Measure the PR interval on this lead II strip, in seconds.
ECG rhythm strip interpretation worksheet with answers
This lead II rhythm is regular. Count the small boxes between two consecutive R waves and use the 1500 method to find the heart rate in beats per minute, rounded to a whole number.
Interpret this lead II rhythm strip. Which rhythm is it? Click your answer.
- 1junctional rhythm
- 2normal sinus rhythm
- 3sinus bradycardia
- 4sinus arrhythmia
Measure the QT interval and the R–R interval on this regular lead II strip, then calculate the rate-corrected QTc with Bazett’s formula QTc = QT/√RR (both in seconds). Give the answer in seconds to three decimals.
Interpret this lead II strip with the five steps in order: rate, rhythm, P waves, PR interval, QRS duration. At which step do you find the first abnormal finding? Click it.
- 1rate
- 2rhythm
- 3P waves
- 4PR interval
- 5QRS duration
This lead II strip shows second-degree AV block type I (Wenckebach). Measure the PR interval of the last conducted beat before a non-conducted P wave (the longest PR), in seconds.
Answer key
- 1. PR = 0.2 s
- 2. heart rate = 58 bpm
- 3. normal sinus rhythm
- 4. QTc = 0.469 s
- 5. rhythm
- 6. longest PR = 0.32 s
Full step-by-step solutions: practise this topic on examproblems.com.