Reactor sizing (CSTR & PFR) worksheet with answers

Free printable Reactor sizing (CSTR & PFR) worksheet: 6 problems from easy to exam level, with an answer key. Print it or save it as a PDF.

For teachers: free to print, copy and use in class. Every new worksheet has new values and its own answer key. A link to ExamProblems on your course page is appreciated.

Name: ____________________   Date: ____________

1.Easy
V = 200 L, k = 0.1 min⁻¹Q = 25 L/minCA0​ = 2.5 mol/LCA​ = ?

A liquid-phase first-order reaction A → B (k = 0.1 min⁻¹) runs in a 200 L continuous stirred-tank reactor (CSTR). The feed enters at 25 L/min with CA0 = 2.5 mol/L. The density is constant and the reactor is at steady state. Find the outlet concentration CA.

V = 200 LQ = 25 L/mink = 0.1 min⁻¹CA0 = 2.5 mol/L
CA = mol/L
2.Easy
τ = ?k = 0.12 min⁻¹X = 80%

A first-order liquid-phase reaction with k = 0.12 min⁻¹ runs in a CSTR at steady state. What space time τ is needed to reach 80% conversion?

k = 0.12 min⁻¹X = 80%
τ = min
3.Medium
Q = 10 L/minX = 60%V = ?, k = 0.1 min⁻¹

A first-order liquid-phase reaction A → B with k = 0.1 min⁻¹ is carried out in a plug-flow reactor (PFR) fed at 10 L/min. The density is constant and the reactor is at steady state. Find the reactor volume V in litres for 60% conversion of A.

Q = 10 L/mink = 0.1 min⁻¹X = 60%
V = L
4.Medium
Q = 25 L/minX = 50%V = ?, k = 0.12 min⁻¹

A first-order liquid-phase reaction A → B with k = 0.12 min⁻¹ is carried out in a plug-flow reactor (PFR) fed at 25 L/min. The density is constant and the reactor is at steady state. Find the reactor volume V in litres for 50% conversion of A.

Q = 25 L/mink = 0.12 min⁻¹X = 50%
V = L
5.Hard
V = 800 LQ = 5 L/minX = ?

A first-order liquid-phase reaction (k = 0.4 min⁻¹) runs in an 800 L CSTR fed at 5 L/min. The density is constant and the reactor is at steady state. Find the conversion X in percent.

V = 800 LQ = 5 L/mink = 0.4 min⁻¹
X = %
6.Hard
Q = 40 L/minX = ?V = 200 L

A first-order liquid-phase reaction (k = 0.25 min⁻¹) runs in a 200 L plug-flow reactor (PFR) fed at 40 L/min. The density is constant and the reactor is at steady state. Find the conversion X in percent.

V = 200 LQ = 40 L/mink = 0.25 min⁻¹
X = %

Answer key

  1. 1. CA = 1.389 mol/L
  2. 2. τ = 33.33 min
  3. 3. V = 91.63 L
  4. 4. V = 144.4 L
  5. 5. X = 98.46 %
  6. 6. X = 71.35 %