1Formulas and methods

Heat conduction

Fourier’s law
Q̇ = kAΔT/L
Conduction resistance
R = L/(kA)
Convection resistance
R = 1/(hA)
Resistances in series
Q̇ = ΔTtotal/ΣR
U-value
U = 1/(ΣR·A)

Heat exchangers (LMTD)

Heat duty
Q = U·A·ΔTlm
Log mean temperature difference
ΔTlm = (ΔT1 − ΔT2)/ln(ΔT1/ΔT2)
Stream balance
Q = ṁcp(Tin − Tout)

2Practice problems

1.Heat conductionMedium
Concrete, k = 1.4150 mmBrick, k = 0.72100 mm19 °C6 °CTi​ = ?Q̇

A wall is made of 150 mm of concrete and 100 mm of brick, with an area of 10 m². The outer faces are at 19 °C and 6 °C. Find the temperature Ti at the interface between the two layers.

L1 = 150 mm, k1 = 1.4 W/(m·K)L2 = 100 mm, k2 = 0.72 W/(m·K)A = 10 m²T1 = 19 °CT3 = 6 °C
Ti = °C
2.Heat conductionHard
Expanded polystyrene, k = 0.035200 mmGypsum board, k = 0.17100 mmroom 22 °Coutside -14 °CTs​ = ?Q̇

A wall of 200 mm expanded polystyrene and 100 mm gypsum board separates a room at 22 °C from outside air at -14 °C. The convection coefficients are 8 W/(m²·K) inside and 30 W/(m²·K) outside, and the wall area is 15 m². Find the temperature Ts of the inside surface of the wall.

L1 = 200 mm, k1 = 0.035 W/(m·K)L2 = 100 mm, k2 = 0.17 W/(m·K)A = 15 m²hi = 8 W/(m²·K)ho = 30 W/(m²·K)Troom = 22 °CTout = -14 °C
Ts = °C
3.Heat exchangers (LMTD)Medium
lengthT100 °C65 °C10 °C50 °CΔT₁ΔT₂parallel flow

A parallel-flow heat exchanger transfers 410 kW. The hot fluid cools from 100 to 65 °C and the cold fluid heats from 10 to 50 °C. The overall heat transfer coefficient is 500 W/(m²·K). Find the heat transfer area A needed.

Q̇ = 410 kWU = 500 W/(m²·K)Th: 100 → 65 °CTc: 10 → 50 °C
A = m²
4.Heat exchangers (LMTD)Hard
lengthT180 °C55 °C40.47 °C30 °CΔT₁ΔT₂counter-flow

Hot oil (0.5 kg/s, cp = 2.1 kJ/(kg·K)) cools from 180 to 55 °C in a counter-flow exchanger. It heats 3 kg/s of water (cp = 4.18 kJ/(kg·K)) that enters at 30 °C. With U = 500 W/(m²·K), find the heat transfer area A needed.

ṁh = 0.5 kg/scp,h = 2.1 kJ/(kg·K)Th: 180 → 55 °Cṁc = 3 kg/scp,c = 4.18 kJ/(kg·K)Tc,in = 30 °CU = 500 W/(m²·K)
A = m²

3Solutions

1.Heat conduction

Answer: Ti = 13.34 °C

Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.

Layer resistances

R1 = L1/(k1A) = (150/1000)/(1.4·10) = 0.01071 K/W
R2 = L2/(k2A) = (100/1000)/(0.72·10) = 0.01389 K/W

Heat flow

Q̇ = (T1 − T3)/(R1 + R2) = 13/0.0246 = 528.4 W

Interface temperature

The temperature drops across the first layer by Q̇·R₁.

Ti = T1 − Q̇·R1 = 19 − 528.4·0.01071 = 13.34 °C

Answer

Ti = 13.34 °C
2.Heat conduction

Answer: Ts = 21.3 °C

Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.

Resistances in series

Ri = 1/(hiA) = 1/(8·15) = 0.008333 K/W
R1 = L1/(k1A) = (200/1000)/(0.035·15) = 0.381 K/W
R2 = L2/(k2A) = (100/1000)/(0.17·15) = 0.03922 K/W
Ro = 1/(hoA) = 1/(30·15) = 0.002222 K/W
ΣR = 0.4307 K/W

Heat loss

Q̇ = (22 − (-14))/0.4307 = 83.58 W
Ts = Troom − Q̇·Ri = 22 − 83.58·0.008333 = 21.3 °C

Answer

Ts = 21.3 °C
3.Heat exchangers (LMTD)

Answer: A = 19.59 m²

LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.

End temperature differences

In parallel flow both inlets are at the same end, and both outlets at the other.

ΔT₁ = Th,in − Tc,in = 100 − 10 = 90 K
ΔT₂ = Th,out − Tc,out = 65 − 50 = 15 K

Log-mean temperature difference

ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) = (90 − 15)/ln(90/15) = 41.86 K

Area

A = Q̇/(U·ΔTlm) = 410000/(500·41.86) = 19.59 m²

Answer

A = 19.59 m²
4.Heat exchangers (LMTD)

Answer: A = 3.941 m²

LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.

Heat duty and water outlet temperature

Q̇ = ṁhcp,h(Th,in − Th,out) = 0.5·2.1·125 = 131.3 kW
Tc,out = 30 + 131.3/(3·4.18) = 40.47 °C

End temperature differences

In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.

ΔT₁ = Th,in − Tc,out = 180 − 40.47 = 139.5 K
ΔT₂ = Th,out − Tc,in = 55 − 30 = 25 K

Log-mean temperature difference

ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) = (139.5 − 25)/ln(139.5/25) = 66.61 K

Area

A = Q̇/(U·ΔTlm) = 131250/(500·66.61) = 3.941 m²

Answer

A = 3.941 m²