Power Electronics and Drives: cram pack

Formula sheets, the key method steps for every topic and 8 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

DC-DC converters

Buck
Vo = D·Vin
Boost
Vo = Vin/(1 − D)
Inverting buck-boost
|Vo| = Vin·D/(1 − D)
Ideal power balance
VinIin = VoIo
Inductor ripple
ΔIL = VL,on·D/(L·f); buck Vin − Vo, boost and buck-boost Vin
Average inductor current
buck Io; boost and buck-boost Io/(1 − D)
Output ripple
buck ΔIL/(8fC); boost and buck-boost Io·D/(fC)
CCM boundary
buck (1 − D)R/(2f); boost D(1 − D)²R/(2f); buck-boost (1 − D)²R/(2f)

Method

  1. Identify the converter (buck, boost or buck-boost) and the duty cycle D from the voltage ratio.
  2. Use volt-second balance on the inductor: the average inductor voltage over a period is zero.
  3. Find the inductor voltage while the switch is on, then ΔIL = VL·D/(L·f).
  4. For the output ripple, find the charge that flows in and out of the capacitor; for the CCM boundary, set the average inductor current equal to ΔIL/2.

DC motors

Armature circuit
V = E + IaRa
Back-EMF and torque
E = k·ω, T = k·Ia
Speed
ω = 2π·n/60, ω = (V − IaRa)/k
No-load speed and stall torque
ω0 = V/k, Tstall = k·V/Ra
Powers
Pin = V·Ia, Pdev = E·Ia = T·ω, Pout = Pdev − Prot
Starting
Istart = V/(Ra + Rst)
Speed regulation
SR = (n0 − nFL)/nFL
Maximum developed power
Pmax = V²/(4Ra)
Chopper drive
Va = D·Vdc

Method

  1. Draw the armature circuit: supply V, resistance Ra and the back-EMF E in series.
  2. Use V = E + Ia·Ra to link voltage, current and back-EMF.
  3. Use E = k·ω for speed and T = k·Ia for torque, with ω = 2π·n/60.
  4. For power and efficiency, start from V·Ia, subtract the copper loss Ia²·Ra and then the rotational losses.

AC power & power factor

Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)

Three-phase power

Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η

2Practice problems

1.DC-DC convertersMedium
+−15 VLSCR = 25 Ω+−37.5 V

An ideal boost converter turns 15 V into 37.5 V for a 25 Ω load. Find the average inductor current IL.

Vin​ = 15 VVo​ = 37.5 VR = 25 Ω
IL = A
2.DC-DC convertersHard
+−24 VSLC = 470 µFR = 10 Ω−+−36 V

An ideal buck-boost converter turns 24 V into −36 V for a 10 Ω load at 50 kHz. The output capacitor is 470 µF. Find the peak-to-peak output voltage ripple ΔVo in mV.

Vin​ = 24 VVo​ = −36 Vf = 50 kHzC = 470 µFR = 10 Ω
ΔVo = mV
3.DC motorsMedium
+−VRa​M+−En = 2900 rpmT = ?

A DC motor delivers 0.75 kW of mechanical power at 2900 rpm. Find the shaft torque T.

P = 0.75 kWn = 2900 rpm
T = N·m
4.DC motorsHard
+−120 VRst​ = ?Ra​ = 1.5 Ω10 AM+−E = 0n = 0T

A 120 V DC motor has an armature resistance of 1.5 Ω. Find the series starting resistance Rst that limits the starting current to 10 A.

V = 120 VRa = 1.5 ΩImax = 10 A
Rst = Ω
5.AC power & power factorMedium
P = 8 kWQSφ

A single-phase motor takes 8 kW at a power factor of 0.75 lagging from a 230 V supply. Find the line current I.

P = 8 kWpf = 0.75V = 230 V
I = A
6.AC power & power factorHard
P = 40 kWQ1​S1​φ1​QC​

A single-phase load takes 40 kW at a power factor of 0.7 lagging from a 400 V, 60 Hz supply. A capacitor connected in parallel raises the power factor to 0.92. Find the new line current Inew.

P = 40 kWpf1 = 0.7pf2 = 0.92V = 400 Vf = 60 Hz
Inew = A
7.Three-phase powerMedium
ABCVL​ = 415 VIL​ = 150 Acos φ = 0.8lagging

A balanced three-phase load draws a line current of 150 A from a supply with a line-to-line voltage of 415 V. The power factor is 0.8 lagging. Find the total real power P drawn by the load in kW.

VL = 415 VIL = 150 Acos φ = 0.8
P = kW
8.Three-phase powerHard
P = 250 kWφ1​S1​Q2​QC​

A balanced three-phase load takes 250 kW at a power factor of 0.65 lagging from a 415 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.98 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.

