An ideal inverting buck-boost converter must produce −60 V from 15 V in continuous conduction. Find the duty cycle D.
DC-DC converters worksheet with answers
An ideal boost converter runs from 24 V with a duty cycle D = 0.75 in continuous conduction. Find the output voltage Vo.
An ideal boost converter turns 24 V into 32 V at 100 kHz with L = 330 µH. Find the peak-to-peak inductor ripple current ΔIL.
An ideal buck converter turns 15 V into 10.5 V at a switching frequency of 100 kHz. Find the inductance L that keeps the peak-to-peak inductor ripple current at 0.6 A.
An ideal boost converter turns 24 V into 96 V for a 20 Ω load at 200 kHz. Find the smallest inductance Lcrit for continuous conduction.
An ideal inverting buck-boost converter turns 15 V into −35 V for a 12 Ω load at 500 kHz. Find the smallest inductance Lcrit for continuous conduction.
Answer key
- 1. D = 0.8
- 2. Vo = 96 V
- 3. ΔIL = 0.1818 A
- 4. L = 52.5 µH
- 5. Lcrit = 2.344 µH
- 6. Lcrit = 1.08 µH