Hot oil (2 kg/s, cp = 2.5 kJ/(kg·K)) cools from 160 to 110 °C in a counter-flow exchanger. It heats 3 kg/s of water (cp = 4.18 kJ/(kg·K)) that enters at 10 °C. No heat is lost to the surroundings. Find the water outlet temperature Tc,out.
Heat exchangers (LMTD) worksheet with answers
Hot oil (2 kg/s, cp = 2.5 kJ/(kg·K)) cools from 165 to 105 °C in a counter-flow exchanger. It heats 1.5 kg/s of water (cp = 4.18 kJ/(kg·K)) that enters at 30 °C. No heat is lost to the surroundings. Find the water outlet temperature Tc,out.
A counter-flow heat exchanger transfers 450 kW. The hot fluid cools from 170 to 140 °C and the cold fluid heats from 30 to 55 °C. The overall heat transfer coefficient is 1000 W/(m²·K). Find the heat transfer area A needed.
A shell-and-tube heat exchanger (one shell pass, two tube passes) must transfer 100 kW. The hot fluid cools from 130 to 105 °C and the cold fluid heats from 30 to 60 °C. The LMTD correction factor for this arrangement is F = 0.88, and U = 200 W/(m²·K). Find the heat transfer area A needed.
In a parallel-flow double-pipe heat exchanger, hot oil (0.3 kg/s, cp = 2.1 kJ/(kg·K)) flows in the inner tube and cools from 145 to 110 °C. Water (0.3 kg/s, cp = 4.18 kJ/(kg·K)) in the annulus enters at 20 °C. The inner tube has a diameter of 50 mm, and U = 500 W/(m²·K) is based on this diameter. Find the tube length L needed.
Hot oil (2 kg/s, cp = 2.1 kJ/(kg·K)) cools from 115 to 35 °C in a counter-flow exchanger. It heats 2 kg/s of water (cp = 4.18 kJ/(kg·K)) that enters at 15 °C. With U = 300 W/(m²·K), find the heat transfer area A needed.
Answer key
- 1. Tc,out = 29.94 °C
- 2. Tc,out = 77.85 °C
- 3. A = 4.001 m²
- 4. A = 7.84 m²
- 5. L = 2.915 m
- 6. A = 30.82 m²
Full step-by-step solutions: practise this topic on examproblems.com.