Power Systems and Electrical Machines: cram pack

Formula sheets, the key method steps for every topic and 10 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

Three-phase power

Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η

Transformers

Turns ratio
a = N1/N2 = V1/V2
Current ratio
I1/I2 = N2/N1 = 1/a
Rated current
I = S/V
Referred impedance
Z1′ = a²·ZL
Copper loss at part load
Pcu = x²·Pcu,fl
Efficiency
η = x·S·pf/(x·S·pf + Pcore + x²·Pcu,fl)
Maximum efficiency
x = √(Pcore/Pcu,fl)

AC power & power factor

Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)

AC impedance & phasors

Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z

Method

  1. Convert the frequency: ω = 2πf.
  2. Find each reactance: XL = ωL and XC = 1/(ωC).
  3. Add impedances like resistors, with Z = R + jX.
  4. Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.

DC motors

Armature circuit
V = E + IaRa
Back-EMF and torque
E = k·ω, T = k·Ia
Speed
ω = 2π·n/60, ω = (V − IaRa)/k
No-load speed and stall torque
ω0 = V/k, Tstall = k·V/Ra
Powers
Pin = V·Ia, Pdev = E·Ia = T·ω, Pout = Pdev − Prot
Starting
Istart = V/(Ra + Rst)
Speed regulation
SR = (n0 − nFL)/nFL
Maximum developed power
Pmax = V²/(4Ra)
Chopper drive
Va = D·Vdc

Method

  1. Draw the armature circuit: supply V, resistance Ra and the back-EMF E in series.
  2. Use V = E + Ia·Ra to link voltage, current and back-EMF.
  3. Use E = k·ω for speed and T = k·Ia for torque, with ω = 2π·n/60.
  4. For power and efficiency, start from V·Ia, subtract the copper loss Ia²·Ra and then the rotational losses.

2Practice problems

1.Three-phase powerMedium
ABCVL​ = 415 VZ = 12 + j5 Ωper phase

A balanced Δ-connected load with an impedance of 12 + j5 Ω per phase is connected to a balanced three-phase supply with a line-to-line voltage of 415 V. Find the total real power P absorbed by the load in kW.

VL = 415 VZ = 12 + j5 Ω per phase
P = kW
2.Three-phase powerHard
P = 60 kWφ1​S1​Q2​QC​

A balanced three-phase load takes 60 kW at a power factor of 0.65 lagging from a 480 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.9 lagging. The real power stays the same. The capacitors are connected in Y. Find the capacitance Cph of each capacitor in µF.

P = 60 kWpf1 = 0.65pf2 = 0.9VL = 480 Vf = 50 Hz
Cph = µF
3.TransformersMedium
RL​ = 20 Ω41920 VV2​I1​ = ?I2​

An ideal transformer with a turns ratio N₁:N₂ = 4:1 has 920 V applied to its primary winding. A 20 Ω resistor is connected across the secondary winding. Find the primary current I1.

N1:N2 = 4:1V1 = 920 VRL = 20 Ω
I1 = A
4.TransformersHard
pf 0.9100 kVA, η = 96%

A single-phase 100 kVA transformer has a core loss of 800 W. At rated load and a power factor of 0.9 lagging its efficiency is 96%. Find the full-load copper loss Pcu,fl in watts.

S = 100 kVAPcore = 800 Wpf = 0.9η = 96%
Pcu,fl = W
5.AC power & power factorMedium
P = 13 kWQ = ?Sφ

A single-phase motor takes 13 kW at a power factor of 0.8 lagging from a 240 V supply. Find the reactive power Q it draws.

P = 13 kWpf = 0.8V = 240 V
Q = kvar
6.AC power & power factorHard
230 V50 Hzload5 kW, 0.7C68 µFI

A single-phase load takes 5 kW at a power factor of 0.7 lagging from a 230 V, 50 Hz supply. A 68 µF capacitor is connected in parallel with the load. Find the new power factor cos φ seen by the supply.

P = 5 kWpf1 = 0.7V = 230 Vf = 50 HzC = 68 µF
cos φ =
7.AC impedance & phasorsMedium
100 V100 HzR = 20 ΩL = 150 mHC = 100 µF

A series RLC circuit is connected to a 100 V (rms), 100 Hz supply. Find the phase angle φ of the impedance, in degrees (positive when the current lags the voltage).

V = 100 V (rms)f = 100 HzR = 20 ΩL = 150 mHC = 100 µF
φ = °
8.AC impedance & phasorsHard
12 V100 HzR1​ = 20 ΩR2​ = 20 ΩC = 100 µF

A resistor R1 is connected in series with a parallel combination of R2 and a capacitor C, across a 12 V (rms), 100 Hz supply. Find the magnitude of the impedance |Z|.

V = 12 V (rms)f = 100 HzR1 = 20 ΩR2 = 20 ΩC = 100 µF
|Z| = Ω
9.DC motorsMedium
T (N·m)n (rpm)n0​ = ?

A DC motor with k = 1 V·s/rad runs from 240 V. Neglecting all losses at no load, find its no-load speed n0 in rpm.

