A plant G(s) = 4/(s + 8) is placed in a unity negative feedback loop. Find the time constant τ of the closed loop.
Block diagrams worksheet with answers
In the block diagram the forward path has the gains G₁ = 15 and G₂ = 8 in series, and the negative feedback path has the gain H = 0.5. Find the overall gain T = C/R.
The plant G(s) = 5/(s + 8) has an inner (minor) negative feedback loop with gain H₁ = 2. A controller gain K = 16 and an outer unity negative feedback loop close the system. Find the closed-loop DC gain T(0).
The plant G(s) = K/(s(s + 13)) is in a unity negative feedback loop. Find the gain K for which the closed loop is critically damped (two equal real poles).
A proportional controller K drives the plant G(s) = 8/(s + 7) in a unity negative feedback loop. A disturbance step of size 5 enters at the plant input while R = 0. Find the smallest gain K that keeps the steady-state output at or below 0.5714.
The plant G(s) = K/((s + 5)(s + 7)(s + 8)) is in a unity negative feedback loop. Use the Routh–Hurwitz criterion to find the largest gain Kmax for which the closed loop is stable.
Answer key
- 1. τ = 0.08333 s
- 2. T = 1.967
- 3. T(0) = 0.8163
- 4. K = 42.25
- 5. K = 7.875
- 6. Kmax = 2340
Full step-by-step solutions: practise this topic on examproblems.com.