 + 6(I3 − I2) = (−12)
−6·I2 + 31·I3 = −12

Solve

Δ = det of the coefficient matrix = 7256
I1 = Δ1/Δ = 9402/7256 = 1.296 A
I2 = Δ2/Δ = 996/7256 = 0.1373 A
I3 = Δ3/Δ = −2616/7256 = −0.3605 A

Answer

IR5 = I2 − I3 = 0.4978 A
VR5 = IR5·R5 = 0.4978·6 = 2.987 V

A negative mesh current flows anticlockwise.

7.Superposition

Answer: I = 2.7 mA

Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.

Write the response as a sum of contributions

Each contribution is proportional to its own source, with a constant that depends only on the resistors.

I = k₁·Vs + k₂·Is
20·k₁ + 1·k₂ = 12.25
15·k₁ + 5·k₂ = 10.25

Solve for the constants

Δ = (20)(5) − (1)(15) = 85
k₁ = Δ1/Δ = 51/85 = 0.6
k₂ = Δ2/Δ = 21.25/85 = 0.25
k₁ = 0.6 mA/V, k₂ = 0.25

Predict the new current

I = 0.6·2 + 0.25·6 = 2.7 mA

Answer

I = 2.7 mA
8.Superposition

Answer: VR2 = −1.429 V

Superposition: in a linear circuit, any voltage or current is the sum of the responses to each independent source acting alone. To switch a source off, replace an ideal voltage source with a short circuit and an ideal current source with an open circuit. Resistors stay where they are.

R1​ = 8 ΩR2​ = 2 ΩR4​ = 30 Ω+−V1​30 VR3​2 ΩAOPENBSHORT

Case 1 · V1 acting alone

V₂ becomes a short and Iₛ an open circuit. Seen from A, R₃ is in parallel with the series pair R₂+R₄.

R3 ∥ (R2+R4) = 2 ∥ 32 = 1.882 Ω
VA = 30·1.882/(8+1.882) = 5.714 V
VB = VA·R4/(R2+R4) = 5.714·30/32 = 5.357 V
VR2′ = VA − VB = 5.714 − 5.357 = 0.3571 V
R1​ = 8 ΩR2​ = 2 ΩR4​ = 30 ΩSHORTR3​2 ΩAIs​0.5 ABSHORT

Case 2 · Is acting alone

Both voltage sources become shorts. Iₛ splits at B between R₄ (now to ground) and R₂ in series with R₁ ∥ R₃.

R1 ∥ R3 = 1.6 Ω, so the left path is R2+1.6 = 3.6 Ω
Req = R4 ∥ 3.6 = 3.214 Ω
VB = Is·Req = 0.5·3.214 = 1.607 V
VA = VB·1.6/3.6 = 0.7143 V
VR2″ = VA − VB = 0.7143 − 1.607 = −0.8929 V
R1​ = 8 ΩR2​ = 2 ΩR4​ = 30 ΩSHORTR3​2 ΩAOPENB+−V2​15 V

Case 3 · V2 acting alone

V₁ becomes a short and Iₛ an open circuit. R₁ ∥ R₃ hangs from A, in series with R₂ back to B.

R1 ∥ R3 = 8·2/(8+2) = 1.6 Ω
VB = V2·(R2+R1∥R3)/(R4+R2+R1∥R3) = 15·3.6/33.6 = 1.607 V
VA = VB·(R1∥R3)/(R2+R1∥R3) = 1.607·1.6/3.6 = 0.7143 V
VR2‴ = VA − VB = 0.7143 − 1.607 = −0.8929 V

Add the contributions

VR2 = VR2′ + VR2″ + VR2‴
VR2 = 0.3571 + (−0.8929) + (−0.8929) = −1.429 V

A negative result means the real polarity is opposite to the one marked.

9.Thévenin & Norton

Answer: IN = 0.5 A

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 5 ΩR3​ = 20 ΩSHORTR2​20 ΩAabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 5·20/(5+20) = 4 Ω
Rth = (R1 ∥ R2) + R3 = 4 + 20 = 24 Ω
R1​ = 5 ΩR3​ = 20 Ω+−V1​15 VR2​20 ΩAab+−Vth​

Find Vth, the open-circuit voltage

With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.

