Power Systems and Electrical Machines: cram pack

Formula sheets, the key method steps for every topic and 10 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

Three-phase power

Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η

Transformers

Turns ratio
a = N1/N2 = V1/V2
Current ratio
I1/I2 = N2/N1 = 1/a
Rated current
I = S/V
Referred impedance
Z1′ = a²·ZL
Copper loss at part load
Pcu = x²·Pcu,fl
Efficiency
η = x·S·pf/(x·S·pf + Pcore + x²·Pcu,fl)
Maximum efficiency
x = √(Pcore/Pcu,fl)

AC power & power factor

Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)

AC impedance & phasors

Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z

Method

  1. Convert the frequency: ω = 2πf.
  2. Find each reactance: XL = ωL and XC = 1/(ωC).
  3. Add impedances like resistors, with Z = R + jX.
  4. Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.

DC motors

Armature circuit
V = E + IaRa
Back-EMF and torque
E = k·ω, T = k·Ia
Speed
ω = 2π·n/60, ω = (V − IaRa)/k
No-load speed and stall torque
ω0 = V/k, Tstall = k·V/Ra
Powers
Pin = V·Ia, Pdev = E·Ia = T·ω, Pout = Pdev − Prot
Starting
Istart = V/(Ra + Rst)
Speed regulation
SR = (n0 − nFL)/nFL
Maximum developed power
Pmax = V²/(4Ra)
Chopper drive
Va = D·Vdc

Method

  1. Draw the armature circuit: supply V, resistance Ra and the back-EMF E in series.
  2. Use V = E + Ia·Ra to link voltage, current and back-EMF.
  3. Use E = k·ω for speed and T = k·Ia for torque, with ω = 2π·n/60.
  4. For power and efficiency, start from V·Ia, subtract the copper loss Ia²·Ra and then the rotational losses.

2Practice problems

1.Three-phase powerMedium
ABCVL​ = 400 VIL​ = ?M45 kW, η = 90%cos φ = 0.88

A three-phase induction motor delivers 45 kW of mechanical output power at full load. At this load its efficiency is 90% and its power factor is 0.88 lagging. The supply has a line-to-line voltage of 400 V. Find the line current IL.

Pout = 45 kWη = 90%cos φ = 0.88VL = 400 V
IL = A
2.Three-phase powerHard
P = 60 kWφ1​S1​Q2​QC​

A balanced three-phase load takes 60 kW at a power factor of 0.7 lagging from a 415 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.9 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.

P = 60 kWpf1 = 0.7pf2 = 0.9VL = 415 Vf = 50 Hz
Cph = µF
3.TransformersMedium
RL​ = 12 Ω21240 VV2​I1​ = ?I2​

An ideal transformer with a turns ratio N₁:N₂ = 2:1 has 240 V applied to its primary winding. A 12 Ω resistor is connected across the secondary winding. Find the primary current I1.

N1:N2 = 2:1V1 = 240 VRL = 12 Ω
I1 = A
4.TransformersHard
75 kVA

A single-phase 75 kVA transformer has a core loss of 450 W and a copper loss of 1800 W at rated load. At what load Sη,max, in kVA, is its efficiency highest?

S = 75 kVAPcore = 450 WPcu,fl = 1800 W
Sη,max = kVA
5.AC power & power factorMedium
P = 24 kWQ = ?Sφ

A single-phase motor takes 24 kW at a power factor of 0.8 lagging from a 230 V supply. Find the reactive power Q it draws.

P = 24 kWpf = 0.8V = 230 V
Q = kvar
6.AC power & power factorHard
P = 25 kWQ1​S1​φ1​QC​

A single-phase load takes 25 kW at a power factor of 0.75 lagging from a 400 V, 60 Hz supply. A capacitor connected in parallel raises the power factor to 0.92. Find the capacitance C needed.

P = 25 kWpf1 = 0.75pf2 = 0.92V = 400 Vf = 60 Hz
C = µF
7.AC impedance & phasorsMedium
50 V500 HzR = 80 ΩL = 200 mHC = 10 µF

A series RLC circuit is connected to a 50 V (rms), 500 Hz supply. Find the phase angle φ of the impedance, in degrees (positive when the current lags the voltage).

V = 50 V (rms)f = 500 HzR = 80 ΩL = 200 mHC = 10 µF
φ = °
8.AC impedance & phasorsHard
120 V500 HzR = 50 ΩL = 100 mHC = 47 µFI

A series RLC circuit is connected to a 120 V (rms), 500 Hz supply. Find the rms current I.

V = 120 V (rms)f = 500 HzR = 50 ΩL = 100 mHC = 47 µF
I = A
9.DC motorsMedium
T (N·m)n (rpm)n0​ = ?

A DC motor with k = 0.3 V·s/rad runs from 110 V. Neglecting all losses at no load, find its no-load speed n0 in rpm.

