A counter-flow heat exchanger has a heat transfer area of 2.5 m² and an overall heat transfer coefficient of 500 W/(m²·K). The hot fluid cools from 175 to 95 °C and the cold fluid heats from 30 to 75 °C. Find the heat transfer rate Q̇.
Heat exchangers (LMTD) worksheet with answers
In a counter-flow heat exchanger the hot fluid cools from 160 to 25 °C while the cold fluid heats from 10 to 75 °C. Find the log-mean temperature difference ΔTlm.
A parallel-flow heat exchanger transfers 60 kW. The hot fluid cools from 140 to 95 °C and the cold fluid heats from 30 to 55 °C. The overall heat transfer coefficient is 200 W/(m²·K). Find the heat transfer area A needed.
A counter-flow heat exchanger transfers 210 kW. Its heat transfer area is 25 m². The hot fluid cools from 95 to 35 °C and the cold fluid heats from 10 to 25 °C. Find the overall heat transfer coefficient U.
Hot oil (2 kg/s, cp = 2.5 kJ/(kg·K)) cools from 180 to 80 °C in a counter-flow exchanger. It heats 3 kg/s of water (cp = 4.18 kJ/(kg·K)) that enters at 30 °C. With U = 300 W/(m²·K), find the heat transfer area A needed.
In a counter-flow double-pipe heat exchanger, hot oil (1 kg/s, cp = 2.5 kJ/(kg·K)) flows in the inner tube and cools from 110 to 80 °C. Water (1 kg/s, cp = 4.18 kJ/(kg·K)) in the annulus enters at 25 °C. The inner tube has a diameter of 20 mm, and U = 200 W/(m²·K) is based on this diameter. Find the tube length L needed.
Answer key
- 1. Q̇ = 101.6 kW
- 2. ΔTlm = 40.36 K
- 3. A = 4.335 m²
- 4. U = 192.2 W/(m²·K)
- 5. A = 21.89 m²
- 6. L = 98.12 m
Full step-by-step solutions: practise this topic on examproblems.com.