Vth = V1·R2/(R1+R2) = 15·20/(5+20) = 12 V
IN​0.5 ARth​24 Ωab

Norton equivalent

A Norton source is the same circuit seen as a current source in parallel with R_th. Its current is the short-circuit current at a–b.

IN = Vth/Rth = 12/24 = 0.5 A
10.Thévenin & Norton

Answer: Vth = −68.52 V

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 2 ΩR3​ = 30 ΩSHORTR2​25 ΩAOPENBabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 2·25/(2+25) = 1.852 Ω
Rth = (R1 ∥ R2) + R3 = 1.852 + 30 = 31.85 Ω
R1​ = 2 ΩR3​ = 30 Ω+−V1​12 VR2​25 ΩAIs​2.5 ABab+−Vth​

Find Vth, the open-circuit voltage

With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.

VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 11.11 + (−2.5)·1.852 = 6.481 V
Vth = VB = VA + Is·R3 = 6.481 + (−2.5)·30 = −68.52 V
11.RC & RL transients

Answer: i = 0.1105 A

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Time constant and final current

Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.

τ = L/R = 150 mH / 100 Ω = 1.5 ms
i(∞) = Vs/R = 15/100 = 0.15 A

Current at the given time

i(t) = i(∞)·(1 − e−t/τ) = 0.15·(1 − e−2/1.5) = 0.1105 A

Answer

i = 0.1105 A
12.RC & RL transients

Answer: t = 0.8429 ms

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Initial value, final value, time constant

Before t = 0 both resistors are in the loop; afterwards the closed switch bypasses R₂.

i(0) = 12/(20 + 20) = 0.3 A
i(∞) = 12/20 = 0.6 A
τ = L/R = 33/20 = 1.65 ms
i(t) = 0.6 + (0.3 − 0.6)·e−t/τ

Solve for the time

e−t/τ = (0.42 − 0.6)/(0.3 − 0.6) = 0.6
t = 1.65·ln(1.667) = 0.8429 ms

Answer

t = 0.8429 ms
13.AC impedance & phasors

Answer: φ = 79.08 °

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactances

ω = 2πf = 2π·500 = 3142 rad/s
XL = ωL = 3142·0.1 = 314.2 Ω
XC = 1/(ωC) = 1/(3142·100·10⁻⁶) = 3.183 Ω

Impedance

In series the impedances add as complex numbers: Z = R + j(XL − XC).

|Z| = √(R² + (XL − XC)²) = √(60² + (311)²) = 316.7 Ω

Phase angle

φ = arctan((XL − XC)/R) = arctan(311/60) = 79.08°

Answer

φ = 79.08°
14.AC impedance & phasors

Answer: Q = 21.32

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Resonant frequency

f0 = 1/(2π·√(0.01·0.22·10⁻⁶)) = 3393 Hz

Quality factor

Q compares the reactance at resonance with the resistance: Q = ω₀L/R.

Q = (1/R)·√(L/C) = (1/10)·√(0.01/(0.22·10⁻⁶)) = 21.32

Answer

Q = 21.32
15.AC power & power factor

Answer: Q = 19.37 kvar

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Angle

φ = arccos(0.9) = 25.84°, tan φ = 0.4843

Reactive power

Q = P·tan φ = 40·0.4843 = 19.37 kvar

Answer

Q = 19.37 kvar
16.AC power & power factor

Answer: cos φ = 0.9892

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Reactive power before and after

The real power P does not change; only the reactive power drawn from the supply does.

Q1 = 13·tan(arccos 0.65) = 15.2 kvar
QC = V²·2πf·C = 400²·2π·60·220·10⁻⁶ = 13270 var = 13.27 kvar
Q2 = 15.2 − 13.27 = 1.929 kvar

New apparent power

S2 = √(13² + 1.929²) = 13.14 kVA

New power factor

cos φ = P/S2 = 13/13.14 = 0.9892

Answer

cos φ = 0.9892
17.Three-phase power

Answer: P = 23.78 kW

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.

