A plant G(s) = 1/(s + 8) is placed in a unity negative feedback loop. A step of size 2 is applied at R. Find the steady-state output css.
Block diagrams worksheet with answers
A plant G(s) = 19/(s + 3) is placed in a unity negative feedback loop. Find the closed-loop DC gain T(0).
The plant G(s) = 10/(s + 6) has an inner (minor) negative feedback loop with gain H₁ = 2. A controller gain K = 14 and an outer unity negative feedback loop close the system. Find the closed-loop pole p.
A plant G(s) = 7/(s + 8) is controlled in a negative feedback loop whose sensor has the gain H = 0.25. A step of size 1 is applied at R. Find the steady-state output css.
A proportional controller K drives the plant G(s) = 3/(s + 9) in a unity negative feedback loop. A disturbance step of size 5 enters at the plant input while R = 0. Find the smallest gain K that keeps the steady-state output at or below 0.3333.
A proportional controller K drives the plant G(s) = 6/(s + 6) in a unity negative feedback loop. A disturbance step of size 2 enters at the plant input while R = 0. Find the smallest gain K that keeps the steady-state output at or below 0.2.
Answer key
- 1. css = 0.2222
- 2. T(0) = 0.8636
- 3. p = −166
- 4. css = 0.7179
- 5. K = 12
- 6. K = 9
Full step-by-step solutions: practise this topic on examproblems.com.