The controller C(s) = 4(s + 5)/s drives the plant G(s) = 5/(s(s + 4)) in a unity-feedback loop. What is the system type N of the loop?
Steady-state error & PID control worksheet with answers
A unity-feedback loop has the open-loop transfer function G(s) = 5(s + 3)/(s²(s + 10)). Find the acceleration error constant Ka.
The parabolic input r(t) = 4·t²/2 is applied to a unity-feedback loop with G(s) = 5(s + 2)/(s²(s + 4)). Find the steady-state error ess.
A ramp r(t) = 0.5t is applied to a unity-feedback loop with G(s) = 10/(s(s + 2)(s + 4)). Find the steady-state error ess.
A PI controller C(s) = 1 + 4/s drives the plant G(s) = 2/((s + 1)(s + 10)) in a unity-feedback loop. Find the steady-state error ess for the ramp input r(t) = 5t.
A proportional controller K drives the plant G(s) = 10/(s(s + 6)) in a unity-feedback loop. Find the gain K that gives the closed loop a damping ratio ζ = 0.4.
Answer key
- 1. N = 2
- 2. Ka = 1.5
- 3. ess = 1.6
- 4. ess = 0.4
- 5. ess = 6.25
- 6. K = 5.625