An ideal inverting buck-boost converter runs from 36 V with a duty cycle D = 0.75 in continuous conduction. Find the magnitude of the output voltage |Vo|.
DC-DC converters worksheet with answers
An ideal buck converter runs from 12 V with a duty cycle D = 0.75 in continuous conduction. Find the output voltage Vo.
An ideal boost converter turns 36 V into 144 V for an 8 Ω load. Find the average inductor current IL.
An ideal inverting buck-boost converter turns 36 V into −54 V at 100 kHz with L = 68 µH. Find the peak-to-peak inductor ripple current ΔIL.
An ideal buck-boost converter turns 48 V into −144 V for a 2 Ω load at 250 kHz. The output capacitor is 22 µF. Find the peak-to-peak output voltage ripple ΔVo in mV.
An ideal boost converter turns 9 V into 36 V for a 50 Ω load at 25 kHz. The output capacitor is 470 µF. Find the peak-to-peak output voltage ripple ΔVo in mV.
Answer key
- 1. |Vo| = 108 V
- 2. Vo = 9 V
- 3. IL = 72 A
- 4. ΔIL = 3.176 A
- 5. ΔVo = 9818 mV
- 6. ΔVo = 45.96 mV
Full step-by-step solutions: practise this topic on examproblems.com.