A load takes 44.5 kW of real power and 24.5 kvar of reactive power (lagging). Find the apparent power S.
AC power & power factor worksheet with answers
A single-phase load draws 6 A (rms) from a 120 V (rms) supply at a power factor of 0.9 lagging. Find the reactive power Q it takes.
A load with impedance Z = 24 + j7 Ω is connected to a 120 V (rms) single-phase supply. Find the real power P it absorbs.
An inductive load takes 12.5 A and 2700 W from a 240 V (rms) single-phase supply. Model it as a resistance R in series with a reactance X. Find R.
A single-phase load takes 15 kW at a power factor of 0.8 lagging from a 400 V, 60 Hz supply. A 22 µF capacitor is connected in parallel with the load. Find the new power factor cos φ seen by the supply.
A single-phase load takes 5 kW at a power factor of 0.7 lagging from a 240 V, 60 Hz supply. A capacitor connected in parallel raises the power factor to 0.92. Find the new line current Inew.
Answer key
- 1. S = 50.8 kVA
- 2. Q = 313.8 var
- 3. P = 553 W
- 4. R = 17.28 Ω
- 5. cos φ = 0.834
- 6. Inew = 22.64 A