A buck converter turns 36 V into 9 V at 250 kHz with L = 47 µH. Find the smallest load current Io,min for which it stays in continuous conduction.
Vin = 36 VVo = 9 Vf = 250 kHzL = 47 µH
Io,min = A
3.DC motorsMedium
A DC motor (k = 1 V·s/rad, Ra = 2 Ω) runs from 220 V. At full load it draws 5 A. Neglecting the no-load current, find its speed regulation SR = (n₀ − nFL)/nFL in percent.
V = 220 Vk = 1 V·s/radRa = 2 ΩIFL = 5 A
SR = %
4.DC motorsHard
A separately excited DC motor on 120 V (Ra = 0.8 Ω) runs at 900 rpm with an armature current of 15 A. The load changes and the current becomes 6 A, with the field unchanged. Find the new speed n2.
V = 120 VRa = 0.8 Ωn1 = 900 rpmIa1 = 15 AIa2 = 6 A
n2 = rpm
5.AC power & power factorMedium
Two loads are connected in parallel to a 400 V single-phase supply: a 13 kW load at a power factor of 0.75 lagging and a 9 kW load at a power factor of 0.8 lagging. Find the total current I drawn from the supply.
A 24 V (rms), 50 Hz source has an internal impedance Zs = 8 + j20 Ω. The load impedance ZL can be chosen freely. The load for maximum power is built from a resistor in series with a capacitor. Find the capacitance C.
Vs = 24 V (rms)f = 50 HzZs = 8 + j20 Ω
C = µF
7.Three-phase powerMedium
A three-phase induction motor delivers 45 kW of mechanical output power at full load. At this load its efficiency is 91% and its power factor is 0.82 lagging. The supply has a line-to-line voltage of 480 V. Find the line current IL.
Pout = 45 kWη = 91%cos φ = 0.82VL = 480 V
IL = A
8.Three-phase powerHard
A balanced three-phase load takes 200 kW at a power factor of 0.8 lagging from a 690 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.9 lagging. The real power stays the same. The capacitors are connected in Y. Find the capacitance Cph of each capacitor in µF.
P = 200 kWpf1 = 0.8pf2 = 0.9VL = 690 Vf = 60 Hz
Cph = µF
3Solutions
1.DC-DC converters
Answer: Imax = 1.829 A
DC-DC converters: a switch S turns on for the fraction D of each period T = 1/f. In steady state the average inductor voltage is zero (volt-second balance), which gives the ideal conversion ratios in continuous conduction: buck Vo = D·Vin, boost Vo = Vin/(1 − D), inverting buck-boost |Vo| = Vin·D/(1 − D). An ideal converter keeps the power: Vin·Iin = Vo·Io. While S is on the inductor current rises by ΔIL = VL·D·T/L, with VL = Vin − Vo for the buck and Vin for the boost and buck-boost. The output ripple is ΔVo = ΔIL/(8fC) for the buck and Io·D/(fC) for the boost and buck-boost. The inductor current just touches zero (the CCM boundary) when the average inductor current equals ΔIL/2.
Duty cycle
D = 3.6/12 = 0.3
Average and ripple current
Io = 3.6/2 = 1.8 A
ΔIL = VL·D/(L·f) = 8.4·0.3/(220·10⁻⁶·200·10³) = 0.05727 A
Peak current
Imax = 1.8 + 0.05727/2 = 1.829 A
Answer
Imax = 1.829 A
2.DC-DC converters
Answer: Io,min = 0.2872 A
DC-DC converters: a switch S turns on for the fraction D of each period T = 1/f. In steady state the average inductor voltage is zero (volt-second balance), which gives the ideal conversion ratios in continuous conduction: buck Vo = D·Vin, boost Vo = Vin/(1 − D), inverting buck-boost |Vo| = Vin·D/(1 − D). An ideal converter keeps the power: Vin·Iin = Vo·Io. While S is on the inductor current rises by ΔIL = VL·D·T/L, with VL = Vin − Vo for the buck and Vin for the boost and buck-boost. The output ripple is ΔVo = ΔIL/(8fC) for the buck and Io·D/(fC) for the boost and buck-boost. The inductor current just touches zero (the CCM boundary) when the average inductor current equals ΔIL/2.
Duty cycle
D = 9/36 = 0.25
Ripple current
ΔIL = 9·0.75/(47·10⁻⁶·250·10³) = 0.5745 A
Boundary load current
Io,min = ΔIL/2 = 0.2872 A
Answer
Io,min = 0.2872 A
Below this current the converter enters discontinuous conduction and Vo rises above D·Vin.
3.DC motors
Answer: SR = 4.762 %
DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.
No-load and full-load speed
n₀ = 60·220/(2π·1) = 2101 rpm
nFL = 60·(220 − 5·2)/(2π·1) = 2005 rpm
Speed regulation
SR = (2101 − 2005)/2005·100 = 4.762 %
Answer
SR = 4.762 %
4.DC motors
Answer: n2 = 960 rpm
DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.
Back-EMF before and after
E1 = 120 − 15·0.8 = 108 V
E2 = 120 − 6·0.8 = 115.2 V
New speed
n2 = 900·115.2/108 = 960 rpm
Answer
n2 = 960 rpm
5.AC power & power factor
Answer: I = 71.4 A
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power of each load
A lagging load takes reactive power (Q > 0); a leading load supplies it (Q < 0).
Q1 = 13·tan(arccos 0.75) = 11.46 kvar
Q2 = 9·tan(arccos 0.8) = 6.75 kvar
Totals
P = 13 + 9 = 22 kW
Q = 11.46 + 6.75 = 18.21 kvar
S = √(22² + 18.21²) = 28.56 kVA
Total current
I = S/V = 28562/400 = 71.4 A
Answer
I = 71.4 A
6.AC power & power factor
Answer: C = 159.2 µF
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Conjugate match
The load reactance cancels the source reactance, and the load resistance equals the source resistance.
ZL = Zs* = 8 − j20 Ω
Capacitance
XC = 20 Ω → C = 1/(2π·50·20) = 159.2 µF
Answer
C = 159.2 µF
7.Three-phase power
Answer: IL = 72.54 A
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Electrical input power
Pin = Pout/η = 45/0.91 = 49.45 kW
Line current
IL = Pin/(√3·VL·cos φ) = 49451/(√3·480·0.82) = 72.54 A
Answer
IL = 72.54 A
8.Three-phase power
Answer: Cph = 296 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 200·tan(acos 0.8) = 200·0.75 = 150 kvar
Q2 = 200·tan(acos 0.9) = 200·0.4843 = 96.86 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 53.14 kvar
Capacitance per phase
In a Y bank each capacitor is connected between a line and the star point.