Hydrostatic force
- Pressure at depth
- p = ρgh
- Force on a vertical wall
- F = ρg·hc·A
- Centre of pressure
- yp = yc + Ic/(ycA)
- Rectangle
- Ic = bH³/12
Formula sheets, the key method steps for every topic and 8 practice problems, with full solutions at the back.
A vertical rectangular gate 3 m wide sits in the wall of a tank of water, with its top edge 1.5 m below the surface. Find the resultant hydrostatic force F on the gate.
A vertical rectangular gate 1 m wide sits in the wall of a tank of glycerin, with its top edge 3 m below the surface. Find the depth ycp of the centre of pressure below the surface.
A pitot-static tube in a water pipe reads a difference of 20 kPa between the stagnation pressure and the static pressure. Find the water velocity v at the tip.
Water flows up through a pipe that narrows from 150 mm to 50 mm while rising 5 m. At section 1 the pressure is 340 kPa and the velocity is 0.75 m/s. Ignoring losses, find the pressure p2 at section 2.
Water flows at a mean velocity of 1 m/s through a pipe 200 m long with an inside diameter of 75 mm. Use the Darcy friction factor f = 0.018 and g = 9.81 m/s². Find the friction head loss hf.
A pipe 200 m long with an inside diameter of 200 mm (Darcy friction factor f = 0.02) runs from an open reservoir and discharges as a free jet into the air. The minor losses are a square-edged entrance (K = 0.5), 4 bends (K = 0.3 each) and a valve (K = 5). Use g = 9.81 m/s². How far H must the reservoir surface be above the pipe outlet for a flow rate of 75 L/s?
In a test, a pump delivers 60 L/s of water (ρ = 1000 kg/m³) against a head of 78 m while its shaft takes 63.8 kW. Use g = 9.81 m/s². Find the pump efficiency η in percent.
A pump moves 75 L/s of water (ρ = 1000 kg/m³) from an open lower reservoir to an upper tank whose water surface is 10 m higher. The pipe is 300 m long with an inside diameter of 200 mm and a Darcy friction factor f = 0.02; the minor-loss coefficients add up to ΣK = 8 (entrance and exit included). Use g = 9.81 m/s². The pump efficiency is 78%. Find the shaft power Pshaft in kW.
Answer: F = 147.2 kN
Hydrostatic force on a plane surface: F = ρ·g·yc·A. It acts at the centre of pressure, ycp = yc + Ic/(ycA), which always lies below the centroid.
Answer: ycp = 4.667 m
Hydrostatic force on a plane surface: F = ρ·g·yc·A. It acts at the centre of pressure, ycp = yc + Ic/(ycA), which always lies below the centroid.
Pressure grows with depth, so the resultant acts below the centroid.
Answer: v = 6.325 m/s
Continuity and Bernoulli: for an incompressible fluid the flow rate is the same at every section, Q = A₁v₁ = A₂v₂. Along a streamline without losses, p + ½ρv² + ρgz is constant, so where the fluid is faster or higher its pressure is lower.
The flow comes to rest at the tip, so its kinetic energy shows up as extra pressure.
Answer: p2 = 268.4 kPa
Continuity and Bernoulli: for an incompressible fluid the flow rate is the same at every section, Q = A₁v₁ = A₂v₂. Along a streamline without losses, p + ½ρv² + ρgz is constant, so where the fluid is faster or higher its pressure is lower.
Work in Pa, then divide by 1000 to get kPa.
Answer: hf = 2.446 m
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
Answer: H = 8.046 m
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
The outlet jet still carries its velocity head; it is not a loss but it has to be supplied.
Answer: η = 71.96 %
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Answer: Pshaft = 19.84 kW
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
ExamProblems · examproblems.com/courses/fluid-mechanics