In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Three-phase power
Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η
Transformers
Turns ratio
a = N1/N2 = V1/V2
Current ratio
I1/I2 = N2/N1 = 1/a
Rated current
I = S/V
Referred impedance
Z1′ = a²·ZL
Copper loss at part load
Pcu = x²·Pcu,fl
Efficiency
η = x·S·pf/(x·S·pf + Pcore + x²·Pcu,fl)
Maximum efficiency
x = √(Pcore/Pcu,fl)
AC power & power factor
Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)
AC impedance & phasors
Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z
Method
Convert the frequency: ω = 2πf.
Find each reactance: XL = ωL and XC = 1/(ωC).
Add impedances like resistors, with Z = R + jX.
Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.
DC motors
Armature circuit
V = E + IaRa
Back-EMF and torque
E = k·ω, T = k·Ia
Speed
ω = 2π·n/60, ω = (V − IaRa)/k
No-load speed and stall torque
ω0 = V/k, Tstall = k·V/Ra
Powers
Pin = V·Ia, Pdev = E·Ia = T·ω, Pout = Pdev − Prot
Starting
Istart = V/(Ra + Rst)
Speed regulation
SR = (n0 − nFL)/nFL
Maximum developed power
Pmax = V²/(4Ra)
Chopper drive
Va = D·Vdc
Method
Draw the armature circuit: supply V, resistance Ra and the back-EMF E in series.
Use V = E + Ia·Ra to link voltage, current and back-EMF.
Use E = k·ω for speed and T = k·Ia for torque, with ω = 2π·n/60.
For power and efficiency, start from V·Ia, subtract the copper loss Ia²·Ra and then the rotational losses.
2Practice problems
1.Three-phase powerMedium
A balanced Δ-connected load with an impedance of 20 + j15 Ω per phase is connected to a balanced three-phase supply with a line-to-line voltage of 415 V. Find the total real power P absorbed by the load in kW.
VL = 415 VZ = 20 + j15 Ω per phase
P = kW
2.Three-phase powerHard
A balanced three-phase load takes 80 kW at a power factor of 0.72 lagging from a 400 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.98 lagging. The real power stays the same. The capacitors are connected in Y. Find the capacitance Cph of each capacitor in µF.
P = 80 kWpf1 = 0.72pf2 = 0.98VL = 400 Vf = 50 Hz
Cph = µF
3.TransformersMedium
An ideal transformer with a turns ratio N₁:N₂ = 2:1 has 460 V applied to its primary winding. A 30 Ω resistor is connected across the secondary winding. Find the primary current I1.
N1:N2 = 2:1V1 = 460 VRL = 30 Ω
I1 = A
4.TransformersHard
A single-phase 50 kVA transformer has a core loss of 400 W and a copper loss of 600 W at rated load. It supplies 50% of its rated kVA at a power factor of 0.95 lagging. Find the total losses Ploss in watts at this load.
An inductive load takes 15.5 A and 1674 W from a 120 V (rms) single-phase supply. Model it as a resistance R in series with a reactance X. Find X.
V = 120 VI = 15.5 AP = 1674 W
X = Ω
6.AC power & power factorHard
A single-phase load takes 25 kW at a power factor of 0.75 lagging from a 230 V, 50 Hz supply. A capacitor connected in parallel raises the power factor to 0.9. Find the reactive power QC the capacitor must supply.
P = 25 kWpf1 = 0.75pf2 = 0.9V = 230 Vf = 50 Hz
QC = kvar
7.AC impedance & phasorsMedium
A series RLC circuit with L = 50 mH must resonate at 2000 Hz. Find the capacitance C needed.
f0 = 2000 HzL = 50 mH
C = µF
8.AC impedance & phasorsHard
A series RLC circuit is connected to a 100 V (rms), 200 Hz supply. Find the resonant frequency f0 of the circuit.
V = 100 V (rms)f = 200 HzR = 10 ΩL = 100 mHC = 100 µF
f0 = Hz
9.DC motorsMedium
A DC motor with k = 0.25 N·m/A and Ra = 1.5 Ω is connected to 24 V. Find its stall torque Tstall, the torque at zero speed.
V = 24 Vk = 0.25 N·m/ARa = 1.5 Ω
Tstall = N·m
10.DC motorsHard
A DC motor with k = 0.15 V·s/rad and Ra = 1.5 Ω must drive a load of 0.3 N·m at 800 rpm. Find the armature voltage V it needs.
k = 0.15 V·s/radRa = 1.5 ΩT = 0.3 N·mn = 800 rpm
V = V
3Solutions
1.Three-phase power
Answer: P = 16.53 kW
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Phase voltage
Vph = VL = 415 V
Phase current
|Z| = √(20² + 15²) = 25 Ω
Iph = 415/25 = 16.6 A
Total real power
Only the resistive part of each impedance absorbs real power.
P = 3·Iph²·R = 3·16.6²·20 = 16.53 kW
Answer
P = 16.53 kW
Check: cos φ = R/|Z| = 0.8, and √3·VL·IL·cos φ gives the same power.
2.Three-phase power
Answer: Cph = 1211 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 80·tan(acos 0.72) = 80·0.9639 = 77.11 kvar
Q2 = 80·tan(acos 0.98) = 80·0.2031 = 16.24 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 60.86 kvar
Capacitance per phase
In a Y bank each capacitor is connected between a line and the star point.
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Secondary voltage and current
V2 = 460/2 = 230 V
I2 = 230/30 = 7.667 A
Primary current
An ideal transformer has no losses: V₁·I₁ = V₂·I₂.
I1 = I2/2 = 3.833 A
Answer
I1 = 3.833 A
Check: the load seen from the primary is a²·RL = 120 Ω, and 460/120 gives the same current.
4.Transformers
Answer: Ploss = 550 W
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.
Copper loss at this load
Pcu = x²·Pcu,fl = 0.25·600 = 150 W
Total losses
The core loss is the same at any load.
Ploss = 400 + 150 = 550 W
Answer
Ploss = 550 W
The efficiency at this load is η = 97.74%.
5.AC power & power factor
Answer: X = 3.375 Ω
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Resistance from the real power
R = P/I² = 1674/15.5² = 6.968 Ω
Reactance from the impedance
|Z| = V/I = 120/15.5 = 7.742 Ω
X = √(|Z|² − R²) = √(7.742² − 6.968²) = 3.375 Ω
Answer
X = 3.375 Ω
6.AC power & power factor
Answer: QC = 9.94 kvar
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = P·tan φ1 = 25·tan(41.41°) = 22.05 kvar
Q2 = P·tan φ2 = 25·tan(25.84°) = 12.11 kvar
QC = Q1 − Q2 = 9.94 kvar
Answer
QC = 9.94 kvar
7.AC impedance & phasors
Answer: C = 0.1267 µF
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance condition
At resonance the inductive and capacitive reactances cancel: ωL = 1/(ωC).
ω₀ = 2π·2000 = 12566 rad/s
C = 1/(ω₀²·L) = 1/(12566²·0.05) = 0.1267 µF
Answer
C = 0.1267 µF
8.AC impedance & phasors
Answer: f0 = 50.33 Hz
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance
At resonance the inductive and capacitive reactances cancel: ωL = 1/(ωC). The supply frequency does not matter.
DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.
Stall current
Ia = V/Ra = 24/1.5 = 16 A
Stall torque
Tstall = 0.25·16 = 4 N·m
Answer
Tstall = 4 N·m
10.DC motors
Answer: V = 15.57 V
DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.