Apparent power

S = √3·VL·IL = √3·208·75 = 27.02 kVA

Real power

P = S·cos φ = 27.02·0.88 = 23.78 kW

Answer

P = 23.78 kW
18.Three-phase power

Answer: Cph = 294.6 µF

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.

Reactive power before and after

The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.

Q1 = 60·tan(acos 0.8) = 60·0.75 = 45 kvar
Q2 = 60·tan(acos 0.9) = 60·0.4843 = 29.06 kvar

Reactive power from the capacitors

QC = Q1 − Q2 = 15.94 kvar

Capacitance per phase

In a Y bank each capacitor is connected between a line and the star point.

V = 415/√3 = 239.6 V, ω = 2π·50 = 314.2 rad/s
Cph = (QC/3)/(ω·V²) = 5314/(314.2·239.6²) = 294.6 µF

Answer

Cph = 294.6 µF
19.Transformers

Answer: a = 4

Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.

Match the referred load

a²·8 = 128
a = √(128/8) = √16 = 4

Answer

a = 4
20.Transformers

Answer: Pcu,fl = 416.3 W

Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.

Output and input power

Pout = 50·0.8 = 40 kW
Pin = 40000/0.98 = 40816 W

Total and copper losses

Ploss = 40816 − 40000 = 816.3 W
Pcu,fl = 816.3 − 400 = 416.3 W

Answer

Pcu,fl = 416.3 W
21.Op-amp circuits

Answer: Rf = 60 kΩ

Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.

Gain of a non-inverting amplifier

V₋ = V₊ = Vin, and the current through R₁ also flows through Rf, so Vout = Vin·(1 + Rf/R₁).

Av = 1 + Rf/R1
Rf = (31 − 1)·2 = 60 kΩ

Answer

Rf = 60 kΩ
22.Op-amp circuits

Answer: Vout = −0.6797 V

Ideal op-amp rules: with negative feedback, the op-amp drives its output so that its two inputs sit at the same voltage (V₋ = V₊), and no current flows into either input. Writing KCL at the inverting input with these two facts gives the output.

Voltage at the + input

V₊ = V2·R4/(R3 + R4) = −0.6·100/(4.7 + 100) = −0.5731 V

Superpose the two inputs

With V₂ = 0, V₁ sees an inverting amplifier. With V₁ = 0, V₊ is amplified by the non-inverting gain 1 + R₂/R₁.

Vout = −(2/22)·0.6 + (1 + 2/22)·(−0.5731) = −0.05455 + (−0.6252) = −0.6797 V

Answer

Vout = −0.6797 V
23.Diodes & transistors

Answer: IC = 3.651 mA

BJT bias point: in the active region VBE = 0.7 V, IC = β·IB and IE = (β + 1)·IB. Find IB from the base loop with KVL, then IC, then VCE from the collector–emitter loop. A voltage divider at the base is replaced by its Thévenin equivalent VTH = VCC·R₂/(R₁ + R₂), RTH = R₁∥R₂; an emitter resistor appears (β + 1) times larger in the base loop.

Base current

IB = (VCC − VBE)/RB = (15 − 0.7)/470 kΩ = 30.43 µA

Collector current

IC = β·IB = 120·30.43 µA = 3.651 mA

Answer

IC = 3.651 mA

Check: VCE = 2.951 V is well above 0.2 V, so the transistor is indeed active.

24.Diodes & transistors

Answer: RB = 4.479 kΩ

BJT as a switch: to switch a load fully on, the transistor is driven into saturation, where VCE = VCE(sat) and the collector current is set by the load: IC(sat) = (VCC − VCE(sat))/RC. Saturation needs at least IB = IC(sat)/β. If the base current is smaller, the transistor stays active and IC = β·IB.

Collector current in saturation

IC(sat) = (5 − 0.2)/100 = 48 mA

Minimum base current

IB(min) = IC(sat)/β = 48/50 = 960 µA

Base resistor

RB = (5 − 0.7)/IB = 4.3 V/0.96 mA = 4.479 kΩ

Answer

RB = 4.479 kΩ

Any smaller base resistor also saturates the transistor; in practice you pick one a few times smaller.

