A column of length L made of aluminium is pinned at both ends. Using Euler’s formula, find its critical buckling load Pcr.
Column buckling worksheet with answers
A column of length L made of steel is pinned at both ends. Using Euler’s formula, find its critical buckling load Pcr.
A column of length L made of steel is fixed at the base and pinned at the top. Using Euler’s formula, find its critical buckling load Pcr.
A column of length L made of aluminium is fixed at both ends. Using Euler’s formula, find its critical buckling load Pcr.
A solid round column of length L made of steel is fixed at the base and pinned at the top. It must carry 140 kN with a factor of safety of 3 against buckling. Find the smallest diameter d.
A solid round column of length L made of steel is pinned at both ends. It must carry 80 kN with a factor of safety of 2 against buckling. Find the smallest diameter d.
Answer key
- 1. Pcr = 79.96 kN
- 2. Pcr = 66.62 kN
- 3. Pcr = 225 kN
- 4. Pcr = 188.7 kN
- 5. d = 60.36 mm
- 6. d = 62.09 mm
Full step-by-step solutions: practise this topic on examproblems.com.