A column of length L made of steel is pinned at both ends. Using Euler’s formula, find its critical buckling load Pcr.
Column buckling worksheet with answers
A column of length L made of aluminium is pinned at both ends. Using Euler’s formula, find its critical buckling load Pcr.
A column of length L made of steel is fixed at both ends. Using Euler’s formula, find its critical buckling load Pcr.
A column of length L made of steel is fixed at the base and free at the top. Using Euler’s formula, find its critical buckling load Pcr.
A solid round column of length L made of steel is fixed at both ends. It must carry 60 kN with a factor of safety of 2.5 against buckling. Find the smallest diameter d.
A solid round column of length L made of steel is fixed at both ends. It must carry 65 kN with a factor of safety of 2.5 against buckling. Find the smallest diameter d.
Answer key
- 1. Pcr = 2.193 kN
- 2. Pcr = 38.59 kN
- 3. Pcr = 635 kN
- 4. Pcr = 3.084 kN
- 5. d = 55.77 mm
- 6. d = 40.23 mm
Full step-by-step solutions: practise this topic on examproblems.com.