25.Number systems

Answer: U = 250

Setting bits: each bit is worth a power of two (128, 64, …, 1). One hex digit is exactly four bits, and in 8-bit two's complement the leftmost bit is worth −128. Bitwise operations work on each bit position separately.

Invert and add one

6 = 0000 0110
inverted: 1111 1001
+1 → 1111 1010

Read it as unsigned

1111 1010₂ = 256 − 6 = 250

Answer

U = 250
26.Number systems

Answer: R = 21

Setting bits: each bit is worth a power of two (128, 64, …, 1). One hex digit is exactly four bits, and in 8-bit two's complement the leftmost bit is worth −128. Bitwise operations work on each bit position separately.

Bit by bit

Shifting right by 3 moves every bit 3 places to the right; bits that fall off the right end are lost and zeros come in on the left.

1010 1111 >> 3
= 0001 0101

Value of the result

0001 0101₂ = 21

Answer

R = 21
27.Digital logic: gates, K-maps & flip-flops

Answer: N = 4

Karnaugh maps: the cells are ordered in Gray code (00, 01, 11, 10), so neighbouring cells, including the ones across the edges, differ in exactly one variable. Group the 1s in rectangles of 1, 2, 4, 8 or 16 cells, as large as possible and as few as possible, until every 1 is covered. Each group is one product term: the variables that stay constant inside it. A group of 2ᵏ cells loses k variables. Don't-cares (X) may be used to make groups bigger but never have to be covered. Grouping the 0s instead gives the minimal POS form.

ABCD000111100001111000111312040517160120130150141809011110

Group the 0s

Every group is a rectangle of 2ᵏ cells; edge cells are neighbours of the cells on the opposite edge.

(B′ + C)
(A′ + D′)
(A + C + D)
(A′ + B′)

Minimal POS form

F = (B′ + C)(A′ + D′)(A + C + D)(A′ + B′)
N = 4

Answer

N = 4
28.Digital logic: gates, K-maps & flip-flops

Answer: N = 4

Flip-flops and counters: a flip-flop changes only at the active clock edge. D copies its input (Q⁺ = D); T toggles when T = 1; JK holds for 00, resets for 01, sets for 10 and toggles for 11. An n-bit binary counter has 2ⁿ states and counts modulo 2ⁿ; a mod-N counter goes 0, 1, …, N − 1 and back to 0, and needs the smallest n with 2ⁿ ≥ N flip-flops. Each stage of a ripple counter halves the frequency, so the last output of a mod-N counter runs at fclk/N. A Johnson counter of n flip-flops has 2n states, a ring counter n.

Q after every edge

A JK flip-flop: 00 holds, 01 resets (Q = 0), 10 sets (Q = 1), 11 toggles.

1: J = 1, K = 0 → Q = 1
2: J = 0, K = 0 → Q = 1
3: J = 1, K = 0 → Q = 1
4: J = 1, K = 0 → Q = 1
5: J = 0, K = 1 → Q = 0
6: J = 1, K = 0 → Q = 1
7: J = 1, K = 1 → Q = 0

Count the changes

0 → 1 → 1 → 1 → 1 → 0 → 1 → 0
N = 4

Answer

N = 4
29.Laplace transforms

Answer: A = 3

Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).

Factor the denominator

s² + 15s + 56 = (s + 7)(s + 8)
F(s) = A/(s + 7) + B/(s + 8)

Cover-up rule

Multiply by (s + 7) and set s = −7: the B-term vanishes.

A = (4s + 31)/(s + 8) |s = −7 = 3/1 = 3

Answer

A = 3
(B = 1, so f(t) = 3·e−7t + e−8t)
30.Laplace transforms

Answer: y(0.1) = 1.149

Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).

Transform the equation

(s² + 9s + 20)·Y(s) = 1s + 9 + 60/s
Y(s) = (s² + 9s + 60)/(s(s + 4)(s + 5))

Partial fractions

A = 60/(4·5) = 3
B = 40/((−4)·1) = −10
C = 40/((−5)·(−1)) = 8

Result

y(t) = 3 − 10·e−4t + 8·e−5t
y(0.1) = 1.149

Answer

y(0.1) = 1.149

Check: y(0) = A + B + C = 1.

