Heat Transfer: cram pack

Formula sheets, the key method steps for every topic and 4 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

Heat conduction

Fourier’s law
Q̇ = kAΔT/L
Conduction resistance
R = L/(kA)
Convection resistance
R = 1/(hA)
Resistances in series
Q̇ = ΔTtotal/ΣR
U-value
U = 1/(ΣR·A)

Heat exchangers (LMTD)

Heat duty
Q = U·A·ΔTlm
Log mean temperature difference
ΔTlm = (ΔT1 − ΔT2)/ln(ΔT1/ΔT2)
Stream balance
Q = ṁcp(Tin − Tout)

2Practice problems

1.Heat conductionMedium
Mineral wool, k = 0.04200 mmExpanded polystyrene, k = 0.03575 mm25 °C-2 °CTi​ = ?Q̇

A wall is made of 200 mm of mineral wool and 75 mm of expanded polystyrene, with an area of 8 m². The outer faces are at 25 °C and -2 °C. Find the temperature Ti at the interface between the two layers.

L1 = 200 mm, k1 = 0.04 W/(m·K)L2 = 75 mm, k2 = 0.035 W/(m·K)A = 8 m²T1 = 25 °CT3 = -2 °C
Ti = °C
2.Heat conductionHard
Glass, k = 0.96100 mmExpanded polystyrene, k = 0.035100 mmroom 20 °Coutside -9 °CTs​ = ?Q̇

A wall of 100 mm glass and 100 mm expanded polystyrene separates a room at 20 °C from outside air at -9 °C. The convection coefficients are 8 W/(m²·K) inside and 20 W/(m²·K) outside, and the wall area is 12 m². Find the temperature Ts of the inside surface of the wall.

L1 = 100 mm, k1 = 0.96 W/(m·K)L2 = 100 mm, k2 = 0.035 W/(m·K)A = 12 m²hi = 8 W/(m²·K)ho = 20 W/(m²·K)Troom = 20 °CTout = -9 °C
Ts = °C
3.Heat exchangers (LMTD)Medium
lengthT105 °C20 °C65 °CΔT₁ΔT₂condensing steam

In a condenser, steam condenses at a constant 105 °C on the outside of the tubes. Cooling water (4 kg/s, cp = 4.18 kJ/(kg·K)) flows through the tubes and heats from 20 to 65 °C. The overall heat transfer coefficient is 3000 W/(m²·K). Find the heat transfer area A needed.

Ts = 105 °Cṁ = 4 kg/scp = 4.18 kJ/(kg·K)Tc: 20 → 65 °CU = 3000 W/(m²·K)
A = m²
4.Heat exchangers (LMTD)Hard
lengthT175 °C??10 °CΔT₁ΔT₂counter-flow

In a counter-flow heat exchanger both streams have the same heat capacity rate, ṁ·cp = 2 kW/K. The hot stream enters at 175 °C and the cold stream at 10 °C. The exchanger has A = 3 m² and U = 300 W/(m²·K). Find the hot outlet temperature Th,out.

Ch = Cc = 2 kW/KTh,in = 175 °CTc,in = 10 °CA = 3 m²U = 300 W/(m²·K)
Th,out = °C

3Solutions

1.Heat conduction

Answer: Ti = 6.1 °C

Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.

Layer resistances

R1 = L1/(k1A) = (200/1000)/(0.04·8) = 0.625 K/W
R2 = L2/(k2A) = (75/1000)/(0.035·8) = 0.2679 K/W

Heat flow

Q̇ = (T1 − T3)/(R1 + R2) = 27/0.8929 = 30.24 W

Interface temperature

The temperature drops across the first layer by Q̇·R₁.

Ti = T1 − Q̇·R1 = 25 − 30.24·0.625 = 6.1 °C

Answer

Ti = 6.1 °C
2.Heat conduction

Answer: Ts = 18.84 °C

Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.

Resistances in series

Ri = 1/(hiA) = 1/(8·12) = 0.01042 K/W
R1 = L1/(k1A) = (100/1000)/(0.96·12) = 0.008681 K/W
R2 = L2/(k2A) = (100/1000)/(0.035·12) = 0.2381 K/W
Ro = 1/(hoA) = 1/(20·12) = 0.004167 K/W
ΣR = 0.2614 K/W

Heat loss

Q̇ = (20 − (-9))/0.2614 = 111 W
Ts = Troom − Q̇·Ri = 20 − 111·0.01042 = 18.84 °C

Answer

Ts = 18.84 °C
3.Heat exchangers (LMTD)

Answer: A = 4.201 m²

LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.

Heat duty from the water side

Q̇ = 4·4.18·(65 − 20) = 752.4 kW

End temperature differences

ΔT₁ = 105 − 20 = 85 K
ΔT₂ = 105 − 65 = 40 K

Log-mean temperature difference

ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) = (85 − 40)/ln(85/40) = 59.7 K

Area

A = Q̇/(U·ΔTlm) = 752400/(3000·59.7) = 4.201 m²

Answer

A = 4.201 m²
4.Heat exchangers (LMTD)

Answer: Th,out = 123.8 °C

LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.

Constant temperature difference

The cold outlet sits opposite the hot inlet: Tc,out = Tc,in + (Th,in − Th,out), so ΔT₁ = Th,in − Tc,out = Th,out − Tc,in = ΔT₂.

ΔTlm = Th,out − Tc,in

Energy balance equals rate equation

2·(175 − Th,out) = 0.9·(Th,out − 10)
Th,out = (2·175 + 0.9·10)/(2 + 0.9) = 123.8 °C

Answer

Th,out = 123.8 °C

Heat transferred: Q̇ = 102.4 kW; the cold stream leaves at 61.21 °C.

ExamProblems · examproblems.com/courses/heat-transfer