Hot oil (0.5 kg/s, cp = 2.3 kJ/(kg·K)) cools from 150 to 80 °C in a counter-flow exchanger. It heats 0.5 kg/s of water (cp = 4.18 kJ/(kg·K)) that enters at 20 °C. No heat is lost to the surroundings. Find the water outlet temperature Tc,out.
Heat exchangers (LMTD) worksheet with answers
In a parallel-flow heat exchanger the hot fluid cools from 150 to 130 °C while the cold fluid heats from 25 to 125 °C. Find the log-mean temperature difference ΔTlm.
In a condenser, steam condenses at a constant 100 °C on the outside of the tubes. Cooling water (1 kg/s, cp = 4.18 kJ/(kg·K)) flows through the tubes and heats from 25 to 85 °C. The overall heat transfer coefficient is 2000 W/(m²·K). Find the heat transfer area A needed.
A counter-flow heat exchanger transfers 260 kW. The hot fluid cools from 90 to 45 °C and the cold fluid heats from 10 to 65 °C. The overall heat transfer coefficient is 200 W/(m²·K). Find the heat transfer area A needed.
Hot oil (2 kg/s, cp = 2.3 kJ/(kg·K)) cools from 130 to 70 °C in a counter-flow exchanger. It heats 1 kg/s of water (cp = 4.18 kJ/(kg·K)) that enters at 20 °C. With U = 800 W/(m²·K), find the heat transfer area A needed.
Hot oil (1.5 kg/s, cp = 2.1 kJ/(kg·K)) cools from 90 to 45 °C in a counter-flow exchanger. It heats 1.5 kg/s of water (cp = 4.18 kJ/(kg·K)) that enters at 15 °C. With U = 1500 W/(m²·K), find the heat transfer area A needed.
Answer key
- 1. Tc,out = 58.52 °C
- 2. ΔTlm = 37.28 K
- 3. A = 3.364 m²
- 4. A = 43.74 m²
- 5. A = 7.353 m²
- 6. A = 2.353 m²