P = 250 kWpf1 = 0.65pf2 = 0.98VL = 415 Vf = 60 Hz
Cph = µF

3Solutions

1.DC-DC converters

Answer: IL = 3.75 A

DC-DC converters: a switch S turns on for the fraction D of each period T = 1/f. In steady state the average inductor voltage is zero (volt-second balance), which gives the ideal conversion ratios in continuous conduction: buck Vo = D·Vin, boost Vo = Vin/(1 − D), inverting buck-boost |Vo| = Vin·D/(1 − D). An ideal converter keeps the power: Vin·Iin = Vo·Io. While S is on the inductor current rises by ΔIL = VL·D·T/L, with VL = Vin − Vo for the buck and Vin for the boost and buck-boost. The output ripple is ΔVo = ΔIL/(8fC) for the buck and Io·D/(fC) for the boost and buck-boost. The inductor current just touches zero (the CCM boundary) when the average inductor current equals ΔIL/2.

Duty cycle

D = 1 − 15/37.5 = 0.6

Load current

Io = 37.5/25 = 1.5 A

Inductor current

IL = Io/(1 − D) = 1.5/0.4 = 3.75 A

Answer

IL = 3.75 A
2.DC-DC converters

Answer: ΔVo = 91.91 mV

DC-DC converters: a switch S turns on for the fraction D of each period T = 1/f. In steady state the average inductor voltage is zero (volt-second balance), which gives the ideal conversion ratios in continuous conduction: buck Vo = D·Vin, boost Vo = Vin/(1 − D), inverting buck-boost |Vo| = Vin·D/(1 − D). An ideal converter keeps the power: Vin·Iin = Vo·Io. While S is on the inductor current rises by ΔIL = VL·D·T/L, with VL = Vin − Vo for the buck and Vin for the boost and buck-boost. The output ripple is ΔVo = ΔIL/(8fC) for the buck and Io·D/(fC) for the boost and buck-boost. The inductor current just touches zero (the CCM boundary) when the average inductor current equals ΔIL/2.

Duty cycle

D = 36/(24 + 36) = 0.6

Load current

Io = 36/10 = 3.6 A

Output ripple

ΔVo = 3.6·0.6/(50·10³·470·10⁻⁶) = 91.91 mV

Answer

ΔVo = 91.91 mV
3.DC motors

Answer: T = 2.47 N·m

DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.

Speed in rad/s

ω = 2π·2900/60 = 303.7 rad/s

Torque

T = P/ω = 750/303.7 = 2.47 N·m

Answer

T = 2.47 N·m
4.DC motors

Answer: Rst = 10.5 Ω

DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.

Total resistance

Ra + Rst = 120/10 = 12 Ω

Starting resistor

Rst = 12 − 1.5 = 10.5 Ω

Answer

Rst = 10.5 Ω

The resistor is cut out step by step as the motor speeds up and the back-EMF grows.

5.AC power & power factor

Answer: I = 46.38 A

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Line current

Only the real part of the power does work, so divide by the power factor.

I = P/(V·cos φ) = 8000/(230·0.75) = 46.38 A

Answer

I = 46.38 A
6.AC power & power factor

Answer: Inew = 108.7 A

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Reactive power before and after

The real power P does not change; only the reactive power drawn from the supply does.

Q1 = P·tan φ1 = 40·tan(45.57°) = 40.81 kvar
Q2 = P·tan φ2 = 40·tan(23.07°) = 17.04 kvar
QC = Q1 − Q2 = 23.77 kvar

New line current

Inew = P/(V·cos φ2) = 40000/(400·0.92) = 108.7 A

Answer

Inew = 108.7 A
7.Three-phase power

Answer: P = 86.26 kW

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.

Apparent power

S = √3·VL·IL = √3·415·150 = 107.8 kVA

Real power

P = S·cos φ = 107.8·0.8 = 86.26 kW

Answer

P = 86.26 kW
8.Three-phase power

Answer: Cph = 1240 µF

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.

Reactive power before and after

The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.

Q1 = 250·tan(acos 0.65) = 250·1.169 = 292.3 kvar
Q2 = 250·tan(acos 0.98) = 250·0.2031 = 50.76 kvar

Reactive power from the capacitors

QC = Q1 − Q2 = 241.5 kvar

Capacitance per phase

In a Δ bank each capacitor is connected between two lines.

V = 415 V, ω = 2π·60 = 377 rad/s
Cph = (QC/3)/(ω·V²) = 80506/(377·415²) = 1240 µF

Answer

Cph = 1240 µF

ExamProblems · examproblems.com/courses/power-electronics