A column of length L made of steel is pinned at both ends. Using Euler’s formula, find its critical buckling load Pcr.
Column buckling worksheet with answers
A column of length L made of aluminium is pinned at both ends. Using Euler’s formula, find its critical buckling load Pcr.
A column of length L made of steel is fixed at the base and free at the top. Using Euler’s formula, find its critical buckling load Pcr.
A column of length L made of aluminium is fixed at the base and free at the top. Using Euler’s formula, find its critical buckling load Pcr.
A solid round column of length L made of steel is pinned at both ends. It must carry 75 kN with a factor of safety of 3 against buckling. Find the smallest diameter d.
A solid round column of length L made of aluminium is fixed at the base and pinned at the top. It must carry 65 kN with a factor of safety of 3 against buckling. Find the smallest diameter d.
Answer key
- 1. Pcr = 15.5 kN
- 2. Pcr = 4.395 kN
- 3. Pcr = 3.158 kN
- 4. Pcr = 7.369 kN
- 5. d = 61.72 mm
- 6. d = 81.94 mm
Full step-by-step solutions: practise this topic on examproblems.com.