The signal R splits into two parallel blocks G₂ = 7 and G₃ = 1. Their outputs meet at a summing junction with the signs shown (+ and +), and the sum passes through G₁ = 2. Find the overall gain T = C/R.
Block diagrams worksheet with answers
A plant G(s) = 3/(s + 2) is placed in a unity negative feedback loop. Find the time constant τ of the closed loop.
The plant G(s) = K/((s + 2)(s + 6)) is in a unity negative feedback loop. Find the gain K for which the closed loop is critically damped (two equal real poles).
The plant G(s) = 4/(s + 1) has an inner (minor) negative feedback loop with gain H₁ = 3. A controller gain K = 2 and an outer unity negative feedback loop close the system. Find the closed-loop DC gain T(0).
A proportional controller K drives the plant G(s) = 4/(s + 8) in a unity negative feedback loop. A disturbance step of size 5 enters at the plant input while R = 0. Find the smallest gain K that keeps the steady-state output at or below 0.125.
A proportional controller K = 5 drives the plant G(s) = 9/(s + 4) in a unity negative feedback loop. A disturbance D enters at the plant input (it is added to the controller output). With R = 0, a disturbance step of size 0.5 is applied. Find the steady-state output css.
Answer key
- 1. T = 16
- 2. τ = 0.2 s
- 3. K = 4
- 4. T(0) = 0.381
- 5. K = 38
- 6. css = 0.09184
Full step-by-step solutions: practise this topic on examproblems.com.