31.Block diagrams

Answer: T(0) = 0.5263

Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).

Inner loop

Gᵢ = G/(1 + G·H₁) = 1/(s + 5 + 1·4) = 1/(s + 9)

Outer loop

T(s) = K·Gᵢ/(1 + K·Gᵢ) = 10/(s + 9 + 10) = 10/(s + 19)

Result

T(0) = 10/19 = 0.5263

Answer

T(0) = 0.5263
32.Block diagrams

Answer: K = 99

Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).

Disturbance response

css = D·G(0)/(1 + K·G(0)) = 5·8/(8 + 8K)

Solve for K

8 + 8K = 5·8/0.05 = 800
K = (800 − 8)/8 = 99

Answer

K = 99
33.Step response

Answer: %OS = 15.75 %

Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).

Compare with the standard form

The denominator must match s² + 2ζωₙs + ωₙ².

ωₙ² = 35 → ωₙ = 5.916 rad/s
2ζωₙ = 6 → ζ = 6/(2·5.916) = 0.5071

Result

%OS = 100·e−ζπ/√(1−ζ²) = 100·e−1.848 = 15.75 %

Answer

%OS = 15.75 %
34.Step response

Answer: ωn = 4.587 rad/s

Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).

Damping ratio

ζ = −ln(0.15)/√(π² + ln²(0.15)) = 1.897/√(9.87 + 3.599) = 0.5169

Natural frequency

ωd = π/tp = π/0.8 = 3.927 rad/s
ωₙ = ωd/√(1 − ζ²) = 3.927/0.856 = 4.587 rad/s

Answer

ωn = 4.587 rad/s
35.Bode plots & margins

Answer: |G(jω)| = 13.26 dB

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Multiply the magnitudes

|G(j10)| = 756/(√(10² + 7²)·√(10² + 9²)) = 756/(12.21·13.45) = 4.604

Result

20·log₁₀(4.604) = 13.26 dB

Answer

|G(jω)| = 13.26 dB
36.Bode plots & margins

Answer: GM = 4.973 dB

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Phase crossover

(ω/6)·(ω/7) = 1 → ω180 = √(6·7) = 6.481 rad/s

Magnitude at phase crossover

|L(jω180)| = K/(ω·√(ω² + 36)·√(ω² + 49)) = K/(6·7·(6 + 7)) = K/546

Gain margin

GM = 20·log₁₀(546/308) = 4.973 dB

Answer

GM = 4.973 dB
37.Stability: Routh–Hurwitz & root locus

Answer: Kmax = 616

Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.

Characteristic polynomial

s³ + 13s² + 52s + 60 + K = 0

Routh array

s³: 1, 52
s²: 13, 60 + K
s¹: (13·52 − 60 − K)/13
s⁰: 60 + K

Condition

The s¹ entry must stay positive.

K < 13·52 − 60 = 616

Answer

Kmax = 616

At the limit the loop oscillates at ω = √52 = 7.211 rad/s.

38.Stability: Routh–Hurwitz & root locus

Answer: K = 39.06

Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.

Compare with the standard form

s² + 5s + K = s² + 2ζωₙs + ωₙ²
2·0.4·ωₙ = 5 → ωₙ = 6.25 rad/s

Gain

K = ωₙ² = 6.25² = 39.06

Answer

K = 39.06

The closed-loop poles sit where the ζ line crosses the vertical branch at s = −2.5.

39.Steady-state error & PID control

Answer: ess = 10

Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.

Acceleration constant

Ka = 5·2/10 = 1

Parabola error

ess = 10/1 = 10

Answer

ess = 10
40.Steady-state error & PID control

Answer: ts = 1.333 s

P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).

Characteristic polynomial

s(s + 6) + 20·10 = s² + 6s + 200

ωₙ and ζ

ωₙ = √200 = 14.14 rad/s
ζ = 6/(2·14.14) = 0.2121

Settling time

ζωₙ = 6/2 = 3
ts ≈ 4/3 = 1.333 s

Answer

ts = 1.333 s