Power Electronics and Drives: cram pack

Formula sheets, the key method steps for every topic and 8 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

DC-DC converters

Buck
Vo = D·Vin
Boost
Vo = Vin/(1 − D)
Inverting buck-boost
|Vo| = Vin·D/(1 − D)
Ideal power balance
VinIin = VoIo
Inductor ripple
ΔIL = VL,on·D/(L·f); buck Vin − Vo, boost and buck-boost Vin
Average inductor current
buck Io; boost and buck-boost Io/(1 − D)
Output ripple
buck ΔIL/(8fC); boost and buck-boost Io·D/(fC)
CCM boundary
buck (1 − D)R/(2f); boost D(1 − D)²R/(2f); buck-boost (1 − D)²R/(2f)

Method

  1. Identify the converter (buck, boost or buck-boost) and the duty cycle D from the voltage ratio.
  2. Use volt-second balance on the inductor: the average inductor voltage over a period is zero.
  3. Find the inductor voltage while the switch is on, then ΔIL = VL·D/(L·f).
  4. For the output ripple, find the charge that flows in and out of the capacitor; for the CCM boundary, set the average inductor current equal to ΔIL/2.

DC motors

Armature circuit
V = E + IaRa
Back-EMF and torque
E = k·ω, T = k·Ia
Speed
ω = 2π·n/60, ω = (V − IaRa)/k
No-load speed and stall torque
ω0 = V/k, Tstall = k·V/Ra
Powers
Pin = V·Ia, Pdev = E·Ia = T·ω, Pout = Pdev − Prot
Starting
Istart = V/(Ra + Rst)
Speed regulation
SR = (n0 − nFL)/nFL
Maximum developed power
Pmax = V²/(4Ra)
Chopper drive
Va = D·Vdc

Method

  1. Draw the armature circuit: supply V, resistance Ra and the back-EMF E in series.
  2. Use V = E + Ia·Ra to link voltage, current and back-EMF.
  3. Use E = k·ω for speed and T = k·Ia for torque, with ω = 2π·n/60.
  4. For power and efficiency, start from V·Ia, subtract the copper loss Ia²·Ra and then the rotational losses.

AC power & power factor

Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)

Three-phase power

Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η

2Practice problems

1.DC-DC convertersMedium
tiL​Imax​Imin​ΔI = ?DTT2T

An ideal boost converter turns 12 V into 30 V at 250 kHz with L = 47 µH. Find the peak-to-peak inductor ripple current ΔIL.

Vin​ = 12 VVo​ = 30 Vf = 250 kHzL = 47 µH
ΔIL = A
2.DC-DC convertersHard
+−48 VSLC = 100 µFR = 2 Ω−+−144 V

An ideal buck-boost converter turns 48 V into −144 V for a 2 Ω load at 200 kHz. The output capacitor is 100 µF. Find the peak-to-peak output voltage ripple ΔVo in mV.

Vin​ = 48 VVo​ = −144 Vf = 200 kHzC = 100 µFR = 2 Ω
ΔVo = mV
3.DC motorsMedium
T (N·m)n (rpm)n0​ = ?

A DC motor with k = 0.15 V·s/rad runs from 48 V. Neglecting all losses at no load, find its no-load speed n0 in rpm.

V = 48 Vk = 0.15 V·s/rad
n0 = rpm
4.DC motorsHard
+−120 VRa​ = 1.5 ΩM+−En = ?T = 6 N·m

A separately excited DC motor (k = 1.5 V·s/rad at full field, Ra = 1.5 Ω, V = 120 V) drives a constant load torque of 6 N·m. The field flux is reduced to 75 % of its full value. Find the new speed n.

V = 120 Vk = 1.5 V·s/radRa = 1.5 ΩT = 6 N·mΦ = 75 %
n = rpm
5.AC power & power factorMedium
240 VR + jXP = 4104 W19 A

An inductive load takes 19 A and 4104 W from a 240 V (rms) single-phase supply. Model it as a resistance R in series with a reactance X. Find X.

V = 240 VI = 19 AP = 4104 W
X = Ω
6.AC power & power factorHard
P = 25 kWQ1​S1​φ1​QC​

A single-phase load takes 25 kW at a power factor of 0.8 lagging from a 400 V, 60 Hz supply. A capacitor connected in parallel raises the power factor to 0.9. Find the reactive power QC the capacitor must supply.

P = 25 kWpf1 = 0.8pf2 = 0.9V = 400 Vf = 60 Hz
QC = kvar
7.Three-phase powerMedium
ABCVL​ = 415 VIL​ = 150 Acos φ = 0.75lagging

A balanced three-phase load draws a line current of 150 A from a supply with a line-to-line voltage of 415 V. The power factor is 0.75 lagging. Find the total real power P drawn by the load in kW.

