Heat Transfer: cram pack

Formula sheets, the key method steps for every topic and 4 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

Heat conduction

Fourier’s law
Q̇ = kAΔT/L
Conduction resistance
R = L/(kA)
Convection resistance
R = 1/(hA)
Resistances in series
Q̇ = ΔTtotal/ΣR
U-value
U = 1/(ΣR·A)

Heat exchangers (LMTD)

Heat duty
Q = U·A·ΔTlm
Log mean temperature difference
ΔTlm = (ΔT1 − ΔT2)/ln(ΔT1/ΔT2)
Stream balance
Q = ṁcp(Tin − Tout)

2Practice problems

1.Heat conductionMedium
Wood, k = 0.17100 mmExpanded polystyrene, k = 0.035100 mm15 °C-7 °CTi​ = ?Q̇

A wall is made of 100 mm of wood and 100 mm of expanded polystyrene, with an area of 4 m². The outer faces are at 15 °C and -7 °C. Find the temperature Ti at the interface between the two layers.

L1 = 100 mm, k1 = 0.17 W/(m·K)L2 = 100 mm, k2 = 0.035 W/(m·K)A = 4 m²T1 = 15 °CT3 = -7 °C
Ti = °C
2.Heat conductionHard
Wood, k = 0.17150 mmExpanded polystyrene, k = 0.03525 mmroom 20 °Coutside -15 °CTs​ = ?Q̇

A wall of 150 mm wood and 25 mm expanded polystyrene separates a room at 20 °C from outside air at -15 °C. The convection coefficients are 7.7 W/(m²·K) inside and 30 W/(m²·K) outside, and the wall area is 15 m². Find the temperature Ts of the inside surface of the wall.

L1 = 150 mm, k1 = 0.17 W/(m·K)L2 = 25 mm, k2 = 0.035 W/(m·K)A = 15 m²hi = 7.7 W/(m²·K)ho = 30 W/(m²·K)Troom = 20 °CTout = -15 °C
Ts = °C
3.Heat exchangers (LMTD)Medium
lengthT120 °C105 °C45 °C25 °CΔT₁ΔT₂counter-flow

A counter-flow heat exchanger transfers 460 kW. The hot fluid cools from 120 to 105 °C and the cold fluid heats from 25 to 45 °C. The overall heat transfer coefficient is 1500 W/(m²·K). Find the heat transfer area A needed.

Q̇ = 460 kWU = 1500 W/(m²·K)Th: 120 → 105 °CTc: 25 → 45 °C
A = m²
4.Heat exchangers (LMTD)Hard
lengthT105 °C??30 °CΔT₁ΔT₂counter-flow

In a counter-flow heat exchanger both streams have the same heat capacity rate, ṁ·cp = 1 kW/K. The hot stream enters at 105 °C and the cold stream at 30 °C. The exchanger has A = 4 m² and U = 800 W/(m²·K). Find the hot outlet temperature Th,out.

Ch = Cc = 1 kW/KTh,in = 105 °CTc,in = 30 °CA = 4 m²U = 800 W/(m²·K)
Th,out = °C

3Solutions

1.Heat conduction

Answer: Ti = 11.24 °C

Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.

Layer resistances

R1 = L1/(k1A) = (100/1000)/(0.17·4) = 0.1471 K/W
R2 = L2/(k2A) = (100/1000)/(0.035·4) = 0.7143 K/W

Heat flow

Q̇ = (T1 − T3)/(R1 + R2) = 22/0.8613 = 25.54 W

Interface temperature

The temperature drops across the first layer by Q̇·R₁.

Ti = T1 − Q̇·R1 = 15 − 25.54·0.1471 = 11.24 °C

Answer

Ti = 11.24 °C
2.Heat conduction

Answer: Ts = 17.42 °C

Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.

Resistances in series

Ri = 1/(hiA) = 1/(7.7·15) = 0.008658 K/W
R1 = L1/(k1A) = (150/1000)/(0.17·15) = 0.05882 K/W
R2 = L2/(k2A) = (25/1000)/(0.035·15) = 0.04762 K/W
Ro = 1/(hoA) = 1/(30·15) = 0.002222 K/W
ΣR = 0.1173 K/W

Heat loss

Q̇ = (20 − (-15))/0.1173 = 298.3 W
Ts = Troom − Q̇·Ri = 20 − 298.3·0.008658 = 17.42 °C

Answer

Ts = 17.42 °C
3.Heat exchangers (LMTD)

Answer: A = 3.958 m²

LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.

End temperature differences

In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.

ΔT₁ = Th,in − Tc,out = 120 − 45 = 75 K
ΔT₂ = Th,out − Tc,in = 105 − 25 = 80 K

Log-mean temperature difference

ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) = (75 − 80)/ln(75/80) = 77.47 K

Area

A = Q̇/(U·ΔTlm) = 460000/(1500·77.47) = 3.958 m²

Answer

A = 3.958 m²
4.Heat exchangers (LMTD)

Answer: Th,out = 47.86 °C

LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.

Constant temperature difference

The cold outlet sits opposite the hot inlet: Tc,out = Tc,in + (Th,in − Th,out), so ΔT₁ = Th,in − Tc,out = Th,out − Tc,in = ΔT₂.

ΔTlm = Th,out − Tc,in

Energy balance equals rate equation

1·(105 − Th,out) = 3.2·(Th,out − 30)
Th,out = (1·105 + 3.2·30)/(1 + 3.2) = 47.86 °C

Answer

Th,out = 47.86 °C

Heat transferred: Q̇ = 57.14 kW; the cold stream leaves at 87.14 °C.