In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Three-phase power
Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η
Transformers
Turns ratio
a = N1/N2 = V1/V2
Current ratio
I1/I2 = N2/N1 = 1/a
Rated current
I = S/V
Referred impedance
Z1′ = a²·ZL
Copper loss at part load
Pcu = x²·Pcu,fl
Efficiency
η = x·S·pf/(x·S·pf + Pcore + x²·Pcu,fl)
Maximum efficiency
x = √(Pcore/Pcu,fl)
AC power & power factor
Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)
AC impedance & phasors
Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z
Method
Convert the frequency: ω = 2πf.
Find each reactance: XL = ωL and XC = 1/(ωC).
Add impedances like resistors, with Z = R + jX.
Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.
DC motors
Armature circuit
V = E + IaRa
Back-EMF and torque
E = k·ω, T = k·Ia
Speed
ω = 2π·n/60, ω = (V − IaRa)/k
No-load speed and stall torque
ω0 = V/k, Tstall = k·V/Ra
Powers
Pin = V·Ia, Pdev = E·Ia = T·ω, Pout = Pdev − Prot
Starting
Istart = V/(Ra + Rst)
Speed regulation
SR = (n0 − nFL)/nFL
Maximum developed power
Pmax = V²/(4Ra)
Chopper drive
Va = D·Vdc
Method
Draw the armature circuit: supply V, resistance Ra and the back-EMF E in series.
Use V = E + Ia·Ra to link voltage, current and back-EMF.
Use E = k·ω for speed and T = k·Ia for torque, with ω = 2π·n/60.
For power and efficiency, start from V·Ia, subtract the copper loss Ia²·Ra and then the rotational losses.
2Practice problems
1.Three-phase powerMedium
A balanced Y-connected load with an impedance of 24 + j18 Ω per phase is connected to a balanced three-phase supply with a line-to-line voltage of 480 V. Find the total real power P absorbed by the load in kW.
VL = 480 VZ = 24 + j18 Ω per phase
P = kW
2.Three-phase powerHard
A balanced three-phase load takes 250 kW at a power factor of 0.7 lagging from a 400 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.98 lagging. The real power stays the same. Find the total reactive power QC the capacitor bank must supply, in kvar.
P = 250 kWpf1 = 0.7pf2 = 0.98VL = 400 Vf = 60 Hz
QC = kvar
3.TransformersMedium
A 5 Ω resistor is connected across the secondary winding of an ideal transformer with a turns ratio N₁:N₂ = 6:1. Find the resistance R1′ seen looking into the primary winding.
N1:N2 = 6:1RL = 5 Ω
R1′ = Ω
4.TransformersHard
A single-phase 100 kVA transformer has a core loss of 800 W. At rated load and a power factor of 0.8 lagging its efficiency is 98%. Find the full-load copper loss Pcu,fl in watts.
S = 100 kVAPcore = 800 Wpf = 0.8η = 98%
Pcu,fl = W
5.AC power & power factorMedium
Two loads are connected in parallel to a 400 V single-phase supply: a 22 kW load at a power factor of 0.8 lagging and a 9 kW load at a power factor of 0.8 leading. Find the total current I drawn from the supply.
V = 400 VP1 = 22 kW, pf1 = 0.8 laggingP2 = 9 kW, pf2 = 0.8 leading
I = A
6.AC power & power factorHard
A 120 V (rms), 50 Hz source has an internal impedance Zs = 5 + j6 Ω. The load impedance ZL can be chosen freely. Find the maximum real power Pmax that can be delivered to the load.
Vs = 120 V (rms)f = 50 HzZs = 5 + j6 Ω
Pmax = W
7.AC impedance & phasorsMedium
A series RLC circuit with C = 10 µF must resonate at 2000 Hz. Find the inductance L needed.
f0 = 2000 HzC = 10 µF
L = mH
8.AC impedance & phasorsHard
A series RLC circuit is connected to a 10 V (rms), 500 Hz supply. Find the rms voltage VC across the capacitor.
V = 10 V (rms)f = 500 HzR = 15 ΩL = 20 mHC = 22 µF
VC = V
9.DC motorsMedium
A DC motor (k = 0.75 V·s/rad, Ra = 1.2 Ω) runs from 120 V. At full load it draws 5 A. Neglecting the no-load current, find its speed regulation SR = (n₀ − nFL)/nFL in percent.
