An ideal boost converter runs from 15 V with a duty cycle D = 0.7 in continuous conduction. Find the output voltage Vo.
DC-DC converters worksheet with answers
An ideal boost converter runs from 24 V with a duty cycle D = 0.8 in continuous conduction. Find the output voltage Vo.
An ideal boost converter turns 24 V into 80 V for a 15 Ω load. Find the average inductor current IL.
An ideal buck converter turns 48 V into 33.6 V at a switching frequency of 50 kHz. Find the inductance L that keeps the peak-to-peak inductor ripple current at 0.8 A.
An ideal inverting buck-boost converter turns 36 V into −24 V for a 25 Ω load at 25 kHz. Find the smallest inductance Lcrit for continuous conduction.
An ideal buck-boost converter turns 48 V into −48 V for a 50 Ω load at 25 kHz. The output capacitor is 10 µF. Find the peak-to-peak output voltage ripple ΔVo in mV.
Answer key
- 1. Vo = 50 V
- 2. Vo = 120 V
- 3. IL = 17.78 A
- 4. L = 252 µH
- 5. Lcrit = 180 µH
- 6. ΔVo = 1920 mV
Full step-by-step solutions: practise this topic on examproblems.com.