Sketch both signals and note where each one is nonzero.
Flip h and slide it: for each output time, find the range where both signals overlap.
Multiply and add (discrete) or multiply and integrate (continuous) over that overlap only.
Check the result: the output starts at the sum of the start times, ends at the sum of the end times, and its area or sum is the product of the input areas or sums.
2Practice problems
1.Convolution & LTI systemsMedium
A system has the impulse response h(t) = e−5tu(t). The input is a step x(t) = 5·u(t). Find the output y(0.2) at t = 0.2 s.
h(t) = e−5tu(t)x(t) = 5·u(t)t = 0.2 s
y(0.2) =
2.Convolution & LTI systemsHard
The input x(t) = 10·cos(1.5t) is applied to a system with h(t) = 2·e−2tu(t). Find the phase φ of the steady-state output relative to the input, in degrees.
h(t) = 2e−2tu(t)x(t) = 10cos(1.5t)
φ = °
3.Laplace transformsMedium
Find f(t) for F(s) = 15/(s(s + 2)(s + 4)) by partial fractions, and evaluate f(0.2).
F(s) = 15/(s(s + 2)(s + 4))t = 0.2 s
f(0.2) =
4.Laplace transformsHard
Solve y″ + 5y′ + 6y = 0 with y(0) = 10 and y′(0) = 7 using the Laplace transform, and find y(0.3).
y″ + 5y′ + 6y = 0y(0) = 10y′(0) = 7t = 0.3 s
y(0.3) =
5.Step responseMedium
A system has the transfer function G(s) = 92/(s² + 9s + 46) and receives a unit step input. Find the percent overshoot %OS of the step response.
G(s) = 92/(s² + 9s + 46)
%OS = %
6.Step responseHard
A series RLC circuit with R = 32 Ω, L = 100 mH and C = 100 µF is connected to a 12 V step at t = 0. The capacitor is uncharged and no current flows before the step. Find the undamped natural frequency ωn in rad/s.
R = 32 ΩL = 100 mHC = 100 µFV = 12 V
ωn = rad/s
7.Bode plots & marginsMedium
Find the exact magnitude |G(jω)| of G(s) = 2160/((s + 15)(s + 18)) at ω = 2 rad/s, in dB.
G(s) = 2160/((s + 15)(s + 18))ω = 2 rad/s
|G(jω)| = dB
8.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 1144/(s(s + 8)(s + 10)). Find the gain margin GM in dB.
L(s) = 1144/(s(s + 8)(s + 10))
GM = dB
3Solutions
1.Convolution & LTI systems
Answer: y(0.2) = 0.6321
Continuous convolution: y(t) = ∫ x(τ)·h(t − τ) dτ. Flip h, slide it to position t and integrate the product of the overlapping parts. For causal signals the integral runs from 0 to t. Useful results: the area of y is the area of x times the area of h; if x lasts from t₁ to t₂ and h from t₃ to t₄, y lasts from t₁ + t₃ to t₂ + t₄. For h(t) = e−atu(t) and a step of height A, y(t) = (A/a)(1 − e−at).
Convolution with a step
y(t) = 5·∫₀ᵗ e−5τ dτ = (5/5)·(1 − e−5t)
Evaluate
y(0.2) = 1·(1 − e−1) = 0.6321
Answer
y(0.2) = 0.6321
2.Convolution & LTI systems
Answer: φ = −36.87 °
Impulse response and Fourier series: the impulse response h(t) describes an LTI system completely: for y′ + a·y = b·x it is h(t) = b·e−atu(t), and for y[n] = a·y[n − 1] + b·x[n] it is h[n] = b·aⁿu[n]. A sinusoid cos ωt passes through with gain |H(jω)| and phase ∠H(jω), where H is the Fourier transform of h. A periodic signal is a sum of harmonics at k/T: a square wave of ±A has only odd harmonics with amplitudes 4A/(kπ), a triangle wave of peak A has 8A/(π²k²), and a pulse train of height A and duty cycle D has the mean A·D and the harmonics (2A/(kπ))·|sin(kπD)|.
Frequency response
H(jω) = 2/(2 + jω)
Phase at the input frequency
φ = −atan(1.5/2) = −36.87°
Answer
φ = −36.87°
3.Laplace transforms
Answer: f(0.2) = 0.2038
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transform the equation
s²Y − 10s − 7 + 5(sY − 10) + 6Y = 0
Y(s) = (10s + 57)/((s + 2)(s + 3))
Partial fractions
A = 37/1 = 37
B = 27/(−1) = −27
Result
y(t) = 37·e−2t − 27·e−3t
y(0.3) = 9.329
Answer
y(0.3) = 9.329
Check: y(0) = A + B = 10.
5.Step response
Answer: %OS = 6.167 %
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 46 → ωₙ = 6.782 rad/s
2ζωₙ = 9 → ζ = 9/(2·6.782) = 0.6635
Result
%OS = 100·e−ζπ/√(1−ζ²) = 100·e−2.786 = 6.167 %
Answer
%OS = 6.167 %
6.Step response
Answer: ωn = 316.2 rad/s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Natural frequency and damping ratio
ωₙ = 1/√(LC) = 1/√(0.1·1 × 10⁻⁴) = 316.2 rad/s
ζ = (R/2)·√(C/L) = (32/2)·√(1 × 10⁻⁴/0.1) = 0.506
Result
ωₙ = 316.2 rad/s
Answer
ωn = 316.2 rad/s
7.Bode plots & margins
Answer: |G(jω)| = 17.93 dB
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.