V = 110 Vk = 0.3 V·s/rad
n0 = rpm
10.DC motorsHard
+−48 VRs​ = ?Ra​ = 1.5 ΩM+−En = 400 rpmT = 1.5 N·m

A DC motor (k = 0.75 V·s/rad, Ra = 1.5 Ω) on a fixed 48 V supply drives a load of 1.5 N·m. Find the series resistance Rs that slows it down to 400 rpm.

V = 48 Vk = 0.75 V·s/radRa = 1.5 ΩT = 1.5 N·mn = 400 rpm
Rs = Ω

3Solutions

1.Three-phase power

Answer: IL = 82.01 A

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.

Electrical input power

Pin = Pout/η = 45/0.9 = 50 kW

Line current

IL = Pin/(√3·VL·cos φ) = 50000/(√3·400·0.88) = 82.01 A

Answer

IL = 82.01 A
2.Three-phase power

Answer: Cph = 198.1 µF

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.

Reactive power before and after

The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.

Q1 = 60·tan(acos 0.7) = 60·1.02 = 61.21 kvar
Q2 = 60·tan(acos 0.9) = 60·0.4843 = 29.06 kvar

Reactive power from the capacitors

QC = Q1 − Q2 = 32.15 kvar

Capacitance per phase

In a Δ bank each capacitor is connected between two lines.

V = 415 V, ω = 2π·50 = 314.2 rad/s
Cph = (QC/3)/(ω·V²) = 10718/(314.2·415²) = 198.1 µF

Answer

Cph = 198.1 µF
3.Transformers

Answer: I1 = 5 A

Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.

Secondary voltage and current

V2 = 240/2 = 120 V
I2 = 120/12 = 10 A

Primary current

An ideal transformer has no losses: V₁·I₁ = V₂·I₂.

I1 = I2/2 = 5 A

Answer

I1 = 5 A

Check: the load seen from the primary is a²·RL = 48 Ω, and 240/48 gives the same current.

4.Transformers

Answer: Sη,max = 37.5 kVA

Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.

Copper loss equals core loss

x²·1800 = 450 → x = √(450/1800) = 0.5

Load at maximum efficiency

Sη,max = x·S = 0.5·75 = 37.5 kVA

Answer

Sη,max = 37.5 kVA
5.AC power & power factor

Answer: Q = 18 kvar

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Angle

φ = arccos(0.8) = 36.87°, tan φ = 0.75

Reactive power

Q = P·tan φ = 24·0.75 = 18 kvar

Answer

Q = 18 kvar
6.AC power & power factor

Answer: C = 189 µF

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Reactive power before and after

The real power P does not change; only the reactive power drawn from the supply does.

Q1 = P·tan φ1 = 25·tan(41.41°) = 22.05 kvar
Q2 = P·tan φ2 = 25·tan(23.07°) = 10.65 kvar
QC = Q1 − Q2 = 11.4 kvar

Capacitance

A capacitor across the supply delivers Q = V²·ωC.

C = QC/(2πf·V²) = 11398/(2π·60·400²) = 189 µF

Answer

C = 189 µF
7.AC impedance & phasors

Answer: φ = 82.36 °

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactances

ω = 2πf = 2π·500 = 3142 rad/s
XL = ωL = 3142·0.2 = 628.3 Ω
XC = 1/(ωC) = 1/(3142·10·10⁻⁶) = 31.83 Ω

Impedance

In series the impedances add as complex numbers: Z = R + j(XL − XC).

|Z| = √(R² + (XL − XC)²) = √(80² + (596.5)²) = 601.8 Ω

Phase angle

φ = arctan((XL − XC)/R) = arctan(596.5/80) = 82.36°

Answer

φ = 82.36°
8.AC impedance & phasors

Answer: I = 0.3853 A

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactances

ω = 2πf = 2π·500 = 3142 rad/s
XL = ωL = 3142·0.1 = 314.2 Ω
XC = 1/(ωC) = 1/(3142·47·10⁻⁶) = 6.773 Ω

Impedance

In series the impedances add as complex numbers: Z = R + j(XL − XC).

|Z| = √(R² + (XL − XC)²) = √(50² + (307.4)²) = 311.4 Ω

Current

The same current flows through every element of a series circuit.

I = V/|Z| = 120/311.4 = 0.3853 A

Answer

I = 0.3853 A
9.DC motors

Answer: n0 = 3501 rpm

DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.

No-load speed

ω₀ = V/k = 110/0.3 = 366.7 rad/s
n0 = 60·366.7/(2π) = 3501 rpm

Answer

n0 = 3501 rpm
10.DC motors

Answer: Rs = 6.792 Ω

DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.

Current and back-EMF

Ia = 1.5/0.75 = 2 A
E = 0.75·41.89 = 31.42 V

Series resistance

Ra + Rs = (48 − 31.42)/2 = 8.292 Ω
Rs = 6.792 Ω

Answer

Rs = 6.792 Ω

The resistor wastes 27.17 W; a chopper controls the speed with far less loss.

ExamProblems · examproblems.com/courses/power-systems