Power Systems and Electrical Machines: cram pack

Formula sheets, the key method steps for every topic and 10 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

Three-phase power

Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η

Transformers

Turns ratio
a = N1/N2 = V1/V2
Current ratio
I1/I2 = N2/N1 = 1/a
Rated current
I = S/V
Referred impedance
Z1′ = a²·ZL
Copper loss at part load
Pcu = x²·Pcu,fl
Efficiency
η = x·S·pf/(x·S·pf + Pcore + x²·Pcu,fl)
Maximum efficiency
x = √(Pcore/Pcu,fl)

AC power & power factor

Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)

AC impedance & phasors

Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z

Method

  1. Convert the frequency: ω = 2πf.
  2. Find each reactance: XL = ωL and XC = 1/(ωC).
  3. Add impedances like resistors, with Z = R + jX.
  4. Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.

DC motors

Armature circuit
V = E + IaRa
Back-EMF and torque
E = k·ω, T = k·Ia
Speed
ω = 2π·n/60, ω = (V − IaRa)/k
No-load speed and stall torque
ω0 = V/k, Tstall = k·V/Ra
Powers
Pin = V·Ia, Pdev = E·Ia = T·ω, Pout = Pdev − Prot
Starting
Istart = V/(Ra + Rst)
Speed regulation
SR = (n0 − nFL)/nFL
Maximum developed power
Pmax = V²/(4Ra)
Chopper drive
Va = D·Vdc

Method

  1. Draw the armature circuit: supply V, resistance Ra and the back-EMF E in series.
  2. Use V = E + Ia·Ra to link voltage, current and back-EMF.
  3. Use E = k·ω for speed and T = k·Ia for torque, with ω = 2π·n/60.
  4. For power and efficiency, start from V·Ia, subtract the copper loss Ia²·Ra and then the rotational losses.

2Practice problems

1.Three-phase powerMedium
ABCVL​ = 400 VZ = 15 + j20 Ωper phase

A balanced Δ-connected load with an impedance of 15 + j20 Ω per phase is connected to a balanced three-phase supply with a line-to-line voltage of 400 V. Find the total real power P absorbed by the load in kW.

VL = 400 VZ = 15 + j20 Ω per phase
P = kW
2.Three-phase powerHard
P = 200 kWφ1​S1​Q2​QC​ = ?

A balanced three-phase load takes 200 kW at a power factor of 0.75 lagging from a 400 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.98 lagging. The real power stays the same. Find the total reactive power QC the capacitor bank must supply, in kvar.

P = 200 kWpf1 = 0.75pf2 = 0.98VL = 400 Vf = 50 Hz
QC = kvar
3.TransformersMedium
10 ΩN1​N2​1440 Ω

An amplifier with an output resistance of 1440 Ω drives a 10 Ω loudspeaker through an ideal transformer. For maximum power transfer the loudspeaker must look like 1440 Ω from the amplifier. Find the turns ratio a = N₁/N₂.

Rs = 1440 ΩRL = 10 Ω
a =
4.TransformersHard
pf 0.95200 kVA, η = 98.2%

A single-phase 200 kVA transformer has a core loss of 600 W. At rated load and a power factor of 0.95 lagging its efficiency is 98.2%. Find the full-load copper loss Pcu,fl in watts.

S = 200 kVAPcore = 600 Wpf = 0.95η = 98.2%
Pcu,fl = W
5.AC power & power factorMedium
P = 37 kWQ = ?Sφ

A single-phase motor takes 37 kW at a power factor of 0.8 lagging from a 400 V supply. Find the reactive power Q it draws.

P = 37 kWpf = 0.8V = 400 V
Q = kvar
6.AC power & power factorHard
P = 5 kWQ1​S1​φ1​QC​

A single-phase load takes 5 kW at a power factor of 0.6 lagging from a 240 V, 50 Hz supply. A capacitor connected in parallel raises the power factor to 0.9. Find the reactive power QC the capacitor must supply.

P = 5 kWpf1 = 0.6pf2 = 0.9V = 240 Vf = 50 Hz
QC = kvar
7.AC impedance & phasorsMedium
12 V100 HzR = 80 ΩL = 100 mHC = 100 µFI

A series RLC circuit is connected to a 12 V (rms), 100 Hz supply. Find the real power P taken from the supply.

V = 12 V (rms)f = 100 HzR = 80 ΩL = 100 mHC = 100 µF
P = W
8.AC impedance & phasorsHard
10 V500 HzR = 50 ΩL = 150 mHC = 47 µF+−VC​

A series RLC circuit is connected to a 10 V (rms), 500 Hz supply. Find the rms voltage VC across the capacitor.

