Heat Transfer: cram pack

Formula sheets, the key method steps for every topic and 4 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

Heat conduction

Fourier’s law
Q̇ = kAΔT/L
Conduction resistance
R = L/(kA)
Convection resistance
R = 1/(hA)
Resistances in series
Q̇ = ΔTtotal/ΣR
U-value
U = 1/(ΣR·A)

Heat exchangers (LMTD)

Heat duty
Q = U·A·ΔTlm
Log mean temperature difference
ΔTlm = (ΔT1 − ΔT2)/ln(ΔT1/ΔT2)
Stream balance
Q = ṁcp(Tin − Tout)

2Practice problems

1.Heat conductionMedium
Gypsum board, k = 0.17200 mmBrick, k = 0.7275 mm15 °C-15 °CQ̇ = ?

A wall is made of 200 mm of gypsum board and 75 mm of brick, with an area of 6 m². The outer faces are at 15 °C and -15 °C. Find the heat flow Q̇ through the wall.

L1 = 200 mm, k1 = 0.17 W/(m·K)L2 = 75 mm, k2 = 0.72 W/(m·K)A = 6 m²T1 = 15 °CT3 = -15 °C
Q̇ = W
2.Heat conductionHard
Concrete, k = 1.450 mmExpanded polystyrene, k = 0.03550 mmroom 22 °Coutside -14 °CTs​ = ?Q̇

A wall of 50 mm concrete and 50 mm expanded polystyrene separates a room at 22 °C from outside air at -14 °C. The convection coefficients are 6 W/(m²·K) inside and 30 W/(m²·K) outside, and the wall area is 10 m². Find the temperature Ts of the inside surface of the wall.

L1 = 50 mm, k1 = 1.4 W/(m·K)L2 = 50 mm, k2 = 0.035 W/(m·K)A = 10 m²hi = 6 W/(m²·K)ho = 30 W/(m²·K)Troom = 22 °CTout = -14 °C
Ts = °C
3.Heat exchangers (LMTD)Medium
lengthT95 °C80 °C55 °C25 °CΔT₁ΔT₂counter-flow

A counter-flow heat exchanger transfers 320 kW. The hot fluid cools from 95 to 80 °C and the cold fluid heats from 25 to 55 °C. The overall heat transfer coefficient is 200 W/(m²·K). Find the heat transfer area A needed.

Q̇ = 320 kWU = 200 W/(m²·K)Th: 95 → 80 °CTc: 25 → 55 °C
A = m²
4.Heat exchangers (LMTD)Hard
lengthT90 °C60 °C?25 °CΔT₁ΔT₂counter-flow

In a counter-flow double-pipe heat exchanger, hot oil (0.3 kg/s, cp = 2.5 kJ/(kg·K)) flows in the inner tube and cools from 90 to 60 °C. Water (1 kg/s, cp = 4.18 kJ/(kg·K)) in the annulus enters at 25 °C. The inner tube has a diameter of 50 mm, and U = 200 W/(m²·K) is based on this diameter. Find the tube length L needed.

ṁh = 0.3 kg/scp,h = 2.5 kJ/(kg·K)Th: 90 → 60 °Cṁc = 1 kg/sTc,in = 25 °CD = 50 mmU = 200 W/(m²·K)
L = m

3Solutions

1.Heat conduction

Answer: Q̇ = 140.6 W

Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.

Layer resistances

R1 = L1/(k1A) = (200/1000)/(0.17·6) = 0.1961 K/W
R2 = L2/(k2A) = (75/1000)/(0.72·6) = 0.01736 K/W

Heat flow

Q̇ = (T1 − T3)/(R1 + R2) = 30/0.2134 = 140.6 W

Answer

Q̇ = 140.6 W
2.Heat conduction

Answer: Ts = 18.39 °C

Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.

Resistances in series

Ri = 1/(hiA) = 1/(6·10) = 0.01667 K/W
R1 = L1/(k1A) = (50/1000)/(1.4·10) = 0.003571 K/W
R2 = L2/(k2A) = (50/1000)/(0.035·10) = 0.1429 K/W
Ro = 1/(hoA) = 1/(30·10) = 0.003333 K/W
ΣR = 0.1664 K/W

Heat loss

Q̇ = (22 − (-14))/0.1664 = 216.3 W
Ts = Troom − Q̇·Ri = 22 − 216.3·0.01667 = 18.39 °C

Answer

Ts = 18.39 °C
3.Heat exchangers (LMTD)

Answer: A = 33.97 m²

LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.

End temperature differences

In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.

ΔT₁ = Th,in − Tc,out = 95 − 55 = 40 K
ΔT₂ = Th,out − Tc,in = 80 − 25 = 55 K

Log-mean temperature difference

ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) = (40 − 55)/ln(40/55) = 47.1 K

Area

A = Q̇/(U·ΔTlm) = 320000/(200·47.1) = 33.97 m²

Answer

A = 33.97 m²
4.Heat exchangers (LMTD)

Answer: L = 15.5 m

LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.

Heat duty and water outlet temperature

Q̇ = 0.3·2.5·(90 − 60) = 22.5 kW
Tc,out = 25 + 22.5/(1·4.18) = 30.38 °C

End temperature differences

In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.

ΔT₁ = Th,in − Tc,out = 90 − 30.38 = 59.62 K
ΔT₂ = Th,out − Tc,in = 60 − 25 = 35 K

Log-mean temperature difference

ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) = (59.62 − 35)/ln(59.62/35) = 46.22 K

Area and length

A = 22500/(200·46.22) = 2.434 m²
L = A/(πD) = 2.434/(π·0.05) = 15.5 m

Answer

L = 15.5 m