V = 120 Vk = 0.75 V·s/radRa = 1.2 ΩIFL = 5 A
SR = %
10.DC motorsHard
A separately excited DC motor (k = 0.25 V·s/rad at full field, Ra = 1.2 Ω, V = 24 V) drives a constant load torque of 0.5 N·m. The field flux is reduced to 80 % of its full value. Find the new speed n.
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Phase voltage
Vph = 480/√3 = 277.1 V
Phase current
|Z| = √(24² + 18²) = 30 Ω
Iph = 277.1/30 = 9.238 A
Total real power
Only the resistive part of each impedance absorbs real power.
P = 3·Iph²·R = 3·9.238²·24 = 6.144 kW
Answer
P = 6.144 kW
Check: cos φ = R/|Z| = 0.8, and √3·VL·IL·cos φ gives the same power.
2.Three-phase power
Answer: QC = 204.3 kvar
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 250·tan(acos 0.7) = 250·1.02 = 255.1 kvar
Q2 = 250·tan(acos 0.98) = 250·0.2031 = 50.76 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 204.3 kvar
Answer
QC = 204.3 kvar
3.Transformers
Answer: R1′ = 180 Ω
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Referred resistance
The voltage goes up by a and the current down by a, so the ratio V/I goes up by a².
R1′ = a²·RL = 6²·5 = 180 Ω
Answer
R1′ = 180 Ω
4.Transformers
Answer: Pcu,fl = 832.7 W
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.
Output and input power
Pout = 100·0.8 = 80 kW
Pin = 80000/0.98 = 81633 W
Total and copper losses
Ploss = 81633 − 80000 = 1633 W
Pcu,fl = 1633 − 800 = 832.7 W
Answer
Pcu,fl = 832.7 W
5.AC power & power factor
Answer: I = 81.24 A
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power of each load
A lagging load takes reactive power (Q > 0); a leading load supplies it (Q < 0).
Q1 = 22·tan(arccos 0.8) = 16.5 kvar
Q2 = −9·tan(arccos 0.8) = −6.75 kvar
Totals
P = 22 + 9 = 31 kW
Q = 16.5 + (−6.75) = 9.75 kvar
S = √(31² + 9.75²) = 32.5 kVA
Total current
I = S/V = 32497/400 = 81.24 A
Answer
I = 81.24 A
6.AC power & power factor
Answer: Pmax = 720 W
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Conjugate match
The load reactance cancels the source reactance, and the load resistance equals the source resistance.
ZL = Zs* = 5 − j6 Ω
Maximum power
I = Vs/(2Rs) = 120/10 = 12 A
Pmax = I²·RL = Vs²/(4Rs) = 120²/(4·5) = 720 W
Answer
Pmax = 720 W
7.AC impedance & phasors
Answer: L = 0.6333 mH
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance condition
At resonance the inductive and capacitive reactances cancel: ωL = 1/(ωC).
ω₀ = 2π·2000 = 12566 rad/s
L = 1/(ω₀²·C) = 1/(12566²·10·10⁻⁶) = 0.6333 mH
Answer
L = 0.6333 mH
8.AC impedance & phasors
Answer: VC = 2.857 V
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
ω = 2πf = 2π·500 = 3142 rad/s
XL = ωL = 3142·0.02 = 62.83 Ω
XC = 1/(ωC) = 1/(3142·22·10⁻⁶) = 14.47 Ω
Impedance
In series the impedances add as complex numbers: Z = R + j(XL − XC).
The same current flows through every element of a series circuit.
I = V/|Z| = 10/50.64 = 0.1975 A
Voltage across the capacitor
VC = I·XC = 0.1975·14.47 = 2.857 V
Answer
VC = 2.857 V
9.DC motors
Answer: SR = 5.263 %
DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.
No-load and full-load speed
n₀ = 60·120/(2π·0.75) = 1528 rpm
nFL = 60·(120 − 5·1.2)/(2π·0.75) = 1451 rpm
Speed regulation
SR = (1528 − 1451)/1451·100 = 5.263 %
Answer
SR = 5.263 %
10.DC motors
Answer: n = 1003 rpm
DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.
Weakened motor constant
k₂ = 0.8·0.25 = 0.2 V·s/rad
New armature current
Ia = 0.5/0.2 = 2.5 A
New speed
ω = (24 − 2.5·1.2)/0.2 = 105 rad/s → n = 1003 rpm
Answer
n = 1003 rpm
Field weakening is how a DC drive runs above its base speed.