V = 10 V (rms)f = 500 HzR = 50 ΩL = 150 mHC = 47 µF
VC = V
9.DC motorsMedium
+−48 VRa​ = 0.4 ΩIa​ = 8 AM+−EωT

A DC motor draws 8 A from a 48 V supply. Its armature resistance is 0.4 Ω and its rotational (friction, windage and iron) losses are 11 W. Find its efficiency η.

V = 48 VIa = 8 ARa = 0.4 ΩProt = 11 W
η = %
10.DC motorsHard
+−48 VRa​ = 0.5 ΩIa​: 10 → 6 AM+−En = ?T

A separately excited DC motor on 48 V (Ra = 0.5 Ω) runs at 1440 rpm with an armature current of 10 A. The load changes and the current becomes 6 A, with the field unchanged. Find the new speed n2.

V = 48 VRa = 0.5 Ωn1 = 1440 rpmIa1 = 10 AIa2 = 6 A
n2 = rpm

3Solutions

1.Three-phase power

Answer: P = 11.52 kW

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.

Phase voltage

Vph = VL = 400 V

Phase current

|Z| = √(15² + 20²) = 25 Ω
Iph = 400/25 = 16 A

Total real power

Only the resistive part of each impedance absorbs real power.

P = 3·Iph²·R = 3·16²·15 = 11.52 kW

Answer

P = 11.52 kW

Check: cos φ = R/|Z| = 0.6, and √3·VL·IL·cos φ gives the same power.

2.Three-phase power

Answer: QC = 135.8 kvar

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.

Reactive power before and after

The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.

Q1 = 200·tan(acos 0.75) = 200·0.8819 = 176.4 kvar
Q2 = 200·tan(acos 0.98) = 200·0.2031 = 40.61 kvar

Reactive power from the capacitors

QC = Q1 − Q2 = 135.8 kvar

Answer

QC = 135.8 kvar
3.Transformers

Answer: a = 12

Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.

Match the referred load

a²·10 = 1440
a = √(1440/10) = √144 = 12

Answer

a = 12
4.Transformers

Answer: Pcu,fl = 2883 W

Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.

Output and input power

Pout = 200·0.95 = 190 kW
Pin = 190000/0.982 = 193483 W

Total and copper losses

Ploss = 193483 − 190000 = 3483 W
Pcu,fl = 3483 − 600 = 2883 W

Answer

Pcu,fl = 2883 W
5.AC power & power factor

Answer: Q = 27.75 kvar

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Angle

φ = arccos(0.8) = 36.87°, tan φ = 0.75

Reactive power

Q = P·tan φ = 37·0.75 = 27.75 kvar

Answer

Q = 27.75 kvar
6.AC power & power factor

Answer: QC = 4.245 kvar

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Reactive power before and after

The real power P does not change; only the reactive power drawn from the supply does.

Q1 = P·tan φ1 = 5·tan(53.13°) = 6.667 kvar
Q2 = P·tan φ2 = 5·tan(25.84°) = 2.422 kvar
QC = Q1 − Q2 = 4.245 kvar

Answer

QC = 4.245 kvar
7.AC impedance & phasors

Answer: P = 1.339 W

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactances

XL = 62.83 Ω, XC = 15.92 Ω

Impedance

|Z| = √(80² + (46.92)²) = 92.74 Ω

Real power

Inductors and capacitors only store and return energy; the resistor absorbs all of the real power.

I = 12/92.74 = 0.1294 A
P = I²·R = 0.1294²·80 = 1.339 W

Answer

P = 1.339 W
8.AC impedance & phasors

Answer: VC = 0.145 V

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactances

ω = 2πf = 2π·500 = 3142 rad/s
XL = ωL = 3142·0.15 = 471.2 Ω
XC = 1/(ωC) = 1/(3142·47·10⁻⁶) = 6.773 Ω

Impedance

In series the impedances add as complex numbers: Z = R + j(XL − XC).

|Z| = √(R² + (XL − XC)²) = √(50² + (464.5)²) = 467.1 Ω

Current

The same current flows through every element of a series circuit.

I = V/|Z| = 10/467.1 = 0.02141 A

Voltage across the capacitor

VC = I·XC = 0.02141·6.773 = 0.145 V

Answer

VC = 0.145 V
9.DC motors

Answer: η = 90.47 %

DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.

Powers

Pin = 48·8 = 384 W
Pdev = 44.8·8 = 358.4 W
Pout = 358.4 − 11 = 347.4 W

Efficiency

η = 347.4/384·100 = 90.47 %

Answer

η = 90.47 %
10.DC motors

Answer: n2 = 1507 rpm

DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.

Back-EMF before and after

E1 = 48 − 10·0.5 = 43 V
E2 = 48 − 6·0.5 = 45 V

New speed

n2 = 1440·45/43 = 1507 rpm

Answer

n2 = 1507 rpm

ExamProblems · examproblems.com/courses/power-systems