IV Fluids and Fluid Balance: cram pack

Formula sheets, the key method steps for every topic and 4 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

IV fluids & fluid balance

Holliday–Segar per hour
4 mL/kg (first 10 kg) + 2 mL/kg (next 10 kg) + 1 mL/kg (each kg above 20)
Holliday–Segar per day
100 / 50 / 20 mL/kg for the same bands
Fluid balance
intake − output
Ice chips
count as half their volume
Urine output
mL/kg/h = mL / (kg × h)
Infusion time
time (h) = volume left (mL) / rate (mL/h)
Volume infused
mL = rate × time

IV infusion rates

Pump rate
mL/h = volume (mL)/time (h)
Drip rate
drops/min = volume (mL) × drop factor / time (min)
Infusion time
time (h) = volume (mL)/rate (mL/h)

Method

  1. Pump rate in mL/h: volume divided by time in hours.
  2. Drip rate in drops/min: volume × drop factor divided by time in minutes.
  3. For time remaining: volume left divided by the rate.
  4. Round as the question or the equipment requires.

2Practice problems

1.IV fluids & fluid balanceMedium
IntakeOutput8-hour shiftwater250 mLjuice100 mLice chips120 mLIV infusion80 mL/h × 8 hIV antibiotic2 × 50 mLurine325 mLurine300 mLwound drain30 mLvomit250 mL

Practice exercise (made-up values, not clinical guidance). The record shows a patient's intake and output for one 8-hour shift. The patient weighs 59 kg. Find the average urine output U in mL/kg/h. Round to two decimal places.

59 kg8 hurine: 325 mLurine: 300 mLwound drain: 30 mLvomit: 250 mL
U = mL/kg/h
2.IV fluids & fluid balanceHard
500 mL→ 75 mL/hstart 16:30ttotal​ = ? h100 mL/h × 4 h

Practice exercise (made-up values, not clinical guidance). A 500 mL infusion starts at 16:30 at 100 mL/h. After 4 hours the rate is changed to 75 mL/h and is not changed again. How many hours t after the start will the bag be empty? Round to one decimal place.

500 mL100 mL/h · 4 h75 mL/h
t = h
3.IV infusion ratesMedium
210 mLleft? mL/h2 h left

500 mL was ordered over 6 hours. After 4 hours you find that 210 mL is still in the bag, and the order must still finish on time. To what rate R in mL/h must the pump be reset?

500 mL / 6 hafter 4 h: 210 mL
R = mL/h
4.IV infusion ratesHard
450 mL15 gtt/mL20 gtt/mint = ? h

A drip runs at 20 gtt/min through a set of 15 gtt/mL. There are 450 mL left in the bag. How many hours t until it is empty? Round to one decimal place.

20 gtt/min15 gtt/mL450 mL
t = h

3Solutions

1.IV fluids & fluid balance

Answer: U = 1.32 mL/kg/h

Intake and output: intake counts everything that goes in (oral fluids, IV infusions, IV medications and flushes, tube feeds); ice chips count as half their volume. Output counts urine, drains, vomit and other losses. Balance = total intake − total output; a negative balance is a net loss. The numbers are for practice only; at the bedside always follow local protocols and have high-risk doses double-checked.

Total urine

325 + 300 = 625 mL

Per kilogram per hour

U = 625/(59·8) = 1.324 ≈ 1.32 mL/kg/h

Answer

U = 1.32 mL/kg/h
2.IV fluids & fluid balance

Answer: t = 5.3 h

Infusion time: time (h) = volume to infuse (mL)/rate (mL/h); use the volume still left in the bag, not the bag size. Volume infused = rate × time. Convert decimal hours to hours and minutes with the fraction × 60 (0.5 h = 30 min, not 50 min). The numbers are for practice only; at the bedside always follow local protocols and have high-risk doses double-checked.

First part

100·4 = 400 mL
500 − 400 = 100 mL left

Second part

100/75 = 1.333 h

Total time

t = 4 + 1.333 = 5.333 ≈ 5.3 h

Answer

t = 5.3 h

That is about 5 h 20 min, so the bag runs out at about 21:50.

3.IV infusion rates

Answer: R = 105 mL/h

Infusion rates: a pump is set in mL/h = volume/time in hours. A gravity drip is counted in drops per minute: gtt/min = volume (mL) × drop factor (gtt/mL)/time (min). The drop factor is printed on the tubing package: macrodrip sets deliver 10, 15 or 20 gtt/mL (blood sets often 10 gtt/mL in the US, 15 in the UK) and microdrip sets 60 gtt/mL. Always use the drop factor the question or package gives.

Original rate

500/6 = 83.33 mL/h

New rate

R = 210/2 = 105 mL/h

Answer

R = 105 mL/h

This is more than a 25% increase: most hospitals require you to contact the prescriber instead of catching up, and to assess the patient for fluid overload.

4.IV infusion rates

Answer: t = 5.6 h

Infusion rates: a pump is set in mL/h = volume/time in hours. A gravity drip is counted in drops per minute: gtt/min = volume (mL) × drop factor (gtt/mL)/time (min). The drop factor is printed on the tubing package: macrodrip sets deliver 10, 15 or 20 gtt/mL (blood sets often 10 gtt/mL in the US, 15 in the UK) and microdrip sets 60 gtt/mL. Always use the drop factor the question or package gives.

Rate in mL/h

20·60/15 = 80 mL/h

Time left

t = 450/80 = 5.625 ≈ 5.6 h

Answer

t = 5.6 h