AC power & power factor worksheet with answers

Free printable AC power & power factor worksheet: 6 problems from easy to exam level, with an answer key. Print it or save it as a PDF.

For teachers: free to print, copy and use in class. Every new worksheet has new values and its own answer key. A link to ExamProblems on your course page is appreciated.

Name: ____________________   Date: ____________

1.Easy
240 VloadP = 3042 W19.5 A

A voltmeter, an ammeter and a wattmeter connected to a single-phase inductive load read 240 V, 19.5 A and 3042 W. Find the power factor cos φ of the load.

V = 240 VI = 19.5 AP = 3042 W
cos φ =
2.Easy
240 VloadP = 2184 W13 A

A voltmeter, an ammeter and a wattmeter connected to a single-phase inductive load read 240 V, 13 A and 2184 W. Find the power factor cos φ of the load.

V = 240 VI = 13 AP = 2184 W
cos φ =
3.Medium
120 VR + jXP = 324 W4.5 A

An inductive load takes 4.5 A and 324 W from a 120 V (rms) single-phase supply. Model it as a resistance R in series with a reactance X. Find R.

V = 120 VI = 4.5 AP = 324 W
R = Ω
4.Medium
120 VR + jXP = 1224 W12 A

An inductive load takes 12 A and 1224 W from a 120 V (rms) single-phase supply. Model it as a resistance R in series with a reactance X. Find X.

V = 120 VI = 12 AP = 1224 W
X = Ω
5.Hard
P = 5 kWQ1​S1​φ1​QC​

A single-phase load takes 5 kW at a power factor of 0.75 lagging from a 230 V, 50 Hz supply. A capacitor connected in parallel raises the power factor to 0.92. Find the new line current Inew.

P = 5 kWpf1 = 0.75pf2 = 0.92V = 230 Vf = 50 Hz
Inew = A
6.Hard
P = 45 kWQ1​S1​φ1​QC​

A single-phase load takes 45 kW at a power factor of 0.65 lagging from a 230 V, 60 Hz supply. A capacitor connected in parallel raises the power factor to 0.92. Find the capacitance C needed.

P = 45 kWpf1 = 0.65pf2 = 0.92V = 230 Vf = 60 Hz
C = µF

Answer key

  1. 1. cos φ = 0.65
  2. 2. cos φ = 0.7
  3. 3. R = 16 Ω
  4. 4. X = 5.268 Ω
  5. 5. Inew = 23.63 A
  6. 6. C = 1677 µF

Full step-by-step solutions: practise this topic on examproblems.com.