V = 240 Vk = 1 V·s/rad
n0 = rpm
10.DC motorsHard
+−220 VRst​ = ?Ra​ = 0.8 Ω20 AM+−E = 0n = 0T

A 220 V DC motor has an armature resistance of 0.8 Ω. Find the series starting resistance Rst that limits the starting current to 20 A.

V = 220 VRa = 0.8 ΩImax = 20 A
Rst = Ω

3Solutions

1.Three-phase power

Answer: P = 36.69 kW

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.

Phase voltage

Vph = VL = 415 V

Phase current

|Z| = √(12² + 5²) = 13 Ω
Iph = 415/13 = 31.92 A

Total real power

Only the resistive part of each impedance absorbs real power.

P = 3·Iph²·R = 3·31.92²·12 = 36.69 kW

Answer

P = 36.69 kW

Check: cos φ = R/|Z| = 0.9231, and √3·VL·IL·cos φ gives the same power.

2.Three-phase power

Answer: Cph = 567.7 µF

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.

Reactive power before and after

The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.

Q1 = 60·tan(acos 0.65) = 60·1.169 = 70.15 kvar
Q2 = 60·tan(acos 0.9) = 60·0.4843 = 29.06 kvar

Reactive power from the capacitors

QC = Q1 − Q2 = 41.09 kvar

Capacitance per phase

In a Y bank each capacitor is connected between a line and the star point.

V = 480/√3 = 277.1 V, ω = 2π·50 = 314.2 rad/s
Cph = (QC/3)/(ω·V²) = 13696/(314.2·277.1²) = 567.7 µF

Answer

Cph = 567.7 µF
3.Transformers

Answer: I1 = 2.875 A

Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.

Secondary voltage and current

V2 = 920/4 = 230 V
I2 = 230/20 = 11.5 A

Primary current

An ideal transformer has no losses: V₁·I₁ = V₂·I₂.

I1 = I2/4 = 2.875 A

Answer

I1 = 2.875 A

Check: the load seen from the primary is a²·RL = 320 Ω, and 920/320 gives the same current.

4.Transformers

Answer: Pcu,fl = 2950 W

Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.

Output and input power

Pout = 100·0.9 = 90 kW
Pin = 90000/0.96 = 93750 W

Total and copper losses

Ploss = 93750 − 90000 = 3750 W
Pcu,fl = 3750 − 800 = 2950 W

Answer

Pcu,fl = 2950 W
5.AC power & power factor

Answer: Q = 9.75 kvar

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Angle

φ = arccos(0.8) = 36.87°, tan φ = 0.75

Reactive power

Q = P·tan φ = 13·0.75 = 9.75 kvar

Answer

Q = 9.75 kvar
6.AC power & power factor

Answer: cos φ = 0.7831

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Reactive power before and after

The real power P does not change; only the reactive power drawn from the supply does.

Q1 = 5·tan(arccos 0.7) = 5.101 kvar
QC = V²·2πf·C = 230²·2π·50·68·10⁻⁶ = 1130 var = 1.13 kvar
Q2 = 5.101 − 1.13 = 3.971 kvar

New apparent power

S2 = √(5² + 3.971²) = 6.385 kVA

New power factor

cos φ = P/S2 = 5/6.385 = 0.7831

Answer

cos φ = 0.7831
7.AC impedance & phasors

Answer: φ = 75.68 °

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactances

ω = 2πf = 2π·100 = 628.3 rad/s
XL = ωL = 628.3·0.15 = 94.25 Ω
XC = 1/(ωC) = 1/(628.3·100·10⁻⁶) = 15.92 Ω

Impedance

In series the impedances add as complex numbers: Z = R + j(XL − XC).

|Z| = √(R² + (XL − XC)²) = √(20² + (78.33)²) = 80.85 Ω

Phase angle

φ = arctan((XL − XC)/R) = arctan(78.33/20) = 75.68°

Answer

φ = 75.68°
8.AC impedance & phasors

Answer: |Z| = 29.42 Ω

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactance

XC = 1/(2π·100·100·10⁻⁶) = 15.92 Ω

Parallel combination

Multiply top and bottom by the complex conjugate to split Zp into real and imaginary parts.

Zp = R₂·(−jXC)/(R₂ − jXC) = (R₂·XC² − jR₂²·XC)/(R₂² + XC²)
Zp = 7.755 − j9.745 Ω

Total impedance

Z = 20 + 7.755 − j9.745 = 27.75 − j9.745 Ω
|Z| = √(27.75² + 9.745²) = 29.42 Ω

Answer

|Z| = 29.42 Ω
9.DC motors

Answer: n0 = 2292 rpm

DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.

No-load speed

ω₀ = V/k = 240/1 = 240 rad/s
n0 = 60·240/(2π) = 2292 rpm

Answer

n0 = 2292 rpm
10.DC motors

Answer: Rst = 10.2 Ω

DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.

Total resistance

Ra + Rst = 220/20 = 11 Ω

Starting resistor

Rst = 11 − 0.8 = 10.2 Ω

Answer

Rst = 10.2 Ω

The resistor is cut out step by step as the motor speeds up and the back-EMF grows.

ExamProblems · examproblems.com/courses/power-systems