VL = 415 VIL = 150 Acos φ = 0.75
P = kW
8.Three-phase powerHard
P = 250 kWφ1​S1​Q2​QC​ = ?

A balanced three-phase load takes 250 kW at a power factor of 0.7 lagging from a 480 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.92 lagging. The real power stays the same. Find the total reactive power QC the capacitor bank must supply, in kvar.

P = 250 kWpf1 = 0.7pf2 = 0.92VL = 480 Vf = 50 Hz
QC = kvar

3Solutions

1.DC-DC converters

Answer: ΔIL = 0.6128 A

DC-DC converters: a switch S turns on for the fraction D of each period T = 1/f. In steady state the average inductor voltage is zero (volt-second balance), which gives the ideal conversion ratios in continuous conduction: buck Vo = D·Vin, boost Vo = Vin/(1 − D), inverting buck-boost |Vo| = Vin·D/(1 − D). An ideal converter keeps the power: Vin·Iin = Vo·Io. While S is on the inductor current rises by ΔIL = VL·D·T/L, with VL = Vin − Vo for the buck and Vin for the boost and buck-boost. The output ripple is ΔVo = ΔIL/(8fC) for the buck and Io·D/(fC) for the boost and buck-boost. The inductor current just touches zero (the CCM boundary) when the average inductor current equals ΔIL/2.

Duty cycle

D = 1 − 12/30 = 0.6

Inductor voltage during the on-time

While S is on, the inductor sits directly across Vin.

VL = 12 V

Ripple current

ΔIL = VL·D/(L·f) = 12·0.6/(47·10⁻⁶·250·10³) = 0.6128 A

Answer

ΔIL = 0.6128 A
2.DC-DC converters

Answer: ΔVo = 2700 mV

DC-DC converters: a switch S turns on for the fraction D of each period T = 1/f. In steady state the average inductor voltage is zero (volt-second balance), which gives the ideal conversion ratios in continuous conduction: buck Vo = D·Vin, boost Vo = Vin/(1 − D), inverting buck-boost |Vo| = Vin·D/(1 − D). An ideal converter keeps the power: Vin·Iin = Vo·Io. While S is on the inductor current rises by ΔIL = VL·D·T/L, with VL = Vin − Vo for the buck and Vin for the boost and buck-boost. The output ripple is ΔVo = ΔIL/(8fC) for the buck and Io·D/(fC) for the boost and buck-boost. The inductor current just touches zero (the CCM boundary) when the average inductor current equals ΔIL/2.

Duty cycle

D = 144/(48 + 144) = 0.75

Load current

Io = 144/2 = 72 A

Output ripple

ΔVo = 72·0.75/(200·10³·100·10⁻⁶) = 2700 mV

Answer

ΔVo = 2700 mV
3.DC motors

Answer: n0 = 3056 rpm

DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.

No-load speed

ω₀ = V/k = 48/0.15 = 320 rad/s
n0 = 60·320/(2π) = 3056 rpm

Answer

n0 = 3056 rpm
4.DC motors

Answer: n = 950.7 rpm

DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.

Weakened motor constant

k₂ = 0.75·1.5 = 1.125 V·s/rad

New armature current

Ia = 6/1.125 = 5.333 A

New speed

ω = (120 − 5.333·1.5)/1.125 = 99.56 rad/s → n = 950.7 rpm

Answer

n = 950.7 rpm

Field weakening is how a DC drive runs above its base speed.

5.AC power & power factor

Answer: X = 5.506 Ω

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Resistance from the real power

R = P/I² = 4104/19² = 11.37 Ω

Reactance from the impedance

|Z| = V/I = 240/19 = 12.63 Ω
X = √(|Z|² − R²) = √(12.63² − 11.37²) = 5.506 Ω

Answer

X = 5.506 Ω
6.AC power & power factor

Answer: QC = 6.642 kvar

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Reactive power before and after

The real power P does not change; only the reactive power drawn from the supply does.

Q1 = P·tan φ1 = 25·tan(36.87°) = 18.75 kvar
Q2 = P·tan φ2 = 25·tan(25.84°) = 12.11 kvar
QC = Q1 − Q2 = 6.642 kvar

Answer

QC = 6.642 kvar
7.Three-phase power

Answer: P = 80.87 kW

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.

Apparent power

S = √3·VL·IL = √3·415·150 = 107.8 kVA

Real power

P = S·cos φ = 107.8·0.75 = 80.87 kW

Answer

P = 80.87 kW
8.Three-phase power

Answer: QC = 148.6 kvar

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.

Reactive power before and after

The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.

Q1 = 250·tan(acos 0.7) = 250·1.02 = 255.1 kvar
Q2 = 250·tan(acos 0.92) = 250·0.426 = 106.5 kvar

Reactive power from the capacitors

QC = Q1 − Q2 = 148.6 kvar

Answer

QC = 148.6 kvar

ExamProblems · examproblems.com/courses/power-electronics