Heat Transfer: cram pack

Formula sheets, the key method steps for every topic and 4 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

Heat conduction

Fourier’s law
Q̇ = kAΔT/L
Conduction resistance
R = L/(kA)
Convection resistance
R = 1/(hA)
Resistances in series
Q̇ = ΔTtotal/ΣR
U-value
U = 1/(ΣR·A)

Heat exchangers (LMTD)

Heat duty
Q = U·A·ΔTlm
Log mean temperature difference
ΔTlm = (ΔT1 − ΔT2)/ln(ΔT1/ΔT2)
Stream balance
Q = ṁcp(Tin − Tout)

2Practice problems

1.Heat conductionMedium
Gypsum board, k = 0.1750 mmBrick, k = 0.72100 mm20 °C-13 °CTi​ = ?Q̇

A wall is made of 50 mm of gypsum board and 100 mm of brick, with an area of 20 m². The outer faces are at 20 °C and -13 °C. Find the temperature Ti at the interface between the two layers.

L1 = 50 mm, k1 = 0.17 W/(m·K)L2 = 100 mm, k2 = 0.72 W/(m·K)A = 20 m²T1 = 20 °CT3 = -13 °C
Ti = °C
2.Heat conductionHard
Concrete, k = 1.4150 mmMineral wool, k = 0.04150 mmroom 20 °Coutside 0 °CQ̇ = ?

A wall of 150 mm concrete and 150 mm mineral wool separates a room at 20 °C from outside air at 0 °C. The convection coefficients are 8 W/(m²·K) inside and 30 W/(m²·K) outside, and the wall area is 4 m². Find the heat loss Q̇ through the wall.

L1 = 150 mm, k1 = 1.4 W/(m·K)L2 = 150 mm, k2 = 0.04 W/(m·K)A = 4 m²hi = 8 W/(m²·K)ho = 30 W/(m²·K)Troom = 20 °CTout = 0 °C
Q̇ = W
3.Heat exchangers (LMTD)Medium
lengthT175 °C155 °C125 °C15 °CΔT₁ΔT₂counter-flow

A counter-flow heat exchanger transfers 480 kW. The hot fluid cools from 175 to 155 °C and the cold fluid heats from 15 to 125 °C. The overall heat transfer coefficient is 500 W/(m²·K). Find the heat transfer area A needed.

Q̇ = 480 kWU = 500 W/(m²·K)Th: 175 → 155 °CTc: 15 → 125 °C
A = m²
4.Heat exchangers (LMTD)Hard
lengthT90 °C70 °C33.67 °C30 °CΔT₁ΔT₂counter-flow

Hot oil (1 kg/s, cp = 2.3 kJ/(kg·K)) cools from 90 to 70 °C in a counter-flow exchanger. It heats 3 kg/s of water (cp = 4.18 kJ/(kg·K)) that enters at 30 °C. With U = 200 W/(m²·K), find the heat transfer area A needed.

ṁh = 1 kg/scp,h = 2.3 kJ/(kg·K)Th: 90 → 70 °Cṁc = 3 kg/scp,c = 4.18 kJ/(kg·K)Tc,in = 30 °CU = 200 W/(m²·K)
A = m²

3Solutions

1.Heat conduction

Answer: Ti = −2.415 °C

Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.

Layer resistances

R1 = L1/(k1A) = (50/1000)/(0.17·20) = 0.01471 K/W
R2 = L2/(k2A) = (100/1000)/(0.72·20) = 0.006944 K/W

Heat flow

Q̇ = (T1 − T3)/(R1 + R2) = 33/0.02165 = 1524 W

Interface temperature

The temperature drops across the first layer by Q̇·R₁.

Ti = T1 − Q̇·R1 = 20 − 1524·0.01471 = −2.415 °C

Answer

Ti = −2.415 °C
2.Heat conduction

Answer: Q̇ = 19.92 W

Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.

Resistances in series

Ri = 1/(hiA) = 1/(8·4) = 0.03125 K/W
R1 = L1/(k1A) = (150/1000)/(1.4·4) = 0.02679 K/W
R2 = L2/(k2A) = (150/1000)/(0.04·4) = 0.9375 K/W
Ro = 1/(hoA) = 1/(30·4) = 0.008333 K/W
ΣR = 1.004 K/W

Heat loss

Q̇ = (20 − (0))/1.004 = 19.92 W

Answer

Q̇ = 19.92 W
3.Heat exchangers (LMTD)

Answer: A = 10.98 m²

LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.

End temperature differences

In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.

ΔT₁ = Th,in − Tc,out = 175 − 125 = 50 K
ΔT₂ = Th,out − Tc,in = 155 − 15 = 140 K

Log-mean temperature difference

ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) = (50 − 140)/ln(50/140) = 87.41 K

Area

A = Q̇/(U·ΔTlm) = 480000/(500·87.41) = 10.98 m²

Answer

A = 10.98 m²
4.Heat exchangers (LMTD)

Answer: A = 4.822 m²

LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.

Heat duty and water outlet temperature

Q̇ = ṁhcp,h(Th,in − Th,out) = 1·2.3·20 = 46 kW
Tc,out = 30 + 46/(3·4.18) = 33.67 °C

End temperature differences

In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.

ΔT₁ = Th,in − Tc,out = 90 − 33.67 = 56.33 K
ΔT₂ = Th,out − Tc,in = 70 − 30 = 40 K

Log-mean temperature difference

ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) = (56.33 − 40)/ln(56.33/40) = 47.7 K

Area

A = Q̇/(U·ΔTlm) = 46000/(200·47.7) = 4.822 m²

Answer

A = 4.822 m²

ExamProblems · examproblems.com/courses/heat-transfer