Reactor sizing (CSTR & PFR) worksheet with answers

Free printable Reactor sizing (CSTR & PFR) worksheet: 6 problems from easy to exam level, with an answer key. Print it or save it as a PDF.

For teachers: free to print, copy and use in class. Every new worksheet has new values and its own answer key. A link to ExamProblems on your course page is appreciated.

Name: ____________________   Date: ____________

1.Easy
V = ?, k = 0.2 min⁻¹Q = 100 L/minX = 75%

A first-order liquid-phase reaction A → B with k = 0.2 min⁻¹ is carried out in a continuous stirred-tank reactor (CSTR) fed at 100 L/min. The density is constant and the reactor is at steady state. Find the reactor volume V in litres for 75% conversion of A.

Q = 100 L/mink = 0.2 min⁻¹X = 75%
V = L
2.Easy
τ = ?k = 0.3 min⁻¹X = 75%

A first-order liquid-phase reaction with k = 0.3 min⁻¹ runs in a CSTR at steady state. What space time τ is needed to reach 75% conversion?

k = 0.3 min⁻¹X = 75%
τ = min
3.Medium
QX = 90%same Q, k and X as the CSTR

A first-order liquid-phase reaction must reach 90% conversion. How many times larger must a CSTR be than a PFR for the same feed rate, rate constant and conversion? Find the ratio VCSTR/VPFR.

X = 90%first order, same k and Q
VCSTR/VPFR =
4.Medium
Q = 100 L/minX = 50%V = ?, k = 0.15 min⁻¹

A first-order liquid-phase reaction A → B with k = 0.15 min⁻¹ is carried out in a plug-flow reactor (PFR) fed at 100 L/min. The density is constant and the reactor is at steady state. Find the reactor volume V in litres for 50% conversion of A.

Q = 100 L/mink = 0.15 min⁻¹X = 50%
V = L
5.Hard
V = 2000 LQ = 25 L/minX = ?

A first-order liquid-phase reaction (k = 0.4 min⁻¹) runs in a 2000 L CSTR fed at 25 L/min. The density is constant and the reactor is at steady state. Find the conversion X in percent.

V = 2000 LQ = 25 L/mink = 0.4 min⁻¹
X = %
6.Hard
V = 100 LV = 100 LQ = 25 L/minX = ?

A first-order liquid-phase reaction (k = 0.15 min⁻¹) runs in two equal CSTRs in series, each of 100 L. The feed rate is 25 L/min, the density is constant and the reactors are at steady state. Find the overall conversion X in percent.

V = 100 L (×2)Q = 25 L/mink = 0.15 min⁻¹
X = %

Answer key

  1. 1. V = 1500 L
  2. 2. τ = 10 min
  3. 3. VCSTR/VPFR = 3.909
  4. 4. V = 462.1 L
  5. 5. X = 96.97 %
  6. 6. X = 60.94 %