Identify the converter (buck, boost or buck-boost) and the duty cycle D from the voltage ratio.
Use volt-second balance on the inductor: the average inductor voltage over a period is zero.
Find the inductor voltage while the switch is on, then ΔIL = VL·D/(L·f).
For the output ripple, find the charge that flows in and out of the capacitor; for the CCM boundary, set the average inductor current equal to ΔIL/2.
DC motors
Armature circuit
V = E + IaRa
Back-EMF and torque
E = k·ω, T = k·Ia
Speed
ω = 2π·n/60, ω = (V − IaRa)/k
No-load speed and stall torque
ω0 = V/k, Tstall = k·V/Ra
Powers
Pin = V·Ia, Pdev = E·Ia = T·ω, Pout = Pdev − Prot
Starting
Istart = V/(Ra + Rst)
Speed regulation
SR = (n0 − nFL)/nFL
Maximum developed power
Pmax = V²/(4Ra)
Chopper drive
Va = D·Vdc
Method
Draw the armature circuit: supply V, resistance Ra and the back-EMF E in series.
Use V = E + Ia·Ra to link voltage, current and back-EMF.
Use E = k·ω for speed and T = k·Ia for torque, with ω = 2π·n/60.
For power and efficiency, start from V·Ia, subtract the copper loss Ia²·Ra and then the rotational losses.
AC power & power factor
Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)
Three-phase power
Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η
2Practice problems
1.DC-DC convertersMedium
A buck converter turns 36 V into 27 V for a 2 Ω load. It switches at 500 kHz with L = 22 µH. Find the peak inductor current Imax.
Vin = 36 VVo = 27 Vf = 500 kHzL = 22 µHR = 2 Ω
Imax = A
2.DC-DC convertersHard
An ideal buck-boost converter turns 12 V into −12 V for a 2 Ω load at 40 kHz. The output capacitor is 10 µF. Find the peak-to-peak output voltage ripple ΔVo in mV.
Vin = 12 VVo = −12 Vf = 40 kHzC = 10 µFR = 2 Ω
ΔVo = mV
3.DC motorsMedium
A DC motor with k = 2 V·s/rad runs from 220 V. Neglecting all losses at no load, find its no-load speed n0 in rpm.
V = 220 Vk = 2 V·s/rad
n0 = rpm
4.DC motorsHard
A separately excited DC motor (k = 0.2 V·s/rad at full field, Ra = 1 Ω, V = 24 V) drives a constant load torque of 0.4 N·m. The field flux is reduced to 90 % of its full value. Find the new speed n.
A single-phase motor takes 9 kW at a power factor of 0.7 lagging from a 230 V supply. Find the line current I.
P = 9 kWpf = 0.7V = 230 V
I = A
6.AC power & power factorHard
A single-phase load takes 5 kW at a power factor of 0.75 lagging from a 230 V, 60 Hz supply. A capacitor connected in parallel raises the power factor to 0.9. Find the capacitance C needed.
P = 5 kWpf1 = 0.75pf2 = 0.9V = 230 Vf = 60 Hz
C = µF
7.Three-phase powerMedium
A balanced three-phase load draws a line current of 10 A from a supply with a line-to-line voltage of 690 V. The power factor is 0.75 lagging. Find the total real power P drawn by the load in kW.
VL = 690 VIL = 10 Acos φ = 0.75
P = kW
8.Three-phase powerHard
A balanced three-phase load takes 150 kW at a power factor of 0.78 lagging from a 400 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.95 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.
P = 150 kWpf1 = 0.78pf2 = 0.95VL = 400 Vf = 60 Hz
Cph = µF
3Solutions
1.DC-DC converters
Answer: Imax = 13.81 A
DC-DC converters: a switch S turns on for the fraction D of each period T = 1/f. In steady state the average inductor voltage is zero (volt-second balance), which gives the ideal conversion ratios in continuous conduction: buck Vo = D·Vin, boost Vo = Vin/(1 − D), inverting buck-boost |Vo| = Vin·D/(1 − D). An ideal converter keeps the power: Vin·Iin = Vo·Io. While S is on the inductor current rises by ΔIL = VL·D·T/L, with VL = Vin − Vo for the buck and Vin for the boost and buck-boost. The output ripple is ΔVo = ΔIL/(8fC) for the buck and Io·D/(fC) for the boost and buck-boost. The inductor current just touches zero (the CCM boundary) when the average inductor current equals ΔIL/2.
Duty cycle
D = 27/36 = 0.75
Average and ripple current
Io = 27/2 = 13.5 A
ΔIL = VL·D/(L·f) = 9·0.75/(22·10⁻⁶·500·10³) = 0.6136 A
Peak current
Imax = 13.5 + 0.6136/2 = 13.81 A
Answer
Imax = 13.81 A
2.DC-DC converters
Answer: ΔVo = 7500 mV
DC-DC converters: a switch S turns on for the fraction D of each period T = 1/f. In steady state the average inductor voltage is zero (volt-second balance), which gives the ideal conversion ratios in continuous conduction: buck Vo = D·Vin, boost Vo = Vin/(1 − D), inverting buck-boost |Vo| = Vin·D/(1 − D). An ideal converter keeps the power: Vin·Iin = Vo·Io. While S is on the inductor current rises by ΔIL = VL·D·T/L, with VL = Vin − Vo for the buck and Vin for the boost and buck-boost. The output ripple is ΔVo = ΔIL/(8fC) for the buck and Io·D/(fC) for the boost and buck-boost. The inductor current just touches zero (the CCM boundary) when the average inductor current equals ΔIL/2.
Duty cycle
D = 12/(12 + 12) = 0.5
Load current
Io = 12/2 = 6 A
Output ripple
ΔVo = 6·0.5/(40·10³·10·10⁻⁶) = 7500 mV
Answer
ΔVo = 7500 mV
3.DC motors
Answer: n0 = 1050 rpm
DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.
No-load speed
ω₀ = V/k = 220/2 = 110 rad/s
n0 = 60·110/(2π) = 1050 rpm
Answer
n0 = 1050 rpm
4.DC motors
Answer: n = 1155 rpm
DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.
Field weakening is how a DC drive runs above its base speed.
5.AC power & power factor
Answer: I = 55.9 A
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Line current
Only the real part of the power does work, so divide by the power factor.
I = P/(V·cos φ) = 9000/(230·0.7) = 55.9 A
Answer
I = 55.9 A
6.AC power & power factor
Answer: C = 99.68 µF
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = P·tan φ1 = 5·tan(41.41°) = 4.41 kvar
Q2 = P·tan φ2 = 5·tan(25.84°) = 2.422 kvar
QC = Q1 − Q2 = 1.988 kvar
Capacitance
A capacitor across the supply delivers Q = V²·ωC.
C = QC/(2πf·V²) = 1988/(2π·60·230²) = 99.68 µF
Answer
C = 99.68 µF
7.Three-phase power
Answer: P = 8.963 kW
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Apparent power
S = √3·VL·IL = √3·690·10 = 11.95 kVA
Real power
P = S·cos φ = 11.95·0.75 = 8.963 kW
Answer
P = 8.963 kW
8.Three-phase power
Answer: Cph = 392.6 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 150·tan(acos 0.78) = 150·0.8023 = 120.3 kvar
Q2 = 150·tan(acos 0.95) = 150·0.3287 = 49.3 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 71.04 kvar
Capacitance per phase
In a Δ bank each capacitor is connected between two lines.