Sketch both signals and note where each one is nonzero.
Flip h and slide it: for each output time, find the range where both signals overlap.
Multiply and add (discrete) or multiply and integrate (continuous) over that overlap only.
Check the result: the output starts at the sum of the start times, ends at the sum of the end times, and its area or sum is the product of the input areas or sums.
2Practice problems
1.Convolution & LTI systemsMedium
The pulse x(t) = 5 for 0 ≤ t < 4 s is convolved with h(t), a triangle that falls linearly from 2 at t = 0 to 0 at t = 1 s. Find the area Ay under y(t) = x(t) ∗ h(t).
x(t) = 5, 0 ≤ t < 4 sh(0) = 2, h(1) = 0
Ay =
2.Convolution & LTI systemsHard
A triangle wave rises and falls linearly between −3 and +3 with period T = 2 ms. Find the amplitude c1 of its Fourier component at 500 Hz.
±3T = 2 msf = 500 Hz
c1 =
3.Laplace transformsMedium
F(s) = (2s + 34)/(s² + 7s + 12). Its inverse transform has the form f(t) = A·e−3t + B·e−4t. Find the coefficient A by partial fractions.
F(s) = (2s + 34)/(s² + 7s + 12)
A =
4.Laplace transformsHard
A system obeys y″ + 11y′ + 30y = 90·u(t), with y(0) = 2 and y′(0) = 0. At t = 0 a step input u(t) = 10 is applied. Use the Laplace transform to find y(0.2).
A system has the transfer function G(s) = 71/(s² + 4s + 71) and receives a unit step input. The poles are s = σ ± jωd. Find the real part σ.
G(s) = 71/(s² + 4s + 71)
σ =
6.Step responseHard
A unity negative feedback loop has G(s) = 265/(s(s + 20)). Find the 2 % settling time ts of the closed-loop step response, using ts ≈ 4/(ζωₙ).
G(s) = 265/(s(s + 20))
ts = s
7.Bode plots & marginsMedium
The RC low-pass filter shown has R = 1 kΩ, C = 4.7 nF. A sinusoidal input of 340 kHz is applied. Find the gain |H| = |vout/vin| in dB.
R = 1 kΩC = 4.7 nFf = 340 kHz
|H| = dB
8.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 96/(s(s + 6)(s + 10)). Find the phase crossover frequency ω180, where ∠L(jω) = −180°.
L(s) = 96/(s(s + 6)(s + 10))
ω180 = rad/s
3Solutions
1.Convolution & LTI systems
Answer: Ay = 20
Continuous convolution: y(t) = ∫ x(τ)·h(t − τ) dτ. Flip h, slide it to position t and integrate the product of the overlapping parts. For causal signals the integral runs from 0 to t. Useful results: the area of y is the area of x times the area of h; if x lasts from t₁ to t₂ and h from t₃ to t₄, y lasts from t₁ + t₃ to t₂ + t₄. For h(t) = e−atu(t) and a step of height A, y(t) = (A/a)(1 − e−at).
Areas of the inputs
∫x dt = 5·4 = 20
∫h dt = ½·1·2 = 1
Area of the output
Ay = 20·1 = 20
Answer
Ay = 20
2.Convolution & LTI systems
Answer: c1 = 2.432
Impulse response and Fourier series: the impulse response h(t) describes an LTI system completely: for y′ + a·y = b·x it is h(t) = b·e−atu(t), and for y[n] = a·y[n − 1] + b·x[n] it is h[n] = b·aⁿu[n]. A sinusoid cos ωt passes through with gain |H(jω)| and phase ∠H(jω), where H is the Fourier transform of h. A periodic signal is a sum of harmonics at k/T: a square wave of ±A has only odd harmonics with amplitudes 4A/(kπ), a triangle wave of peak A has 8A/(π²k²), and a pulse train of height A and duty cycle D has the mean A·D and the harmonics (2A/(kπ))·|sin(kπD)|.
Harmonic number
f₀ = 1/T = 500 Hz → k = 1
Amplitude
c1 = 8·3/(π²·1²) = 2.432
Answer
c1 = 2.432
3.Laplace transforms
Answer: A = 28
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Factor the denominator
s² + 7s + 12 = (s + 3)(s + 4)
F(s) = A/(s + 3) + B/(s + 4)
Cover-up rule
Multiply by (s + 3) and set s = −3: the B-term vanishes.
A = (2s + 34)/(s + 4) |s = −3 = 28/1 = 28
Answer
A = 28
(B = −26, so f(t) = 28·e−3t − 26·e−4t)
4.Laplace transforms
Answer: y(0.2) = 10.36
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transform the equation
(s² + 11s + 30)·Y(s) = 2s + 22 + 900/s
Y(s) = (2s² + 22s + 900)/(s(s + 5)(s + 6))
Partial fractions
A = 900/(5·6) = 30
B = 840/((−5)·1) = −168
C = 840/((−6)·(−1)) = 140
Result
y(t) = 30 − 168·e−5t + 140·e−6t
y(0.2) = 10.36
Answer
y(0.2) = 10.36
Check: y(0) = A + B + C = 2.
5.Step response
Answer: σ = −2
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 71 → ωₙ = 8.426 rad/s
2ζωₙ = 4 → ζ = 4/(2·8.426) = 0.2374
Result
σ = −ζωₙ = −4/2 = −2
Answer
σ = −2
6.Step response
Answer: ts = 0.4 s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
For this loop ζωₙ = a/2 whatever K is: raising K adds overshoot but does not shorten the settling time.
7.Bode plots & margins
Answer: |H| = −20.08 dB
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Corner frequency
ωc = 1/(RC) = 1/(1000·4.7 × 10⁻⁹) = 212766 rad/s
fc = 33863 Hz → f/fc = 340000/33863 = 10.04
Gain
|H| = 1/√(1 + 10.04²) = 0.09911
20·log₁₀(0.09911) = −20.08 dB
Answer
|H| = −20.08 dB
8.Bode plots & margins
Answer: ω180 = 7.746 rad/s
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.