In a counter-flow heat exchanger the hot fluid cools from 175 to 100 °C while the cold fluid heats from 10 to 130 °C. Find the log-mean temperature difference ΔTlm.
Heat exchangers (LMTD) worksheet with answers
A counter-flow heat exchanger has a heat transfer area of 2 m² and an overall heat transfer coefficient of 800 W/(m²·K). The hot fluid cools from 110 to 80 °C and the cold fluid heats from 30 to 50 °C. Find the heat transfer rate Q̇.
In a condenser, steam condenses at a constant 120 °C on the outside of the tubes. Cooling water (5 kg/s, cp = 4.18 kJ/(kg·K)) flows through the tubes and heats from 10 to 80 °C. The overall heat transfer coefficient is 1500 W/(m²·K). Find the heat transfer area A needed.
A shell-and-tube heat exchanger (one shell pass, two tube passes) must transfer 660 kW. The hot fluid cools from 170 to 80 °C and the cold fluid heats from 20 to 120 °C. The LMTD correction factor for this arrangement is F = 0.92, and U = 800 W/(m²·K). Find the heat transfer area A needed.
In a parallel-flow double-pipe heat exchanger, hot oil (0.3 kg/s, cp = 2.1 kJ/(kg·K)) flows in the inner tube and cools from 145 to 70 °C. Water (1 kg/s, cp = 4.18 kJ/(kg·K)) in the annulus enters at 25 °C. The inner tube has a diameter of 25 mm, and U = 400 W/(m²·K) is based on this diameter. Find the tube length L needed.
Hot oil (1 kg/s, cp = 2.5 kJ/(kg·K)) cools from 165 to 115 °C in a counter-flow exchanger. It heats 0.5 kg/s of water (cp = 4.18 kJ/(kg·K)) that enters at 15 °C. With U = 800 W/(m²·K), find the heat transfer area A needed.
Answer key
- 1. ΔTlm = 64.92 K
- 2. Q̇ = 87.76 kW
- 3. A = 14.09 m²
- 4. A = 16.35 m²
- 5. L = 22.13 m
- 6. A = 1.645 m²
Full step-by-step solutions: practise this topic on examproblems.com.