Heat Transfer: cram pack

Formula sheets, the key method steps for every topic and 4 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

Heat conduction

Fourier’s law
Q̇ = kAΔT/L
Conduction resistance
R = L/(kA)
Convection resistance
R = 1/(hA)
Resistances in series
Q̇ = ΔTtotal/ΣR
U-value
U = 1/(ΣR·A)

Heat exchangers (LMTD)

Heat duty
Q = U·A·ΔTlm
Log mean temperature difference
ΔTlm = (ΔT1 − ΔT2)/ln(ΔT1/ΔT2)
Stream balance
Q = ṁcp(Tin − Tout)

2Practice problems

1.Heat conductionMedium
Brick, k = 0.72100 mmGypsum board, k = 0.1750 mm15 °C7 °CQ̇ = ?

A wall is made of 100 mm of brick and 50 mm of gypsum board, with an area of 4 m². The outer faces are at 15 °C and 7 °C. Find the heat flow Q̇ through the wall.

L1 = 100 mm, k1 = 0.72 W/(m·K)L2 = 50 mm, k2 = 0.17 W/(m·K)A = 4 m²T1 = 15 °CT3 = 7 °C
Q̇ = W
2.Heat conductionHard
Gypsum board, k = 0.17150 mmMineral wool, k = 0.04150 mmroom 20 °Coutside -3 °CTs​ = ?Q̇

A wall of 150 mm gypsum board and 150 mm mineral wool separates a room at 20 °C from outside air at -3 °C. The convection coefficients are 8 W/(m²·K) inside and 30 W/(m²·K) outside, and the wall area is 4 m². Find the temperature Ts of the inside surface of the wall.

L1 = 150 mm, k1 = 0.17 W/(m·K)L2 = 150 mm, k2 = 0.04 W/(m·K)A = 4 m²hi = 8 W/(m²·K)ho = 30 W/(m²·K)Troom = 20 °CTout = -3 °C
Ts = °C
3.Heat exchangers (LMTD)Medium
lengthT80 °C60 °C55 °C30 °CΔT₁ΔT₂counter-flow

A counter-flow heat exchanger transfers 250 kW. Its heat transfer area is 2.5 m². The hot fluid cools from 80 to 60 °C and the cold fluid heats from 30 to 55 °C. Find the overall heat transfer coefficient U.

Q̇ = 250 kWA = 2.5 m²Th: 80 → 60 °CTc: 30 → 55 °C
U = W/(m²·K)
4.Heat exchangers (LMTD)Hard
lengthT125 °C75 °C14.19 °C10 °CΔT₁ΔT₂counter-flow

Hot oil (0.5 kg/s, cp = 2.1 kJ/(kg·K)) cools from 125 to 75 °C in a counter-flow exchanger. It heats 3 kg/s of water (cp = 4.18 kJ/(kg·K)) that enters at 10 °C. With U = 200 W/(m²·K), find the heat transfer area A needed.

ṁh = 0.5 kg/scp,h = 2.1 kJ/(kg·K)Th: 125 → 75 °Cṁc = 3 kg/scp,c = 4.18 kJ/(kg·K)Tc,in = 10 °CU = 200 W/(m²·K)
A = m²

3Solutions

1.Heat conduction

Answer: Q̇ = 73.9 W

Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.

Layer resistances

R1 = L1/(k1A) = (100/1000)/(0.72·4) = 0.03472 K/W
R2 = L2/(k2A) = (50/1000)/(0.17·4) = 0.07353 K/W

Heat flow

Q̇ = (T1 − T3)/(R1 + R2) = 8/0.1083 = 73.9 W

Answer

Q̇ = 73.9 W
2.Heat conduction

Answer: Ts = 19.4 °C

Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.

Resistances in series

Ri = 1/(hiA) = 1/(8·4) = 0.03125 K/W
R1 = L1/(k1A) = (150/1000)/(0.17·4) = 0.2206 K/W
R2 = L2/(k2A) = (150/1000)/(0.04·4) = 0.9375 K/W
Ro = 1/(hoA) = 1/(30·4) = 0.008333 K/W
ΣR = 1.198 K/W

Heat loss

Q̇ = (20 − (-3))/1.198 = 19.2 W
Ts = Troom − Q̇·Ri = 20 − 19.2·0.03125 = 19.4 °C

Answer

Ts = 19.4 °C
3.Heat exchangers (LMTD)

Answer: U = 3646 W/(m²·K)

LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.

End temperature differences

In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.

ΔT₁ = Th,in − Tc,out = 80 − 55 = 25 K
ΔT₂ = Th,out − Tc,in = 60 − 30 = 30 K

Log-mean temperature difference

ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) = (25 − 30)/ln(25/30) = 27.42 K

Overall coefficient

U = Q̇/(A·ΔTlm) = 250000/(2.5·27.42) = 3646 W/(m²·K)

Answer

U = 3646 W/(m²·K)
4.Heat exchangers (LMTD)

Answer: A = 3.057 m²

LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.

Heat duty and water outlet temperature

Q̇ = ṁhcp,h(Th,in − Th,out) = 0.5·2.1·50 = 52.5 kW
Tc,out = 10 + 52.5/(3·4.18) = 14.19 °C

End temperature differences

In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.

ΔT₁ = Th,in − Tc,out = 125 − 14.19 = 110.8 K
ΔT₂ = Th,out − Tc,in = 75 − 10 = 65 K

Log-mean temperature difference

ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) = (110.8 − 65)/ln(110.8/65) = 85.88 K

Area

A = Q̇/(U·ΔTlm) = 52500/(200·85.88) = 3.057 m²

Answer

A = 3.057 m²

ExamProblems · examproblems.com/courses/heat-transfer